MATERIAL : M. S. STEEL
FINISH : COPPER
In a Earthing/Grounding system, the Copper Bonded Rod provides the physical connection to the earth
and is the instrument used to dissipate current into it. There are two main types of electrodes.
“Natural” electrodes are intrinsic to the facility and include metal underground water pipe, the metal
include wire meshes, metallic plates, buried copper conductor and rods or pipe driven into the Copper
Bonded Rod.
· Perfectly bonded Copper Bonded Grounding Rod will lost longer, drive easier and will not crack. 9.5 x 1200 9.5 Unthreaded CBR-912
· In Copper Bonded Rod, Copper purity is 99.95%. 9.5 x 1800 9.5 Unthreaded CBR-918
· The Copper Bonded Rods is fully covered with copper cladding without any cracks, holes, cavities.
14 x 1200 12 14 CBR-1412
Threads are rolled by roll threading process, which ensures that when copper covers is
maintained, at the root of the thread, Roll thread gives greater strength than cut thread. 14 x 1500 12 14 CBR-1415
· Magnetic conducting rate is low. Thus reducing the lightning induction. 14 x 1800 12 14 CBR-1418
· Good tensile strength in Copper Bonded Rod, over 600N/mm2.
14 x 2000 12 14 CBR-1420
· Resist corrosion better than galvanised rods allowing for a 30-year service life in most soils
· Corrosion resistance while providing the lowest resistance to ground. 14 x 2400 12 14 CBR-1424
· Preventing exposure of the steel core to soil and moisture. The Copper Bonded Rod is suitably 5/8"x 4" or 16mm x 1200 14.2 5/8" CBR-112
treated to prevent oxidation of copper bonding. The Copper Bonded Rod is capable of being bent 90
5/8" x 5" or 16mm x 1500 14.2 5/8" CBR-115
between the steel and the copper cladding. 5/8" x 6" or 16mm x 1800 14.2 5/8" CBR-118
· Thread rolling process raises the surface of the rod, so teat Thread dia. (T) is greater 5/8" x 8" or 16mm x 2400 14.2 5/8" CBR-124
than Shank dia. (S). Copper layer is over 0.254mm (copper layer thickness can be on request,
5/8" x 10" or 16mm x 3000 14.2 5/8" CBR-130
such as 0.10mm, 0.25mm, 0.100mm, 0.150mm, 0.200mm, 0.254mm etc. upto 0.850mm).
Please note that 0.254mm is also known as 254 micron or 0.10mm as 100 micron but if 5/8" x 4" or 16mm x 1200 16 5/8" CBR-312
our customer request for Standard Micron i.e 15-25 micron, than we also manufacture in standard 5/8" x 5" or 16mm x 1500 16 5/8" CBR-315
micron)
5/8" x 6" or 16mm x 1800 16 5/8" CBR-318
greater resistance to corrosion. They are ideally used in applications where soil conditions are very
aggressive. Solid copper Earth Rod is used when better conductivity and corrosion resistance is which is also known as Copper Earthing Plate / Copper Bonded Earthing Plate.
preferred. Pure Copper Earth Rod are of two types. Externally threaded and Internally threaded. These copper Earth plates are quite durable due to the fact that they are resistant from oxidations
Pure Copper Earth Rods is used where the factor of corrosion is very high and exceptionally long life and corrosion.
is required. It Meets ASTM B 133 & ASTM B 187. Due to softness of pure copper, care must be taken
when driving electrode.
made of a conductive plastic or metal mesh covered substrate which is electrically attached to earth.
ASTM B 133 & ASTM B 187. Due to softness of pure copper, care must be taken when driving electrode. This helps discharge any static charge which a worker has built up, as well as any static charge on
damaged from the hazards of fault current. Pure Copper Earth Rod is manufactured As Per tools or exposed components lay on the mat.
Customers Requirement to the which is internationally accepted.
Grounding mats are also found on fuel trucks and tankers, which are otherwise insulated from ground
as they make physical contact only with their tires and the air obviously static discharge is undesirable
during fuel-transfer operations. Similarly, in aircraft refuelling, a grounding mat cable connects the
transferred.
In an electrical substation and ground mat is a mesh of conductive material installed at places where
a person would stand to operate a switch or other apparatus; it is bonded to the local supporting
metal structure and to the handle of the switchgear, so that the person operator will not be exposed
157 158
CUB ANO AIR TERMINAL LIGHTNING ROD CUB ANO MULTIPLE POINT
R od Dia. mm Total L ength mm Thr ead Dia. Pr od. Code CUB ANO COPPER BONDED EARTH RODS
R od Unit
Nominal L ength Thr ead Par t
Diameter Weight
Size mm Size Number
mm kg
159 160
CUB ANO SOLID COPPER EARTHING RODS CUB ANO FLEXIBLE COPPER BRAID BONDS
Solid Copper Earthing Rods are made for solid copper bar and are internally threaded for joining. These Flexible Copper Braid Bonds are used for bonding metal gates etc.
These Solid Copper Earthing Rods are used where high corrosion resistance is there for long life
required.
161 162
CUB ANO CUBANO BIMETALLIC CONNECTING TERMINALS
Application
Bimetallic lugs for aluminium conductors.MV terminations.
LV connection on busbar inside electrical panel.lRange from 16 to 1000 mm2. One technology for all the sizes
of cables.lFriction welding technology. Age resistant current passage from
the aluminum shift to the solid copper plate.lCrimped deep step indentation. High quality connections
independent installer’s skills.lSingle connector model for a given conductor cross-sectional
area (independent of the core compression ratio).lAluminum barrel and solid copper palm. Best technical solution
to connect aluminium conductor to a copper bar.
SIZE
T
0.25-6 SQMM w D
6.0-16 SQMM
0.25-6 SQMM
6.0-16 SQMM d
CABLE
SR.NO. O D d L L-1 W T CAT NO.
SIZE
1 16 13 16 5.5 90 42 24 4 CBL-16
2 25 13 16 6.5 90 42 24 4 CBL-25
3 35 13 16 8 90 42 24 4 CBL-35
4 50 13 20 9 92 43 24 5 CBL-50
5 70 13 20 11 92 43 24 5 CBL-70
6 95 13 20 12.5 92 43 24 5 CBL-95
163 164
CUB ANO COPPER ALUMINIUM CONNECTING TUBES CUB ANO WATER PROOF CONNECTOR
SR.NO. D1 d1 D d L-1 L-2 L CAT NO. Rated operational voltage AC250V Rated operational voltage 400V
19 10 5.5 12 7.0 32 30 80 CBC-10 Insulation resistance 500M~DC500V Pollution degree IP68 protection
31 38 29.0 54 34.0 80 70 170 CBC-38 Rated operational voltage AC250V Model L20-2care L20-3core L20-4core
165 166
CUBANO COPPER C-TYPE BRANCH CLAMPS,MULTI-PURPOSE CLAMPS
CUB ANO COPPER TWO HOLE CABLE LUGS For non-tension copper cables, e.g. according to DIN 48201-1 Ideal for clamping different
TUBULAR TERMINAL ENDS conductor cross-sections e.g. to DIN EN 60228 Cl. 1 and 2 No need to cut the main conductor
CABLE
SR.NO. E A C B D G L CAT NO.
SIZE