You are on page 1of 77

7 Error Code > Error Code > Error Code Details > E000 to E069

7-3

Error Code E Detail


Location Item Description
Code Code
E001 -0002 -05 Title Fixing Assembly high temperature error (software detection)
Error Code Details Remedy 1. Check if the cable of the Thermistor is caught. -> Replace
the Thermistors. -> Replace the Fixing Upper Unit.
■ E000 to E069 2. IH control error. -> Replace the Fixing Power Supply PCB
(PCB10), the DC Controller PCB (PCB1), or the Main
E Detail Driver PCB (PCB2).
Location Item Description
Code Code Description • The Fixing Main Thermistor (THM1) detects 230 degC or
E000 -0001 -05 Title Fixing Assembly low temperature error higher.
Remedy 1. Check the connection of the Fixing Assembly. (Connection • The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
error of the Drawer, connector disconnection, open circuit) 2 (THM3) detects 230 degC or higher for 2 consecutive
-> Replace the Heater Assembly. seconds.
2. Check the connection between the Main Driver PCB (PCB2) E001 -0003 -05 Title Fixing Assembly high temperature error (hardware detection)
and the Fixing Power Supply PCB (PCB10) (connector Remedy 1. Check if the cable of the Thermistor is caught. -> Replace
disconnection, open circuit, the caught cable). the Thermistors. -> Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10). 2. Replace the Main Driver PCB (PCB2).
4. Replace the Main Driver PCB (PCB2). 3. Replace the DC Controller PCB (PCB1).
5. Replace the DC Controller PCB (PCB1). Description • The Fixing Main Thermistor (THM1) detects hardware
Description Temperature of the Fixing Main Thermistor (THM1) does overheating.
not reach 70 degC although 20 seconds have passed after • The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
starting the Fixing Roller temperature control. 2 (THM3) detects hardware overheating.
E000 -0002 -05 Title Fixing Assembly low temperature error E001 -0004 -05 Title Fixing Assembly high temperature error (hardware detection)
Remedy 1. Check the connection of the Fixing Assembly. (Connection Remedy 1. Check if the cable of the Thermistor is caught or is open
error of the Drawer, connector disconnection, open circuit) circuit. -> Replace the Thermistors. -> Replace the Fixing
-> Replace the Heater Assembly. Upper Unit.
2. Check the connection between the Main Driver PCB (PCB2) 2. Replace the Main Driver PCB (PCB2).
and the Fixing Power Supply PCB (PCB10) (connector 3. Replace the DC Controller PCB (PCB1).
disconnection, open circuit, the caught cable). 4. Check if the Fixing Shutter operates. -> Replace the Fixing
3. Replace the Fixing Power Supply PCB (PCB10). Assembly.
4. Replace the Main Driver PCB (PCB2). Description Abnormal temperature difference among the Thermistors was
5. Replace the DC Controller PCB (PCB1). detected.
Description Temperature of the Fixing Main Thermistor (THM1) does E001 -0010 -05 Title Fixing Assembly high temperature error
not reach 10 degC although 20 seconds have passed after Remedy Clear the error.
starting the Fixing Roller temperature control.
Description Turning OFF and then ON the power without clearing the
E000 -0010 -05 Title Fixing Assembly low temperature error
error.
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the
error.