Inspection of Pump 1
In this inspection, software can check if pump displacement is correctly following flow commands.
• Pump 1 pressure.
• Pump 2 pressure.
Adjustment signal:
1
• Pump 1 flow (%) (default : minimum flow) 10% by changing.
Illustration 1 g06043288
Illustration displaying the states of specific valves on the excavator for the Inspection of Pump 1.
Inspection of Pump 2
In this inspection, software can check if pump displacement is correctly following flow commands.
2
The operator monitor should be displaying:
• Pump 1 pressure.
• Pump 2 pressure.
Adjustment signal:
Illustration 2 g06043276
Illustration displaying the states of specific valves on the excavator for the Inspection of Pump 2.
3
Illustration 3 g06041761
The "Device Test" menu is located under "Service" that is selected from the "Main Menu."
Illustration 4 g06041768
When the "Device Test" menu is selected, the following options are presented:
• Attachment Valves
4
• Health Check
Illustration 5 g06041776
When the "Health Check" menu is selected, the following options are presented:
• Boom Circuit #1
• Boom Circuit #2
• Stick Circuit #1
• Stick Circuit #2
• Swash Plate #1
• Swash Plate #2
• Manual Valve
4. Hydraulic oil temperature must be between 40° C (104° F) and 60° C (140° F).
5. Move the machine to level ground. Place the stick and bucket cylinder in the minimum retract position
and lower the boom until the linkage is resting on the ground. Press "OK" to continue.
5
Illustration 6 g06043295
Set the solenoid (electrical) current for "Pump 1" at 50% (minimum speed). Use the "Slide Bar" to increase or decrease
pump flow if needed. Press "OK" to continue.
Illustration 7 g06043300
6
Press the DOWN arrow on the touch pad during Step 7.
Note: Move any implement control input to the extreme position to begin the calibration. Releasing the
control before the calibration is complete will cause the calibration to abort.
Illustration 8 g06043302
View the "Pump #1 Solenoid Current Percentage", if the pump is operating correctly, the reading should closely match the
setting during Step 5.
6. The "Health Check" test is active. Observe the pump pressure on the monitor or in Cat ET. To reset
pump flow or exit the test, release the lever.
Note: If there is a significant difference between actual pump displacement position (%) and solenoid
current (%), the pump has an issue.
Table 1
ACS Valve Inspection Table
Health Check Test Mode
Potential
Source of Root Boom Stick Boom Stick Swash Swash
Manual
Cause Circuit #1 Circuit #1 Circuit #2 Circuit #2 Plate #1 Plate #2
Valve (7)
(1) (2) (3) (4) (5) (6)
Bypass 1 X X X
Bypass 2 X X X
Main Relief X X X X X
Warm Up 1 X X X X
Warm Up 2 X X X X
Straight Travel X
7
Combiner X
Pump 1 X X
Pump 2 X X
The table above shows the possible root causes. By conducting a combination of "Health Check" tests the
technician can better determine which component has an issue.
For Example: If "Test Mode 1" passes with no errors and the results from "Test Mode 3" show an error, the
"Warm Up 2" is the root cause of the issue.
For Test Modes 5 & 6: Actual pump displacement position is shown on the monitor when the test is started.
Check to see if pump displacement position (%) is the same as pump solenoid current (%).