You are on page 1of 1

GENERAL NOTES

1. This drawing is for design intent purposes only and is not to be scaled.
NOTES: 2. All dimensions shown are in millimeters and are taken from the applied
finishes.
1. DRAWING TO BE READ IN CONJUNCTION WITH : 3. All dimensions are to be verified on site by the contractor prior to
· A32 SERIES DRAWINGS manufacture and installation.
· ID DOOR SCHEDULE 4. Any omissions or discrepancies found shall be reported to the ID
· ID FINISHES SCHEDULE consultant / Engineer immediately for clarification.
5. This drawing is to be read in conjunction with the relevant section of the
2. FOR ALL WINDOWS REFER TO ARCHITECTS WINDOW specifications, schedules and drawings referenced.
SCHEDULE. 6. All necessary structural supports to all items including ceiling hung, wall
3. FOR INTERCONNECTING DOORS VARIANTS REFER TO hung, built-in units or cantilevered items shall be of adequate strength to
GENERAL ARRANGEMENT KEYPLAN DRAWINGS ensure stability and shall be considered by the contractor.
7. The contractor shall submit full shop / setting out drawings for approval
(based on site dimensions) prior to commencement of any site works, or
placing any orders and on manufacture of any fittings, fixtures and
components shown.
4 5 6 7 8 9 10 11 12 8. All work must conform to municipality regulations, national and
international building code and all regulations by governing authorities.
9. The contractor must ensure all coordination between his work, his
subcontractors and the ID consultant's design.
10. All interior finishes must have a flame-spread rating and smoke density
rating to meet or exceed local code requirements.

REVISIONS
C NO DATE DESCRIPTION REV BY
C0 26.SEP.2019 ISSUED FOR CONSTRUCTION ES

LIFT-1 LIFT-2 LIFT-3 LIFT-4

PASSAGE TO BOH
545 1000 1200 1000 1200 1000 1550 1000 615
E 9110

115
40335 40 1000 40 EQ. 40 1000 40 EQ. 40 EQ. 40 EQ. 40 EQ. 40 EQ. 40 EQ. 990 1185 EQ. 40 EQ. 40 EQ. 40 EQ. 40 EQ. 40 EQ. 40
10250 8170

1090
ID-40 PASSAGE
ID-41A ID-41 EL-01
EL-03 EL-02 TO BOH

990
915 1078 510
DESIGN ARCHITECTS
PU EL-201 JU EL-202
1 PU EL-201 PU EL-201
(TD)A78-730
1500

ARCHITECT OF RECORD
EL

5795
Ø200 Ø200 Ø200 REGISTRATION PODS
0 0 0

F MAZAYA

1
(TD)A78-731
JU EL-201 JU EL-201 JU EL-201
522

1155 G A J Middle East

750
1430 6670 1155 7120 1155 6670 235
Architectural Consultants

SCANNER

EL
4300

4300
EL VESTIBULE EL
LOUNGE AREA LOUNGE AREA

KEY PLAN
JU EL-205 JU EL-203 JU EL-204 JU EL-204
CLIENT

MR. MARWAN YASEEN AL ZAEEM


250

250
G

1 1
900

900 4
(TD)A78-734 (TD)A78-733
1 (TD)A78-730A
ISSUED FOR
(TD)A78-733 TENDER
500

JU EL-207 PROJECT

3423 Hilton Double Tree


Sharjah, UAE
LEGEND

BLOCK WORK
(REFER TO ACOUSTIC CONSULTANT DRAWINGS) DRAWING TITLE

DRY WALL
(REFER TO ACOUSTIC CONSULTANT DRAWINGS)
Ground Floor Level
Entrance Lobby
NOTE: DRY WALL COMPOSITION SHOULD BE CONSIDERED BASED ON
1 PLAN LOCATION. General Arrangement Plan
A. FOR WET AREAS, WATER AND MOISTURE RESISTANT (SHEET
SCALE-1:50 ROCK TYPE) SHOULD BE CONSIDERED. CONTRACTOR TO
- FINALIZE TYPE AND WATER PROOFING MEMBRANE
ACCORDINGLY. Drawn HV Checked HS Approved EC
B. FOR DRY AREAS, CONTRACTOR TO USE NORMAL DRY WALL
GYPSUM BOARD. CONTRACTOR TO ADVISE ON TYPE AND Date 07.05.2017 Scale 1:50@A1
PROCEED ACCORDINGLY.
Project No. Zone Drawing No. Rev.
INTERIOR DOOR TAG LEGEND 3423 (EL) L22-300 C0
ID-02 DOOR TYPE Authority Dwg. No. Consecutive No.
MU1B-01
DOOR NUMBER
This drawing, the designs and details shown are the copyright of
ZONE CODE G A J MIDDLE EAST Architectural Consultants and shall not
be copied or reproduced in any form without their written consent.
NOT IN ID SCOPE REFER TO ARCH. DRAWING
T:+971 4 323 7555 E: mail@gaj-uae.ae
F: +971 4 323 7717 W: www.godwinaustenjohnson.com
PO Box 7185 Dubai United Arab Emirates

A1 Original Sheet
Size
FILE PATH : \\Plutus\data\- PROJECTS CURRENT\3423 - Hilton Double Tree SHJ\LIVE\ACAD\Sheets\1.0 Public Areas\A. Entrance Lobby\3423-(EL)L22-300.dwg 26 Sep, 2019 - 4:41pm