NOTES

SHOPS
GENERAL
All dimensions are in mm unless otherwise specified.
Drawing are not to scalled. Only figured dimensions to be
used
The contractor must check and verify all demensions before
ACESS ROAD commencement of any work.

375 75 75 75 75 75 75 75 75 75 375 CONSTRUCTION


4,325 4,325 4,325 4,325 4,325 4,325 4,325 4,325
All slab at ground level to be poured over 1000 guage polythene
sheet on 50mm thick murram blinding on hardcore.

REVENUE
All soil under slab around and under foundation to be poisoned

OFFICE
for termite control.

11,357
3,300 18,071
ELEVATION 02
All soil on cut embarkment to be stablized.The slope not to
exceed the natural angle of repose

STRUCTURAL
10,000 All black cotton soil to be removed from all buildings and paved

B A For all R.C work,refer to stuctural Engineer's details.

PROPOSED SHED 1 28 gauge IT4 roofing sheets on Steel trusses to S.E


CIVIL
detail. 18 gauge ms sheet welded to steel structure, painted to
36X9.8M Pitch = 22.50 client colour specs.
Depth of foundation to be detemined on site to S.E's aproval
Artwork/ logo to be embeded to approval All walls less than 150mm thick to be reinforced with hoop iron at
every alternate course.

400
STALLS

2,400
200x200 box gutter made from gauge 22 resincot
prepainted galvanised flat iron sheets to eng's details
All adjacent R.C. work and masonry walls to be tied with hoop iron
at every alternate course.
surfaces
Rainwater goods in UPVC to approval.
42,189 600 600 Rainwater goods in UPVC to approval.
MECHANICAL
PROPOSED SHED 2 100 x 100 x 4mm SHS; 3300mm high Columns; one
All plumbing and drainage to comply with relevant local authority
end welded to and including 200 x 200 x 3mm base
36X9.8M

3,000
3,000
plate with 4 x 18mm diameter holes; other welded to and SVP denotes soil vent pipe to be provided at the head of the drainage
31,842 including 150mm long x 100 x 50 x 3mm thick channel
STALLS piece. 300X300mm R.C Stub columns to S.E detail Drains pass beneath buildings & driveways to be encased in 150mm
600x600x50 Precast paving slabs on well compacted concrete surround.
ground to approved sample. The storm drain pipes to comply with BS 556 specification.

600

500
500
G.L G.L All underground foul and waste drain pipes shall be uPVC to comply
HOPS FOUNDATION NOTES
1. RC Pad foundation to SE details. with BS 5255.

100
B A All inspection chambers covers and framing shall be cast iron.
PROPOSED SHED 3 2. 150mm thick well compacted hardcore.
3. 50mm murram blinding compacted to SE Minimum slope in the drains pipes to be 1 in 100
36X9.8M approval.
Section X - X 4. 100g DPM to approval.
5. 600x600mm precast concrete slabs.
Elevation E-O1 system
No chases will be allowed for pipes. Sleeves will be allowed with
written approval of structural Eng's. No cutting of concrete without
6. Premise or equally approved antitermite express approval of the Architect or structural Eng.
treatment.
All testing of pipes must be completed before plastering.
All mechnical works must be co-odinated with electrical and any
existing conflict must be clarified be work begin.
6,067
paving 6,202
blocks FINISHES
1 2 3 4 5 6 7 8 9 All doors and windows to have parmanent ventilations(PV )

.X
TOILETS
IC

ACESS ROAD IC TOILETS 35,200 All floor finishes to be cement/sand screed unless otherwise
instructed
300
4,250 4,400 4,400 4,400 4,400 4,400 4,400 4,400
PROPOSED SHED 4 ACESS ROAD 300
4,100
300
4,100
300
4,100
300
4,100
300
4,100
150 150
4,100
300
4,100
300
4,100
300

18X9.8M B B

300
REVISI0NS
IC

EXISTING SHED CLEANSHELF


SUPERMARKET

PROPOSED SHED 5 Project:


IC

E-01
18X9.8M
9,000 VENDORS

8,400

9,000
STALLS IC

43,877 600x600x50mm precast


45,983 concrete slabs
PROPOSED UPGRADING OF
KERUGOYA FOOD MARKET
PROPOSED SHED 7

IC

PROPOSED SHED 6 200 x 200mm thick R.C footing on 600x200 mm


18X9.8M

thick conc strip foundation to eng's details


IC
existing 18X9.8M Drawing Title:
paving
A A LAYOUT PLAN, MARKET SHED
300

blocks PLANS, SECTIONS,


4,400 4,400 4,400 4,400 4,400 4,400 4,400 4,400
IC IC IC

1 2 3 4 5 6 7 8 9 ELEVATIONS
35,500
SEPTIC TANK FLOOR LAYOUT PLAN
SOAK
Application:

.X
MH MH

PIT

IC
IC

23,872
IC

22,495 3,284 Client:

REVENUE
STALLS Project NO : Drg NO :
OFFICE 5,500
STALLS 28 gauge IT4 roofing sheets on Steel
trusses to S.E detail. Scales: A D
36,000 Pitch = 22.50 B E
2,800 open drain to be covered C F
open drain to be covered

27,001 29,200

ACESS ROAD
Name Signature Date
Designed by
5,100

County Architect
Drawn H. K.G
P.M Dir. Public Works 30.07.2018

SHOPS
MINISTRY OF TRANSPORT,

10,200
ROADS & PUBLIC WORKS

DIRECTORATE OF PUBLIC
WORKS
5,100

(KIRINYAGA COUNTY)

36,000 KENYA URBAN SUPPORT PROGRAM


ROOF PLAN

GSPublisherVersion 0.0.100.100
120mm Thick RC cover slab. NOTES

450X600mm MANHOLE 450X600mm MANHOLE


COVER & FRAME. COVER & FRAME. GENERAL

GL GL GL All dimensions are in mm unless otherwise specified.


Drawing are not to scalled. Only figured dimensions to be
used
INLET The contractor must check and verify all demensions before
MANHOLE 100 OUTLET
commencement of any work.

500 300
MANHOLE 150mm Thick TWL 200mm Thick CONSTRUCTION
TWL 100 masonry wall. R.C. wall. All slab at ground level to be poured over 1000 guage polythene

300
sheet on 50mm thick murram blinding on hardcore.

500
200mm Thick A B C All soil under slab around and under foundation to be poisoned
R.C. Wall . 150mm Thick for termite control.

F2
F1
12mm Thick Plaster Concrete Slab E All soil on cut embarkment to be stablized.The slope not to
Finish with water Mix 1:2:4. exceed the natural angle of repose

Repellant additives .

150
400 STRUCTURAL

150
All black cotton soil to be removed from all buildings and paved
400
For all R.C work,refer to stuctural Engineer's details.

SECTION K-K
SECTION X-X CIVIL
Depth of foundation to be detemined on site to S.E's aproval

Lightly Compacted suitable All walls less than 150mm thick to be reinforced with hoop iron at
every alternate course.
Sport Fillings.
GL GL All adjacent R.C. work and masonry walls to be tied with hoop iron
at every alternate course.
surfaces
1,000 MECHANICAL
Compacted Murram.

K1

200
All plumbing and drainage to comply with relevant local authority
Polythene Sheet or appropriately SVP denotes soil vent pipe to be provided at the head of the drainage
approved material.

600
Drains pass beneath buildings & driveways to be encased in 150mm
Crushed Stones. concrete surround.
The storm drain pipes to comply with BS 556 specification.
6'' Perforated cly or pitch fibre pipes

200
All underground foul and waste drain pipes shall be uPVC to comply
600mm long with 50mm open joints. with BS 5255.

X3 450X600MM 450X600MM X3 All inspection chambers covers and framing shall be cast iron.
Minimum slope in the drains pipes to be 1 in 100

600
FRENCH DRAIN DETAIL
MANHOLE

E
MANHOLE system
COVER TO FRENCH DRAIN No chases will be allowed for pipes. Sleeves will be allowed with
COVER
OR SOAKPIT AS SPECIFIED. written approval of structural Eng's. No cutting of concrete without
express approval of the Architect or structural Eng.

200
A B C GL GL All testing of pipes must be completed before plastering.
All mechnical works must be co-odinated with electrical and any
conflict must be clarified be work begin.
150mm Thick
200 200 200 200 1,000 masonry wall.
800 D 800 FINISHES

K1

H
All doors and windows to have parmanent ventilations(PV )
150mm Thick Stone blocks All floor finishes to be cement/sand screed unless otherwise
to drain invert. instructed

PLAN 'H' SOAKPIT DEPTH VARIES AS SPECIFIED OR


DIRECTED IN THE DRAWING.
REVISI0NS

SOAK PIT DETAIL

NUMBER DESLUDGE Project:


CAPACITY DIMENSIONS (MM)
OF INTERVALS
IN LITRES PROPOSED UPGRADING OF
PERSONS IN YEARS A B C D E F1 F2 KERUGOYA FOOD MARKET
3,000 10 2 800 1000 1000 3000 800 1500 1400
6,000 20 2 800 1400 1200 3600 1400 1500 1400 Drawing Title:

9,000 30 2 800 1400 1200 3600 1800 1500 1300 SEPTIC TANK DETAILS
12,000 40 2 800 1600 1400 4000 2000 1500 1300
15,000 50 2 800 1600 1400 4000 2400 1500 1200 Application:

22500 100 1.5 800 3600 1800 5600 3000 1850 1500 Client:

45000 200 1.5 800 5600 2800 8600 3600 2040 1500 Project NO : Drg NO :
A
67500 300 1.5 800 7600 3800 11600 4000 2260 1500 Scales:
B
C
D
E
F
90000 400 1.5 800 8800 4400 13400 4600 2380 1500

Name Signature Date


NOTES Designed by
Drawn
County Architect
H. K.G
P.M Dir. Public Works 30.07.2018

1. COVER SLAB TO BE REINFORCED WITH 10MM BARS AT 100MM CRS


MINISTRY OF TRANSPORT,
[CONC 20/20 MIX 1:2:4]. ROADS & PUBLIC WORKS

2. BASE SLAB TO BE CONCRETE CLASS Q MIX 1:3:6. DIRECTORATE OF PUBLIC


WORKS
3.INLET AND OUTLET PIPES TO BE 100MM DIAMETER CAST IRON PIPES. (KIRINYAGA COUNTY)

4. SCUM BUFFLE TO BE 100MM THICK R.C WITH MESH WIRE BOTH SIDES.
5. DIVIDING WALL TO BE 100MM THICK CONCRETE CLASS 20/20 REINFORCED WITH
KENYA URBAN SUPPORT PROGRAM
WELDMESH No. 65.

GSPublisherVersion 0.0.100.100