Objective : To ensure that the Puri ed Water Distribution System is Chemically cleaned.
Procedure :
Fill the Puri ed Water Storage Tank till the Half Level.
Ensure Suction & Discharge valve of pump are open and all user points & sampling valves are closed.
Then drain the water from the tank & piping via user points & sampling points.
Prepare Cleaning chemical by diluting Nitric acid (HNO3) of 2% concentration in Puri ed Water.
Start the recirculation pump and circulate the cleaning chemical for 45-60 min.
Then drain the cleaning chemical from the tank & piping via user points & sampling points.
Prepare Passivation chemical by diluting Sodium Hydroxide (NaOH) (of 100% purity) with water with 1% of concentration.
Start recirculation pump and circulate the Passivation chemical for not less than
1 hr.
Drain the Passivation chemical from equipments and recirculation loops via each user points.
Flush the equipment and recirculation loops with puri ed water till the pH is neutral (6 to 7) or to the in feed water quality.