Objective:To lay down a procedure for Preventive Maintenance of Puri ed Water System (Generation and Distribution).
Scope:This Standard Operating Procedure is applicable for formulation plant of pharmaceutical company.
Responsibility
The Concerned Technician shall follow the procedure for Preventive Maintenance as per this SOP.
The O cer/Executive-Engineering shall be responsible for implementation of this procedure as per this SOP.
RO – Reverse Osmosis
TC – Tri Coupling
Procedure:
Monthly Schedule
Switch “OFF” the main power supply through MCC and hang the Preventive Maintenance Display Board on the electrical control panel.
Check and note the reading of hour meters of all UV lamps and change the UV lamp between 7200 hours to 7500 hours.
Clean all S. S. visible part of puri ed water system by coline and cloth properly.
Checked, all pressure gauges for proper functioning, if not working, replace with same range calibrated gauge.
Check all TC joints for leakages, if leakage found change its silicon gasket.
Checked dosing pump, cleaned its suction & discharge pipe with air & water pressure.
Check all electrical connections, MCB, push button & switches for proper functioning. Rectify if required
Clean the Pre lter and air vent lter if required. Change the Pre lter if pressure gauge (PI001) shows measure pressure drop upto 2 bar.
Check all pumps for any leakages and smooth operation, rectify if found any abnormality.
Check the all motors for the loose connection and smooth operation and apply grease on the bearing and change the bearing if
necessary.
Yearly Schedule
Check all pneumatic valve for proper functioning change if found faulty.
Change the Pre lter and Vent lter with a new lter after every 2 years.
Change MCF lter after every two years or as and when required.
Record all the observations in Preventive Maintenance Checklist (Annexure-1).
Forms and Annexure:
Distribution
Controlled Copies : Engineering, Quality Assurance, Production,Warehouse, Quality Control, Administration and House keeping
8.0 History
Revision
Date Reason for Revision
Number
– 00 New SOP