You are on page 1of 29

Internal Only▲

Configuration and Commissioning NEC


iPASOLINK VR4

Nay Zin Tun


MW engineer
Internal Only▲

LOGIN TO iPasolink Equipment.

Put this IP in internet explorer

User Name: Admin


Password: 12345678

Use No IP in your Laptop Internet


Configuration. It Must be automatically
Internal Only▲

Main Window Equipment View. It will tell us which type IDY, How
many Modems and How many ODUs connected.
-Green Color = No Alarms
-Orange Color = Alarms

Current Alarms will be shown here

Menu`s
Internal Only▲

Equipment Configuration (Change NE ID, Add Modems, Make XPIC or 1+1 Group)

Click on “Setup”
to start
configuration.
Internal Only▲

Change NE Name

Type NE name here and use same format. Don’t


write link ID .Only mention station ID
e.g: site_id-iPaso (200/400/1000/VR 4)-1 (1
represent the sequence number of IDU on same
station. If there are two IDU write “1” on upper
IDU and write “2” on second IDU and so on.).
Click Next
Internal Only▲

Pluggable Module (Modem etc) Detection

If new modem card or any other card used,


click on “Auto Detect” or select manually
from the drop down list. Otherwise you
cannot use new cards.
Click Next
Internal Only▲

Link Configuration (Configure Link as 1+1 HSB, XPIC using pairing slots i-e 1 & 2 make one pair and 3 & 4 Make one pair)

Select link configuration from the drop


down list.
Note: For 1+1 link configuration make
sure the license is available otherwise
you cannot select 1+1 configuration.
Internal Only▲

Finish Equipment Configuration

Click “OK” button after finish.


Internal Only▲

Radio Configuration:(For configuring Link Frequency, Modulation and Channel Bandwidth/Spacing)

Put Channel bandwidth and


1 Modulation scheme here

Put TX Frequency
here
Do not Change any other parameter except the
above mentioned three. Click Next and Ok to
Complete
3
Internal Only▲

Configure TX Power

Put TX power here


2

1 3
Internal Only▲

Check RSL. (After Alignment starts)

Click on Metering-> Current Metering


Click on MODEM to check the RSL change
during Alignment.

RSL will be shown here. If no alignment RSL is above -95 db

1
Adding IP address(1) Internal Only▲

2
3

Set IP, Subnet Mask and GW as per given DCN plan and check
“connect NMS port to NMS” to yes for IDU which is connected
to PTN
Adding IP address(2) Internal Only▲

4
1

Add NMS VLAN according to DCN plan


Internal Only▲

Change Inband NMS Setting


Make Inband Managmend “used”
Enter VLAN ID according to DC plan ”
Choose CoS “7” from drop Down Menu

Click “OK”

2
Internal Only▲

Enable Ethernet Port


-Click Enable
-Choose Speed.(for BBU its 100, for other is Auto
-Flow Control Disable
2-Click on the port which you want to
use

1
Internal Only▲

Add VLAN for NMS. (only add at the port which is connected to PTN)
First Add VLAN ID in the system

2 Give VLAN ID “2005”, VLAN ID need to add according


to plan
Service Name “NMS”
3 Click OK

1
Internal Only▲

Add VLAN for NMS. (only add at the port which is connected to PTN)
Then Assign VLAN to the Ports

Give VLAN ID “2005”


Service Name “NMS”
1 Click OK

Click on Port 2(which you enable


to connect to PTN)

Check the VLAN 2005


Click OK
Internal Only▲

Add VLAN for site (Add 2G & 3G VLAN IDs in system)

2
Give VLAN ID and service Name
Click OK
3
1
Internal Only▲

Add VLAN for site (Assign VLAN to relative Modem and Ethernet Ports)

Click on Modem and FE port and


assign 2G 3G VLANs to them

Check the VLAN IDs for 2G 3G


and click OK
Internal Only▲

Set Date and Time

Check on Display PC Time and Click OK


Internal Only▲

NMS Setting Service Setting

Click on User
Account/ Security
Setting->Security
Management-
>Service Status
Setting.

Service Status
Summary. Should
be same as here.
Internal Only▲

SNMP Setting.

Click on “SNMP”
and enable SNMP
V1, SNMP V3.
Set UDP port to
161.
Internal Only▲

SNMP Community

Click on “SNMP
Community” and set:
Community Name:
“public”
Access Level: Admin.
Access Control: Enable
Service IP Address:
0.0.0.0
Subnet Mask:
0.0.0.0
Internal Only▲

SNMP Trap Entry and NTP

SNMP Trap Entry


: No change.
NTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲

NTP Server Address and FTP


SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲

FTP setting
SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲

SFTP, HTTP and HTTPS

SFTP : Stopped
HTTP: Running
and TCP port is
80.
HTTPS: Stopped
Internal Only▲

Configuration for AMR setting(AMR setting need to configuration when the site
integration finished,don't configure before the antenna alignment not finish)

Start Modulation must choose from


QPSK to Planed Modulation

End Modulation must choose


accoriding to LB's Modualation
Internal Only▲

Thanks

You might also like