Main Window
Equipment Configuration (Change NE ID, Add Modems, Make XPIC or 1+1 Group)
Click on “Setup”
to start
configuration.
Internal Only▲
Change NE Name
Link Configuration (Configure Link as 1+1 HSB, XPIC using pairing slots i-e 1 & 2 make one pair and 3 & 4 Make one pair)
Put TX Frequency
here
Configure TX Power
3
Internal Only▲
Change NMS IP
Set IP, Subnet Mask and GW as per given DCN plan and check
“connect NMS port to NMS” to yes for IDU which is connected
to PTN
Internal Only▲
Click “OK”
1
Internal Only▲
-Click Enable
2-Click on the port which you want to -Choose Speed.(for BBU its 100, for other is Auto
use -Flow Control Disable
1
Internal Only▲
Add VLAN for NMS. (only add at the port which is connected to PTN)
First Add VLAN ID in the system
1
Internal Only▲
Add VLAN for NMS. (only add at the port which is connected to PTN)
Then Assign VLAN to the Ports
2
Give VLAN ID and service Name
Click OK
3
1
Internal Only▲
Add VLAN for site (Assign VLAN to relative Modem and Ethernet Ports)
1
Internal Only▲
Click on User
Account/ Security
Setting->Security
Management-
>Service Status
Setting.
Service Status
Summary. Should
be same as here.
Internal Only▲
SNMP Setting.
Click on “SNMP”
and enable SNMP
V1, SNMP V3.
Set UDP port to
161.
Internal Only▲
SNMP Community
Click on “SNMP
Community” and set:
Community Name:
“public”
Access Level: Admin.
Access Control: Enable
Service IP Address:
0.0.0.0
Subnet Mask:
255.255.255.255
Internal Only▲
SNMP Trap
Entry : No
change.
NTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲
SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲
SFTP : Stopped
HTTP: Running
and TCP port is
80.
HTTPS: Stopped
Internal Only▲