Professional Documents
Culture Documents
TECHNOLOGY
P9010 & P9010e TURBOJET ENGINE TEST STAND
EXPERIMENTAL CAPABILITY
Demonstration of the Turbo jet principle
Performance analysis of a Turbojet at varying power
INTRODUCTION
Turbojets are used as high performance jet engines in
aircrafts and to provide the core of the very successful
turbofan engines used on the great majority of airliners.
Cussons Turbojet Engine Test Stand provides a fully
functioning, aero derivative small jet turbine. The jet turbine
thrust can be measured and outputs up to 230N can be
achieved.
DESCRIPTION
A tailpipe ducts the gas into a thrust producing jet. The
Cussons have developed a turbo jet engine test stand to turbine uses ceramic bearings eliminating the need for
provide a cost effective method of testing the performance lubricating oil.
of an operational aero jet engine. The turbo jet test stand is Air is ducted into the engine via a calibrated nozzle such that
mounted on a wheeled trolley allowing it to be moved to an air mass volume can be determined, and fuel is pumped into
operational area or stored in a convenient location. the engine by a small electrically driven gear pump.
The test stand provides a fully functioning and instrumented The pump is precisely controlled by the Engine Control Unit so
engine. The engine used incorporates a single stage as to directly control the engine speed. Operator control is
centrifugal compressor, feeding air into a combustion provided by a throttle lever. Fuel is in the form of kerosene,
chamber fed by multiple fuel injectors, and through to a with a lubricant mix, and starting is provided with a
single stage centrifugal turbine. decoupling electric starter.
PURCHASE SPECIFICATION
A trolley mounted single shaft turbojet designed for flight is to
be supplied so as to demonstrate the turbojet principle. It is
to be instrumented, so as to all allow a performance analysis
of the turbojet at various speeds to be undertaken.
The unit should alternatively be provided with a physical
mimic diagram plate or be instrumented for data acquisition
and a digital mimic diagram.
INSTALLATION REQUIREMENTS
Exhaust duct with very low back pressure (or a safe vent
directly to an outside area). INSTALLATION REQUIREMENTS
It is recommended that a safe cordon of 10 metres be Single phase power supply (please specify when
enforced around the rear of the unit, which should vent ordering)
into or be open to atmosphere.
Head Office
Cussons Technology Limited
102 Great Clowes Street,
Manchester.
M7 1RH England
Tel: + (44)161 833 0036
Fax: + (44)161 834 4688
E-mail: sales@cussons.co.uk