Self-Contained Packaged
Gas/Electric System
Model RG 024 to 120 (2 to 10 tons)
Model RE 090 to 120 (71⁄2 to 10 tons)
This document contains the most current product information as of this printing. For the most up-to-date product
information, please go to www.mcquay.com.
1
RG 10 SEER/80% AFUE Self-Contained Packaged
Gas/Electric
2 – 5 Ton
Single-Phase and 3-Phase
Packaged gas/electric unit allows for ground-level or
rooftop mount, horizontal or downflow application.
Standard Features
Energy-efficient compressor
Copper tube/aluminum fin coil
Liquid line filter drier
Fully charged R-22 system
Durable, corrosion-resistant T-140 aluminized steel
tubular heat exchanger
Redundant gas valve, natural gas and easy
conversion to propane
Power-assisted combustion
Cooling Capacities: 24,000 to 57,000 BTUH
Direct spark ignition system, which includes a
microprocessor-based control for the entire ignition Heating Capacities: 46,000 to 138,000 BTUH
sequence, all blower operation and all equipment
protection circuits complete with self-diagnostics
All models fit in a standard-size pick-up truck (47"
wide)
Horizontal or downflow application
One roof curb fits all units
California low NOx approved
Filters must be field installed in the return grills or in
the unit using the filter rack accessory.
Cabinet Construction
Convenient access panels
High-quality UV-resistant powder-paint finish
Fully insulated
Bottom, 2" high base rails for easier handling
When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
Accessories
Roof curb
25% manual and motorized fresh air dampers
Downflow and horizontal economizers
Square to round converter
L.P. Conversion Kit
Room Thermostat
See “Accessories” for a complete listing of accessories
Model Nomenclature
RG 024 A A A R Y
2
Specifications - Single Phase Units
RG024AAARY RG024AABRY RG030AABRY RG036AABRY RG036AACRY RG042AABRY
Total Cooling Capacity, BTUH 24,000 24,000 29,600 35,200 35,200 40,000
Sensible Cooling Capacity, BTUH 18,400 18,400 22,800 27,400 27,400 31,200
EER¹ 9.4 9.4 9.0 9.3 9.3 9.4
SEER 10.0 10.0 10.0 10.0 10.0 10.0
Sound Rating, dba 76.0 76.0 76.0 76.0 76.0 76.0
Heating Input, BTUH (US) 46,000 69,000 69,000 69,000 92,000 69,000
Heating Output, BTUH (US) 36,700 55,000 55,000 55,000 72,900 55,000
AFUE 80 80 80 80 80 80
Temperature Rise 30 - 60 35 - 65 35 - 65 35 - 65 45 - 75 35 - 65
Number of Burners 2 3 3 3 4 3
Orifice Size Natural/Propane 43/55 43/55 43/55 43/55 43/55 43/55
Indoor Blower
Type DD DD DD DD DD DD
Blower Wheel (D x W) 10" x 8 10" x 8 10" x 8 10" x 9 10" x 9 11" x 10"
Nominal CFM (ID) 850 850 1,050 1,250 1,250 1,425
Motor Speed Tap (Cooling) Low Low Med-Lo Med-Hi Med-Hi Med
RPM/Amps (Cooling) 885/1.2 885/1.2 965/1.5 1,040/1.8 1,040/1.8 940/2.5
Horsepower/RPM 1/3/1,080 1/3/1,080 1/3/1,080 1/3/1,080 1/3/1,080 3/4/1,100
Evaporator Coil
Face Area (ft²) 3.67 3.67 3.67 4.33 4.33 4.33
Rows Deep/Fins per Inch 2/14 2/14 2/14 2/14 2/14 4/14
Piston Size (Cooling) 0.057 0.057 0.065 0.071 0.071 0.076
Filter Size (ft²) 2.8 2.8 3.5 4.2 4.2 4.8
Drain Size (NPT) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4"
Refrigerant Charge (oz.) 50 50 50 75 75 88
Condenser Fan
Horsepower/RPM 1/6/1,075 1/6/1,075 1/6/1,075 1/4/1,075 1/4/1,075 1/4/1,075
Fan Diameter/Number of Fan Blades 22/3 22/3 22/3 22/3 22/3 22/3
Nominal CFM (OD) 2,400 2,400 2,400 2,700 2,700 2,700
Condenser Coil
Face Area (ft²) 7.8 7.8 7.8 12.4 12.4 12.4
Rows Deep/Fins per Inch 1/19 1/19 1/19 1/19 1/19 1/19
Electrical
Volts/Phase/Frequency 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Compressor RLA/LRA 9.8/56.0 9.8/56.0 13.7/75.0 14.9/96.0 14.9/96.0 16.2/96.0
Indoor Blower FLA/LRA 1.9/3.6 1.9/3.6 1.9/3.6 2.1/3.6 2.1/3.6 2.6/5.0
Outdoor Fan RLA/LRA 1.1/1.8 1.1/1.8 1.1/1.8 1.8/3.8 1.8/3.8 1.8/3.8
Total Unit Amps 11.3 11.3 14.9 18.5 18.5 19.5
Minimum Circuit Ampacity 15.3 15.3 20.2 22.6 22.6 24.7
Maximum Overcurrent Protection² 20 20 30 30 30 40
Electrical Entrance Size
Power Supply 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8”
Control Voltage 7/8” 7/8” 7/8” 7/8” 7/8” 7/8”
Shipping Weight (lbs) 386 391 397 445 450 459
Operating Weight (lbs) 364 369 375 423 428 437
3
Specifications - Single Phase Units - continued
RG042AACRY RG048AACRY RG048AADRY RG060AACRY RG060AAERY
Total Cooling Capacity, BTUH 40,000 47,000 47,000 56,000 56,000
Sensible Cooling Capacity, BTUH 31,200 36,200 36,200 43,600 43,600
EER¹ 9.4 9.1 9.1 9.0 9.0
SEER 10.0 10.0 10.0 10.0 10.0
Sound Rating, dba 76.0 76.0 76.0 76.0 76.0
Heating Input, BTUH (US) 92,000 92,000 115,000 92,000 138,000
Heating Output, BTUH (US) 72,900 72,900 91,200 72,900 110,200
AFUE 80 80 80 80 80
Temperature Rise 45 - 75 45 - 75 45 - 75 45 - 75 45 - 75
Number of Burners 4 4 5 4 6
Orifice Size Natural/Propane 43/55 43/55 43/55 43/55 43/55
Indoor Blower
Type DD DD DD DD DD
Blower Wheel (D x W) 11" X 10 11" X 10” 11" X 10” 11" X 10” 11" X 10"
Nominal CFM (ID) 1,425 1,525 1,525 1,950 1,950
Motor Speed Tap (Cooling) Med Med Med High High
RPM/Amps (Cooling) 940/2.5 990/3.1 990/3.1 1,080/4.7 1,080/4.7
Horsepower/RPM 3/4/1,100 3/4/1,100 3/4/1,100 3/4/1,100 3/4/1,100
Evaporator Coil
Face Area (ft²) 4.33 5.67 5.67 5.67 5.67
Rows Deep/Fins per Inch 4/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) 0.076 0.08 0.08 0.092 0.092
Filter Size (ft²) 4.8 5.1 5.1 6.2 6.2
Drain Size (NPT) 3/4” 3/4” 3/4” 3/4” 3/4"
Refrigerant Charge (oz.) 88 98 98 100 100
Condenser Fan
Horsepower/RPM 1/4/1,075 1/3/1,075 1/3/1,075 1/3/1,075 1/3/1,075
Fan Diameter/Number of Fan Blades 22/3 22/3 22/3 22/3 22/3
Nominal CFM (OD) 2,700 3,500 3,500 3,500 3,500
Condenser Coil
Face Area (ft²) 12.4 15.3 15.3 15.3 15.3
Rows Deep/Fins per Inch 1/19 1/19 1/19 1/19 1/19
Electrical
Volts/Phase/Frequency 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Compressor RLA/LRA 16.2/96.0 19.5/102.0 19.5/102.0 26.5/148.0 26.5/148.0
Indoor Blower FLA/LRA 2.6/5.0 4.7/12.2 4.7/12.2 4.7/12.2 4.7/12.2
Outdoor Fan RLA/LRA 1.8/3.8 2.4/5.2 2.4/5.2 2.4/5.2 2.4/5.2
Total Unit Amps 19.5 23.2 23.2 29.6 29.6
Minimum Circuit Ampacity 24.7 31.5 31.5 40.3 40.3
Maximum Overcurrent Protection² 40 50 50 60 60
Electrical Entrance Size
Power Supply 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8”
Control Voltage 7/8” 7/8” 7/8” 7/8” 7/8”
Shipping Weight (lbs) 464 518 525 534 548
Operating Weight (lbs) 442 496 503 512 526
4
Specifications-3-Phase Units
RG036AACPY RG048AACPY RG060AACPY RG060AAEPY
Total Cooling Capacity, BTUH 35,200 47,000 56,000 56,000
Sensible Cooling Capacity, BTUH 27,400 36,200 43,600 43,600
EER¹ 9.3 9.1 9.0 9.0
SEER 10.0 10.0 10.0 10.0
Sound Rating, dba 76.0 76.0 76.0 76.0
Heating Input, BTUH (US) 92,000 92,000 92,000 138,000
Heating Output, BTUH (US) 72,900 72,900 72,900 110,200
AFUE 80 80 80 80
Outdoor Steady State Efficiency 82.6 82.6 82.6 83.1
Temperature Rise 45 - 75 45 - 75 45 - 75 45 - 75
Number of Burners 4 4 4 6
Orifice Size Natural/Propane 43/55 43/55 43/55 43/55
Indoor Blower
Type DD DD DD DD
Blower Wheel (D x W) 11" X 10" 11" X 10" 11" X 10" 11" X 10"
Nominal CFM (ID) 1,250 1,525 1,950 1,950
Horsepower/RPM 3/4/1,100 3/4/1,100 3/4/1,100 3/4/1,100
Evaporator Coil
Face Area (ft²) 5.67 5.67 5.67 5.67
Rows Deep/Fins per Inch 2/14 4/14 4/14 4/14
Piston Size (Cooling) 0.071 0.08 0.092 0.092
Filter Size (ft²) 4.3 5.4 6.8 6.8
Drain Size (NPT) 3/4” 3/4” 3/4” 3/4"
Refrigerant Charge (oz.) 75 98 100 100
Condenser Fan
Horsepower/RPM 1/4/1,075 1/3/1,075 1/3/1,075 1/3/1,075
Fan Diameter/Number of Fan Blades 22/3 22/3 22/3 22/3
Nominal CFM (OD) 2,700 3,500 3,500 3,500
Condenser Coil
Face Area (ft²) 15.3 15.3 15.3 15.3
Rows Deep/Fins per Inch 1/19 1/19 1/19 1/19
Electrical
Volts/Phase/Frequency 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60
Compressor RLA/LRA 8.9/63.0 12.6/91.0 17.3/123.0 17.3/123.0
Indoor Blower FLA/LRA 2.6/5.0 4.7/12.2 4.7/12.2 4.7/12.2
Outdoor Fan RLA/LRA 1.8/3.8 2.4/5.2 2.4/5.2 2.4/5.2
Minimum Circuit Ampacity 15.6 22.9 25.8 25.8
Maximum Overcurrent Protection² 20 30 40 40
Electrical Entrance Size
Power Supply 1-1/8” 1-1/8” 1-1/8” 1-1/8”
Control Voltage 7/8” 7/8” 7/8” 7/8”
Shipping Weight (lbs) 500 518 534 548
Operating Weight (lbs) 478 496 512 526
5
Evaporator Blower Specifications
RG 10 SEER - 2 to 2-1/2 Ton Models
Motor
HIGH MED-HIGH MED LOW
Speed
E.S.P. CFM Watts RPM Amps CFM Watts RPM Amps CFM Watts RPM Amps CFM Watts RPM Amps
0.1 1,436 492 995 2.18 1,347 451 960 1.95 1,149 385 844 1.65 935 301 697 1.35
0.2 1,365 474 1,003 2.05 1,292 432 982 1.88 1,111 365 867 1.58 903 293 769 1.29
0.3 1,301 453 1,024 1.98 1,233 419 988 1.81 1,054 349 904 1.53 853 281 812 1.25
0.4 1,227 431 1,042 1.80 1,156 398 1,000 1.74 1,011 340 936 1.47 831 281 866 1.21
0.5 1,149 415 1,057 1.73 1,099 383 1,037 1.67 954 326 978 1.41 780 268 897 1.16
0.6 1,065 395 1,071 1.69 1,014 361 1,041 1.58 890 308 1,004 1.34 717 254 936 1.1
0.7 981 375 1,085 1.65 939 346 1,072 1.52 824 295 1,033 1.28 665 245 965 1.05
0.8 895 354 1,099 1.61 835 322 1,092 1.44 737 276 1,047 1.2 575 228 1,016 0.98
6
Dimensions
47
51
18 7/16
FLUE EXHAUST 16 A
1 3/8
5 1/2
16
7 15/16 B
2 3/4
SUCTION/LIQUID PRESSURE PORTS
BEHIND COMPRESSOR ACCESS PANE
RETURN
B
HEAT EXCHANGE ACCESS PANE
4 3/4
SUPPLY GAS ENTRANCE
SUPPLY
CONDENSATE DRAIN CONNECTION 3
3/4" NPT FEMALE
7 5/16
7 7/8
DIMENSIONS SMALL
DIMENSION SMALL MEDIUM LARGE MEDIUM
(INCHES)
(INCHES)
A 27 32 40
B
A 16 16
27 18
32 40
POWER WIRE ENTRANCE B 16 16 16
CONTROL WIRE ENTRANCE
RETURN
11
22
22
11
7
Roof Curb Dimensions
42 5/8
15 x 22 1/2
3 Supply
49 1/2 x2 14 1/2
1/2 n
12 etur
R
1 5/8
14 1/2
1 3/8
Specifications:
1. Constructed of 18 gauge galvanized steel.
2. Features a 1" x 4" wood runner permanently attached to the top of the curb.
3. Shipped unassembled with all hardware and instructions necessary for
installation.
Accessories
Part Number Description
PGC101-103 Roof Curb
PGED101-2 Downflow Economizer, Small and Medium Chassis - see note 1
PGED103 Downflow Economizer, Large Chassis - see note 1
PGEH101-3 Horizontal Economizer, Small and Medium Chassis - see note 2
PGEH103 Horizontal Economizer, Large Chassis - see note 2
PGMDD101-2 Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis
PGMDD103 Manual 25% Fresh Air Damper Downflow Application, Large Chassis
PGMDH101 Manual 25% Fresh Air Damper Horizontal Application, Small Chassis
PGMDH102 Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis
PGMDH103 Manual 25% Fresh Air Damper Horizontal Application, Large Chassis
PGMDMD1012 Motorized 25% Fresh Air Damper Downflow Application, Small and Medium Chassis
PGMDMD103 Motorized 25% Fresh Air Downflow Application, Large Chassis
PGMDMH101 Motorized 25% Fresh Air Damper Horizontal Application, Small Chassis
PGMDMH102 Motorized 25% Fresh Air Damper Horizontal Application, Small and Medium Chassis
PGMDMH103 Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis
SQRPG101-2 Square to Round Adapter with 16" Round Downflow Application, Small and Medium Chassis
SQRPG103 Square to Round Adapter with 18" Round Downflow Application, Large Chassis
PGFR101-2 Internal Filter Rack All Chassis - not available with downflow economizer
8
RG 12 SEER/80% AFUE Self-Contained Packaged
Gas/Electric
2 – 5 Ton
Packaged gas/electric unit allows for ground-level or
rooftop mount, horizontal or downflow application.
Single-Phase
Standard Features
High-efficiency compressor
Copper tube/aluminum fin coil
Liquid line filter drier
Fully charged R-22 system
Durable, corrosion-resistant T-140 aluminized steel
tubular heat exchanger
Redundant gas valve, natural gas and easy
conversion to propane
Power-assisted combustion
Direct spark ignition system, which includes a Cooling Capacities: 24,000 to 56,000 BTUH
microprocessor-based control for the entire ignition Heating Capacities: 46,000 to 115,000 BTUH
sequence, all blower operation and all equipment
protection circuits complete with self-diagnostics
All models fit in a standard-size pick-up truck
(47” wide)
Horizontal or downflow application
One roof curb fits all units
California low NOx approved
Filters must be field installed in the return grills or in
the unit using the filter rack accessory.
Cabinet Construction
Convenient access panels
High-quality UV-resistant powder-paint finish
Fully insulated
Bottom, 2" high base rails for easier handling
When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
Accessories
Roof curb
25% manual and motorized fresh air dampers
Downflow and horizontal economizers
Square to round converter
L.P. Conversion Kit
Room Thermostat
See “Accessories” for a complete listing of accessories
Model Nomenclature
RG 024 A B A R Y
9
Specifications
RG024ABARY RG024ABBRY RG030ABBRY RG036ABBRY RG036ABCRY RG042ABBRY
Total Cooling Capacity, BTUH 24,000 24,000 29,000 35,800 35,800 40,600
Sensible Cooling Capacity, BTUH 18,200 18,200 22,600 27,800 27,800 31,600
EER¹ 10.6 10.6 10.6 10.4 10.4 10.4
SEER 12.0 12.0 12.0 12.0 12.0 12.0
Sound Rating, dba 76.0 76.0 76.0 76.0 76.0 76.0
Heating Input, BTUH (US) 46,000 69,000 69,000 69,000 92,000 69,000
Heating Output, BTUH (US) 36,700 55,000 55,000 55,000 72,900 55,000
AFUE 80 80 80 80 80 80
Temperature Rise 30 - 60 35 - 65 35 - 65 35 - 65 45 - 75 35 - 65
Number of Burners 2 3 3 3 4 3
Orifice Size Natural/Propane 43/55 43/55 43/55 43/55 43/55 43/55
Indoor Blower
Type DD DD DD DD DD DD
Blower Wheel (D x W) 10" x 8" 10" x 8" 10" x 8" 10" x 9" 10" x 9" 11" x 10"
Nominal CFM (ID) 800 800 1,000 1,250 1,250 1,400
Motor Speed Tap (Cooling) Low Low Med-Lo Med-Hi Med-Hi Med
RPM/Amps (Cooling) 970/1.1 970/1.1 1,000/1.4 1,070/1.7 1,070/1.7 940/2.5
Horsepower/RPM 1/3/1,080 1/3/1,080 1/3/1,080 1/3/1,080 1/3/1,080 3/4/1,100
Evaporator Coil
Face Area (ft²) 3.67 3.67 3.67 4.33 4.33 4.33
Rows Deep/Fins per Inch 3/14 3/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) 0.059 0.059 0.062 0.071 0.071 0.078
Filter Size (ft²) 2.7 2.7 3.3 4.2 4.2 4.7
Drain Size (NPT) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
Refrigerant Charge (oz.) 64 64 73 85 85 105
Condenser Fan
Horsepower/RPM 1/6/850 1/6/850 1/6/850 1/4/1,075 1/4/1,075 1/4/1,075
Fan Diameter/Number of Fan Blades 22/3 22/3 22/3 22/3 22/3 22/3
Nominal CFM (OD) 2,400 2,400 2,400 2,700 2,700 2,700
Condenser Coil
Face Area (ft²) 10.5 10.5 10.5 12.4 12.4 12.4
Rows Deep/Fins per Inch 1/19 1/19 1/19 1/19 1/19 2/16
Electrical
Volts/phase/Frequency 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Compressor RLA/LRA 10.2/51.0 10.2/51.0 10.8/60.0 14.5/82.0 14.5/82.0 19.3/104.0
Indoor Blower FLA/LRA 1.9/3.6 1.9/3.6 1.9/3.6 2.1/3.6 2.1/3.6 2.6/5.0
Outdoor Fan RLA/LRA 0.8/1.7 0.8/1.7 0.8/1.7 1.8/3.8 1.8/3.8 1.8/3.8
Total Unit Amps 10.1 10.1 12.2 15.6 15.6 18.3
Minimum Circuit Ampacity 15.5 15.5 16.2 22.1 22.1 28.6
Maximum Overcurrent Protection² 20 20 30 30 30 40
Electrical Entrance Size
Power Supply 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8”
Control Voltage 7/8” 7/8” 7/8” 7/8” 7/8” 7/8”
Shipping Weight (lbs) 393 398 404 446 451 479
Operating Weight (lbs) 371 376 382 424 429 457
10
Specifications - continued
RG042ABCRY RG048ABCRY RG048ABDRY RG060ABCRY RG060ABDRY
Total Cooling Capacity, BTUH 40,600 47,000 47,000 55,000 55,000
Sensible Cooling Capacity, BTUH 31,600 35,400 35,200 42,800 42,800
EER¹ 10.4 10.6 10.6 10.4 11.0
SEER 12.0 12.0 12.0 12.0 12.0
Sound Rating, dba 76.0 76.0 76.0 76.0 76.0
Heating Input, BTUH (US) 92,000 92,000 115,000 92,000 115,000
Heating Output, BTUH (US) 72,900 72,900 91,200 72,900 91,200
AFUE 80 80 80 80 80
Temperature Rise 45 - 75 45 - 75 45 - 75 45 - 75 45 - 75
Number of Burners 4 4 5 4 5
Orifice Size Natural/Propane 43/55 43/55 43/55 43/55 43/55
Indoor Blower
Type DD DD DD DD DD
Blower Wheel (D x W) 11" x 10" 11" x 10" 11" x 10" 11" x 10" 11" x 10"
Nominal CFM (ID) 1,400 1,525 1,525 1,900 1,900
Motor Speed Tap (Cooling) Med Med Med High High
RPM/Amps (Cooling) 940/2.5 990/3.1 990/3.1 1,080/4.7 1,080/4.7
Horsepower/RPM 3/4/1,100 3/4/1,100 3/4/1,100 3/4/1,100 3/4/1,100
Evaporator Coil
Face Area (ft²) 4.33 5.67 5.67 5.67 5.67
Rows Deep/Fins per Inch 4/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) 0.078 0.084 0.084 0.089 0.089
Filter Size (ft²) 4.7 5.1 5.1 6.3 6.3
Drain Size (NPT) 3/4” 3/4” 3/4” 3/4” 3/4"
Refrigerant Charge (oz.) 105 116 116 128 128
Condenser Fan
Horsepower/RPM 1/4/1,075 1/3/1,075 1/3/1,075 1/3/1,075 1/3/1,075
Fan Diameter/Number of Fan Blades 22/3 22/3 22/3 22/4 22/4
Nominal CFM (OD) 2,700 3,500 3,500 3,500 3,500
Condenser Coil
Face Area (ft²) 12.4 15.3 15.3 15.3 15.3
Rows Deep/Fins per Inch 2/16 2/16 2/16 2/16 2/16
Electrical
Volts/phase/Frequency 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Compressor RLA/LRA 19.3/104.0 18.3/109.0 18.3/109.0 19.9/137.0 19.9/137.0
Indoor Blower FLA/LRA 2.6/5.0 4.7/12.2 4.7/12.2 4.7/12.2 4.7/12.2
Outdoor Fan RLA/LRA 1.8/3.8 2.4/5.2 2.4/5.2 2.4/5.2 2.4/5.2
Total Unit Amps 18.3 19.7 19.7 23.5 23.5
Minimum Circuit Ampacity 28.6 30 30 32 32
Maximum Overcurrent Protection² 40 40 40 50 50
Electrical Entrance Size
Power Supply 1-1/8” 1-1/8” 1-1/8” 1-1/8” 1-1/8”
Control Voltage 7/8” 7/8” 7/8” 7/8” 7/8”
Shipping Weight (lbs) 484 540 547 550 557
Operating Weight (lbs) 462 518 525 528 535
11
Evaporator Blower Specifications
RG 12 SEER - 2 to 2-1/2 Ton Models
Motor
HIGH MED-HIGH MED LOW
Speed
E.S.P. CFM Watts RPM Amps CFM Watts RPM Amps CFM Watts RPM Amps CFM Watts RPM Amps
0.1 1,436 492 995 2.18 1,347 451 960 1.95 1,149 385 844 1.65 935 301 697 1.35
0.2 1,365 474 1,003 2.05 1,292 432 982 1.88 1,111 365 867 1.58 903 293 769 1.29
0.3 1,301 453 1,024 1.98 1,233 419 988 1.81 1,054 349 904 1.53 853 281 812 1.25
0.4 1,227 431 1,042 1.80 1,156 398 1,000 1.74 1,011 340 936 1.47 831 281 866 1.21
0.5 1,149 415 1,057 1.73 1,099 383 1,037 1.67 954 326 978 1.41 780 268 897 1.16
0.6 1,065 395 1,071 1.69 1,014 361 1,041 1.58 890 308 1,004 1.34 717 254 936 1.1
0.7 981 375 1,085 1.65 939 346 1,072 1.52 824 295 1,033 1.28 665 245 965 1.05
0.8 895 354 1,099 1.61 835 322 1,092 1.44 737 276 1,047 1.2 575 228 1,016 0.98
12
Dimensions
47
51
18 7/16
FLUE EXHAUST 16 A
1 3/8
5 1/2
16
7 15/16 B
2 3/4
SUCTION/LIQUID PRESSURE PORTS
BEHIND COMPRESSOR ACCESS PANE
RETURN
B
HEAT EXCHANGE ACCESS PANE
4 3/4
SUPPLY GAS ENTRANCE
SUPPLY
CONDENSATE DRAIN CONNECTION 3
3/4" NPT FEMALE
7 5/16
7 7/8
DIMENSIONS
DIMENSION SMALL
SMALL MEDIUM LARGE MEDIUM
(INCHES)
(INCHES)
A 27 32 40
B
A 16 16
27 18
32 40
POWER WIRE ENTRANCE B 16 16 16
CONTROL WIRE ENTRANCE
RETURN
11
22
22
11
Size 24 Small
Size 30 Small Note: See page 14 for opening locations.
Size 36 Medium
Size 42 Medium
Size 48 Large
Size 60 Large
13
Roof Curb Dimensions
42 5/8
15 x 22 1/2
3 Supply
49 1/2 x2 14 1/2
1/2 n
12 etur
R
1 5/8
14 1/2
1 3/8
Specifications:
1. Constructed of 18 gauge galvanized steel.
2. Features a 1" x 4" wood runner permanently attached to the top of the curb.
3. Shipped unassembled with all hardware and instructions necessary for
installation.
Accessories
Part Number Description
PGC101-103 Roof Curb
PGED101-2 Downflow Economizer, Small and Medium Chassis - See note 1
PGED103 Downflow Economizer, Large Chassis- See note 1
PGEH101-3 Horizontal Economizer, Small and Medium Chassis- See note 2
PGEH103 Horizontal Economizer, Large Chassis- See note 2
PGMDD101-2 Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis
PGMDD103 Manual 25% Fresh Air Damper Downflow Application, Large Chassis
PGMDH101 Manual 25% Fresh Air Damper Horizontal Application, Small Chassis
PGMDH102 Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis
PGMDH103 Manual 25% Fresh Air Damper Horizontal Application, Large Chassis
PGMDMD1012 Motorized 25% Fresh Air Damper Downflow Application, Small and Medium Chassis
PGMDMD103 Motorized 25% Fresh Air Downflow Application, Large Chassis
PGMDMH101 Motorized 25% Fresh Air Damper Horizontal Application, Small Chassis
PGMDMH102 Motorized 25% Fresh Air Damper Horizontal Application, Small and Medium Chassis
PGMDMH103 Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis
SQRPG101-2 Square to Round Adapter with 16" Round Downflow Application, Small and Medium Chassis
SQRPG103 Square to Round Adapter with 18" Round Downflow Application, Large Chassis
PGFR101-2 Internal Filter Rack All Chassis- not available with downflow economizer
14
RE 10.3 EER Self-Contained Packaged Electric
Air Conditioner
7 1/2 – 10 Ton
Self-contained packaged air conditioner features
combination electric heat/electric cooling. This unit is for
over/under or downflow applications.
Standard Features
Dual high-efficiency scroll compressors with internal
motor protection for 2-stage cooling
Compressor grommets for vibration isolation
Two independent condenser coils for 2-stage
operation
Enhanced copper tube, aluminum fin coils
Expansion valve evaporator coil
Galvanized steel, powder-coated drain pan with ¾"
NPT condensate connection
Time delay for compressors sequence
Fully charged R-22 systems
High- and low-pressure controls on all systems Cooling Capacities: 86,000 to 116,000 BTUH
Mild ambient switch
Totally enclosed, permanently lubricated outdoor fan
motors Accessories
Vertical discharge with removable grilles provide easy Economizers (horizontal and vertical)
access to fans and motors Room thermostat
Belt-driven, variable-pitch sheave permits multi-speed Roof curb
adjustment Manual fresh air damper
Centrifugal fan for quiet and efficient operation Motorized fresh air damper
Control box and compressors easily accessible from Horizontal duct kit
side access panels Panel louver kit
Factory wiring conveniently arranged to install
accessories
Filters are provided with unit (2" disposable )
Cabinet Construction
Heavy-gauge, zinc-coated steel cabinet with weather-
resistant powder-paint finish
Fully insulated with blankets of insulation
Base rails with fork slots for convenience of handling
and added rigidity
When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
Heat Kit Accessory
Control circuitry arranged to readily permit staging
Rust-resistant nickel chromium heating elements
Primary and secondary limit protection
Electric heat capacities: 20 kW to 40 kW (field-
installed accessory)
Model Nomenclature
RE 090 A C Y P Y
15
Data and Specifications
(1) Sensible capacity is gross, with no deduction for indoor motor heat
(2) BTU/Watt @ 80/67°F inside; 95°F outside air
(3) IPLV = Integrated Part Load Valve
(4) HACR breakers may be used in place of fuses up to 60 amps
16
Dimensional Data
All dimensions in inches; no scale
74 9/16
Vertical Discharge
(Factory Configuration) 74 9/16
See curb details for
connection of ductwork to curb.
17 9/32 Ductwork is not intended to be connected
40
17 9/32
5 7/8
18
4
18
28 11/16
Horizontal Discharge
(With Field Installed
Accessory)
3/4
*
17 9/32
7/8
40
MODEL A B C
HEIGHT SUPPLY RETURN
17 9/32
AIR AIR 1 9/32
090 36 12 1/2 17 9/16
102Unit Size A B C
Height Supply Air Return Air
120, 150 52 20 1/4 25 13/16
180 090 36 12-1/2 17-6/16
3 25/32
120 Accessory.
*Field Installed 52 20-1/4 25-13/16
17
Dimensional Data - Electrical Connections
5 5/8
A
1. Main power entrance location
16 27/32 2. Control wiring entrance location
9 3/32 3. Optional field installed internal disconnect switch
2 29/32
6 23/32 4. Knockout not used on electric heat units
Size A B
090 6-1/8 7-7/8
120 22-1/8 23-7/8
18
Fan Performance Data
Size 090 4 2 0 0 1 0 4 0 C F M 0 T u rn
C F M 1 T u rn
3 8 0 0 9 9 0 C F M 2 T u rn
C F M 3 T u rn
C F M 4 T u rn
3 4 0 0 9 4 0
R P M
C F M
R P M 0 T u rn
R P M 1 T u rn
3 0 0 0 8 9 0 R P M 2 T u rn
R P M 3 T u rn
R P M 4 T u rn
2 6 0 0 8 4 0
0 .3 0 .4 0 .5 0 .6 0 .7 0 .8
S ta tic , in . W .C .
Size 120 5 6 0 0 1 1 7 0
5 2 0 0 C F M 0 T u rn
1 1 2 0
C F M 1 T u rn
4 8 0 0 C F M 2 T u rn
1 0 7 0 C F M 3 T u rn
4 4 0 0 C F M 4 T u rn
R P M
1 0 2 0 C F M 5 T u rn
C F M
4 0 0 0 R P M 0 T u rn
9 7 0 R P M 1 T u rn
3 6 0 0 R P M 2 T u rn
3 2 0 0 9 2 0 R P M 3 T u rn
R P M 4 T u rn
2 8 0 0 8 7 0 R P M 5 T u rn
0 .3 0 .4 0 .5 0 .6 0 .7 0 .8 0 .9 1 .0
S ta tic , in . W .C .
19
Component Pressure Drops
NOTES:
1. Capacities are gross and are based on 230, 460 operation. 208-volt operation must be derated by 0.98. Gross capacities do not include evaporator motor heat
2. KW is for entire unit.
3. See table for capacity correction factors at other than nominal CFM.
20
Cooling Capacity Data - continued
RE 120 @ 4,000 CFM
EVAP. 75°F DB 80°F DB 85°F DB 90 °F DB
AMB. °F
EAT KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS
61 WB 10.2 115.9 99.7 10.2 118.6 117.2 10.3 125.3 125.3 10.3 132.0 132.0
64 WB 10.3 122.6 87.6 10.3 122.6 107.8 10.3 125.3 125.3 10.3 132.0 132.0
85 67 WB 10.3 130.7 75.4 10.3 130.7 95.6 10.3 130.7 114.5 10.5 132.0 132.0
70 WB 10.6 138.8 63.3 10.6 138.8 83.5 10.6 138.8 102.4 10.6 138.8 122.6
73 WB 10.6 146.9 51.2 10.6 146.9 71.4 10.6 146.9 90.3 10.7 146.9 110.5
61 WB 10.6 113.2 98.3 10.7 115.9 115.9 10.8 122.6 122.6 10.8 130.7 130.7
64 WB 10.8 119.9 86.2 10.8 121.3 106.4 10.8 122.6 122.6 10.8 130.7 130.7
90 67 WB 10.9 128.0 74.1 10.9 128.0 94.3 10.9 128.0 114.5 10.9 130.7 130.7
70 WB 10.9 134.7 62.0 10.9 134.7 82.2 10.9 136.1 102.4 11.0 136.1 121.2
73 WB 11.0 142.8 49.8 11.0 142.8 70.1 11.0 145.5 88.9 11.3 142.8 109.1
61 WB 11.0 111.8 98.3 11.1 114.5 114.5 11.1 121.3 121.2 11.3 129.3 129.3
64 WB 11.1 118.6 86.2 11.1 118.6 105.1 11.1 121.3 121.2 11.3 129.3 129.3
95 67 WB 11.3 125.3 74.1 11.3 125.3 94.3 11.3 125.3 113.2 11.4 129.3 129.3
70 WB 11.3 133.4 62.0 11.4 133.4 80.8 11.4 133.4 101.0 11.4 133.4 121.2
73 WB 11.5 140.1 48.5 11.5 140.1 68.7 11.5 140.1 88.9 11.6 140.1 109.1
61 WB 11.5 109.1 97.0 11.6 111.8 111.8 11.6 119.9 119.9 11.7 126.6 126.6
64 WB 11.6 115.9 84.9 11.6 115.9 105.1 11.6 119.9 119.9 11.7 126.6 126.6
100 67 WB 11.7 122.6 72.7 11.7 122.6 93.0 11.7 122.6 111.8 11.7 126.6 126.6
70 WB 11.8 130.7 60.6 11.8 130.7 80.8 11.8 130.7 99.7 11.8 130.7 118.5
73 WB 12.0 137.4 48.5 12.2 137.4 67.4 12.2 137.4 87.6 12.2 137.4 107.8
61 WB 12.0 106.4 95.6 12.0 110.5 110.5 12.2 117.2 117.2 12.3 124.0 123.9
64 WB 12.0 113.2 83.5 12.0 113.2 103.7 12.2 117.2 117.2 12.3 124.0 123.9
105 67 WB 12.3 119.9 71.4 12.3 119.9 91.6 12.3 119.9 110.5 12.3 124.0 123.9
70 WB 12.3 126.6 59.3 12.3 126.6 79.5 12.4 128.0 98.3 12.4 128.0 118.5
73 WB 12.6 136.1 47.2 12.6 136.1 67.4 12.6 136.1 86.2 12.6 136.1 106.4
NOTES:
1. Capacities are gross and are based on 230, 460 operation. 208-volt operation must be derated by 0.98. Gross capacities do not include evaporator motor heat
2. KW is for entire unit.
3. See table for capacity correction factors at other than nominal CFM.
21
Cooling Capacity Correction Factors
CFM
-15% -10% -5% STD. +5% +10% +15%
TOTAL MBH 0.971 0.985 0.991 0 1.006 1.012 1.019
SENSIBLE MBH 0.925 0.952 0.974 0 1.024 1.048 1.070
KW 0.985 0.989 0.995 0 1.004 1.006 1.011
Electric Heat
Electric Heat Air Temperature Rise
HEATER MODEL HKCB20 HKCB30 HKCB40
NO. STAGES 2 2 2
OUTPUT (MBH) 67.9 101.6 101.6
2600 24.2 36.2 -
2800 22.5 33.6 -
3000 21.0 31.4 -
3200 19.7 29.4 39.3
3400 18.5 27.7 37.0
3600 17.5 26.2 34.9
3800 16.5 24.8 33.1
4000 15.7 23.5 31.4
4200 15.0 22.4 29.9
CFM
4400 14.3 21.4 28.6
4600 13.7 20.5 27.3
4800 13.1 19.6 26.2
5000 12.6 18.8 25.2
5200 12.1 18.1 24.2
5400 11.6 17.4 23.3
5600 11.2 16.8 22.5
5800 10.8 16.2 21.7
6000 10.5 15.7 21.0
NOTES:
1. Maximum air temperature rise of 40 degrees must not be exceeded.
2. See table for electric heater availability in various unit sizes.
3. Air temperature rise is for total heating capacity. Temperature rises at other conditions may be calculated by using the formula:
4. For altitudes over 2,000 feet, air temperature rise must be calculated using the formula:
5. Operation at less than nominal voltages must be derated by the following factors: 460 volt-0.92; 230 volt-0.92; 208 volt-0.75.
X - Heater Available
22
Application Details & Factory- Economizers (Downflow - PGED090-5A &
Supplied Accessories PGED120-5A, Horizontal Flow - PGEH090-5
& PGEH120-5)
Thermostat (CHT90-120) Fully modulating, enthalpy-controlled economizers
Two-stage cool and two-stage heat thermostat with shipped with major components pre-assembled. Plug
subbase, manual changeover, fan on or auto. assembly on equipment and economizer provides easy
Note: A variety of thermostat configurations can be used foolproof wiring.
on this equipment based on the application needs. For Supply air versions are for downflow applications.
example, our CHTS36-60 can be used if two-stage Barametric relief dampers are provided with bottom
cooling and single-stage heat is desired. Our CHT18-60 return. Relief must be field installed in the return duct with
can be used if single-stage cooling and heating is desired. back return.
A single-stage cooling and two-stage heating thermostat
can be used. Horizontal Duct Kit (PGHDK090-5A &
PGHDK120-5A)
Roof Curb (PGC-5)
The unit is shipped in the downflow (vertical) duct
Full perimeter curb for equipment in the down discharge
configuration. The horizontal duct kit must be installed in
application. Curb includes provisions for duct attachment
the field for horizontal duct configuration.
prior to setting unit. Curb is shipped knocked down with all
necessary hardware and gasket material.
Manual and Motorized Fresh Air Dampers Panel Louver Kit (PLK090-120 & PLK120-
(PGMD-5 & PGMDM-5) 180)
Manual damper is fixed position type for 0 to 25% fresh Louvered panels for condenser coil protection.
air. Motorized damper is a field adjustable mechanical Heat Kit Accessory
damper for 0 to 25% fresh air. Damper automatically
closes when blower stops. Slide in heat kit from 20 to 40 kW. Heat kits 20, 30 and 40
kW can be used in 7½ to 10 ton models.
23
RG 10.3 EER Self-Contained Packaged Gas/Electric
7 1/2 – 10 Ton
Combination gas heat and electric cooling for over/under
or downflow applications.
Standard Features
Dual, high-efficiency scroll compressors with internal
motor protection (2-stage cooling)
Compressor grommets for vibration isolation
Time delay for compressor sequence
Fully charged R-22 systems
High- and low-pressure controls on all systems
Mild ambient switch
Two independent condenser coils for 2-stage
operation Cooling Capacities: 86,000 to 116,000 BTUH
Totally enclosed, permanently lubricated outdoor fan
motors Heating Capacities: 193,000 to 225,000 BTUH
Vertical discharge with removable grilles provide easy
access to fans and motors
Enhanced copper tube, aluminum fin coils Accessories
Expansion valve evaporator coil Room thermostat
Galvanized steel, powder-coated drain pan with ¾" Roof curb
NPT condensate connection Economizers (horizontal and vertical)
Belt-driven, variable-pitch sheave permits multi-speed Manual fresh air damper
adjustment Motorized fresh air damper
Horizontal Duct Kit
Centrifugal fan for quiet and efficient operation
L.P. Kit
Filters provided with unit (2" disposable) Panel Louver Kit
Control box and compressors are easily accessible
from side-access panels
Factory wiring conveniently arranged for installation
of accessories
2-stage heating
Combination redundant gas valve and regulator
Heavy-gauge aluminized tubular steel heat
exchangers
Power-assisted combustion
Integrated DSI Ignition Control
Cabinet Construction
Heavy-gauge, zinc-coated steel cabinet with weather-
resistant powder-paint finish
Fully insulated with blankets of insulation
Base rails with fork slots for convenience of handling
and added rigidity
When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
Model Nomenclature
RG 090 A C F P Y
24
Data and Specifications
RG090ACFPY RG090ACFQY RG120ACGPY RG120ACGQY
Total Cooling-BTUH 86,000 86,000 116,000 116,000
Sensible Cooling-BTUH (1) 63,600 63,600 85,000 85,000
EERa (2) 10.3 10.3 10.3 10.3
IPLV (3) 10.7 10.7 10.7 10.7
Max. Heating Input 193,000 193,000 225,000 225,000
Min. Heating Input (4) 133,000 133,000 153,000 153,000
Output Capacity 154,400 154,400 180,000 180,000
Steady State Eff. 80% 80% 80% 80%
Temp. Rise Range 35-65 35-65 30-60 30-60
Indoor Blower (Qty.) 2 2 2 2
Type Belt Belt Belt Belt
Size - D x W 12 x 12 12 x 12 12 x 15 12 x 15
Motor Horsepower 1½ 1½ 3 3
Indoor CFM Nominal 3,000 3,000 3,800 3,800
Evaporator Coil (Qty.) 1 1 1 1
Face Area (ft²) 11.2 11.2 14.0 14.0
Rows/FPI 3/16 3/16 3/16 3/16
Tube Diameter/Material 3/8”/Copper 3/8”/Copper 3/8”/Copper 3/8”/Copper
Filters Size & Qty. (3) 25 x 25 x 2 (3) 25 x 25 x 2 (3) 16 x 25 x 2 (3) 16 x 25 x 2
(3) 20 x 25 x 2 (3) 20 x 25 x 2
Outdoor Fan (Qty.) 2 2 2 2
Fan Diameter (In.) 24 24 24 24
Motor Horsepower ½ ½ ½ ½
Outdoor CFM Nominal 5,500 5,500 6,400 6,400
Condenser Coil (Qty.) 1 1 1 1
Face Area (Total ft²) 15.6 15.6 23.8 23.8
Rows/FPI 2/21 2/21 2/21 2/21
Tube Diameter/Material 3/8”/Copper 3/8”/Copper 3/8”/Copper 3/8”/Copper
Electrical
Ph 3 3 3 3
Volts 208/230 460 208/230 460
Compressor's RLA 12.5 5.9 17.4 6.8
Compressor's LRA 88.0 44.0 123.0 49.5
Indoor Blower FLA 4.2 2.1 8.4 4.2
Outdoor Blower's FLA 2.6 1.3 2.6 1.3
Min. Circuit Amp. 38.1 18.2 54.5 22.5
Max. Fuse Size (5) 60 30 70 35
Net Weight 1.080 1,080 1,380 1,380
Shipping Weight 1,100 1,100 1,400 1,400
(1) Sensible capacity is gross, with no deduction for indoor motor heat
(2) BTU/Watt @ 80/67°F inside; 95°F outside air
(3) IPLV is integrated part load valve
(4) Minimum Input is first stage input
(5) HACR breakers may be used in place of fuses up to 60 amps
25
Dimensional Data
All dimensions in inches; no scale
74 9/16
Vertical Discharge
(Factory Configuration) 74 9/16
See curb details for
connection of ductwork to curb.
17 9/32 Ductwork is not intended to be connected
40
17 9/32
5 7/8
18
4
18
28 11/16
Horizontal Discharge
(With Field Installed
Accessory)
3/4
*
17 9/32
7/8
40
MODEL A B C
HEIGHT SUPPLY RETURN
17 9/32
AIR AIR 1 9/32
090 36 12 1/2 17 9/16
102Unit Size A B C
26
Dimensional Data - Electrical Connections
5 5/8
A 1. Main power entrance location
16 27/32 2. Control wiring entrance location
2 29/32
9 3/32 3. Optional field-installed internal disconnect switch
6 23/32
4. Gas piping entrance location
27
Fan Performance Data
Size 090 1 0 9 0
3 8 0 0 C F M 0 T u rn
C F M 1 T u rn
1 0 4 0
C F M 2 T u rn
C F M 3 T u rn
3 4 0 0 9 9 0
R P M 0 T u rn
R P M
C F M
R P M 1 T u rn
9 4 0 R P M 2 T u rn
3 0 0 0 R P M 3 T u rn
8 9 0
2 6 0 0 8 4 0
0 .3 0 .4 0 .5 0 .6 0 .7 0 .8
S ta tic , in . W .C .
Size 120 5 2 0 0 1 2 2 0
1 1 7 0 C F M 0 T u rn
4 8 0 0 C F M 1 T u rn
1 1 2 0 C F M 2 T u rn
4 4 0 0 C F M 3 T u rn
1 0 7 0 C F M 4 T u rn
R P M
4 0 0 0
C F M
C F M 5 T u rn
1 0 2 0 R P M 0 T u rn
3 6 0 0 R P M 1 T u rn
9 7 0
R P M 2 T u rn
3 2 0 0 9 2 0 R P M 3 T u rn
R P M 4 T u rn
2 8 0 0 8 7 0 R P M 5 T u rn
0 .3 0 .4 0 .5 0 .6 0 .7 0 .8 0 .9 1 .0
S ta tic , in . W .C .
28
Component Pressure Drops
Gas Furnace Section Econo. Return
Unit Size CFM Wet Coil Med. Eff. Filters
195 225 Air Damper
NOTES:
1. Capacities are gross and are based on 230, 460 operation. 208-volt operation must be derated by 0.98. Gross capacities do not include evaporator motor heat
2. KW is for entire unit.
3. See table for capacity correction factors at other than nominal CFM.
29
RG 120 @ 4,000 CFM
EVAP. 75°F DB 80°F DB 85°F DB 90°F DB
AMB. °F
EAT KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS
61 WB 10.2 115.9 99.7 10.2 118.6 117.2 10.3 125.3 125.3 10.3 132.0 132.0
64 WB 10.3 122.6 87.6 10.3 122.6 107.8 10.3 125.3 125.3 10.3 132.0 132.0
85 67 WB 10.3 130.7 75.4 10.3 130.7 95.6 10.3 130.7 114.5 10.5 132.0 132.0
70 WB 10.6 138.8 63.3 10.6 138.8 83.5 10.6 138.8 102.4 10.6 138.8 122.6
73 WB 10.6 146.9 51.2 10.6 146.9 71.4 10.6 146.9 90.3 10.7 146.9 110.5
61 WB 10.6 113.2 98.3 10.7 115.9 115.9 10.8 122.6 122.6 10.8 130.7 130.7
64 WB 10.8 119.9 86.2 10.8 121.3 106.4 10.8 122.6 122.6 10.8 130.7 130.7
90 67 WB 10.9 128.0 74.1 10.9 128.0 94.3 10.9 128.0 114.5 10.9 130.7 130.7
70 WB 10.9 134.7 62.0 10.9 134.7 82.2 10.9 136.1 102.4 11.0 136.1 121.2
73 WB 11.0 142.8 49.8 11.0 142.8 70.1 11.0 145.5 88.9 11.3 142.8 109.1
61 WB 11.0 111.8 98.3 11.1 114.5 114.5 11.1 121.3 121.2 11.3 129.3 129.3
64 WB 11.1 118.6 86.2 11.1 118.6 105.1 11.1 121.3 121.2 11.3 129.3 129.3
95 67 WB 11.3 125.3 74.1 11.3 125.3 94.3 11.3 125.3 113.2 11.4 129.3 129.3
70 WB 11.3 133.4 62.0 11.4 133.4 80.8 11.4 133.4 101.0 11.4 133.4 121.2
73 WB 11.5 140.1 48.5 11.5 140.1 68.7 11.5 140.1 88.9 11.6 140.1 109.1
61 WB 11.5 109.1 97.0 11.6 111.8 111.8 11.6 119.9 119.9 11.7 126.6 126.6
64 WB 11.6 115.9 84.9 11.6 115.9 105.1 11.6 119.9 119.9 11.7 126.6 126.6
100 67 WB 11.7 122.6 72.7 11.7 122.6 93.0 11.7 122.6 111.8 11.7 126.6 126.6
70 WB 11.8 130.7 60.6 11.8 130.7 80.8 11.8 130.7 99.7 11.8 130.7 118.5
73 WB 12.0 137.4 48.5 12.2 137.4 67.4 12.2 137.4 87.6 12.2 137.4 107.8
61 WB 12.0 106.4 95.6 12.0 110.5 110.5 12.2 117.2 117.2 12.3 124.0 123.9
64 WB 12.0 113.2 83.5 12.0 113.2 103.7 12.2 117.2 117.2 12.3 124.0 123.9
105 67 WB 12.3 119.9 71.4 12.3 119.9 91.6 12.3 119.9 110.5 12.3 124.0 123.9
70 WB 12.3 126.6 59.3 12.3 126.6 79.5 12.4 128.0 98.3 12.4 128.0 118.5
73 WB 12.6 136.1 47.2 12.6 136.1 67.4 12.6 136.1 86.2 12.6 136.1 106.4
NOTES:
1. Capacities are gross and are based on 230, 460 operation. 208-volt operation must be derated by 0.98. Gross capacities do not include evaporator motor heat
2. KW is for entire unit.
3. See table for capacity correction factors at other than nominal CFM.
30
Gas Heat
Gas Furnace Air Temperature Rise
MODEL 195 225
NUMBER OF TUBES 6 7
VENTOR MOTOR HP 1/16 1/12
MBH INPUT 193 225
MBH OUTPUT 154.4 180.0
MAX. AIR TEMP. RISE 65 60
2600 55.0 —
2800 51.1 —
3000 47.7 55.6
3200 44.7 52.1
3400 42.1 49.1
CFM 3600 39.7 46.3
3800 — 43.9
4000 — 41.7
4200 — 39.7
4400 — 37.9
4600 — 36.3
NOTES:
1. See Gas Furnace Air Temperature Rise table for furnace availability in various unit sizes.
2. Capacities are approved for altitudes to 2,000’. At higher elevations, heating capacity must be reduced 4% (x0.96) for each 1,000’ above sea level.
3. Air temperature rise is for total heating capacity. Temperature rises at other conditions may be calculated by using the formula:
Temperature Rise = Output Capacity - BTUH
1.08 x ft.³/min. Airflow
4. For altitudes over 2,000 feet, air temperature rise must be calculated using the formula:
Temperature Rise = Output Capacity - BTUH
14.4 x ft.³/min. Airflow x Specific Weight of Air
5. Two-stage control is standard.
6. Output capacity based on nominal 1,000 BTU/Ft.³ natural gas or 2,500 Btu/Ft.³ propane.
X - Furnace Available
N/A - Furnace Not Available
31
Factory-Supplied Accessories Economizers (Downflow - PGED090-5A &
PGED120-5A, Horizontal Flow - PGEH090-5
Thermostat (CHT90-120) & PGEH120-5)
Two stage cool and two stage heat thermostat with
Fully modulating, enthalpy-controlled economizers
subbase, Manual changeover, Fan ON or AUTO. Note: A
shipped with major components pre-assembled. Plug
variety of thermostat configurations can be used on this
assembly on equipment and economizer provides easy
equipment based on the application needs. For example
foolproof wiring.
our CHTS36-60 can be used if two stage cooling and
single stage heat is desired. Our CHT18-60 can be used if Supply air versions are for downflow applications.
single stage cooling and heating is desired. A single stage Barametric relief dampers are provided with bottom
cooling and two stage heating thermostat can be used. return. Relief must be field installed in the return duct with
back return.
Roof Curb (PGC-5)
Horizontal Duct Kit (PGHDK090-5A &
Full perimeter curb for equipment in the down discharge
application. Curb includes provisions for duct attachment PGHDK120-5A)
prior to setting unit. Curb is shipped knocked down with all The unit is shipped in the down flow (vertical) duct
necessary hardware and gasket material. configuration. The horizontal duct kit must be installed in
the field for horizontal duct configuration.
Manual and Motorized Fresh Air Dampers
(PGMD-5 & PGMDM-5) Liquid Propane Kit (LPW-06)
Manual damper is fixed position type for 0 to 25% fresh Kit consists of an L.P. 2-stage gas valve and main gas
air. Motorized damper is a field adjustable mechanical orifices to convert appliance from natural gas to liquid
damper for 0 to 25% fresh air, damper automatically propane fuel.
closes when blower stops. Panel Louver Kit (PLK090-120 & PLK120-
180)
Louvered panels for condenser coil protection.
32
Catalog 1701
This document contains the most current product information as of this printing. For the most up-to-date product
information, please go to www.mcquay.com.