SEER − 13.00
2 to 5 Tons
Cooling Capacity − 23,000 to 55,500 Btuh
Input Gas Heating Capacity − 67,500 to 137,500 Btuh
H
G
B F
K
D I
J E
L
C
CONTENTS Applications
Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7 Designed for outdoor installations at ground level or
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8 rooftop for residential applications.
Dimensions − Accessories . . . . . . . . . . . . . . . . . . . . Page 9 Approvals
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5 Units are design certified by UL.
Expanded Cooling Ratings . . . . . . . . . . . . . . . Pages 10−11 Heating ratings are according to Department of Energy
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2−4 (DOE) test procedures and Federal Trade Commission
Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7 (FTC) labeling regulations and are certified by GAMA.
High Altitude Derate Information . . . . . . . . . . . . . . . Page 6 Low NOx X" models meet California Nitrogen Oxides
Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . Page 7 (NOx) standards.
Model Number Identification . . . . . . . . . . . . . . . . . . Page 1 Cooling system rated according to DOE test procedures.
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 6 Cooling system rated in accordance with ARI standard
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5 210/240.
Equipment Warranty Units are listed by UL for the U.S. and Canada.
Heat Exchanger − limited warranty for twenty years in Packaged unit and components within bonded for
residential applications and five years in non−residential grounding to meet safety standards required by UL.
applications. Each unit test operated at the factory before shipment
Compressor − limited warranty for five years in ensuring dependable operation at start−up.
residential installations and five years in non-residential
installations.
All other covered components − five years in
residential installations and one year in non-residential
installations.
Refer to Lennox Equipment Limited Warranty certificate
included with unit for specific details.
FIELD WIRING
THERMOSTAT DISCONNECT
(Optional) SWITCH
(Not Furnished
By Lennox)
A− Four Wire Low Voltage (Electro-mechanical)
A B − Five Wire Low Voltage (Electronic)
B− Two Wire Power (See Electrical Data Table)
− Field Wiring Not Furnished −
NOTE − All wiring must conform to NEC or CEC and local electrical codes.
SINGLE
PACKAGE
UNIT
External Static Air Volume at Various Blower Speeds External Static Air Volume at Various Blower Speeds
Pressure High Medium Low Pressure High Medium Low
in. w.g. Pa cfm L/s cfm L/s cfm L/s in. w.g. Pa cfm L/s cfm L/s cfm L/s
.20 50 1470 695 1070 505 880 415 .20 50 1510 715 1060 500 870 410
.30 75 1420 670 1060 500 870 410 .30 75 1460 690 1050 495 860 405
.40 100 1360 640 1020 480 850 400 .40 100 1400 660 1030 485 840 395
.50 125 1290 610 1000 470 820 385 .50 125 1330 630 990 465 820 385
.60 150 1220 575 950 450 790 375 .60 150 1250 590 950 450 790 375
.70 175 1140 540 900 425 740 350 .70 175 1180 555 900 425 750 355
.80 200 1050 495 830 390 690 325 .80 200 1100 520 850 400 680 320
NOTE − All air data is measured external to unit without air filters. NOTE − All air data is measured external to unit without air filters.
1 For down-flow air volume, add 0.05 in. w.g. (12 Pa) to duct static. 1 For down-flow air volume, add 0.05 in. w.g. (12 Pa) to duct static.
1 3 (76)
48 (1219)
HORIZONTAL HORIZONTAL
SUPPLY AIR RETURN AIR
OPENING OPENING
A
E E H
D D
2−3/4 2−3/4
(70) (70)
FRONT VIEW K J
BACK VIEW
4−1/4 (108)
GAS PIPING INLET
3−1/4 (83)
FLUE
OUTLET
ELECTRICAL INLET
F G H J K L
Model No.
No
in. mm in. mm in. mm in. mm in. mm in. mm
13GCSA−24
13GCSA−30 20 508 8−1/2 216 3 76 20−1/4 514 4−1/2 114 19 483
13GCSA−36
13GCSA−42
13GCSA−48 22 559 9−1/4 241 3−1/4 83 22−1/4 572 4 102 16−1/4 413
13GCSA−60
2 (51) 2 (51)
2 (51) 2 (51)
20 (508) 20 (508)
34 (864) Return Supply
24, 30, 36 Air Air
Opening 20 (508) Opening 20 (508)
43−1/2 (1105)
42, 48, 60
2 (51) 2 (51)
TOP VIEW
8 (203)
or
14 (356)
SIDE VIEW
2 TON 13GCSA−24
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Ai
Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
T
Temperatt Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ure Capacity Motor Dry Bulb CapacityMotor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
600 285 22.0 6.4 1.29 0.72 0.85 0.98 20.9 6.1 1.45 0.73 0.86 0.99 19.7 5.8 1.65 0.76 0.90 1.00 18.5 5.4 1.87 0.78 0.92 1.00
63_F 800 380 22.9 6.7 1.30 0.79 0.93 1.00 21.9 6.4 1.47 0.80 0.95 1.00 20.6 6.0 1.67 0.83 0.98 1.00 19.3 5.6 1.89 0.85 1.00 1.00
(17_C)
1000 470 23.7 6.9 1.32 0.85 1.00 1.00 22.5 6.6 1.48 0.86 1.00 1.00 21.3 6.2 1.68 0.90 1.00 1.00 19.9 5.8 1.91 0.92 1.00 1.00
600 285 23.4 6.9 1.32 0.57 0.69 0.81 22.3 6.5 1.48 0.57 0.70 0.82 21.0 6.2 1.68 0.60 0.73 0.86 19.7 5.8 1.91 0.61 0.75 0.88
67_F 800 380 24.2 7.1 1.32 0.61 0.76 0.90 23.0 6.7 1.48 0.62 0.77 0.92 21.7 6.4 1.68 0.64 0.80 0.95 20.3 5.9 1.91 0.66 0.82 0.98
(19_C)
1000 470 24.6 7.2 1.32 0.65 0.83 0.98 23.5 6.9 1.48 0.66 0.84 0.99 22.1 6.5 1.68 0.69 0.87 1.00 20.7 6.1 1.91 0.70 0.90 1.00
600 285 24.9 7.3 1.33 0.43 0.54 0.66 23.7 6.9 1.49 0.44 0.55 0.67 22.3 6.5 1.70 0.46 0.57 0.69 20.9 6.1 1.93 0.47 0.59 0.71
71_F 800 380 25.6 7.5 1.33 0.44 0.58 0.73 24.4 7.1 1.49 0.45 0.59 0.74 23.0 6.7 1.70 0.47 0.62 0.77 21.5 6.3 1.93 0.48 0.63 0.79
(22_C)
1000 470 26.1 7.6 1.34 0.47 0.64 0.81 24.8 7.3 1.51 0.47 0.65 0.82 23.4 6.9 1.72 0.49 0.67 0.85 21.9 6.4 1.95 0.50 0.69 0.87
3 TON 13GCSA−36
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Ai
Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
T
Temperatt Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ure Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
1000 470 35.7 10.5 2.13 0.71 0.84 0.97 34.0 10.0 2.43 0.73 0.87 1.00 32.1 9.4 2.76 0.75 0.89 1.00 30.0 8.8 3.13 0.78 0.92 1.00
63_F 1200 565 36.9 10.8 2.13 0.76 0.90 1.00 35.2 10.3 2.43 0.78 0.92 1.00 33.2 9.7 2.76 0.80 0.95 1.00 31.0 9.1 3.13 0.83 0.98 1.00
(17_C)
1400 660 38.1 11.2 2.13 0.81 0.94 1.00 36.3 10.6 2.43 0.83 0.97 1.00 34.2 10.0 2.76 0.86 0.99 1.00 32.0 9.4 3.13 0.89 1.00 1.00
1000 470 37.7 11.0 2.16 0.56 0.68 0.81 35.9 10.5 2.45 0.57 0.70 0.83 33.9 9.9 2.78 0.58 0.72 0.85 31.6 9.3 3.16 0.61 0.74 0.88
67_F 1200 565 38.9 11.4 2.16 0.58 0.73 0.87 37.0 10.8 2.45 0.60 0.75 0.89 34.9 10.2 2.78 0.62 0.77 0.92 32.6 9.6 3.16 0.64 0.80 0.95
(19_C)
1400 660 39.6 11.6 2.16 0.62 0.78 0.91 37.7 11.1 2.45 0.64 0.80 0.94 35.6 10.4 2.78 0.65 0.82 0.96 33.3 9.8 3.16 0.68 0.85 1.00
1000 470 40.4 11.8 2.16 0.42 0.53 0.65 38.5 11.3 2.45 0.43 0.55 0.67 36.3 10.6 2.78 0.44 0.56 0.68 33.9 9.9 3.16 0.46 0.58 0.71
71_F 1200 565 41.2 12.1 2.16 0.43 0.56 0.70 39.2 11.5 2.45 0.44 0.58 0.72 37.0 10.8 2.78 0.45 0.59 0.74 34.6 10.1 3.16 0.47 0.62 0.77
(22_C)
1400 660 42.0 12.3 2.18 0.44 0.60 0.76 40.0 11.7 2.47 0.45 0.62 0.78 37.7 11.0 2.81 0.46 0.63 0.80 35.2 10.3 3.20 0.48 0.66 0.83
4 TON 13GCSA−48
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Ai
Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
T
Temperatt Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ure Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
1400 660 45.9 13.5 2.70 0.74 0.88 1.00 43.7 12.8 3.07 0.75 0.89 1.00 41.6 12.2 3.49 0.77 0.92 1.00 39.3 11.5 3.96 0.79 0.94 1.00
63_F 1600 755 46.9 13.7 2.70 0.76 0.91 1.00 44.7 13.1 3.07 0.77 0.92 1.00 42.5 12.5 3.49 0.79 0.95 1.00 40.1 11.8 3.96 0.82 0.97 1.00
(17_C)
1800 850 47.4 13.9 2.70 0.79 0.94 1.00 45.1 13.2 3.07 0.80 0.95 1.00 43.0 12.6 3.49 0.83 0.98 1.00 40.5 11.9 3.96 0.85 1.00 1.00
1400 660 48.9 14.3 2.73 0.58 0.71 0.85 46.5 13.6 3.10 0.59 0.72 0.87 44.3 13.0 3.52 0.60 0.74 0.89 41.8 12.3 4.00 0.62 0.76 0.91
67_F 1600 755 49.4 14.5 2.73 0.59 0.74 0.88 47.0 13.8 3.10 0.60 0.75 0.89 44.8 13.1 3.52 0.62 0.77 0.92 42.2 12.4 4.00 0.63 0.79 0.94
(19_C)
1800 850 49.8 14.6 2.73 0.61 0.77 0.92 47.5 13.9 3.10 0.62 0.78 0.94 45.2 13.2 3.52 0.63 0.80 0.96 42.7 12.5 4.00 0.65 0.82 0.99
1400 660 51.8 15.2 2.76 0.44 0.56 0.68 49.4 14.5 3.13 0.44 0.57 0.69 47.0 13.8 3.56 0.45 0.58 0.71 44.3 13.0 4.04 0.46 0.60 0.73
71_F 1600 755 52.3 15.3 2.76 0.44 0.58 0.71 49.8 14.6 3.13 0.45 0.59 0.72 47.4 13.9 3.56 0.46 0.60 0.74 44.8 13.1 4.04 0.47 0.62 0.76
(22_C)
1800 850 52.8 15.5 2.76 0.45 0.59 0.74 50.3 14.7 3.13 0.46 0.60 0.75 47.9 14.0 3.56 0.47 0.62 0.77 45.2 13.2 4.04 0.48 0.64 0.79
5 TON 13GCSA−60
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Ai
Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
T
Temperatt Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ure Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
1600 755 54.2 15.9 3.25 0.72 0.86 0.99 51.6 15.1 3.69 0.73 0.87 1.00 49.2 14.4 4.20 0.75 0.89 1.00 46.4 13.6 4.77 0.77 0.92 1.00
63_F 1800 850 55.4 16.2 3.25 0.74 0.89 1.00 52.7 15.5 3.69 0.75 0.90 1.00 50.2 14.7 4.20 0.77 0.92 1.00 47.4 13.9 4.77 0.79 0.95 1.00
(17_C)
2000 945 55.9 16.4 3.25 0.77 0.91 1.00 53.3 15.6 3.69 0.78 0.92 1.00 50.7 14.9 4.20 0.80 0.95 1.00 47.9 14.0 4.77 0.83 0.97 1.00
1600 755 57.7 16.9 3.28 0.56 0.69 0.83 54.9 16.1 3.73 0.57 0.70 0.84 52.3 15.3 4.24 0.59 0.72 0.87 49.4 14.5 4.82 0.60 0.74 0.89
67_F 1800 850 58.3 17.1 3.28 0.58 0.72 0.86 55.5 16.3 3.73 0.58 0.73 0.87 52.9 15.5 4.24 0.60 0.75 0.89 49.9 14.6 4.82 0.62 0.77 0.92
(19_C)
2000 945 58.9 17.2 3.28 0.59 0.75 0.90 56.1 16.4 3.73 0.60 0.76 0.91 53.4 15.6 4.24 0.62 0.78 0.94 50.4 14.8 4.82 0.63 0.80 0.96
1600 755 61.2 17.9 3.32 0.42 0.54 0.67 58.3 17.1 3.77 0.43 0.55 0.68 55.5 16.3 4.28 0.44 0.57 0.69 52.4 15.3 4.86 0.45 0.58 0.71
71_F 1800 850 61.8 18.1 3.32 0.43 0.56 0.69 58.8 17.2 3.77 0.44 0.57 0.70 56.0 16.4 4.28 0.45 0.58 0.72 52.9 15.5 4.86 0.46 0.60 0.74
(22_C)
2000 945 62.4 18.3 3.32 0.44 0.58 0.72 59.4 17.4 3.77 0.45 0.59 0.73 56.6 16.6 4.28 0.46 0.60 0.75 53.4 15.6 4.86 0.47 0.62 0.77
NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2006 Lennox Industries Inc.