You are on page 1of 2

ISO performance based on natural gas

GE Energy
SAC SAC DLE STIG
(w/H20) (w/stm) (w/stm)
Power Output (MW) 102.6 104.5 98.7 112.2
Heat Rate LHV (Btu/KWH) 7813 7167 7509 6845
Exhaust Flow (lbs/sec) 469.8 470.1 453 490.5
Exhaust Temperature (ºF) 764 761 787 737
Emissions (ppmvd) 25 25 25 25
Power Turbine Speed (rpm) 3,600 3,600 3,600 3,600
No. of Compressor Stages 20 20 20 20
No. of Turbine Stages
Intermediate Pressure (IPT) 2 2 2 2
High Pressure (HPT) 2 2 2 2
LMS100 Gas Turbine (60Hz) Power (PT) 5 5 5 5

TECHNOLOGY SERVICE
The LMS100 is an intercooled gas turbine system, developed from GE GE Energy is the world’s largest aeroderivative service
frame and aeroderivative gas turbine technologies, with simple cycle provider, with a global network of field service offices and
thermal efficiencies ranging from 44 to 50%. fully equipped Service Centers. A wide range of products
• Peaking, Mid-range and Baseload Power Capabilities of and services are offered for the LMS100 utility and
98 to 112 MW ISO. industrial operators including:
• No Maintenance Penalty for Frequent Stops and Starts
• Modular Design for Ease of Maintenance and High Availability • Customer Support 24/7/365
• Fast 10-minute Start-up • Global Field Services Capability
• High Part-power Efficiency • Level IV Service Centers in Houston, Texas
and Rheden, the Netherlands
EXPERIENCE • Comprehensive Spare Parts Support
The LMS100 is a new gas turbine based on a combination of proven • Critical Repairs Available Globally
technologies, derived from the CF6-80E and CF6-80C2 aircraft engines, • Spare or Lease Engine Module Options
the predominant engines for the Boeing™ 747 and 767 wide-body • Rotable Module Exchange Programs
aircraft, and from the frame MS6001FA gas turbine. > Gas Turbine Supercore
• GE CF6-80 Engines Have More Than 100 Million Operating > High Pressure Turbine
Hours in Airline Service > Combustor
• GE F Technology Units Have More Than Eight Million Operating > Power Turbine
Hours in Power Generation Service • CM&U – Upgrade Urograms
• End-users: Utilities, Municipalities, Independent • Remote Diagnostic Services
Power Producers • Customer Training Courses
• Configurations: Simple Cycle, Cogeneration • Wide Variety of Contractual
and Combined Cycle. Service Agreements

INNOVATION This comprehensive product offering, combined with our


GE Energy and GE Transportation collaborated, along with three commitment to reduce Service Center and outage turn
companies outside of GE, to develop the first modern intercooled times, may result in substantial life cycle cost savings
gas turbine cycle. for the plant owner/operator.
• 100 MW Blocks of Power
• Cycling Capability
• Sustained Power Capability on Hot Days
• Fuel Flexibility
• Coal Feedwater Heating
• Two Waste Heat Sources (Exhaust & Intercooler)

www.gepower.com
LMS100 60Hz Output and Heat Rate
110 8,300
100 8,200

HEAT RATE (Btu /KWH)


90 8,100
OUTPUT (MW)

80 8,000
70 7,900
60 7,800
50 7,700
40 7,600
0 20 40 60 80 100 120 Dimensions Refer to Package Only
0 ft. elev., 60% Rel. Humidity, 4/6 in. inlet/exhaust losses 0
performance at the generator terminals, INLET TEMP ( F)
NOx = 25 ppm, LHV = 19,000 BTU/lb LENGTH 60’ x WIDTH 15’ x HEIGHT 15’

STANDARD 60 H Z LMS100 GENERATOR PACKAGE OPTIONAL EQUIPMENT AND SERVICES

Gas Turbine • Dry Secondary Cooling System for


• 20 Stage Axial Compressor Intercooler and Lube Oil System
> 6 Low Pressure Stages & 14 High Pressure Stages • Generator Options
> Off-engine air to water intercooler > TEWAC
> Horizontal Split Casing > Voltages: 12.47
> 42:1 Compression Ratio > Enclosure
> 460 lb/s (209 kg/s) Nominal Inlet Mass Flow > Fault Protection
• Annular Combustor > Synchronous Condensor
> 30 Gas Fuel Nozzles, Water or Steam Injection for NOx Control • Fuel System
> 15 Gas Fuel Nozzles, Dry Low Emission Control > Liquid
• 2-Stage High Pressure (HPT) & Intermediate Pressure Turbine (IPT) Water Injection
• 5-Stage Aerodynamically Coupled Power Turbine (PT) > Dual
Generator Water Injection
• 13.8 kV, 0.85 PF Continuous Duty > Gas
• 2 pole, 3 Phase, Brushless Exciter Water or Steam Injection or DLE
• WPII Weather Protected • Control System
• Voltage Regulator/Neutral Side Protection CT’s > Black Start
• NEMA Class F Insulation & B Temperature Rise > Continuous Emissions Monitoring
• Integrated Protection Relay Panel > Remote Display
Package > Motor Control House
• Local Control System In Weather Proof Room • Lube Oil System
• 24V and 125V DC Batteries > Air to Oil Coolers
• 85 dBA Near Field Design > First Fill Lubricants
• Pulse Clean Inlet Air Filters • Winterization
• Electro-Hydraulic Start/Shutdown System • Remote Monitoring and Diagnostics
• Class 1 Div 2 Group D Class Electrical System • 80 dBA Capability
• Mark VIe TMR Digital Control System with • Inlet Conditioning
a Human Machine Interface (HMI) > Evaporative Cooling
• Lube Oil System with Duplex Shell and Tube Coolers > Chilling
• Turbine Factory Tested, Full Speed No Load > Heating
• On/Off Water Wash
• 1-Year Parts/Service Warranty and
Remote Monitoring and Diagnostics
• Package Familiarization Training
• Electronically Transmitted Drawings
• Start-up Technical Assistance

www.gepower.com