RELIEF VALVE SUMMARY

Mar 12, 2009

CASE : FCC-2
Diameter (in) Pressurepsia % Built Areain²
Name Type Inlet Outlet Set Inlet Outlet Up Pres Available Required Sizing Method
RV-5E2 Balanced Bellow 6.00 8.01 174.00 177.76 47.57 20.64 11.050 18.635 Api 2Ph
RV-5E1 Balanced Bellow 6.00 8.01 159.30 177.76 45.75 21.47 11.050 18.635 Api 2Ph
RV-1E1 Balanced Bellow 8.01 10.00 48.84 48.85 29.00 41.88 26.000 24.712 Api 2Ph
RV-1E2 Balanced Bellow 8.01 10.00 48.84 48.85 29.00 41.88 26.000 24.712 Api 2Ph
RV-1E3 Balanced Bellow 8.01 10.00 48.84 48.85 26.84 35.57 26.000 24.699 Api 2Ph
RV-1E4 Balanced Bellow 8.01 10.00 48.84 48.85 27.23 36.70 26.000 24.699 Api 2Ph
RV-1E5 Balanced Bellow 8.01 10.00 48.84 48.85 29.70 43.95 26.000 24.730 Api 2Ph
RV-1E6 Balanced Bellow 8.01 10.00 48.84 48.85 29.70 43.95 26.000 24.730 Api 2Ph
RV-3E1 Balanced Bellow 4.00 6.00 188.22 188.31 35.22 11.83 6.380 6.401 Api 2Ph
RV-6E Balanced Bellow 4.00 6.00 284.90 286.53 36.36 8.02 6.380 4.290 Api 2Ph

Remarks:
Required Area = -1 implies that back-pressure to the RV is higher than Inlet pressure

File Name: CATALITICA_0.flr File Date: Mar 12, 2009 Converged Solution: True