Scanning
d) 75 mm square
Complete loss of back wall echo and reflection from discontinuity detected along the grid line,
entire surface area of the square and adjacent squares to be scanned.
Grid pattern
Boundary of the indication
Probe movement till the height of back wall echo and discontinuity are equal.
Recording level:
all indications with amplitude equal to or greater than 50% of the initial back reflection and
accompanied by a 50 % loss of back reflection shall be recorded.
Acceptance- Lamination
Total loss of back wall reflection which cannot be contained within a circle, the diameter of
which is 75 mm or ½ T whichever is grater is not acceptable-
Marking:
Post cleaning:
The surface shall be cleaned off from the couplant to the extent possible.
ANGLE-BEAM UT OF STEEL PLATES
Angle- 45°
Calibration Notch
Notch 3% of thickness
25 mm length
50 mm from edge
Reference echo
b) Without altering gain, notch in the opposite side picked up and amplitude to be noted
Scanning
Acceptance
Marking
Post cleaning
The surface shall be cleaned off from the couplant to the extent possible.
*************************