TYPE (LSIG) F121E F122E F123E F131E F132E F133E F141E F142E F143E F151E F152E F153E
Rated Current - In A 630 ... 2000 2500, 3200 4000 5000, 6300
Number of Poles 3/4 3/4 3/4 3/4
Rated Insulation Voltage - Ui (a.c.) 50-60Hz V 1000 1000 1000 1000
Rated Impulse Withstand Voltage - Uimp V 8 8 8 8
Test Voltage (1 min) (a.c.) 50-60Hz V 3000 3000 3000 3000
Rated Current Adjustment Field In (0,4-1)In (0,4-1)In (0,4-1)In (0,4-1)In
50-60Hz 220/240V kA 70 80 100 70 80 100 70 80 100 70 80 120
Rated Ultimate Short 50-60Hz 380/415V kA 70 80 100 70 80 100 70 80 100 70 80 120
Circuit Breaking 50-60Hz 440V kA 65 75 90 65 75 90 65 75 90 65 75 90
Capacity - Icu
50-60Hz 500V kA 55 65 80 55 65 80 55 65 80 55 65 80
50-60Hz 690V kA 45 50 65 45 50 65 45 50 65 45 50 65
Rated Short-Circuit Breaking Capacities-Ics kA 35 50 65 35 65 80 35 65 80 35 65 100
Rated Short Time Withstand Capacities-Icw-1s 380/415V 35 50 65 35 65 80 50 65 80 50 65 100
Category (EN 60947-2 / IEC 60947-2) A/B A/B A/B A
Opening Type Electronic Electronic Electronic Electronic
Assembly Method Fixed / Drawout Fixed / Drawout Fixed / Drawout Drawout
Long Time Delay Current (IL) Ir1 (0,4-1)In (0,4-1)In (0,4-1)In (0,4-1)In
Long Time Delay Interval tl s 15-500 15-500 15-500 15-500
Short Time Delay Current (IS) Ir2 (0,4-15)In (0,4-15)In (0,4-15)In (0,4-15)In
Short Time Delay Interval ts s 0,1-0,5 0,1-0,5 0,1-0,5 0,1-0,5
Instantaneous Breaking Current (II) Ir3 In-50kA In-50kA In-50kA In-50kA
Ground Fault Current (IG) Ir4 (0,2-0,8)In (0,2-0,8)In (0,2-0,8)In (0,2-0,8)In
Undervoltage release is used for tripping air type circuit breakerin case
of undervoltage conditions or phase disconnection. There are two types
Undervoltage Coil of undervoltage releasers as instant tripping and delayed tripping types.
Delayed type undervoltage release has 1 sec. 2 sec. and 5 sec. delayed
models and accuracy class is 15%
After the motor mechanism completes energy storage, the closing coil
Closing Coil
promptly closes the breaker by releasing the spring in the mechanism
Air type circuit breakers, excluding than manual type, can be remote
Shunt Trip controlled with shunt trip coil.
Cable wire type mechanical lock is used for cross locking of 2 circuit
breakers in vertical or horizontal positions. The purpose of this
Mechanical Lock application is to prevent accidental ON-1 position of one circuit breaker,
while the other is in ON-1 position.
Phase barrier prevents the arc which may arise and result in short-circuit
Phase Barrier between phases in advance.
Auxiliary Switch Auxiliary switch contacts to monitor On/Off position of ACB remotely.
312
267
57
344
13,5 13,5
345
272
432
15
375
360
267
114
47,5
350
13,5 13,5
298
405
350
272
40
432
18
75
40 15
40
Ø5
360
267
311
402
30
258
114
13
50
34
404
150 70 13,5 515 13,5
Panel Frame
298
515
298
12
Ø
150
5,5
Assembling Gauge
Busbar Connection
528
21,5
Ø5
155
30
439
302
268
258
378
362
112
20
92
70
47
440 55
197,5
180
5,5
140
50
Ø1
1
175
197,5
11x17
14
5
Ø
Assembling Gauge
13
Busbar Connection