THERMAL THERMAL

COMPONENT HEAT TRANSFER AREA HEAT LOSS


STRUCTURAL CONDUCTIVITY RESISTEANCE R
FLOOR CHOOSEN MATERIAL THICKNESS AxU
COMPONENTS COEFF. COEFF. (W/m²K) A (m²)
d (m)
λh (W/mK) (m²K/W) (W/K)

Ri - - 0.170
(Heat loss 0,5xAxU ) Linoleum Coating 0.002 0.17 0.012
0.4569
Cement Screed 0.05 1.4 0.036
Thermal Insulation Material(XPS) 0.05 0.03 1.667
BASEMENT SLAB

Reinf.Concrete(Foundation) 0.5 2.2 0.227


192 43.863
Protective Concrete 0.01 1.65 0.006 U<0,57
Polyvinyl Chloride (PVC) 0.002 0.19 0.011
Blinding Concrete 0.1 1.65 0.061
Re 0.000
Coefficient 0.50
BASEMENT FLOOR

Ri - - 0.130
SHEAR WALLS

Lime-Cement Plaster 0.02 1 0.020


BASEMENT

0.5160
Shear Walls 0.2 2.2 0.091
Thermal Insulation Material(XPS) 0.05 0.03 1.667 148.49 76.616
Polyvinyl Chloride (PVC) 0.002 0.19 0.011 U<0,57
Lime-Cement Plaster 0.02 1 0.020
Re - - 0.000
REINF. ELEMENTS

Ri - - 0.130
Lime-Cement Plaster 0.02 1 0.020
(COLUMNS)

0.4874
Reinf. Concrete (Column) 0.45 2.2 0.205
Thermal Insulation Material(XPS) 0.05 0.03 1.667 25.11 12.238
Polyvinyl Chloride (PVC) 0.002 0.19 0.011 U<0,57
Lime-Cement Plaster 0.02 1 0.020
Re - - 0.000
Ri - - 0.000
CEILING / SLAB

No aggregate plaster 0.01 0.51 0.020


0.7996
Reinf. Concrete.slab 0.15 2.2 0.068
Thermal Insulation Material(XPS) 0.02 0.03 0.667 0.000000
Cement Screed 0.04 1.2 0.033 R>0,7
Linoleum Coating 0.002 0.17 0.012
CEILIN
Re - - 0.000
TOTAL 365.6 132.718
THERMAL THERMAL
COMPONENT RESISTEANC HEAT TRANSFER AREA HEAT LOSS
STRUCTURAL CONDUCTIVITY
FLOOR CHOOSEN MATERIAL THICKNESS AxU
COMPONENTS
d (m)
COEFF. E R COEFF. (W/m²K) A (m²) (W/K)
λh (W/mK) (m²K/W)

Ri - - 0.1300
Lime-Cement Plaster 0.02 1 0.0200

Autoclaved Aerated Concrete 0.2 0.2 1.0000 0.347625

WALLS Thermal Insulation 97.01 33.723


0.05 0.03 1.6667
Material(XPS)
Lime-Cement Plaster 0.02 1 0.0200 U<0,57
GROUND FLOOR

Re - - 0.0400

WINDOWS Windows (PVC Joinery 4 compartments) 1.56 28.8 44.928


DOORS (Wood Framed Single Glass Door, Filled with Glass Wool) 4 3.52 14.08
Ri - - 0.1300
Lime-Cement Plaster 0.02 1 0.0200
Reinf. Concrete 0.3 2.2 0.1364 0.496764
BEAMS Thermal Insulation 19.16 9.518
0.05 0.03 1.6667
Material(XPS)
Lime-Cement Plaster 0.02 1 0.0200 U<0,57
Re - - 0.0400
Ri - - 0.130
Lime-Cement Plaster 0.02 1 0.020
Reinf. Concrete 0.45 2.2 0.205 0.480489
COLUMNS Thermal Insulation 25.11 12.065
0.05 0.03 1.667
Material(XPS)
Lime-Cement Plaster 0.02 1 0.020 U<0,57
Re - - 0.040
TOTAL 173.6 114.314
THERMAL THERMAL
COMPONENT RESISTEANC HEAT TRANSFER AREA HEAT LOSS
STRUCTURAL CONDUCTIVITY
FLOOR CHOOSEN MATERIAL THICKNESS AxU
COMPONENTS
d (m)
COEFF. E R COEFF. (W/m²K) A (m²) (W/K)
λh (W/mK) (m²K/W)

Ri - - 0.1300
Lime-Cement Plaster 0.02 1 0.0200
0.347625
Autoclaved Aerated Concrete 0.2 0.2 1.0000
WALLS 96.53 33.556
Thermal Insulation Material(XPS) 0.05 0.03 1.6667
Plaster 0.02 1 0.0200 U<0,57
Re - - 0.0400

WINDOWS Windows (PVC Joinery 4 compartments) 1.56 32.8 51.168

Ri - - 0.1300
Lime-Cement Plaster 0.02 1 0.0200
0.496764
Reinf. Concrete 0.3 2.2 0.1364
BEAMS 19.16 9.518
Thermal Insulation Material(XPS) 0.05 0.03 1.6667
Lime-Cement Plaster 0.02 1 0.0200 U<0,57
1. FLOOR

Re - - 0.0400
Ri - - 0.130
Lime-Cement Plaster 0.02 1 0.020
0.480489
Reinf. Concrete 0.45 2.2 0.205
COLUMNS 25.11 12.065
Thermal Insulation Material(XPS) 0.05 0.03 1.667
Lime-Cement Plaster 0.02 1 0.020 U<0,57
Re - - 0.040
Ri - - 0.13
Lime-Cement Plaster 0.02 1 0.02
Reinforcement Slab 0.15 2.2 0.07 0.2297 192 35.2750
Sloping Concrete 0.03 1.65 0.02
SLOPING ROOF Thermal Insulation Material(XPS) 0.12 0.03 4.00
Water Ins. Mate. (Polymer Bitumen
Waterproofing Sheet) 0.004 0.19 0.02
U<0,38
Cement Screed 0.02 1.4 0.01
Ceramic Clinker 0.02 0.96 0.02
Re 0.08 0.80
TOTAL 365.6 141.582
Total Volume (Vgross) (m³) 1785.600
Heat loss due to conduction and convection (Ht) (W/K) 388.614
Heat loss due to ventilation (Hv) (W/K) 288.732
Overall heat loss (W/K) 677.346
Total Area (At) (m²) 904.800
Heat Loss Heat Gain
Overall Heat Temperature Internal Heat Solar Energy
Heat Losses Overall
Loss Difference Gain Gain
H = HT+Hv θi - θe H x (θi - θe) Фi Фs Фt = Ф i + Ф s
" (W/K) (K, ºC) (W) (W) (W) (W)
January 17.1 11582.62 1506.05 4363.01
February 15.6 10566.60 1895.81 4752.77
March 12.7 8602.29 2320.90 5177.86
April 7.2 4876.89 2615.04 5472.00
May 2 1354.69 3100.80 5957.76
June -2.5 -1693.36 3283.58 6140.54
677.35 2856.96
July -4.9 -3319.00 3187.58 6044.54
August -4.3 -2912.59 2951.04 5808.00
September 0.1 67.73 2422.66 5279.62
October 5.9 3996.34 1920.00 4776.96
November 11.5 7789.48 1425.02 4281.98
December 16.2 10973.01 1314.05 4171.01

Qyear*0,278 23525342.024 kJ
Qyear (kWh) 23525.342024 (kWh)
Q (Q year/Vgro 13.175034736 kWh/m³ Q/Q'=
At/Vgross 0.5067204301 1/m
Q' 14.986424731 kWh/m³

3
Vgross= 1785.6 m
Ht= 388.61446955 W/K
Hv= 288.73152 W/K
H= 677.34598955 W/K
2
An 571.392 m
2
At 904.8 m
Gain Utilization Heat Energy
HEAT BALANCE RATIO
Factor Requirement

γ ηmonth Qmonth
(-) (-) (kJ)
0.377 0.92968 19,508,441.93 January
0.450 0.89174 16,403,077.44 February
0.602 0.81012 11,424,525.56 March
1.122 0.58986 4,274,737.07 April
4.398 0.20338 370,598.31 May
-3.626 0.00000 0.00 June
-1.821 0.00000 0.00 July
-1.994 0.00000 0.00 August
77.946 0.01275 1,121.42 September
1.195 0.56681 3,340,300.90 October
0.550 0.83783 10,891,302.76 November
0.380 0.92798 18,409,427.08 December
Qyear = 84,623,532.46

0.879131278605911 (B Type)
θi θe θi - θe Inorth Isouth Ie-w ri gi Apnorth Apsouth Ape-a Фs
20 2.90 17.10 26 72 43 1506.05
20 4.40 15.60 37 84 57 1895.81
20 7.30 12.70 52 87 77 2320.90
20 12.80 7.20 66 90 90 2615.04
20 18.00 2.00 79 92 114 3100.80
20 22.50 -2.50 83 95 122 3283.58
0.8 0.6 4 19.2 38.4
20 24.90 -4.90 81 93 118 3187.58
20 24.30 -4.30 73 93 106 2951.04
20 19.90 0.10 57 89 81 2422.66
20 14.10 5.90 40 82 59 1920.00
20 8.50 11.50 27 67 41 1425.02
20 3.80 16.20 22 64 37 1314.05