You are on page 1of 10

www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.

4
Company: Page: 1
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:
Specifier's comments:

1 Input data
Channel type HAC-C 50/30 400 F
bolt HBC-50/30 8.8F, M12 x 50 mm
Effective embedment depth hef = 94 mm
Channel specification Length: 400 mm, anchor spacing: 175 mm, projection: 25 mm,
width: bch = 50 mm, height: hch = 30 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-17/0336 (2D)
Issued I Valid 5/19/2020 | -
Standard EN 1992-4
Base material uncracked, C35/45, fck,cylinder = 35.0 N/mm2, h = 500 mm
Reinforcement Exist. Reinf.: Widely spaced
No edge reinf. present
Reinf. to control splitting not present
Tolerance data tolerance interval: -350 mm/350 mm
most unfavorable tolerance: -88 mm

2 Overall Result
Design ok! (Maximum utilization: 97%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-50/30 8.8F, M12 x 50 mm
Profile: -
Standoff: No standoff
Plate dimensions: 275 mm x 100 mm x 8 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 17.700 0.000 0.000 0.000
1.2 17.700 0.000 0.000 0.000
1.1 1.2
Tension
max. concrete compressive strain: - [‰]
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(137.5/50.0): 35.400 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 298 [mm] ≥ s
Iy = 57781 [mm4]
s = 175 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 94

a1 a2 a3

25 175 175 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 16.534 0.000
a2 14.869 0.000
a3 3.997 0.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 16.534 17.222 97 ok
Connection anchor-channel 16.534 17.222 97 ok
Channel lip 17.700 25.000 71 ok
Channel bolt 17.700 44.933 40 ok
Flexure channel N/A N/A N/A N/A
Pull-out 16.534 57.820 29 ok
Concrete cone 14.869 16.181 92 ok
Concrete splitting 14.869 24.013 62 ok
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


16.534 31.000 1.800 17.222

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


16.534 31.000 1.800 17.222

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


175 98 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
17.700 45.000 45.000 1.800 25.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 6
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
17.700 67.400 1.500 44.933

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
236
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
16.534 10.5 35.0 86.730 1.500 57.820

5.1.3 Concrete cone (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


11.6 35.0 94 62.544
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
175 399 0.633 75 199 0.613
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
350 - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
14.869 24.271 1.500 16.181

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 7
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:
5.1.4 Concrete splitting (Anchor a2, Channel a), concrete cone relevant (EN 1992-4 section 7.4.1.6)
NRk,sp
NaEd ≤ NRd,sp =
gMsp
NRk,sp = N0Rk · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N · y h,sp
N0Rk = min(NRk,p, N0Rk,c) = Min(86.730, 62.544) = N0Rk,c
1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,sp N0
i=1

scr,sp = 2 · ccr,sp
0.5
y ch,e,N = (cc ) 1
cr,sp
≤ 1.0

0.5
y ch,c,N,1 = (cc )2,1
cr,sp
≤ 1.0

0.5
y ch,c,N,2 = (cc )2,2
cr,sp
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

( (h ) ) ≤ 2.0
2/3 2/3
y h,sp = (hh )min
≤ max 1.0 ; ef + ccr,sp
hmin

N0Rk [kN] s [mm] scr,sp [mm] y ch,s,N c1 [mm] ccr,sp [mm] y ch,e,N
62.544 175 564 0.558 75 282 0.516
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
350 - 1.000 1.000 1.000
h [mm] hmin [mm] y h,sp
500 120 2.000
NaEd [kN] NRk,sp [kN] gMsp NRd,sp [kN]
14.869 36.020 1.500 24.013

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 8
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm N/A N/A N/A N/A
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular N/A N/A N/A N/A
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - N/A N/A N/A N/A
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular N/A N/A N/A N/A
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular N/A N/A N/A N/A
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

Remarks and warnings


• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• A longitudinal reinforcement should be provided along the edge of the member!
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 97%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 9
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-50/30 8.8F, M12 x 50 mm
Plate dimensions: 275 mm x 100 mm x 8 mm Bolt length: 50 mm
Profile: - Bolt diameter: 12 mm
Anchorplate design calculated: no Diameter hole: 14 mm
Installation torque: 0.025 kNm

138 138

50

50
1.1 1.2 x
50

50

50 175 50

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.htmlPROFIS Anchor Channel 1.7.4
Company: Page: 10
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 06/10/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan