Professional Documents
Culture Documents
91
www.hilti.com.hk
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
Specifier's comments:
1 Input data
Anchor type and size: HST3-R M12 hef2
Return period (service life in years): 50
Item number: 2105871 HST3-R M12x125 50/30
Gap filling with Hilti Filling Set M12
Effective embedment depth: hef,act = 70.0 mm (hef,limit = - mm), hnom = 80.0 mm
Material: A4
Approval No.: ETA 98/0001
Issued I Valid: 20/7/2023 | -
Proof: Based on design method EN 1992-4, Mechanical with a load factor 2 and global safety factor 3
Stand-off installation: eb = 0.0 mm (no stand-off); t = 10.0 mm
Baseplate :
R lx x ly x t = 500.0 mm x 295.0 mm x 10.0 mm; (Recommended plate thickness: not calculated)
R
- The anchor calculation is based on a rigid baseplate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
44.300 1.000 44.300 3.000 14.767 4.875
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
74,550 44,100 105.0 210.0 2.780 50.00
Group anchor ID
2, 4
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the
baseplate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained
above. The proof if the rigid baseplate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be
checked for agreement with the existing conditions and for plausibility!
• Design is only valid if hole is filled to remove clearance, clearance as per EN 1992-4 Table 6.1
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The anchor resistances used for this design are ONLY valid if the Seismic set will be installed on the jobsite as per IFU when the Seismic
washer was selected.
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
7 Installation data
2 2
Baseplate, steel: GB Q390; E = 205,000.00 N/mm ; fyk = 350.00 N/mm Anchor type and size: HST3-R M12 hef2
Profile: Rectangular hollow, 200 x 100 x 10,0; (L x W x T) = 200.0 mm x 100.0 Item number: 2105871 HST3-R M12x125 50/30
mm x 10.0 mm
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 60 Nm
Plate thickness (input): 10.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 100.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 120.0 mm
Cleaning: No cleaning of the drilled hole is required
Hilti HST3 stud anchor with 70 mm embedment, M12 hef2, Stainless steel, installation per ETA 98/0001, with annular gaps filled with Hilti
Filling Set or any suitable gap solutions
y
250.0 250.0
95.0
147.5
3 4
77.5
x
150.0
147.5
1 2
50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.91
www.hilti.com.hk
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: SP3_Copy - deatil S1 Date: 1/3/2024
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan