You are on page 1of 82

Product Catalogue

Asia Pacific 2013/2014

www.belimo.com 

Index

Total solutions from a single source


1

page 5

Belimo New Products


- New Generation Globe Valve Actuators
2
- Stainless Steel CCV

page 6

HVAC Damper Actuators


- General Damper Actuators
3
- RobustLine
- Fast-Running Damper Actuators
- Linear and Full Rotary Damper Actuators
- Mechanical Fail-Safe Damper Actuators
- Electrical and Mechanical accessories page 8

Fire and Smoke Protection, Smoke Extraction


- Fire and Smoke Spring-Return Damper Actuators
4
- Smoke Extraction Non-Spring Return Damper Actuators
- SBS(E)-Control and accessories
page 25

HVAC Variable Air Volume Control


- VAV Compact
5
- VAV and Room Control Module

page 33

Rotary Actuators and Valves


- CCV
6
- Steam Valves
- PICCV/EPIV and Energy Valves
- Rotary Actuators and Butterfly Valves page 37

Linear Actuators and Valves


- H series Globe Valves
7
- Linear Actuators

page 61

Conversion and Retrofit


- Linear Actuators (AV/NV series) Retrofit
8
- Linkage selection guide

page 67

Supplementary Products
- Fan Coil Valves and Actuators
9
- Energy Meters

page 72


Cost-effective, environment conservation,
system optimisation, universal and simple adaptation
Belimo Actuators and Valves


Total solutions from a single source
1

Air applications Water applications


1. General Damper Actuator for air damper 6. Pressure Independent Characterised Control Valve Range
2. Mechanical/Electronic Fail-Safe Damper Actuator for air application 7. Characterised Control Valve
3. Fire Protection Damper with actuator 8. 3-way Globe Valve (DN65...150)
4. VAV-Box with VAV Compact Actuator 9. Butterfly Valve
5. VAV-Box with universal dynamic actuator

Fan Air Air Boiler Pump Speed Cooling Chiller Chilled/Heating


Heater Cooler adjusted tower water reservoir
pump

The above diagram illustrates our standard product portfolio and does not necessarily reflect real systems. 
Belimo New Products

New Generation Globe Valve Actuators ( Retrofit )


Linear Actuators with LV..-RE 500N
NV..-RE 1000N
SV..-RE 1500N
AVK..-RE 2000N
EV..-RE 2500N
RV..-RE 4500N

Benefits
.
. Adjustable stroke

. Universal linkage
Simple mounting and efficient ordering:
- Linkage incorporated with its actuator

. - Manual override by using hexagon key

. Belimo Quality Product New Generation

. Flexible signalling adjusted by PC-Tool (for -MF type)


Higher close-off pressure achieved
Globe Valve Actuator
* Parts of NG Globe Valve Actuators will be available in mid of 2013.

Stainless Steel CCV ( SSCCV )


Benefits
.
. Valve body stainless steel 316

. Higher corrosion resistance

. No stress cracking, no dezincification


High temperature range

SSCCV
* SSCCV will be available in mid 2014.


3

Reliability and Safety Performance


Belimo Mechanical/Electronic Fail-Safe Damper Actuators
HVAC Damper Actuators

Belimo proudly introduces the new generation actuators to the market. It sums up 30 years’ experience of developing and producing
HVAC actuators for global markets and establishes a higher standard of performance with state-of-the-art technology.

The new product portfolio has some unique features like clear basic types, a new motor with a greater output, a longer service life
and less energy consumption as well as universal operating components.

The new generation now makes installation and operation even more efficient. Retrofitting with older products and a five-year war-
ranty are guaranteed. The concept of launching this new range is to give more benefits, reduce handling costs and increase value
and performance to customers by a unified platform. In other words, it just makes life easier!

Technology
The new generation actuator range was developed with enormous effort and manpower invested by Belimo. The new products are
equipped with a super integrated ASIC electronic chip, new servo control algorithm, high endurance materials and the latest designed
brush-less DC motor. All the specifications have become more advanced and accurate.

With stringent test procedures and newly designed processes for production testing, the new generation is setting a new standard in
the HVAC Actuator industry.

Compatibility
All new generation actuators are reversible. The accessories which match the old dimensions are still available.

Any of the new accessories, e.g. auxiliary switches, potentiometers, clamps and fittings are compatible to the whole new range.

Customers will be able to reduce inventory level, which means lower cost, faster delivery and the same set of installations.


HVAC Damper Actuators

Actuators for Fail-Safe Actuators for Damper Actuators with


general damper control dampers with a safety function Multi-Function Technology
[MF, MP, MFT(2)] 3
The wide range of Damper Actua- For air dampers with a safety function, Belimo There are many projects and applica-
tors offered by Belimo covers all offers a range of special Mechanical Fail-Safe tions which could benefit considerably
specific needs to motorise the op- Actuators which can ensure that, in the event of from the use of actuators equipped with
eration of shut-off dampers and a power failure, the dampers close automatically Belimo’s intelligent MFT electronics.
control dampers in HVAC systems. and quickly and remain tightly sealed. MF, MP, MFT(2) allows Damper Actua-
The actuators come in a wide range tors to be adapted to meet the require-
of voltages and torque outputs with The Mechanical Fail-Safe Actuators come in ments for installation so that the damp-
either Open/Close, 3-point or mod- three classes of output — the compact TF/LF.. er functions can be optimised precisely.
ulating versions. The actuators can series for small dampers, the NFU.. series for Its ability to transmit operating signals
be supplied with or without auxiliary medium-sized dampers and the SFU../EFU.. se- and status signals to the plant control
switches. ries for large dampers. system also helps to reduce operating
and maintenance costs. Moreover MP
actuators are easy to incorporate into
field bus systems, either with or with-
Belimo’s innovation and advancement in Super- out auxiliary switches.
Cap technology has enabled the release of a new
actuator with electronic fail-safe functionality.

The New Electronic Fail-Safe Actuators feature


high torque (GK../40Nm), Fail-Safe position that
can be set 0...100% in 10% increments, LED sta-
tus and lower power consumption offering you
new solutions for HVAC controlling.

Typical applications
Air duct system Terminal control

Central air-conditioning unit


CMU Damper Actuators 2Nm

CMU Damper Actuators 2Nm


Universal clamp for damper spindles 6…12.7mm

Open/Close Modulating
2Nm
Damper Actuators CMU24(-F8/-F10) CMU24(-F8/-F10)-T CMU230(-F8/-F10) CMU24-SR-R
AC 100...240V
AC/DC 24V
Running time 75s/90º, constant
Open/Close or 3-point
Control signal DC (0)2...10V
Feedback signal DC 2...10V, max. 1mA
Degree of protection: IP54
IP20 (-T)
Noise level max. 35dB(A)
Universal clamp
Form-fit 8x8mm (-F8)
Form-fit 10x10mm (-F10)
Ambient temperature -30...+50ºC
Cable 1m, 0.75mm2
Terminal connection (-T)
Angle of rotation
Without limiters: Endless
With limiters: Fixed 315º or 0...287.5º with
mechanical end stops, can be
adjusted in 2.5º increments
Position indication, mechanical pluggable
remote visible, with integrated magnet for gear
disengagement
Manual override
Gear disengagement with magnet

CMU24-SR-R: control signal Y=0 V position at the right side, the left side is available on request.

10
LMU Damper Actuators 5Nm

LMU Damper Actuators 5Nm, 95º angle of rotation


Universal clamp for damper spindles 6…20mm

3
Open/Close
Damper Actuators 5Nm
LMU24 LMU24-S LMU24P5 LMU24-F LMU24-T LMU72 LMU230 LMU230-S LMU230-F
AC 100...240V
DC 48...110V
AC/DC 24V
Running time 150s
Open/Close or 3-point
1 SPDT auxiliary switch feedback
Feedback potentiometer 5kΩ
Degree of protection: IP20
Degree of protection: IP54
Noise level max. 35dB(A)
Universal V-clamp
Form-fit 8x8mm
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Terminal connection
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

LMU Damper Actuators 5Nm, 95º angle of rotation


Universal clamp for damper spindles 6…20mm

Modulating
5Nm
Damper Actuators LMU24-SR LMU230-SR
AC 100...240V
AC/DC 24V
Running time 150s
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 1mA
Degree of protection: IP54
Noise level max. 35dB(A)
Universal V-clamp
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

11
NMU Damper Actuators 10Nm

NMU Damper Actuators 10Nm, 95º angle of rotation


Universal clamp for damper spindles 8…26.7mm

Open/Close
Damper Actuators 10Nm
NMU24 NMU24-S NMU24-T NMU230 NMU230-S
AC 100...240V
AC/DC 24V
Running time 150s
Open/Close or 3-point
1 SPDT auxiliary switch feedback
Degree of protection: IP20
Degree of protection: IP54
Noise level max. 35dB(A)
Universal V-clamp
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Terminal connection
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

NMU Damper Actuators 10Nm, 95º angle of rotation


Universal clamp for damper spindles 8…26.7mm

Modulating
10Nm
Damper Actuators NMU24-SR NMU230-SR
AC 100...240V
AC/DC 24V
Running time 150s
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 1mA
Degree of protection: IP54
Noise level max. 35dB(A)
Universal V-clamp
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

12
SMU Damper Actuators 20Nm

SMU Damper Actuators 20Nm, 95º angle of rotation


Universal clamp for damper spindles 10…20mm

3
Open/Close
20Nm
Damper Actuators SMU24 SMU24-S SMU230 SMU230-S SMU230-F
AC 100...240V
AC/DC 24V
Running time 150s
Open/Close or 3-point
1 SPDT auxiliary switch feedback
Degree of protection: IP54
Noise level max. 45dB(A)
Universal V-clamp
Form-fit 12x12mm
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

SMU Damper Actuators 20Nm, 95º angle of rotation


Universal clamp for damper spindles 10…20mm

Modulating
20Nm
Damper Actuators SMU24-SR SMU230-SR
AC 100...240V
AC/DC 24V
Running time 150s
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 1mA
Degree of protection: IP54
Noise level max. 45dB(A)
Universal V-clamp
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

13
GMU Damper Actuators 40Nm

GMU Damper Actuators 40Nm, 95º angle of rotation


Universal clamp for damper spindles 12…26.7mm

Open/Close Modulating
40Nm
Damper Actuators GMU24 GMU230 GMU24-SR
AC 100...240V
AC/DC 24V
Running time 150s
Open/Close
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 1mA
Degree of protection: IP54
Noise level max. 45dB(A)
Universal V-clamp
Ambient temperature -30...+50ºC
Cable 1m, 0.75m2
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button
Integrated adjustable mechanical end stops

NM..P../SM..P.. series RobustLine IP66+IP67 Actuators, 95º angle of rotation

IP66+IP67 protection
RobustLine NM24P.. NM230P.. SM24P.. SM230P..
Torque 8Nm
18Nm
AC 100...240V
AC/DC 24V
Running time 150s
Open/Close or 3-point
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 1mA
Degree of protection: IP66+IP67
Noise level max. 35dB(A)
Noise level max. 45dB(A)
Universal V-clamp
Form-fit
Ambient temperature -30...+50ºC
Halogen-free cable 1m, 0.75mm2
Humidity test: 100% RH
Position indication mechanical, remote visible
Direction of rotation reversible (right/left)
Manual override with push button

14
Fast-Running Actuators Q.. series

LMQU../NMQU../SMQU../SMDU230 Fast-Running Damper Actuators


4Nm/8Nm/16Nm, 95° angle of rotation
Universal clamp for damper spindles
3
Open/Close Modulating
Damper Actuators LMQU24 NMQU24 SMQU24 SMDU230 LMQU24-SR NMQU24-SR SMQU24-SR
Torque 4Nm
8Nm
16Nm
AC/DC 24V
AC85...265V
Running time 2.5s/95º
4s/95º
7s/95º
20s/95º
Open/Close
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 0.5mA
Degree of protection: IP54
Noise level max. 52dB(A)
Noise level max. 55dB(A)
Universal clamp
Ambient temperature -30...+40ºC
Cable 1m, 0.75mm2
Position indication, mechanical, remote visible
Direction of rotation reversible with switch
Integrated adjustable mechanical end stops

15
Linear and full rotation actuators

LH../SH.. Linear Actuators 150N, 450N

Power supply AC/DC 24V AC 100...240V


Control Open/Close or 3-point Modulating Open/Close or 3-point
LH..series, 150N LHU24-602) LHS24 LHU24-MF603) LHS24-SR LHS230
SH..series, 450N SHS24 SHS24-SR SHS230
Stroke (mm)1) 60 100 200 60 100 200 100 200
Stroke fixed
Stroke adjustable (steps 20mm)
Running time: 90s/60mm
150s/100mm
120s, 90s or 75s/100mm for LHS..
Cable 0.75mm 2

Sound power level <35dB(A) (SHS..: <50dB(A))


Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
Manual override with push button
Reversible direction of stroke
Ambient temperature -30...+50ºC
Degree of protection class: IP54

1) 300mm stroke Linear Actuator is available on request.


2) ..HU for standard product, ..HS for customised product.
3) This product is available on request.

LU.. Full Rotary Actuators 3Nm

Power supply AC/DC 24V AC 100...240V


Control Open/Close or 3-point Modulating Open/Close or 3-point
LU.. series LUS24 LUS24-SR LUS230
Torque 3Nm
Angle of rotation: 330º
endless
Running time: 150s/360º
120s, 90s or 75s/360º (customised)
Cable 0.75m2
Sound power level max. 35dB(A)
Form-fit 8x8mm/10x10mm/12x12mm
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
Manual override with push button
Reversible direction
Ambient temperature -30...+50ºC
Degree of protection: IP54

Please contact your nearest Belimo sales representative for detailed information.

16
Belimo customisation

Our flexibility is beyond your expectations

Market description: LMS230-SR


Type code: L M S 45 0 1 01 0 0 0 2 3
6 Packaging
5 Running Time
4 Electrical Connection
3 Mechanical Interface

2 Label on Housing

1 Actuator

S Customised Product

Types/Voltage/Function

. Standard Damper Actuator


. CM/LM/NM/SM/GM
. Actuator for valve LR/NR/SR/GR
. Linear Actuator LH/SH
. 360º rotating actuator LU
. Open/Close, 3-point, modulating, MF, MP-Bus, Lon

1 Actuator/Housing Color

. Orange: Belimo products . Maximised flexibility


for all customers . All the features you want
. Immediate availability of samples
. Grey:
. Availability no longer related to quantity
Specific customer
products with Belimo . Any products with your own brand or identity at any time
logo or customer logo
and type code Refer to technical datasheets for details.
New options for customisation are continuously added.
Please get updates from a Belimo sales representative.

2 Label on Housing
4 Electrical Connection 6 Packaging
. Transparent label
. Blue label . Single packing
. Terminals IP20/IP54
. Black label . Bulk packing
. 1/3/5m PVC cables
. 1/3/5m Halogen free cables
. J6 connector
. 4...20mA PVC cables

3 Mechanical Interface

. Single side clamp


5 Running Time
. Turnable clamp
. 150s/90º LM/NM/SM/GM
. 6×6/8×8/10×10/12×12/16×16mm
. 90s/90º LM/NM/SM
Form-fit (with rotation limits)*
. 75s/90º CM
. 45s/90º CM/LM/NM
. 35s/90º CM/LM

* 6x6mm Form-fit just for CM... series.



Please contact your nearest Belimo sales representative for detailed information

17
TF/LF Mechanical Fail-Safe Damper Actuators 2.5/4Nm

TF Mechanical Fail-Safe Damper Actuators 2.5Nm, 95º angle of rotation


Universal clamp for damper spindles 6…12mm

Mechanical Fail-Safe Open/Close 3-point Modulating


2.5Nm
Damper Actuators TF24 TF24-S TF230 TF230-S TF24-3 TF24-SR
AC 100...240V
AC/DC 24V (TF24-3 only AC 24V)
Running time: motor <75s (0...2.5Nm)
motor <150s (0...2.5Nm)
spring return <25s
Single-wire control
3-point control
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
Integral, potential-free auxiliary switch 0...100% adjustable
Direction of rotation reversible (right/left)
Integrated adjustable mechanical end stops
Conduit connector accessory (by separate order)
Degree of protection: IP42

LF Mechanical Fail-Safe Damper Actuators 4Nm, 95º angle of rotation


Universal clamp for damper spindles 8…16mm

Mechanical Fail-Safe Open/Close 3-point Modulating


4Nm
Damper Actuators LF24 LF24-S LF120 US LF120-S US LF230 LF230-S LF24-3 LF24-MFT2 LF24-SR
AC 120V
AC 230V
AC/DC 24V
Running time: motor 40...75s (0...4Nm)
motor 150s, adjustable
motor 150s
spring return approximate 20s
Single-wire control
3-point
Control signal Y 0.5...32V, adjustable
Control signal Y DC (0)2...10V
Feedback signal U: DC 0.5...32V, adjustable
DC 2...10V
Integrated MP data bus interface
Input for active/passive sensors, switches
Integral, potential-free auxiliary
0...100% adjustable
Direction of rotation reversible (right/left)
Integrated adjustable mechanical end stops
Conduit connector
Degree of protection: IP54

18
NFU/SFU/EFU Mechanical Fail-Safe Damper Actuators

NFU/SFU Mechanical Fail-Safe Damper Actuators, 95º angle of rotation

10Nm Open/Close Modulating 3


Mechanical Fail-Safe NFU NFU-S2 NFU24-SR
Damper Actuators 20Nm SFU SFU-S2 SFU24-SR
AC 24...240V/DC 24...110V
AC/DC 24V
Running time: motor <75s
motor 150s, independent of load
spring return <20s
Single-wire control
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
2 SPDT, 1mA...3(0.5)A, AC 250V,
one fixed at 10%, one adjustable 10...90%
Direction of rotation reversible (right/left)
Degree of protection: IP54

EFU Mechanical Fail-Safe Damper Actuators, 95º angle of rotation

Open/Close Modulating
Mechanical Fail-Safe 30Nm
Damper Actuators EFU24-S2 EFU230-S2 EFU24-SR
AC 230V
AC/DC 24V
Running time: motor 60s
motor 150s, independent of load
spring return <20s
Single-wire control
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
2 SPDT, 1mA...3(0.5)A, AC 250V
one fixed at 10%, one adjustable 10...90%
Direction of rotation reversible (right/left)
Degree of protection

19
Electrical accessories

Actuators
CMU LMU NMU SMU GMU TF LF NFU SFU
S..A.. Auxiliary switch, add-on
S1A 1 SPDT 3A(0.5A), AC 250V
S2A 2 SPDT 3A(0.5A), AC 250V
S2A-F 2 SPDT 3A(0.5A), AC 250V
P..A.. Feedback potentiometer, add-on
P140A.. 140Ω
P500A.. 500Ω
P1000A.. 1000Ω
P2800A.. 2800Ω
P5000A.. 5000Ω
P10000A.. 10000Ω
P200A-F 200Ω
SGA24 Positioner for suface mounting 1) 1) 1) 1) 1) 1) 1) 1) 1)
0...100%
Reversible operating range DC 0...10V
or DC 2...10V
SGE24 Positioner for rack mounting 1) 1) 1) 1) 1) 1) 1) 1) 1)
0...100%
Reversible operating range DC 0...10V
or DC 2...10V
SGF24 Positioner for front-panel mounting 1) 1) 1) 1) 1) 1) 1) 1) 1)
0...100%
Reversible operating range DC 0...10V
or DC 2...10V
ZAD24 Digital position indicator for front-panel mounting 1) 1) 1) 1) 1) 1) 1) 1) 1)
0...99%
Front size 72x72mm
Operating range DC 2...10V

1) For ..-SR model

20
Mechanical accessories

Actuators
LMU NMU SMU GMU TF LF NFU SFU
AN-20 Actuator arm
3

AH-25 Actuator arm

AH-GMA Actuator arm

AV6-20 Shaft extension


Length approximately 170mm
For damper spindles 6...20mm
Extension 10mm
AV8-25 Shaft extension
Length approximately 250mm
For damper spindles 8...25mm
Extension 20mm
IND-AFB NFU/SFU.. position indicator

K6-1 Spindle clamp for LF..


For damper spindles 16...20mm

K7-2 NFU/SFU.. standard clamp


1/2”,3/4”,1.05”

K-ENSA Spindle clamp


Damper spindle 8...20mm

K-NA Reversible spindle clamp


Damper spindle 8...20mm

K-SA Reversible spindle clamp


Damper spindle 10...20mm

KG8 Ball joint


Suitable for damper crank arm KH8
For round steel rod with 8mm
Zinc-plated steel
KG10A Ball joint
Suitable for damper crank arm KH8
For round steel rod with 10mm
Zinc-plated steel

21
Mechanical accessories

Actuators
LMU NMU SMU GMU TF LF NFU SFU
KH10 Universal crank arm
Galvanised steel, for damper spindles
Clamp range 14...25mm
Slot width 8.2mm
KH12 Universal crank arm for 1.05” diameter shafts

KH8 Universal crank arm


Zinc-plated steel, for damper spindles
10...18mm or square 10...14mm
Slot width 8.2mm
KH-AFB NFU/SFU.. crank arm, 3/4” shafts

KH-LF Damper crank arm


For damper spindles 8...16mm

KH-LF1 Damper crank arm


For damper spindles 16...20mm

SB-TF Screw fastening set


For fixed mounting

ZDB-LF Angle of rotation limiter and pointer

ZDB-TF Angle of rotation limiter

ZF8-LF Shaft adapter


For damper spindles, with form-fit 8x8mm

22
Mechanical accessories

Actuators
LMU NMU SMU GMU TF LF NFU SFU
ZG-118 NFU/SFU.. mounting bracket
3

ZG-AFB NFU/SFU.. crank arm adapter kit

ZG-AFB118 NFU/SFU.. crank arm adapter kit

ZG-GMA Mounting kit


For flat and side mounting

ZG-LF1 Damper linkage kit


For side mounting (with 2 ball joints KG8)

ZG-LF3 Damper linkage kit


For side mounting (with 2 ball joints KG8)

ZG-NMA Mounting kit


For flat and side mounting

ZG-SMA Mounting kit


For flat and side mounting

ZG-TF1 Damper linkage kit


For flat mounting

Z-AF Retrofit adapter for NG NFU/SFU.. while


replacing old NF/AF/AFR..

ZF10-NSA-F 10x10 form-fit adapter


mutipack 20 pieces

ZF12-NSA-F 12x12 form-fit adapter


mutipack 20 pieces

ZF16-NSA-F 16x16 form-fit adapter


mutipack 20 pieces

23
MF, MP or MFT(2) accessories

Actuators VAV Compact Actuators


LMU NMU SMU GMU LF NFU SFU LMV NMV
Fan Optimiser VAV/CAV system solution for energy-optimised
fan regulation.
Room controller input DDC: 0...10/2...10V/MP-Bus
VAV controller input/output: MP-Bus
Frequency converter output: 0...10V
LC display for settings and diagnostics
MFT-P PC-TOOL Software for adjusting and diagnostic
For MF/MP/LonWorks actuators and VAV Compact

UK24LON Gateway MP to LonWorks®, AC/DC 24V


LonMark ® certified Gateway according to
Functional Profile 8110, with transceiver FTT-10A
Connects MP/MFT(2) actuators or VAV Compact
units
Up to 8 actuators can be connected
UK24BAC Gateway MP to BACnet MS/TP, AC/DC 24V
Connects MP/MFT(2) actuators or VAV Compact
units
Up to 8 actuators and sensors can be connected
UK24MOD Gateway MP to Modbus RTU, AC/DC 24V
Connects MP/MFT(2) actuators or VAV Compact
units
Up to 8 actuators and sensors can be connected
ZIP-RS232 PC-MP Interface RS232/MP
Cable set

ZN230-24 24V plug-in power unit for MFT..


Input voltage: AC 230V
Output voltage: AC 24V/14VA
Use with ZIP-RS232
ZTH-GEN AP Setting and diagnostic device
with ZK1-GEN cable

ZIP-USB-MP PC-MP Interface USB/MP

ZK1-GEN 4-pin MP/PP connection cable


For ZIP-USB-MP to MF or MP
actuator/service socket

ZK2-GEN 3-pin MP/PP universal connection cable


For ZIP-USB-MP to terminal blocks

24
Fire and smoke protection, smoke extraction

Active safety with motorised Motorised Dampers using very powerful


Fire and Smoke Dampers Spring-Return Actuators

Ensuring the safety of human life and property in buildings is Belimo offers ranges of actuators for large and small Fire and
one of the toughest demands that planners, builders, owners Smoke Dampers. They satisfy the most stringent safety regu-
and operators are called upon to face. lations and their key features are: 4
In order to prevent the spread of fire and smoke through • A very robust housing
the HVAC ducting systems of buildings, motorised Fire and • Fire proof gearing to ensure safe positioning
Smoke Dampers are used to seal off individual zones should
• The heat-resistant spring guarantees at least 50,000 times
a fire occur. In contrast to conventional tripping mechanisms,
these dampers are actuated from a central point and are in- of safety closures
tegrated into safety systems such as those for fire and smoke • Thermoelectric triggering and/or by smoke detector (con-
detection. This means that they can offer extra protection tractor supplied) according to type
against the dangerous amount of low-temperature smoke • Suitable for inclusion in control and supervisory systems.
that is often produced before a fire actually breaks out. Fire
dampers operated by electric motors can also be monitored
very effectively, which reduces the high cost of manual func-
tional checks.

Typical applications
Main distribution Terminal control in individual rooms

Medium and large Fire Small Fire and Smoke


and Smoke Dampers in Dampers provide extra
walls and ceilings divide the sealing for individual
building into separate fire rooms housing valuable
Supply air zones. or sensitive computers,
telecommunications
equipment, etc.

Exhaust air

BF.. series BLF.. series

25
Fire and Smoke Spring-Return Actuators

FSLF.. US Fire and Smoke Spring-Return Actuators 3.5Nm

FSLF.. US Fire and Smoke Spring-Return Actuators 3.5Nm for Fire and Smoke Dampers,
95º angle of rotation, universal clamp for damper spindles 12.7…20mm
Meet requirement of UL555(S) when tested as an assembly with a suitable damper

Open/Close
3.5Nm
FSLF.. US FSLF24-S US FSLF24 US FSLF120-S US FSLF120 US FSLF230-S US FSLF230 US
AC 24V
AC 120V
AC 230V
Running time: motor <15s
spring return <15s
Integrated auxiliary switch fixed at 10º, 85º
Housing NEMA type1 (IP40)
Universal V-clamp
Ambient temperature 0...+50ºC
Position indication, mechanical, remote visible
Direction of rotation reversible by CCW/CW mounting
Conduit connector

FSNF.. US Fire and Smoke Spring-Return Actuators 7.9Nm

FSNF.. US Fire and Smoke Spring-Return Actuators 7.9Nm for Fire and Smoke Dampers,
95º angle of rotation, universal clamp for damper spindles 12.7…26mm
Meet requirement of UL555(S) when tested as an assembly with a suitable damper

Open/Close
7.9Nm
FSNF.. US FSNF24-S US FSNF24 US FSNF120-S US FSNF120 US FSNF230-S US FSNF230 US
AC 24V
AC 120V
AC 230V
Running time: motor <15s
spring return <15s
Integrated auxiliary switch fixed at 5º, 85º
Housing NEMA type1 (IP40)
Universal V-clamp
Ambient temperature 0...+50ºC
Position indication, mechanical, remote visible
Direction of rotation reversible by CCW/CW mounting
Conduit connector

26
Fire and Smoke Spring-Return Actuators

FSAF.. US Fire and Smoke Spring-Return Actuators 15Nm

FSAF.. US Fire and Smoke Spring-Return Actuators 15Nm for Fire and Smoke Dampers,
95º angle of rotation, universal clamp for damper spindles 12.7…26mm
Meet requirement of UL555(S) when tested as an assembly with the damper
4
Open/Close
15Nm
FSAF.. US FSAF24-S US FSAF24 US FSAF120-S US FSAF120 US FSAF230-S US FSAF230 US
AC 24V
AC 120V
AC 230V
Running time: motor <75s
spring return <20s
Integrated auxiliary switch fixed at 10º,
one adjustable 30...90º
Housing NEMA type1 (IP40)
Universal V-clamp
Ambient temperature -30...+50ºC
Position indication, mechanical, remote visible
Direction of rotation reversible by CCW/CW mounting
Conduit connector

27
Fire and Smoke Spring-Return Actuators

B..F.. series Fire and Smoke Spring-Return Actuators

Open/Close Modulating
Fire and Smoke Protection BLF24(-T)(-ST) BLF230(-T) BF24(-T)(-ST) BF230(-T) BFG24(-T)(-ST) BFG230(-T) BLF24-SR BF24-SR(-T)
Torque motor 6Nm (-SR type is 4Nm)
spring return 4Nm
Torque motor 11Nm
spring return 8.5Nm
Torque motor 18Nm
spring return 12Nm
AC 230V
AC/DC 24V
Running time: motor 40...75s (-SR type is 150s)
spring return 20s
Running time: motor 140s (-SR type is 150s)
spring return 16s
Running time: motor 140s
spring return 20s
Angle of rotation 90º
Angle of rotation 180º (angle of rotation of damper 90º)
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 0.5mA
Degree of protection: IP54
Spindle driver form-fit 10x10mm
Spindle driver form-fit 12x12mm
10x10mm with adapter supplied
2 SPDT auxiliary switches integrated fixed at 5º, 80º
2 SPDT auxiliary switches integrated fixed at 25º, 145º
(angles of rotation of damper 5º, 80º )
1 SPDT auxiliary switches integrated fixed at 5º
Ambient temperature -30...+50ºC
Halogen-free cable 1m, 0.75mm2
With plug connectors (-ST)

All actuators of 24V are also available with plug


connectors on the connecting leads suitable for
BKN230-24
Type combined (-T)

Available with thermoelectric tripping device

Available with external temperature fuse


Manual operation by crank

Explanation:

BF24(-T)(-ST) — we provide the products: BF24; BF24-T; BF24-ST; BF24-T-ST.


BF230(-T) — we provide the products: BF230; BF230-T.
BF24-SR(-T) — we provide the products: BF24-SR; BF24-SR-T.

28
Accessories

BLF.. BF.. BFG..


24V 230V 24V 230V 24V 230V
Fire and Smoke Protection
ZTPC600-B Thermal case
Protection of Operation in an environment of
300ºC for 1 hour or 600ºC for 30 minutes 4

BAE72 Response temperatures of thermal trips


Tf1: duct outside temperature 72ºC
Tf2: duct inside temperature 72ºC
Without test button

BAE72-F-ST Response temperatures of thermal trips


Tf1: duct outside temperature 72ºC
Tf2: duct inside temperature 72ºC
With plug for BSIA..

BAE72-S Response temperatures of thermal trips


Tf1: duct outside temperature 72ºC
Tf2: duct inside temperature 72ºC
With test button

BAE72-S-F-ST Response temperatures of thermal trips


Tf1: duct outside temperature 72ºC
Tf2: duct inside temperature 72ºC
With test button
With plug for BSIA..
ZBAE72 Spare thermoelectric tripping element
Tf2: duct inside temperature 72ºC
Black

ZBAE95 Spare thermoelectric tripping element


Tf2: duct inside temperature 95ºC
Green

S2A-F Auxiliary switch, add-on


2 SPDT 3A(0.5A), AC 250V

P200A-F Feedback potentiometer, add-on


200Ω

29
Fire and Smoke Protection, Smoke Extraction

Special Smoke Extraction systems save lives Fast and powerful: Actuators for Smoke Extrac-
tion Dampers
Past catastrophes involving fire have shown that it is the
smoke and fumes given off by the fire that are the greatest The damper is the key element of any Smoke Extraction sys-
danger to people trapped in buildings. Therefore, more and tem since its primary task is to move to a position that en-
more large and complex buildings such as shopping cen- sures safety — either open or closed depending on the type of
tres, hospitals, airports, etc. are being equipped with special system. When an emergency occurs, the dampers should be
Smoke Extraction systems. Such systems are able to remove brought to their safe position by means of a control signal and
very large quantities of smoke and poisonous fumes so that kept there. It is also important to be able to operate the damp-
escape routes for occupants and access paths for Fire and ers even when the smoke extraction system is already work-
Rescue Service remain clear. ing. In close co-operation with damper manufacturers, Belimo
has developed special Smoke Extraction Actuators.

The BE..series actuators with their high operating torque,


holding torque and fast running time ensure safe and reliable
operation of motorised Smoke Extraction dampers while also
satisfying the relevant European product and testing regula-
tions.

A typical Smoke Extraction system


A typical installation:
A ventilation system with fire dampers and
a separate Smoke Extraction system for
efficient removal of smoke.
The procedure in an emergency involving
the presence of smoke on Floor B (e.g.
tripping by fire detector):

a) Smoke Extraction system


• Smoke damper 2 is opened and the
poisonous fumes are extracted by
fan R.Smoke damper 1 is opened at
the same time, to replace with fresh
air from outside.
• Smoke damper 3, 4, 5 and 6 remain
closed
• The trapped occupants can escape
safely via the staircase.

b) Ventilation system
• Fire dampers 10 and 11 are closed
in order to seal off the fire and smoke
on Floor B from the remainder of the
ventilation system
• Fire dampers 9 and 13 are open. The
supply air fan produces a positive
pressure on Floors A and C to pre-
vent the penetration of smoke (+)
• Fire dampers 8 and 12 are closed.

30
Smoke Extraction Actuators

BLE../BR.. series Smoke Extraction Non-Spring-Return Actuators

Open/Close
Smoke Extraction BLE24 BLE24-ST BLE230 BR24-48-F-ST
Motor torque 15Nm
Holding torque - dynamic 15Nm
4
- steady-state 20Nm
Motor torque 15Nm
Holding torque - dynamic 15Nm
- steady-state 30Nm
AC 230V
AC/DC 24...48V
AC/DC 24V
Running time: <30s for 90º
Degree of protection: IP54
Spindle driver form-fit 12x12mm
2 SPDT Integrated auxiliary switch fixed at 3º, 87º
2 SPDT Integrated auxiliary switch fixed at 5º, 80º
Ambient temperature -30...+50ºC
Halogen-free cable 1m, 0.75mm2
C2 cable 1m, 0.75mm2
With plug connectors (-ST)
(all actuators of 24V are also available with plug connectors
on the connecting leads suitable for BKN230-24)
With the control unit for pulse triggering BSIA24-48 (-R)
Manual operation by hex crank

BE.. series Smoke Extraction Non-Spring-Return Actuators

Open/Close
Smoke Extraction BE24(-12) BE24(-12)-ST BE230(-12)
Motor torque 40Nm
Holding torque - dynamic 40Nm
- steady-state 50Nm
AC 230V
AC/DC 24V
Running time: <60s for 90º
Degree of protection: IP54
Spindle driver form-fit 12x12mm [(-12) type],
BE24(-ST) and BE230 form-fit 14x14mm
2 SPDT Integrated auxiliary switch fixed at 3º, 87º
Ambient temperature -30...+50ºC
Halogen-free cable 1m, 0.75mm2
With plug connectors (-ST)
(all actuators of 24V are also available with plug connectors
on the connecting leads suitable for BKN230-24)
Manual operation by hex crank

31
Comfort made easy
Complete solutions in VAV and CAV
HVAC variable air volume control

System structure

Workstation

Fan Control
Water/Electric
Reheater

Room Controller Room Controller

VAV Compact Fan Powered VAV box


Room Unit
VAV Compact Single/dual duct VAV

Room Unit

Belimo PC-Tool VAV Compact Single/dual duct VAV Max. 2 VAV boxes in parallel

Fan Optimiser
DDC with Total max.8
DDC
Other Fan Optimisers VAV Compact VAV Compact

Frequency Converter Setpoint Signal Setpoint Signal

Fan

Room Temperature Controller Room Temperature Controller

Advantages:
• Controller with I/O functions Room Controller Belimo Room Control Module T24-V42(-V02)LON, T24-V42(-V02)BAC
• Electric heaters output Room Unit Belimo T24-MP
• 3-point or modulating reheat VAV Compact Belimo LMV-D3-MP, LMV-D3-MFT-RM, NMV-D3-MP, LMV-D3LON,
• Parallel or series fan output NMV-D3LON
• Economy/override mode selection Box Belimo single/dual duct, fan powered, CAV
• NTC type temperature sensor input Certification LonMark®, BTL
• Communication (LonWorks/BACnet) interface Belimo MP-Bus communication
• Pre-store room control applications LonWorks/BACnet communication
• Total solution for VAV

For more detailed information please contact your Belimo sales representative.
33
VAV Compact

LMV-D3…VAV Compact 5Nm, a differential pressure sensor, digital VAV controller


and damper actuator all in one, providing a full solution with a communication
capability for pressure-independent VAV and CAV systems in the comfort zone

Compact Actuators 5Nm LMV-D3-MFT-RM LMV-D3-MP LMV-D3LON


AC 24V, 50/60Hz
DC 24V
Differential pressure sensor 0...600Pa 5
Vnom specific nominal volumetric flow setting, matches VAV box
Vmax 20...100% of Vnom
Vmin 0...100% of Vnom
PP/MP-Bus, max. DC 15V, 1200 baud
LonWorks®
Sensor integration
Button, adaption/addressing/service function
LED indicator, 24V feed status/service/bus function
Direction of rotation, CCW/CW
Adaptation, setting range recording and resolution to control range
Manual disengagement, push button, self-resetting without affecting functions
Angle of rotation 95º , with adjustable mechanical or electronic limiting
Position indication, mechanical with pointer
Connection cable, 4x0.75mm2, terminals
Connection cable, 6x0.75mm2, terminals
Protection class III, safety extra-low voltage
Degree of protection: IP54

NMV-D3…VAV Compact 10Nm, a differential pressure sensor, digital VAV controller


and damper actuator all in one, providing a full solution with a communication
capability for pressure-independent VAV and CAV systems in the comfort zone

Compact Actuators 10Nm NMV-D3-MP NMV-D3LON


AC 24V, 50/60Hz
DC 24V
Differential pressure sensor 0...600Pa
Vnom specific nominal volumetric flow setting, matches VAV box
Vmax 20...100% of Vnom
Vmin 0...100% of Vnom
PP/MP-Bus, max. DC 15V, 1200 baud
LonWorks®
Button, adaption/addressing/service function
LED indicator, 24V feed status/service/bus function
Direction of rotation, CCW/CW
Adaptation, setting range recording and resolution to control range
Manual disengagement, push button, self-resetting without affecting functions
Angle of rotation 95º , with adjustable mechanical or electronic limiting
Position indication, mechanical with pointer
Connection cable, 4x0.75mm2, terminals
Connection cable, 6x0.75mm2, terminals
Protection class III, safety extra-low voltage
Degree of protection: IP54

34
VAV and Room Control Module

Room Control Module

T24-V42LON T24-V02LON T24-V42BAC T24-V02BAC


Nominal voltage AC 24V 50/60Hz
Input / output control Analog input x 1
Digital input x 1
Analog output x 1 (DC 2...10V) 5
Digital output x 3 (AC 24V)
Pre-stored applications Room control applications 17 2 17 2
Fan Series or parallel fan
Communication system Built-in LonWorks® and Belimo MP-Bus
Built-in BACnet® and Belimo MP-Bus
Algorithm PI control algorithm
Mode selections Normal / economy / standby
LED indications Power, communication status
Digital outputs
Degree of protection IP20

Room Unit Room Sensor

T24-MP TG-R10000
Nominal voltage AC 24V 50/60Hz
Sensing element Built-in NTC type sensor
LCD display Blue backlight
Built-in diagnostic socket RJ12
Temperature display Room temperature/setpoint selection
Degree of protection IP30

35
Seamless Link
Belimo new optimised Characterised Control Valves —— a better connection

36
Rotary Actuators and Valves

For variable control and Open/Close applications


The Characterised Control Valves are available in 2-way and 3-way versions in nominal sizes from DN15 to DN150 with different
Kvs values. There are also conventional Ball Valves available for Open/Close applications. All valves are supplied together with
the appropriate Rotary Actuator—they can be ordered pre-fitted or as separate items.

Co-ordinated motorised operation


Optimum functionality of Belimo Characterised Control Valves is assured by the provision of properly coordinated motorised
operation. The specially developed Rotary Actuators which provide the necessary precision in voltages, modulating, 3-point or
Open/Close methods of control, are available depending on which type of actuator is used.

SS VALVE

Stainless Steel CCV


To be released in mid 2014

37
Rotary Actuators and Valves

Belimo solutions for water The Characterised Control Valve Rotary Actuators for water
control devices is a full function control device control devices

Belimo offers cost effective solutions Belimo has once again demonstrated its Reliable operation of the valves is en-
of high standard and quality for water innovative spirit, this time in the field of wa- sured through the use of suitable Rotary
control applications. Consultants, man- ter flow control. The specially developed Actuators. Depending on the type of
ufacturers and installers benefit from a characterising disc gives the Character- valve and the application, the choice is
range of advantages: ised Control Valve excellent characteris- from the following families of actuators:
tics:
• Simplified planning with a consistent • The R.. range General Rotary Actua-
series of products for air and water • Equal percentage flow characteristics tor: TR-2Nm, LRU-5Nm, NRU-10Nm,
applications • No sudden jump in flow when the valve SRVU-20Nm, GRVU-40Nm
• Purchase of HVAC actuators from a opens • The F.. range Fail-Safe Actuators:
single source (i.e one-stop shopping) • Kvs values comparable with those of lift- TRF-2Nm, LRF-4Nm, NRFU-10Nm,
• Easy incorporation of all actuators type Globe Valves of identical nominal SRFU-20Nm
into a total system thanks to compat- size • All actuators except TRF have manual
ible actuator technology • High close off pressure override facility. Actuators are prefitted,
• Lower installation costs thanks to use • Fewer pipe reducers needed have a 1m lead, clear position indica-
of similar methods for all actuators. • Better part-load characteristics. tion and come in a variety of voltages
and control signals.

Belimo Characterised Control Valves:


Equal-percentage valve characteristic thanks to the new characterising disc
In order to ensure good stability of control, the final controlling element must have an equal-percentage valve characteristic. This
will give a linear relationship between the thermal output and the amount of valve opening.

In the past, this has only been possible by using lift-type Globe Valves: under normal circumstances Ball Valves have an S-shaped
characteristic which, however, is considerably deformed in actual use because of the extremely high flow characteristic (Kvs)
compared with the nominal size.

By developing a special characterising disc, Belimo has succeeded in solving this problem.

The side of the characterising disc that faces the ball is concave and rests on the surface of the ball. The flow is regulated as it
passes through the hole in the ball and a V-shaped slot in the characterising disc. This reduces the Kvs value to value comparable
with that of a lift-type Globe Valve of the same nominal size. It guarantees an equal-percentage valve characteristic.

Belimo Control Valve


with the new characterising disc
Characteristic curve of a Belimo Control Valve

38
How to order Characterised Control Valves

Valve Actuator types Assembling


The range contains two types of Ball For motorising Characterised Control A successful order will need the following
Valves: Characterised Control and Open/ Valves (CCV), there are seven rating information:
Close. Both types are available as 2-way classes of actuators available that are
and 3-way in nominal sizes from DN15 suitable for different power supplies and
to DN150. methods of control.

For more technical information see the databook

1 Valve • 2-way stainless steel Characterised Control Valves 6


• 2-way stainless steel Open/Close Ball Valves
• 2-way and 3-way Characterised Control Valves
• 2-way and 3-way Open/Close Ball Valves

2-way 3-way

2 Assembling The valves and actuators can be supplied as follows:


• With actuator fitted (+)
• Valve and actuator separately (/)
• Supplied separately at different times (on request)
Actuator fitted Separately

3 Actuator types The following data must be provided:


• Open/Close, 3-point or modulating
• Nominal voltage AC/DC 24V, AC 230V
TR LR NR SRVU..-5 GRVU..-7 • With fail-safe, NC (Normally closed) or
NO (Normally open)

TRF L(R)F NRFU SRFU..-5

4 Pipe connections The valves are available as low-cost fittings with internal threads.
separately (option) • As an option, types R2..AC/R3..AC are available with indi-
vidual pipe connectors supplied separately (/Z)

Separately

Ordering example Designation: R322AC+LRU24/Z

Valve type:
Design 3-way Characterised Control Valve
Size Internal thread 1” BSP, DN25
Flow coefficieny Kvs 6.3
Assembling: Actuator fitted
Actuator:
Nominal voltage Rotary Actuator, AC 24V
Control Open/Close or 3-point
Running time 90s
Pipe connectors (option): 3 X ZR2325 separately

39
Characterised Control Valves

Modulating/3-point Open/Close
R2..AH R2..AC R3..AC R6..AO R2..AH R2..AC R3..AC R6..AO

Type
Nominal size DN[mm] 15...50
DN[mm] 65...150
Design 2-way
3-way: Through-flow A-AB, Bypass B-AB
Characteristic curve Equal-percentage
Applications Cold water and hot water systems
Water temperature -5...+100ºC
Materials Body: stainless steel 316
Body: nickel-plated brass
Body: GG25 polyester coated
Ball and spindle: stainless steel
Ball and spindle: stainless steel 316
Connections Internal thread BSP (ISO 7/1)
Flanged (ISO 7005-2)
Rated pressure PN41 (DN15...25)
PN27 (DN32...50)
PN25 (DN15...50)
PN16 (DN65...150)
Closing pressure 1400kPa
700kPa (DN65...125)
300kPa (DN150)

kv Flow characteristics of Characterised Control Valves Rated pressure: 3-way, 4140kPa (DN15...25), 2760kPa (DN32...50)
Characteristic: equal percentage 2-way, 2500kPa (DN15...50), 1600kPa (DN65...150)
Y

Connection Internal thread Flange PN16


Kvs[m /h]
3
0.63 1.0 1.6 2.5 4.0 4.0 6.3 6.3 10.0 10.0 16.0 16.0 25.0 25.0 40.0 63 100 140 230 320

DN[mm] 15 15 15 15 15 20 20 25 25 32 32 40 40 50 50 65 80 100 125 150


R209AC R210AC R211AC R212AC R213AC R217AC R218AC R222AC R223AC R229AC R231AC R238AC R239AC R248AC R249AC R664AO R679AO R6099AO R6124AO R6149AO
2-way
R209AH R210AH R211AH R212AH R213AH R217AH R218AH R222AH R223AH R229AH R231AH R238AH R239AH R248AH R249AH

Connection Internal thread


Kvs[m3/h] 0.25 0.4 0.63 1.0 1.6 2.5 4.0 4.0 6.3 6.3 10.0 10.0 16.0 16.0 25.0
DN[mm] 15 15 15 15 15 15 15 20 20 25 25 32 32 40 50

3-way R305AC R306AC R309AC R310AC R311AC R312AC R313AC R317AC R318AC R322AC R323AC R329AC R331AC R338AC R348AC

kv Flow characteristics of Open/Close Ball Valves Rated pressure: 3-way, 4140kPa (DN15...25), 2760kPa (DN32...50)
2-way, 2500kPa (DN15...50), 1600kPa
(DN65...150)
Y

Connection Internal thread Flange PN16


Kvs[m /h]
3 8.6 13 18 31 40 65 120 180 230 390 570

DN[mm] 15 20 25 32 40 50 65 80 100 125 150

R215AC R220AC R225AC R232AC R240AC R250AC R665AO R680AO R6100AO R6125AO R6150AO
2-way
R215AH R220AH R225AH R232AH R240AH R250AH - - - - -

Connection Internal thread


Kvs[m3/h] 15 32 26 18 32 31 49

DN[mm] 15 20 25 32 32 40 50

3-way R315AC R320AC R325AC R330AC R332AC R340AC R350AC

40
Open/Close or 3-point Rotary Actuators

General Rotary Actuator


Open/Close or 3-point Open/Close
TR24 TR230-3 LRU24(-S) LRU230(-S) NRU24(-S) NRU230(-S) SRVU24(-S)-5 SRVU230(-S)-5 GRVU24-7 GRVU230-7

Type
AC 230V
AC 100...240V
AC/DC 24V
Motor torque (Nm) 2 2 5 5 10 10 20 20 40 40
Running time: 90...105s 6
90s
150s
Only 2-wire control
Single-wire control or 2-wire control
Auxiliary switch model available “-S”
Manual operation

Fail-Safe Rotary Actuator


Open/Close
TRF24(-S) TRF230(-S) LRF24(-S) LRF230(-S) NRFU(-S2) SRFU(-S2)-5 GRKS*1

Type
AC 230V
AC 100...240V
AC/DC 24V
AC/DC 24...230V
Motor torque (Nm) 2 2 4 4 10 20 40
Running time: motor 45...75s, spring return 20s
motor 45...75s, spring return 75s
motor 150s, emergency setting 35s
Auxiliary switch model available “-S”
“-S2*”
Linkage included
Manual operation

* 2 X aux. switches available


*1 Customising for GRKS..

Mechanical Fail-Safe Rotary Actuator


3-point
TRF24-2 LF24-3* 3 NRFS* 2 SRFS* 2

Type
AC/DC 24V
Motor torque (Nm) 2 4 10 20
Running time: motor 90s, spring return 25s
motor 45...75s, spring return 20s
motor 150s, spring return 20s
Auxiliary switch model available “-S”

*2 Customising for NRFS/SRFS types


*3 Linkage kit WLF required for LF.. actuators

41
Modulating Rotary Actuators

General Rotary Actuator


Modulating
TR24-SR LRU24-SR NRU24-SR SRVU24-SR-5 GRVU24-SR-7

Type
AC/DC 24V
Motor torque (Nm) 2 5 10 20 40
Running time: 90s
150s
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V

Fail-Safe Rotary Actuator


Modulating
TRF24-SR LRF24-SR NRFU24-SR SRFU24-SR-5 GRKS*

Type
AC/DC 24V
Motor torque (Nm) 2 4 10 20 40
Running time: 90s
150s
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V
Linkage included
Auxiliary switch model available “-S”
* Customising for GRKS..
(When ordering the actuator individually, NO or NC must be provided for fail-safe type actuators.)

42
Open/Close Ball Valves

General Rotary Actuator Fail-Safe Rotary Actuator


TR LRU NRU SRVU GRVU TRF L(R)F NRFU SRFU-5 GRKS

2-way
R2..AH(SS316)
Kvs Close-off
DN[mm] BSP Type
[m3/h] Pressure
15 1/2” R215AH 8.6 1400kPa
20 3/4” R220AH 13 1400kPa
25 1” R225AH 18 1400kPa 6
32 1 1/4” R232AH 31 1400kPa
40 1 1/2” R240AH 40 1400kPa
50 2” R250AH 65 1400kPa

2-way

R2..AC/R6..AO
Kvs Close-off
DN[mm] BSP Type
[m3/h] Pressure
15 1/2” R215AC 8.6 1400kPa
20 3/4” R220AC 13 1400kPa
25 1” R225AC 18 1400kPa
32 1 1/4” R232AC 31 1400kPa
40 1 1/2” R240AC 40 1400kPa
50 2” R250AC 65 1400kPa
65 2 1/2” R665AO 120 700kPa
80 3” R680AO 180 700kPa
100 4” R6100AO 230 700kPa
125 5” R6125AO 390 700kPa
150 6” R6150AO 570 400kPa

3-way
R3..AC
Kvs A-AB Close-off
DN[mm] BSP Type
[m3/h] Pressure
15 1/2” R315AC 8.6 1400kPa
20 3/4” R320AC 21 1400kPa
25 1” R325AC 26 1400kPa
32 1 1/4” R330AC 16 1400kPa
32 1 1/4” R332AC 32 1400kPa
40 1 1/2” R340AC 32 1400kPa
50 2” R350AC 49 1400kPa
The kvs value B-AB is 70% of A-AB.

Pipe connectors for Characterised Control Valves as accessories


DN[mm] R/BSP Type
15 1/2” ZR2315
20 3/4” ZR2320
25 1” ZR2325
32 1 1/4” ZR2332
40 1 1/2” ZR2340
50 2” ZR2350

43
Characterised Control Valves

General Rotary Actuator Fail-Safe Rotary Actuator


TR LRU NRU SRVU GRVU TRF LRF NRFU SRFU-5 GRKS

2-way
R2..AH(SS316)
Kvs Close-off
DN[mm] BSP Type
[m3/h] Pressure
15 1/2” R209AH 0.63 1400kPa
15 1/2” R210AH 1.0 1400kPa
15 1/2” R211AH 1.6 1400kPa
15 1/2” R212AH 2.5 1400kPa
15 1/2” R213AH 4.0 1400kPa
20 3/4” R217AH 4.0 1400kPa
20 3/4” R218AH 6.3 1400kPa
25 1” R222AH 6.3 1400kPa
25 1” R223AH 10 1400kPa
32 1 1/4” R229AH 10 1400kPa
32 1 1/4” R231AH 16 1400kPa
40 1 1/2” R238AH 16 1400kPa
40 1 1/2” R239AH 25 1400kPa
50 2” R248AH 25 1400kPa
50 2” R249AH 40 1400kPa

2-way
R2..AC/R6..AO
Kvs Close-off
DN[mm] BSP Type
[m3/h] Pressure
15 1/2” R209AC 0.63 1400kPa
15 1/2” R210AC 1.0 1400kPa
15 1/2” R211AC 1.6 1400kPa
15 1/2” R212AC 2.5 1400kPa
15 1/2” R213AC 4.0 1400kPa
20 3/4” R217AC 4.0 1400kPa
20 3/4” R218AC 6.3 1400kPa
25 1” R222AC 6.3 1400kPa
25 1” R223AC 10 1400kPa
32 1 1/4” R229AC 10 1400kPa
32 1 1/4” R231AC 16 1400kPa
40 1 1/2” R238AC 16 1400kPa
40 1 1/2” R239AC 25 1400kPa
50 2” R248AC 25 1400kPa
50 2” R249AC 40 1400kPa
65 2 1/2” R664AO 63 700kPa
80 3” R679AO 100 700kPa
100 4” R6099AO 140 700kPa
125 5” R6124AO 230 700kPa
150 6” R6149AO 320 400kPa

44
Characterised Control Valves

General Rotary Actuator Fail-Safe Rotary Actuator


TR LRU NRU SRVU GRVU TRF LRF NRFU SRFU-5 GRKS

3-way
R3..AC
Kvs A-AB Close-off
DN[mm] BSP Type
[m3/h] Pressure
6
15 1/2” R305AC 0.25 1400kPa
15 1/2” R306AC 0.4 1400kPa
15 1/2” R309AC 0.63 1400kPa
15 1/2” R310AC 1.0 1400kPa
15 1/2” R311AC 1.6 1400kPa
15 1/2” R312AC 2.5 1400kPa
15 1/2” R313AC 4.0 1400kPa
20 3/4” R317AC 4.0 1400kPa
20 3/4” R318AC 6.3 1400kPa
25 1” R322AC 6.3 1400kPa
25 1” R323AC 10 1400kPa
32 1 1/4” R329AC 10 1400kPa
32 1 1/4” R331AC 16 1400kPa
40 1 1/2” R338AC 16 1400kPa
50 2” R348AC 25 1400kPa
The Kvs value B-AB is 70% of A-AB.

45
Fast-Running Actuators and RobustLine CCV Actuators

LRQU../NRQU../SRQU..* Fast-Running Actuators 4Nm/8Nm/16Nm

Open/Close Modulating
Damper Actuators LRQU24 NRQU24 SRQS24* LRQU24-SR NRQU24-SR SRQS24-SR*
Torque 4Nm
8Nm
16Nm
AC/DC 24V
Running time 5s/90º
7s/90º
Open/Close
Control signal Y DC (0)2...10V
Feedback signal U DC 2...10V, max. 0.5mA
Degree of protection: IP54
Sound power level max. 52dB(A)
Ambient temperature -30...+40ºC
Cable 1m, 0.75mm2
Position indication, mechanical, remote visible

* SRQS.. by request, not yet available.

RobustLine CCV Actuators

SR..PX..series RobustLine IP66+IP67 CCV Actuators

IP66+IP67/NEMA4
Torque: 18Nm
For hazardous environment applications
UV protected

46
Steam Valves

The introduction of Belimo’s innovative Control Ball Valve in 1999 has helped Belimo to achieve the market leader position in both
Valves and Damper Actuators in HVAC. With many years of development, research and great success in the Control Ball Valve
market, we become expert in Control Ball Valve manufacturing today. To further strengthen our market position, we are proud to
announce the expansion of the CCV range for steam applications.

S VALVE

47
Steam Valves

Technical data
Flow medium Cold water, hot water and steam
Temperature of medium 0...175ºC
Rated pressure Ps 1600kPa
Flow characteristic Equal percentage
Leakage rate 0...0.01%Kvs value (Max. 0.06%Kvs for DN15)
Pipe connector ISO 7005-2
Closing pressure ps DN15/25/40/50/65 1000kPa
DN80 700kPa
Angle of rotation 90º
Materials
Body Grey cast iron
Seat Heat-resistant PTFE
Stem Stainless steel
Gland packing Inorganic fibre
Gasket Non-asbestos joint sheet

Valve sizing table


Flow characteristics of Characterised Control Valves Rated pressure: 1600kPa
(DN15/25/40/50/65/80)
Characteristic: equal percentage

Connection Flange PN16


Kvs [m3/h] 0.86 1.4 2.2 3.5 5.2 8.6 13.8 21.6 34.5 56.0 81.9 108.0

DN [mm] 15 15 15 15 15 25 25 40 40 50 65 80

2-way R610AS R611AS R612AS R613AS R614AS R623AS R624AS R638AS R639AS R649AS R664AS R679AS

Actuators LFH.. SRFU..

Features

• An equal-percentage flow characteristic


• Compact and lightweight
• DN15/25/40/50/65/80
• Medium temperature range: 0...175ºC
• High close-off pressure
• PN16 flange connections (ISO 7005-2)
• Long life cycles
• Modulating, Open/Close control types are available
• Actuator with spring-return function (fail-safe function)
• Manual operation
• Optional adjustable auxiliary switch
• Low power consumption
• Highly engineered and tested

48
Pressure Independent Characterised Control Valves

Belimo has introduced a new range of innovative products for HVAC water applications. After years of research and thorough
tests, Belimo is proud to introduce the EPIV and PICCV range to the global market, which will bring enormous benefits to our
customers.

Smart, precise, independent


• A 2-way valve that will supply a specific constant flow for each degree of ball opening regardless of pressure variations in the
system.
• Eliminates the need for balancing valve and balancing procedure, reverse-return or oversized main piping, resulting in lower
capital and installation cost.
• Reduces design and analysis costs of valve sizing.
• Provides more accurate and stable control, especially at low load, resulting in greater occupancy comfort level, longer equip-
ment life and lower running costs.
• Features equal-percentage flow characteristics, higher body pressure.
• Accurate actual flow feedback is constantly provided.
• Smaller pipes can sometimes be used because the effect of pipe losses on pressure variations can be accepted.
• With MF functionality, flow limits, signal type, running time and various actuator parameters can be set.
• Covered by Belimo 5 year warranty.

EPIV
offers many advantages...

49
Pressure Independent Characterised Control Valves

Technical data PICCV-..

Nominal size [mm] DN15...50


Design 2-way
Flow characteristic Equal-percentage
Areas of application Cold water and hot water, with 50% volume of glycol
Temperature of medium -5...+100ºC
Material Body forged nickel-plated brass
Ball and spindle chrome-plated brass
Pipe connections Internal thread acc. to ISO 7/1
Rate pressure 4140kPa (DN15...25), 2760kPa (DN32...50)
Closing pressure 1400kPa (actuator still capable of closing valve, leakage rate exceeds 0.01% maximum flow)
350kPa (leakage rate 0.01% maximum flow)
Differential pressure 35...350kPa
Flow range 0.04...5.5l/s

Valve sizing table


Type DN [l/s] [m3/h] Flow range** Actuator
The flow is unaffected by pressure changes
[mm] Default [l/s]
—the simplest way to control the flow rate
PICCV-15-006 15 0.06 0.22
0.04...0.10 Pressure balancing Control Valve
PICCV-15-009 15 0.09 0.32 Control Valve

PICCV-15-013 15 0.13 0.47


PICCV-15-019 15 0.19 0.68
0.10...0.40
PICCV-15-032 15 0.32 1.15
PICCV-15-036 15 0.36 1.30
PICCV-20-037 20 0.37 1.33
LRU24-MF*
PICCV-20-044 20 0.44 1.58
0.27...0.66
PICCV-20-057 20 0.57 2.05
PICCV-20-066 20 0.66 2.38 Flow direction
(Actuator not shown)
PICCV-25-069 25 0.69 2.48
PICCV-25-088 25 0.88 3.17
0.50...1.10 Flow diagram of PICCV-20-066
PICCV-25-098 25 0.98 3.53
PICCV-25-102 25 1.02 3.67
PICCV-32-099 32 0.99 3.56
PICCV-32-112 32 1.12 4.03
PICCV-32-127 32 1.27 4.57 0.72...1.60
PICCV-32-151 32 1.51 5.44
PICCV-32-156 32 1.56 5.62 NRU24-MF*
PICCV-40-190 40 1.90 6.84 Differential pressure (effective pressure)
0.99...2.20
PICCV-40-208 40 2.08 7.74
PICCV-50-235 50 2.35 8.46 Only one valve is needed per consumer:
1.22...2.70
PICCV-50-255 50 2.55 9.18 previously now

PICCV-50-300 50 3.00 10.80


PICCV-50-350 50 3.50 12.60
2.48...5.50 SRU24-MF*
PICCV-50-420 50 4.20 15.12
PICCV-50-506 50 5.06 18.22

* For more details of the actuator, please refer to Pressure Independent


Characterised Control Valves databook.
**Flow setting is depending on combination of actuators (angle). For detail,
please refer to PICCV flow limitation at our website www.belimo.ch.

50
Electronic Pressure Independent Valves

Technical data EPIV

Nominal size [mm] DN65...150


Design 2-way
Flow characteristic Equal-percentage (according to VDI/VDE 2178)
Areas of application Cold water and hot water, with 50% volume of glycol in closed system
Temperature of medium -5...+120ºC (without spindle heater)
-10...+120ºC (with spindle heater)
Material Valve body Cast iron - GG25 and ductile iron - GGG50
Ball Stainless steel 6
Characterising disc Stainless steel
Connections Flange ISO 7005-2
Rated pressure 1600kPa

Type DN[mm] [l/s] [m3/h] Type


EPIV-65-800 65 8.00 28.80 SRU24-PI-65
EPIV-80-1140 80 11.33 40.80 SRU24-PI-80
EPIV-100-2000 100 20.00 72.00 GRU24-PI-100
EPIV-125-3125 125 31.25 112.50 GRU24-PI-125
EPIV-150-4500 150 45.00 162.00 GRU24-PI-150
*Optional 60Hz and Electronic Fail-Safe actuators are available for EPIV.

51
EPIV

Technical Data

Mode of operation
The Electronic Pressure Independent Valve, EPIV, consists of an Electromagnetic flow sensing
element, a Characterised Control Ball Valve, and a modulating type Rotary Actuator with MP
Bus technology.

The Control Valve is motorised by the actuator according to the input signal, while fine tuning
is based on the comparison between the actual and the requested flow by the flow-sensing
electronic. As a result, constant flow is achieved independent of system pressure changes
or other tolerances.

Product features
Equal-percentage characteristic Equal-percentage characteristic of the flow ensured by the integrated characterising disk, and
algorithm inside actuator.

.
Constant flow volume V Constant flow volume V with various differential pressure up to 340kPa, thanks to the electronic
flow sensor. A valve authority of  is attained, regardless of differential pressure variations
across the valve.

Even in the part-load range, the flow rate remains constant, and the valve compensates the
extra differential pressure.

Manual operation by lever Manual operation by lever after disengaging the gearing latch on the SRU.. Rotary Actuator.

52
Communication-capable Rotary Actuator for EPIV system

Modulating
SRU24-PI-65 SRU24-PI-80
Type

AC/DC 24V
Motor torque (Nm) 20 20
Control signal Y DC (0)2...10V
Feedback signal U DC (0)2...10V
Manual operation
Full valve size DN65 DN80 6

Modulating
GRU24-PI-100 GRU24-PI-125 GRU24-PI-150
Type

AC/DC 24V
Motor torque (Nm) 40 40 40
Control signal Y DC (0)2...10V
Feedback signal U DC (0)2...10V
Manual operation
Full valve size DN100 DN125 DN150

53
Energy Valves

The Energy Valve not only keeps owners and/or operators informed of coil performance, it has built-in Belimo Delta T Manager
that helps operators analyse and fine tune performance under any and all conditions.

Once these problems are eliminated, the opportunities for system wide optimisation open up. At that point, owners, engineers,
and contractors realise a host of benefits enables through the Belimo Energy Valve.

One solution, so many benefits!


Energy Monitoring. New Energy Valve can provide Delta T, Flow and Energy information with no difficulties. All data can be sent
to BMS through BACnet IP or MS/TP, making energy monitoring an easy job from now on.
• Combat Low Delta T. The risk of Low Delta T (the most common culprit of major system inefficiencies) is dramatically reduced
or eliminated.
• Enhanced Energy Optimisation. Owners capitalise on optimisation strategies such as variable flow pumping without risking
occupant comfort.
• Improved Commissioning. Start-up commissioning as well as re-commissioning is greatly simplified.
• Better System Maintenance. Operators are much more informed about coil performance and thus better able to schedule
preventive maintenance.
• More Effective Control. Engineers are able to implement more advanced control strategies by taking advantage of the data
logging provided at individual coils.
• Smaller Equipment. Buildings are able to meet comfort demand with smaller, less expensive piping and equipment.

Energy Valve
Knowledge is power TM

http://www.

54
Energy Valves

Technical data EV

Nominal size [mm] DN65...150


Design 2-way
Flow characteristic Equal-percentage (according to VDI/VDE 2178)
Areas of application Cold water and hot water, with 50% volume of glycol in closed system
Temperature of medium -5...+120ºC (without spindle heater)
-10...+120ºC (with spindle heater)
Material Valve body Cast iron - GG25
Ball Stainless steel 6
Characterising disc Stainless steel
Connections Flange ISO 7005-2
Rated pressure 1600kPa

Matching table

Type DN[mm] [l/s] Tempt. Sensor Type


EV-65-800 65 8.00 PT1000 SRU24LP-65
EV-80-1100 80 11.00 PT1000 SRU24LP-80
EV-100-2000 100 20.00 PT1000 GRU24LP-100
EV-125-3125 125 31.25 PT1000 GRU24LP-125
EV-150-4500 150 45.00 PT1000 GRU24LP-150

Monitoring and adjustment

In addition, the Belimo Delta T Manager continuously monitors the coil Delta T compares this value with the desired Delta T value or setpoint. For
example in a cooling application, if the actual Delta T is below the setpoint, the valve will readjust flow to bring Delta T back to the desired setpoint.
Once the appropriate Delta T is re-established, the valve control resumes it is normal operating mode taking its signal from the DDC controller.
The software monitors and can trend all sensed or calculated values for up to 13 months. These values include water flow, return and supply water
temperature, power, energy, or media density and more.

55
The reliable opening and closing valves
Quality range of Belimo Butterfly Valves

56
Rotary Actuators and Butterfly Valves

Applications
Belimo has developed a wide range of Butterfly Valves and Actuators meeting all specific and stringent demands of HVAC ap-
plications requiring positive shut off and control for all kinds of flow media, with enormous efforts and continual innovation. Typical
applications include chiller isolations, cooling tower isolations, large air handling units, boilers, change-over systems, water and
ice storage systems and bypass control applications.

Features and benefits


• Double-D fit of stem connecting with the disc, gives a stronger and more compact structure. It can produce self-adjusting centring
due to rotary movement, thanks to a unique design. It can also optimise and minimise interference-fit, resulting in low operation
torque.
• Innovative double supports of trench seat without back can ensure positive assembly among valve body, valve seat and disc and
can keep rotation of disc consistently running smoothly, minimising compressional deformation and seat brushing off.
• Advanced ball profile of disc with narrow sealing belt can provide complete isolation of HVAC flow media from valve body by
double-prevention and can eliminate internal leakage and reduce seat tearing or fatiguing due to bunching. The primary seal is
achieved by an interference-fit of the molded seat flat with the disc hub. The secondary seal is created when the stem diameter
is greater than the internal stem hole.
• The nylon coated disc features excellent anti-corrosion and low friction coefficient with exact casting, precision machining and
advanced coated process which give a smooth rotation and close disc-to-seat relationship. The stainless steel disc is rust proof
due to the hand polishing process which can decrease operation torque for the actuator and withstand higher HVAC flow media
temperature.
• Three anti-corrosion RPTFE bushings (made of Reinforced PolyTetraFluoroEthylene), EPDM O ring (made of Ethylene Propyl
ene Diene Monomer) and stainless steel stem circlip completely isolate flow media from top flange, synchronise rotation between
stem and disc, decrease operation torque and ensure extreme long life cycle.
• Meet stringent and extensive HVAC flow media variations with wide and circular arc flange sealing surface. This can be suitable
for all flange connection standards as ISO, JIS, AS without additional gasket in Asia Pacific.
• Belimo offers numerous advanced motorised actuators, along with high quality manual handle or worm gear drives, ensuring a
highly reliable performance and value added Butterfly Valve combination solution is provided.

57
Stand Motorised Butterfly Valves BU6..

Technical Data BU6..L..(S) BU6..(S)

Nominal size DN [mm] DN50...500


Nominal pressure 1600kPa
Max. close-off pressure 1200kPa
Flow media Nylon coated disc Cold water and hot water
SS304 disc Cold water and hot water, Max. 50% glycol
Temperature of medium Nylon coated disc 0...+95ºC
SS304 disc -20...+100ºC
Material
Body Ductile cast iron GGG40 (DN50...500)
Disc Nylon coated ductile cast iron disc / stainless steel 304 disc (S)
Seat EPDM
Stem Stainless steel 416
Bushing RPTFE
Connections For pipe flange: ISO 7005.2, AS 2129 PN10/16 and Table E for wafer (DN50...300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
For actuator: ISO 5211

Rotary Actuators (IP54)


General Rotary Actuator
Type SRVU SRVU SRVU SRVU SRVU GRVU GRVU GRVU DGRVU DGRVU DGRVU
24-5 24-S-5 230-5 230-S-5 24-SR-5 24-5/7 230-5/7 24-SR-5/7 24 230 24-SR
(20Nm) (20Nm) (20Nm) (20Nm) (20Nm) (40Nm) (40Nm) (40Nm) (72Nm) (72Nm) (72Nm)
Voltage
AC/DC 24V
AC 100...240V
Control signal
Open/Close or 3-point
Modulating
Integral, potential-free auxiliary
switch 0...100% adjustable
Mechanical/ Electronic Fail-Safe Rotary Actuator
Type SRFU-5 SRFU-S2-5 SRFU24-SR-5 GRKU..-7
(20Nm) (20Nm) (20Nm) (40Nm)
Voltage
AC/DC 24V
Control signal
Open/Close or 3-point
Modulating
Fixed 10%, adjustable
10...90º
Modulating
Fail-Safe

Max. close-off pressure of BU6..(S)/L..(S) valves with Rotary Actuators (IP54) (kPa)
Actuator SRFU..-5 GRKU..-5/-7 SRVU..-5 GRVU..-5/-7 DGRVU..

Valve
BU650.. 1200 1200
BU665.. 1200 1200
BU680.. 1200 1200
BU6100.. 1200 1200
BU6125.. 1200 1200
BU6150.. 1200

58
Non-Linear DRVU.. Actuators
Large Torque Multi-function Actuators

DRVU.. • Non-Linear Actuators for operation of DN125...150 Butterfly Valves


• Torque 90Nm (non-linear)
• Open/Close or 3-point control: DRVU24G-T, DRVU230G-T
• Modulating control: DRVU24G-MF-T

SY.. • Large Torque Multi-function Actuators for operation of DN50...500


Butterfly Valves
• Torque 35…1500Nm 6
• Open/Close or 3-point control: SY..24-3-T, SY..230-3-T
• Modulating control: SY1U24-SR-T, SY1U230-SR-T
SY..U24-MF-T, SY..U230-MF-T (SY2..8)
• MP models available on request

Ordering example
DRVU 24G MF -T
With terminal eg. Modulating control
Default: Open/Close or 3-point control DRVU24G-MF-T
“Multi-function”: Modulating control Open/Close
“24G”: 24V nominal voltage DRVU24G-T
“230G”: 230V nominal voltage
Model number

SY4 U24 -MF -T


With terminal eg. Modulating control
“Multi-function”: Modulating control SY4U230-MF-T
“-3”: Open/Close or 3-point control Open/Close, or 3-point control
“U24”: 24V nominal voltage (modulating) SY4-24-3-T
“U230”: 230V nominal voltage (modulating)
“-24”: 24V nominal voltage (Open/Close, 3-point)
“-230”: 230V nominal voltage (Open/Close, 3-point)
Model number

Rotary Actuators (IP66/67)


Open/Close or 3-point Modulating
Type DRVU DRVU SY.. SY.. DRVU24G SY..U24 SY..U230-
24G-T 230G-T -24-3-T -230-3-T -MF-T -SR/MF-T SR/MF-T
Voltage
AC 230V
AC 24V
Control mode
Open/Close or 3-point
Modulating
Control/Feedback signal DC (0)2...10V (standard)
Degree of protection: IP66/IP67
2 auxiliary switches
Heater
Torque range: 20...1500Nm
2000...3500Nm (on request)

59
Non-Linear DRVU.. Actuators
Large Torque Multi-function Actuators

Max. close-off pressure of BU6..(S)/L..(S) valves with Rotary Actuators (IP66/67)


(kPa)
Actuator SY3-24 SY4-24
DRVU24G DRVU230G DRVU24G /230-3-T /230-3-T SY6-230-3-T SY7-230-3-T SY8-230-3-T
-T -T -MF-T SY3U24/230 SY4U24/230 SY6U230 SY7U230 SY8U230
(90Nm) (90Nm) (90Nm) -MF-T -MF-T -MF-T -MF-T -MF-T
Valve non-linear non-linear non-linear (150Nm) (400Nm) (650Nm) (1000Nm) (1500Nm)

BU6125.. 1200 1200 1200


BU6150.. 1200 1200 1200
BU6200.. 1200
BU6250.. 1200
BU6300.. 1200
BU6350.. 1200
BU6400.. 1200
BU6450.. 1200
BU6500.. 1200

Default: only SY and DRVU Actuators and its Butterfly Valves are pre-calibrated and pre-assembled in the factory.

Electrical connections All SY actuator control elements are wired to a terminal strip under the main cover. Remove the cover
and insert the cables through the cable connector to reach the terminal strip. The connections should
be made according to the diagram. Before beginning this procedure, make sure that the power sup-
ply voltage is in accordance with the actuator’s name plate. After the terminal connections have been
made, move the actuator manually to the half-open position and make a preliminary check of the
wiring.

Manual operation Turn the override handwheel clockwise to close the actuator and counter clockwise to open it. This
provides manual operation.

Overload protection If the actual running torque exceeds the nominal torque, the overload protection will operate to pre-
vent the motor overload.

Complementary Motorised Butterfly Valves and Manual Butterfly Valves

Sea water Application Large size Butterfly Valve PN25 Butterfly Valve Manual Butterfly Valve
DN50...800 DN600...1200 DN50...500 DN50...500

60
Linear Actuators and Valves

7
Carefully matched valve range
Belimo also provides motorised 2-way and 3-way Globe Valves in its range for mixing applications in HVAC systems.

The key feature of the valves is high performance and quality combined with low leakage rates. For the most popular pressure of
PN16, they are available in nominal sizes from DN15 to DN150.

Innovative actuator range


The specially developed Linear Actuators are based on the proven technology of Belimo Damper Actuators. They allow reliable
operation of Globe Valves of up to 50mm stroke. The Linear Actuators are of extremely solid construction and are powerful and
very durable. They follow the same product philosophy as the actuators from the other ranges, including the methods of electrical
connection, mounting, etc.

The Linear Actuators are available in capacity ratings from 500N to 4500N. Electronic Fail-Safe version is also available.

Valves and actuators are usually supplied as combined functional units. However, they can also be ordered separately.

Optimum link-ups thanks to


MFT(2) Multi-Function Technology
Linear Actuators with MFT2 Multi-Function Technology incorporate in-
telligent electronics which allow the actuators to be matched precisely
to the valves. This produces a functional unit of valve and actuator with
extreme accuracy. MFT2 actuators are also able to transmit status and
operating signals to a central plant control system. This means that
they not only contribute to efficiency of operation but also reduce oper-
ating costs. Parameters are assigned to the actuators in the same way
as to damper actuators. MFT2 actuators are easy to incorporate into
field bus systems.

61
H series Globe Valves

External thread Flange PN16


2-way 3-way 2-way 3-way 2-way 2-way

H4..B H5..B H6..N H7..N H6..S H6..SP

Globe Valves
Only suitable as a mixing valve
Nominal width [mm] 15...50 15...50 15...100 15...150 15...150 15...150
Pipe connection External thread (ISO 228)
Flange PN16 (ISO 7005)
Flow characteristic A–AB equal-percentage (to VDI/VDE 2173)
N(ep)=3
B–AB linear
Temperature of medium 5…120°C
(-10°C with stem heating on request)
5...150°C
Leakage rate Control pass <0.05%Kvs
Bypass <1%Kvs
Areas of application Cold water and warm water
Steam and hot water
Closed water circuit
With max. 50% volume of glycol
Material Housing Open water circuit (ph>7)
Red casting brass Rg5
Valve cone/valve stem Cast iron GG25
Valve seat/bypass seat Stainless steel
Red casting brass Rg5/stainless steel
Cast iron GG25/stainless steel
Stainless steel
Stem gland seal EPDM O-ring
PTFE V-ring
Rated pressure [kPa] 1600 1600 1600 1600 1600 1600

Unions, flanges
Pipe connect or for H4/5..B Globe Valve accessory Blind flange for H7..N Globe Valve accessory
DN G Rp Type Material (for sealing the bypass)
15 G11/8” 1/ ”
2 ZH4515 Mall.cast iron, galv. DN Type Material
20 G11/4” 3/ ”
4 ZH4520 Mall.cast iron, galv. 15 ZH715 Blind flange, coated
G
Rp 25 G11/2” 1” ZH4525 Mall.cast iron, galv. 20 ZH720 Blind flange, coated
32 G2” 11/4” ZH4532 Mall.cast iron, galv. 25 ZH725 Blind flange, coated
40 G21/4” 11/2” ZH4540 Mall.cast iron, galv. 32 ZH732 Blind flange, coated
50 G23/4” 2” ZH4550 Mall.cast iron, galv. 40 ZH740 Blind flange, coated
Included in delivery of ZR45..: female fitting, union nut, flat gasket. 50 ZH750 Blind flange, coated
65 ZH765 Blind flange, coated
80 ZH780 Blind flange, coated
Blind screw fitting for H5..B Globe Valve accessory
100 ZH7100 Blind flange, coated
(for sealing the bypass)
Included in delivery of ZH7..: blind flange, flat gasket, hexagon
DN G Type Material
screws, nut.
15 G11/8” ZH515 Mall.cast iron, galv.
20 G11/4” ZH520 Mall.cast iron, galv.
G 25 G11/2” ZH525 Mall.cast iron, galv.
32 G2” ZH532 Mall.cast iron, galv.
40 G21/4” ZH540 Mall.cast iron, galv.
50 G23/4” ZH550 Mall.cast iron, galv.
Included in delivery of ZH5..: blind flange, union nut, flat gasket.
62
Linear Actuators NV/NVF

Modulating, multifunctional 3-point


NVG24-MFT NV24-MFT2 NVY24-MFT NV24LON NV230-3 NV24-3

Type
AC 230V
AC/DC 24V
Stroke [mm] 20 20 20 20 20 20
Force1) (N) 1600/1600 1000/800 1000/800 1000/800 1000/800 1000/800
Positioning time: 3.8 or 7.5s/mm, selectable
Running time: (75)s...150s, adjustable
35s, adjustable
Control signal: 3-point
DC 0...10V(0...32V)
7
LonMark Functional Profile #8110
Feedback signal: DC 2...10V, adjustable
Integrated MP-Bus interface
Input for active/passive sensors, switches
Closing point selectable
Automatic stroke adaptation

1) Closing force/Inhibiting force

Mechanical Fail-Safe Rotary Actuators


Modulating, multifunctional
NVF24-MFT2 NVF24LON NVF24-MFT2-E NVF24LON-E

Type
AC/DC 24V
Stroke [mm] 20 20 20 20
Force (N) 800 800 800 800
Running time: 75s...150s, adjustable
Emergency control time: <1.5s/mm (spring)
Emergency control function: pulling (closes H4..B, H5..B, H6..N and H7..N)
pushing (closes H6..S and H6..SP)
Control signal: DC 0...10V(0...32V), adjustable
LonMark Functional Profile #8110
Feedback signal: DC 2...10V, adjustable
Integrated MP-Bus interface
Input for active/passive sensors, switches
Closing point selectable
Automatic stroke adaptation

63
Linear Actuators AV

Modulating, multifunctional 3-point


AV24-MFT2 AVY24-MFT AV24LON AV230-3 AV24-3

Type
AC 230V
AC/DC 24V
Stroke [mm] 40 40 40 40 40
Force1) (N) 2500/1700 2500/1700 2500/1700 2000/1700 2000/1700
Positioning time: 3.8 or 7.5s/mm, selectable
Running time: (75)s...150s, adjustable
60s, adjustable
Control signal: 3-point
DC 0...10V(0...32V)
LonMark Functional Profile #8110
Feedback signal: DC 2...10V, 0...10V, adjustable
Integrated MP-Bus interface
Input for active/passive sensors, switches
Closing point selectable
Automatic stroke adaptation

1) Closing force/Inhibiting force

New Generation Globe Valve Actuator (Retrofit)

• Universal valve interface, one for all - simple selection


• (NVA../SVA.. launch first)
• Extended product range - higher stroke force
• Higher close-off pressure achieved

NEW!
• Belimo quality product with brand new appearance
• Actuator configurable for customer specific needs
• Meets with various HVAC control signals as (0)2...10V, 4...20mA

NG Globe Valve Actuator will be available in mid of 2013.

64
Globe Valves with external thread/flange, 120ºC

NVD NVF NV NVG AV AV


500N 800N 1000N3) 1600N 2000N 2500N
20mm 20mm 20mm 20mm 40mm 40mm

Running times Control/


(Operating range)
3-Point AC/DC 24V 7.5s/mm/3.8s/mm 2 wires NV24-3 AV24-3
AC 230V 7.5s/mm/3.8s/mm 2 wires NV230-3 AV230-3
Modulating AC/DC 24V 150s DC (0)2...10V NVD24-SR
Multifunctional2) AC/DC 24V NVY 35s/AVY 60s DC (0)2...10V NVY24-MFT AVY24-MFT
150s DC (0)2...10V NV24-MFT2 NVG24-MFT AV24-MFT2
Motor: 150s DC (0)2...10V NVF24-MFT2
Spring: 30s NVF24-MFT-E4)

External thread (ISO 228) PN16, Tmax=120ºC1) Range of US 7


2-way 3-way close circuits, open circuits (pH>7)

DN kvs Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax


[mm] [m3/h] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]
H411B...H415B H511B...H515B 15 0.63/1/1.6/2.5/4 1600 400 1600 400 1600 400 1600 400
H420B H520B 20 6.3 1000 400 1600 400 1600
H425B H525B 25 10 600 400 1600 400 1350
H432B H532B 32 16 400 400 1600 400 1000 1600
H440B H540B 40 25 230 230 800 400 550 400 980
H450B H550B 50 40 600 280 350 350 600 400

Flange (ISO 7005) PN16, Tmax=120ºC1) Range of US


2-way 3-way close circuits

DN kvs Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax


[mm] [m3/h] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]
H611N...H615N H711N...H715N 15 0.63/1/1.6/2.5/4 1600 400 1600 400 1600 400 1600 400
H620N H720N 20 6.3 1000 1600 1600
H625N H725N 25 10 600 1600 1350
H632N H732N 32 16 400 400 1600 1000 1600
H640N H740N 40 25 230 230 800 400 550 400 980
H650N H750N 50 40 600 280 350 350 600 400
H664N H764N 65 58 400 160 200 200 320 320
H665N H765N 65 63 200 400 400 500 400
H679N H779N 80 90 200 100 135 135 210 210
H680N H780N 80 100 270 270 340 340
H6100N H7100N 100 145 160 160 200 200
H7125N 125 220 90 90 115 115
H7150N 150 320 60 60 75 75

Flange (ISO 7005) PN6, Tmax=120ºC1) Range of US


2-way 3-way close circuits

DN kvs Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax


[mm] [m3/h] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]
H611R...H615R H711R...H715R 15 0.63/1/1.6/2.5/4 600 400 600 400 600 400 600 400
H620R H720R 20 6.3
H625R H725R 25 10 600
H632R H732R 32 16 400 400 600 600
H640R H740R 40 25 230 230 440 400 550 400
H650R H750R 50 40 280 280 350 350 600 400
H664R H764R 65 58 160 160 200 200 320 320
H679R H779R 80 90 100 100 135 135 210 210
H6100R H7100R 100 145 160 160 200 200

* Required bracket: UNV-002


1), 2), 3) and 4) see page 66.
65
Globe Valves with flange, 150ºC

NVF NV NVG AV AV
800N 10003)N 1600N 2000N 2500N
20mm 20mm 20mm 40mm 40mm

Running times Control/


(Operating range)
3-Point AC/DC 24V 7.5s/mm/3.8s/mm 2 wires NV24-3 AV24-3
AC 230V 7.5s/mm/3.8s/mm 2 wires NV230-3 AV230-3
Multifunctional2) AC/DC 24V NVY 35s/AVY 60s DC (0)2...10V NVY24-MFT AVY24-MFT
150s DC (0)2...10V NV24-MFT2 NVG24-MFT AV24-MFT2
Motor: 150s DC (0)2...10V NVF24-MFT
Spring: 30s NVF24-MFT-E5)

Flange (ISO 7005) PN16, Tmax=150ºC Range of US


P
2-way close circuits, steam: pressure ratio<0.4 [ ]
P1

DN kvs Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax


[mm] [m3/h] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]
H610S...H615S 15 0.4/0.63/1/1.6/2.5/4 1600 1000 1600 1000 1600 1000
H619S/H620S 20 4/6.3 1320 1600
H624S/H625S 25 6.3/10 1080 1000 1350
H632S 32 16 800 800 1000 1000 1600 1000
H640S 40 25 440 440 550 550 980 980
H650S 50 40 280 280 350 350 600 600
H664S 65 58 200 200 320 320
H665S 65 63 400 400 500 400
H680S 80 100 270 270 340 340
H6100S 100 145 160 160 200 200
H6125S 125 220 90 90 115 115
H6150S 150 320 60 60 75 75

Flange (ISO 7005), PN16, Tmax=150ºC Range of US


P
partial pressure released close circuits, steam: pressure ratio<0.4 [ ]
P1
2-way
DN kvs Ps Pmax Ps Pmax Ps Pmax Ps Pmax Ps Pmax
[mm] [m3/h] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]
H640SP 40 25 1600 1000 1600 1000
H650SP 50 40 1600 1000 1600 1000
H664SP 65 58 1350 800 1600 800
H679SP 80 90 1350 400 1600 400
H6100SP 100 145 600 400 600 400
H6125SP 125 220 600 300 600 300
H6150SP 150 320 600 200 600 200

*Required bracket for NV... types: UNV-002.


1) Temperature of -10…+5ºC with stem heating - excluding globe valves H7125N, H7150N.
2) MFT type: Running times, control signal, stroke limitation and other functions can be parameterised with PC-Tool or the parameterising device ZTH-GEN.
Delivery state: modulating .
3) Closing force 1000N/Inhibiting force 800N.
4) When NVF..E is de-energised, Globe Valves H..B, H..N and H..R are open (NO).
5) When NVF..E is de-energised, Globe Valves H6..S, and H6..SP are closed (NC).

66
8

Flexible combination, perfect connection


Belimo Retrofit Actuators

67
Linear Actuators AV retrofit

Modulating, multifunctional 3-point


AV24-MFT2-R AVY24-MFT-R AV24LON-R AV230-3-R AV24-3-R

Type
AC 230V
AC/DC 24V
Stroke [mm] 50 50 50 50 50
Force1) (N) 2500/1700 2500/1700 2500/1700 2000/1700 2000/1700
Positioning time: 3.8 or 7.5s/mm, selectable
Running time: (75)s...150s, adjustable
75s, adjustable
Control signal: 3-point
DC 0...10V(0...32V)
LonMark Functional Profile #8110
Feedback signal: DC 2...10V, 0...10V, adjustable
Integrated MP-Bus interface
Input for active/passive sensors, switches
Closing point selectable
Automatic stroke adaptation

1) Closing force/Inhibiting force

68
Linkage selection guide

For use with For use with For use with


NRDVX.. NV.. NVG.. AV..-R
actuator 4) NVF.. actuators actuators 1)
Control Valve Manufacturer Nominal size
Lift up to Lift up to Lift up to
Valve Range DN[mm]
5.5mm 20mm 50mm
/ [inch]
Cazzaniga (EU) V2BM/V3BM 15...50 - UNV-012 -
V02BM..LM/V03BM..LM 15...40 -CA - -
Controlli VSB/VSB..F, VMB/VMB..F 15...50 - UNV-036 -
Trend GIBT/21, GIBT/31, GIBF/21, GIBF/31 15...50 - UNV-036 -
Danfoss (H)VL2/(H)VRB2/(H)VRG2 15...50 - UNV-038 -
(H)VE2/ (H)VF2 25...50 - UNV-038 -
(H)VFS2 15...20 - UNV-038 -
VR2 15...25 - UNV-038 -
O65B 15 - UNV-038 -
(H)VF3/ (H)VL3/ (H)VRB3/ (H)VRG3 15...50 - UNV-038 - 8
(H)VL2/ (H)VL3, (H)VF2/ (H)VF3 65...150 - - -
ARI BELIMO H4..H7 1/2”...3” - UNV-002 -
Honeywell (EU) V5049A 15...65 - UNV-015 -
V5049A 80...150 - - ZAV-004
V5014R/V5011R 15...50 - UNV-015 -
V5050A/V5328A/V5329A/5329C 15...80 - UNV-015 -
V5015A 100...150 - - ZAV-015
V5050A 100...150 - - ZAV-044
V5095A/V5015 20...80 - UNV-015 -
Honeywell (USA) V5011/V5013 1/2”...3” - UNV-006 -
V5011N/V5013N 1/2”...3” - UNV-006 -
HORA (EU) BR216RGA/BR316RGA 1/2”...2” - UNV-024 -
BR206GG/BR216GG/BR306GG/BR316GG 15...50 - UNV-024 -
BR225RG 15...25 - UNV-024 -
Johnson Controls (EU) VG7201/VG7203/VG7401/VG7403/VG7802/VG7804 15...20 - UNV-019/0412) -
VG7201/VG7203/VG7401/VG7403/VG7802/VG7804 25...50 - UNV-030 -
VB7816 15...25 - UNV-030 -
VB7216 15 and 25 - UNV-041 -
BM-2..2/BM-2..8 15...50 - UNV-030 -
VB7216 20 - UNV-045 -
VBF-0..4/VBF-2..4/VBF-0../VBF-2..8 15...50 - UNV-034 -
VBF-0..4/VBF-2..4/VBF-0../VBF-2..8 65...100 - - ZAV-034
VG82../VG84../VBD-4..4/VG88../VG89../VBD-4..8 15...40 - UNV-034 -
VG82../VG84../VBD-4..4/VG88../VG89../VBD-4..8 50...150 - - ZAV-034
VB7216 32...50 - UNV-030 -
VB7816 32...50 - UNV-045 -
Johnson Controls (USA) V-3754/V-3974/V-4324/V-5844 3/4”...2” - UNV-008 -
VG7000 1/2”...3/4” - UNV-009 -
Landis (USA) Powertop/Series VP 658 1/2”...1 1/4” - UNV-004 -
Flowrite/Series VP 591 1/2”...1”(2”) - UNV-005 -
Osby3) (EU) MTV/MTR 15...50 - UNV-025 -
GTV/RTV/BTV 25...40 - UNV-025 -

Notes:
1) Instead of the retrofit actuators AV..-R, the standard actuator range AV.. has to be used directly without additional adapter.
2) UNV-019 is for temperature of medium max. 120ºC, UNV-041 is for temperature of medium max. 150ºC.
3) Osby valves of size DN15 to DN25 may only be operated with an actuating force of 750N (75% reduction).
4) For detailed technical data of NRDVX.. actuator, please contact your nearest Belimo representative.

69
Linkage selection guide

For use with For use with For use with


NRDVX.. NV.. NVG.. AV..-R
actuator 4) NVF.. actuators actuators 5)
Control Valve Manufacturer Nominal size
Lift up to Lift up to Lift up to
Valve Range DN[mm]
5.5mm 20mm 50mm
/ [inch]
Robertshaw (USA) V6600/V6700 1/2”...2” - UNV-007 -
V6800 3/4” -- UNV-007 -
Sauter (EU) V6R..F/VXD..F/VXE..F/V6F..F/V6G..F/V6S..F 15...50 - UNV-018 -
B6R..F/BXD..F/BXE..F/B6F..F/B6G..F/B6S..F 15...50 - UNV-018 -
BT43B 15...40 - UNV-043 -
V1T 15 - UNV-043 -
BXD..F/VXD..F 65...80 - - ZAV-18
VXE..F/BXE..F 65...100 - - ZAV-18
B6S..F/B6F..F/V6S..F/V6F..F 65...150 - - ZAV-18
Satchwell (EU) MZ/VZ 15...50 - UNV-023 -
MJF/VSF 15...32 - UNV-023 -
VSFMJF 40...50 - - ZAV-023
MZF/VZF 65...150 - - ZAV-023/0316)
MJF/VSF 40...50 - - ZAV-023
Siebe/Invensys (USA) VB7213/VB7223/VB7313 1/2”...2” - UNV-001 -
VB9000 1/2”...1 1/4” - UNV-001 -
Siemens (USA) VF599 Series 1/2”...2” - UNV-003 -
Siemens (L/S) (EU) VXF21/VXF31/VVF31 20(25)...80 - UNV-003 -
VXF21/VVF21 100 - - ZAV-003
VXF31/VVF31/VVF40 100...150 - - ZAV-003
VVG41/VXG41 15...50 - UNV-003 -
VVF41/VVF61 65...150 - - ZAV-003
VXF41 65...150 - - ZAV-003
VVF45 50...150 - - ZAV-003
VVF40/VXF40/VVF21 15...80 - UNV-003 -
VVF52/VPF52/VXF41/VPF53E/VPF52F 15...40 - UNV-003 -
VVF61/VXF61 15...25(32) - UNV-003 -
VXF61 65...150 - - ZAV-003
VXF61/VVF61 40...50 - - ZAV-003
VVF41/VXF41 50 - - ZAV-003
VVG44.. 15...40 -SI - -
VVI52.. 15 -SI - -
VXG44.. 15...40 -SI - -
(Universal) / - UNV-0107) -
TAC (EU) V241/V341/V348 15...50 - UNV-017 -
V294 15 - UNV-050 -
V294 20...32 - UNV-017 -
V265/V295 40...65 - - ZAV-017
V221 65...150 - - ZAV-017
V395-1 40...100 - - ZAV-017
MUT MK 15...50 - UNV-047 -

Note:
5) For detailed technical data of AV..-R actuators, please contact your nearest Belimo representative.
6) ZAV-023: for valve with ¼” stem head, ZAV-031: for valve with 3/8” stem head (eg VZF1777 80, MZF 3779 80).
7) The UNV-010 is designed for universal linkage applications. It contains the universal bracket and coupling without any stem and valve neck adapter.

The list of linkages is continually growing; if your valve is not on the list, contact your nearest Belimo representative.

70
9

We can measure it
Quality Energy Meter
Supplementary products

Belimo is doing everything to satisfy customer needs. Certain third party products, e.g. controllers and zone valves, which can complete
Belimo’s product portfolio, are sourced externally.

These products are all carefully selected and have gone through Belimo’s strict quality inspections and procurement processes. The
product design, applications and reliability reach the highest standard in the industry.

Belimo is constantly updating the supplementary product list. New design zone valve products will be introduced to extend the range
further.

Fan Coil Valves and Controllers


DN15 to DN25, 2-way and 3-way, spring return type and non-spring return type, Belimo offers flexible options for Fan Coil applications.

Energy Meters
The tried and tested oscillating jet principle guarantees reliable,
long-term metering of thermal energy and flow.

72
Fan Coil Valves and Actuators

General Rotary Actuator


Valve RB..
Medium +5...+100°C chilled water or hot water
Applications Cold water and hot water systems
Nominal size DN15/20/25
Design 2-way/3-way
Rated pressure 2000kPa
Close-off pressure 600kPa
Pipe connection Female ISO 7/1
Materials Body Forged brass
Ball Stainless steel
Spindle Chromed-plated brass
Actuator FRU230-3 FRU24
Rated voltage AC 230V, 50Hz AC/DC 24V
Connecting 1m long, PVC cable 1m long, PVC cable
Running time 105s 100s
Torque 2Nm 2Nm
Manual override Pushing knob Pushing knob 9
Valve assembly Belimo one screw solution Belimo one screw solution
Position indicator Plastic knob marking Plastic knob marking
Ambient temperature range +5...+50°C +5...+50°C
Temperature of medium +5...+100°C +5...+100°C
Non-operating temperature -40...+80°C -40...+80°C
Humidity test To EN 60730-1 To EN 60730-1
Degree of protection IP40 IP40

Mechanical Fail-Safe Rotary Actuator


Rated power supply Z..S-24 AC 24V +/-10%
Z..S-230 AC 230V +/-10% 50/60Hz
Design 2-way/3-way
Power consumption 6.5 Watts, 7VA
Connecting cable 10cm long; 2x0.75mm2
Operating time - Motor 13...18s
- Spring 4...5s
Ambient temperature range 0...+40°C
Action - Spring return
- Normally closed
Medium Chilled water or hot water, up to 50% Glycol
Size 1/2”, 3/4”, 1”
Type of fitting Internal thread BSP
Materials Actuator Stainless steel base plate ABS cover
Valve body Forged brass
Valve flap NBR
Fire protection rating ABS UL94-V0
Pressure rating 2100kPa (300PSI-PN20)
Close-off pressure 303...414kPa (44...60PSI)
Media temperature range 0...+93°C (non-freezing)
Maintenance Maintenance-free

73
Room Thermostats for Fan Coil Application

CFU-D221 CFU-D222 CFU-D422 CFU-M211 CFU-M212

Type
Nominal voltage AC 100...240V
AC 220...240V
System 2-pipe system
4-pipe system
Mode Cooling only
Cooling and/or Heating
Setpoint range 5...35°C
10...30°C
3-speed fan control Manual
Automatic/Manual
Operation Normal
Standby
Economy
Temperature sensor Internal sensor
External sensor EXT-TN-1072532
Input DI: Economy mode contact
Output DO: Max. 3(1)A relay output

Features:
• Input for external sensor
• Suits both US and BS junction box
• Manual 3 fan speed
• Open-close control by 2-wire or 3-wire actuator
• Hidden LED indicate status

74
Room Temperature Controllers

T24-DM1 T24A1T CR24-B1 CR24-B2 CR24-B3 CR24-B2E

Type
Nominal voltage AC 24V±20%
Control mode P
P/PI selectable
Temperature sensor Internal sensor
External sensor NTC 5kΩ, range 0...45ºC
External sensor TG-K340B, range 0...40ºC
External sensor TG-M10000, range 0...40ºC
External sensor TG-M10002, range 0...40ºC
Input 2xAI, 2xDI
2xAI, 3xDI
2xAI, 1xDI
1xAI, 1xDI
Output 1xDC (0)2...10V
1x3-point AC 24V
2xDC (0)2...10V 9
Operation Mode switch and LED status indication
Setpoint adjustable 15...36ºC
Setpoint adjustable 0...40ºC
Setpoint adjustable 5...40ºC
Rotary knob for setpoint adjustment±3K (Internal)
Ambient temperature 0...50ºC
Dead band 1K
1...5K adjustable
Selectable proportional band
Function Setpoint control
Energy hold off
Stand-by
Boost
Change-over
Electrical reheater 1...3 stage
Screw terminals connection

75
Energy Meters

Thermal energy meter


Superstatic 440+Supercal 531+Temperature sensors

Belimo Trade Item


Nominal pressure PN16 Temp. sensor cable 3m
AC 24V power supply Sensor head cable 3m
Built-in M-Bus module
Pt500 sensor
EN 1434 Class 2

Threaded connection - Brass pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
440M0600 1.5m /h
3
110mm G 3/4” 0.1kWh 0.001m 3
0460R030 0460A206
440M1000 2.5m3/h 190mm G 1” 0.1kWh 0.001m3 0460R030 0460A206
440M1600 6.0m /h
3
260mm G 1-1/4” 1kWh 0.01m 3
0460R531 0460A207
440M2000 10m3/h 300mm G 2” 1kWh 0.01m3 0460R531 0460A207

Flange connection - Brass pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
440M2200 10m /h
3
300mm DN40 1kWh 0.01m 3
0460R531 0460A207

Flange connection - Stainless steel pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
440X2400 15m /h
3
270mm DN50 1kWh 0.01m 3
0460R531 0460A207
440X2600 25m3/h 300mm DN65 1kWh 0.01m3 0460R532 0460A208
440X3000 40m /h
3
300mm DN80 0.01MWh 0.1m 3
0460R532 0460A208
440X3400 60m3/h 360mm DN100 0.01MWh 0.1m3 0460R532 0460A208
440X3600 100m /h
3
250mm DN125 0.01MWh 0.1m 3
0460R532 0460A208
440X3800 150m3/h 300mm DN150 0.01MWh 0.1m3 0460R532 0460A208
440X4200 250m3/h 350mm DN200 0.1MWh 1m3 0460R533 0460A209
440X4400 400m /h
3
450mm DN250 0.1MWh 1m 3
0460R533 0460A209

Flange connection - Coated steel pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
440X4600 800m3/h 500mm DN350 0.1MWh 1m3 *0460R852 0460A209
440X5000 1500m3/h 500mm DN500 0.1MWh 1m3 *0460R852 0460A209

*Connection cable is not included for sensor 0460R852, cable400 can be ordered separately.

The tried and tested oscillating jet principle of Superstatic flow sensors in combination with Supercal 531 integrators gurantees reliable, long-
term metering of thermal energy and flow.

Thread, EN ISO 228-1


Flange, DIN-EN 1092-1/DIN 2501/ISO 7005-1

76
Energy Meters

Thermal Energy Meter


Superstatic 440 (Cast-iron version)
Belimo Trade Item
Nominal pressure PN16 Temp. sensor cable 3m
AC 24V power supply Sensor head cable 3m
Built-in M-Bus module
Pt500 sensor
EN 1434 Class 2

Flanged connection - Cast-iron pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
440X2450 15m3/h 270mm DN50 1kWh 0.01m3 0460R531 0460A207
440X2650 25m3/h 300mm DN65 1kWh 0.01m3 0460R532 0460A208

*DN80...DN100 available upon request.

Thermal Energy Meter


Superstatic 449 9

Belimo Trade Item


Nominal pressure PN16 Temp. sensor cable 3m
AC 24V power supply Sensor head cable 0.8m
Built-in M-Bus module Integrator on top
Pt500 sensor
EN 1434 Class 2

Threaded connection - Brass pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
0449R0600 1.5m /h
3
110mm G 3/4” 0.1kWh 0.001m 3
0460R030 0460A206
0449R0700 2.5m3/h 190mm G 1” 0.1kWh 0.001m3 0460R030 0460A206

Compact Thermal Energy Meter


Supercal 539
Belimo Trade Item
Nominal pressure PN16 Temp. sensor cable 1.5m
AC 24V power supply R53 series, 2 pulse outputs
Pt10K sensor R28 series, power supply over M-Bus
EN 1434 Class 3 Pocket G 3/8”

Threaded connection - Brass pipe (EXT-..)

Model No. Nominal flow Mounting length Connection Energy unit Volume unit Sensor Pockets
0539R53J 0.6m3/h 110mm G 3/4” 1kWh 0.001m3 ø5x33mm 0460P013
0539R53L 1.5m3/h 110mm G 3/4” 1kWh 0.01m3 ø5x33mm 0460P013
0539R53N 2.5m /h
3
130mm G 1” 1kWh 0.01m3 ø5x33mm 0460P013
0539R28J 0.6m3/h 110mm G 3/4” 1kWh 0.001m3 ø5x33mm 0460P013
0539R28L 1.5m /h
3
110mm G 3/4” 1kWh 0.01m 3
ø5x33mm 0460P013
0539R28N 2.5m3/h 130mm G 1” 1kWh 0.01m3 ø5x33mm 0460P013

Thread, EN ISO 228-1


Flange, DIN-EN 1092-1/DIN 2501/ISO 7005-1

77
Product Index A-Z

AH-GMA 21 KH-LF1 22 SRVU24-S-5 58


AH-25 21 SRVU230-5 58
AN-20 21 LF.. 18 SRVU230-S-5 58
AV6-20 21 LH.. 16 SRVU24-SR-5 58
AV8-25 21 LFH 48 SY.. 59
AV24-3 64 LMU.. 11
AV24-3-R 68 LMV-D3-MP 34 TF.. 18
AV24-MFT2 64 LMV-D3-LON 34 TRF.. 41
AV24-MFT2-R 68 LRF.. 41 TR.. 41
AV24LON 64 LRQU.. 46 T24A1T 75
AV24LON-R 68 LRU.. 41 T24-DM.. 75
AV230-3 64 LRU24-MF 50 T24-V.. 35
AV230-3-R 68 LUS.. 16
LMQU.. 15 UK24LON 24
BAE72.. 29 UK24BAC 24
BE.. 31 MFT-P 24 UK24MOD 24
BF.. 28 UNV.. 69,70
BFG.. 28 NFU.. 19
BLE 31 NM..P.. 14 VAV 33
BLF.. 28 NMU.. 12
BU6.. 58 NMQU.. 15 WLF 41
NMV-D3-MP 34
CFU-D.. 74 NMV-D3-LON 34 ZAD24 20
CFU-M.. 74 NRU24-MF 50 ZAV.. 69
CR24-B1 75 NRFU.. 41 ZBAE72 29
CR24-B2 75 NRQU.. 46 ZBAE95 29
CR24-B3 75 NV24-3 63 ZDB-LF 22
CR24-B2E 75 NV24-MFT2 63 ZDB-TF 22
CMU.. 10 NV24LON 63 ZF8-LF 22
CUSTOMISATION 17 NV230-3 63 ZG-118 23
NVF24-MFT2 63 ZG-AFB 23
DRVU.. 59 NVF24-MFT2-E 63 ZG-AFB118 23
DGRVU.. 59 NVF24LON 63 ZG-GMA 23
NVF24LON-E 63 ZG-LF1 23
EFU.. 19 NVG24-MFT(2) 63 ZG-LF3 23
EPIV.. 51 ZG-NMA 23
EXT-440.. 76 P140A.. 20 ZG-SMA 23
EXT-0449.. 77 P200A-F 20 ZG-TF1 23
EXT-0539.. 77 P500A.. 20 ZH.. 62
P1000A.. 20 ZR23.. 43
FRU230-3 73 P2800A.. 20 ZTH-GEN AP 24
FSAF.. 27 P5000A.. 20 ZTPC600-B 29
FSLF.. 26 P10000A.. 20 Z..S-.. 73
FSNF.. 26 PICCV.. 50
GMU.. 14 Z-AF 23
GRKS.. 41 R2..AC/R3..AC/R6..AO 43 ZF.. 23
GRVU24-5/7 58 R6..AS 48
GRVU230-5/7 58 RB.. 73
GRVU24-SR-5/7 58
S1A.. 20
H4..-H7.. 62 S2A.. 20
S2A-F 20
IND-AFB 21 SB-TF 22
SFU.. 19
K6-1 21 SGA24 20
K7-2 21 SGE24 20
K-ENSA 21 SGF24 20
K-NA 21 SMDU230 15
K-SA 21 SM..P.. 14
KG8 21 SMU.. 13
KG10A 21 SMQU.. 15
KH12 22 SHS.. 16
KH8 22 SRFU.. 41
KH10 22 SRQS.. 46
KH-AFB 22 SRU24-MF 50
KH-LF 22 SRVU24-5 58
78
79
80
Markets Asia Pacific

ASIA PACIFIC HEADQUARTERS Japan Office:


Belimo Actuators Ltd. Belimo Actuators Ltd.
Room 207, 2/F, New Commerce Center 7th Floor, Honjo-Azumabashi DJ Building
19 On Sum Street, Shatin, N.T. 4-19-3, Honjo, Sumida-ku
Hong Kong Tokyo 130-0004 Japan
Tel: +852 2687 1716 Tel: +81-3-6823-6961
Fax: +852 2687 1795 Fax: +81-3-3626-3911
E-mail: info.asiapacific@belimo.ch E-mail: info.japan@belimo.ch

Belimo AUSTRALIA Malaysia Office:


Melbourne Office: Belimo Actuators Ltd.
Belimo Actuators Pty. Ltd. 12-1, Jalan PJS 10/2, Subang Indah
12 Enterprise Court 46000 Petaling Jaya Selangor, Malaysia
Mulgrave Business Park Tel: +603 5631 2188
Mulgrave, VIC 3170, Australia Fax: +603 5638 2189
Tel: +61 (0)3 9545 0844 E-mail: info.malaysia@belimo.ch
Fax: +61 (0)3 9545 0855 Singapore Office
E-mail: info.australia@belimo.ch Belimo Actuators Ltd.
1 Tannery Road #08-04, One Tannery
Sydney Office:
Singapore 347719
Belimo Actuators Pty. Ltd.
Tel: +65 6842 1626
Suite 2.20, 32 Delhi Road
Fax: +65 6842 1630
North Ryde, NSW 2113, Australia
E-mail: info.singapore@belimo.ch
Tel: +61 (0)2 9805 1777
Fax: +61 (0)2 9805 1722 Taiwan Office:
E-mail: info.australia@belimo.ch Belimo Actuators Ltd.
7F-2, No.343, Jhonghe Road, Yonghe City
Belimo CHINA Taipei County 234, Taiwan
Shanghai Office: Tel: +886 2 2922 8805
Belimo Actuators (Shanghai) Trading Ltd. Fax: +886 2 2922 8806
479 Chun Dong Road, Building C-2 E-mail: info.taiwan@belimo.ch
Xin Zhuang Industry Park
Shanghai 201108 Thailand Office:
P.R. China Belimo Actuators Ltd.
Tel: +86 21 5483 2929 90/2 Pensiri Place
Fax: +86 21 5483 2930 Soi Phaholyothin 32, Phaholyothin Road
E-mail: info.shanghai@belimo.ch Chandrakasem, Jatujak
Bangkok 10900, Thailand
Beijing Office: Tel: +662 9415582-3
Belimo Actuators Ltd. Fax: +662 9415584
Room 605, Hai Chang Edifice E-mail: info.thailand@belimo.ch
44 Liang Ma Qiao Road
Beijing 100016 Belimo INDIA
P.R. China Mumbai Office:
Tel: +86 10 6462 1382 Belimo Actuators India Pvt. Ltd.
Fax: +86 10 6462 1383 23/ ABCD, Govt. Industrial Estate,
E-mail: info.beijing@belimo.ch Charkop, Kandivali West,
Mumbai 400067, India
Chongqing Office: Tel: +91 22 4025 4800
Belimo Actuators Ltd. Fax: +91 22 4025 4899
Room 4, 9th floor, Unit 7, Luoma Jiari Gardan E-mail: info.india@belimo.ch
No. 36, Qing Ling Road, Nan'an District
Bangalore office:
Chongqing 400060
Belimo Actuators India Pvt. Ltd.
P.R. China
Sreerama Complex,
Tel: +86 23 6275 3155
No. 13, 2nd Floor, 5th Cross Road,
Fax: +86 23 6280 3380 *519
6th Block, Koramangala,
E-mail: info.chongqing@belimo.ch
Bangalore – 560097, India
Guangzhou Office: Tel: +91-80-40906311
Belimo Actuators Ltd. Fax: +91-80-40906288
Room 1202, Skyline Plaza E-mail: info.india@belimo.ch
644 Tong Fu East Road, Haizhu Area New Dehli Office:
Guangzhou 510240 Belimo Actuators India Pvt. Ltd.
P.R. China Flat No. 516, DLF Tower – B,
Tel: +86 20 3435 1860 Jasola Distt. Centre, Jasola,
Fax: +86 20 3435 1870 New Delhi 110025, India
E-mail: info.guangzhou@belimo.ch Tel: +91 11 41078501 to 41078507
Fax: +91 11 41078508
Belimo HONG KONG E-mail: info.india@belimo.ch
Hong Kong Office:
Belimo Actuators Ltd. Chennai Office:
Room 207, 2/F, New Commerce Center Belimo Actuators India Pvt. Ltd.
19 On Sum Street, Shatin, N.T. #25, Bagavadam Street, T-Nagar
Hong Kong Chennai - 600017, India
Tel: +852 2687 1716 Tel: 91 44 42999450
Fax: +852 2687 1795 Fax: 91 44 42999451
E-mail: info.hongkong@belimo.ch E-mail: info.india@belimo.ch 81
Innovation, Quality
and Consultancy:
Fire &
Smoke A partnership for
motorising HVAC
actuators

Damper

PICCV
EPIV
EV

CCV

Butterfly
93010-00159

Valve
Belimo regional head offices

EU BELIMO Automation AG AP Belimo Actuators Ltd. US BELIMO Aircontrol (USA), Inc. Or contact your nearest Sales Representative
Brunnenbachstrasse 1 Room 207, 2/F, New Commerce Center 43 Old Ridgebury Road
8340 Hinwil, Switzerland 19 On Sum Street, Shatin, N.T., Hong Kong Danbury, CT 06813-2928
Tel: +41 43 843 61 11 Tel: +852 2687 1716 USA
Fax: +41 43 843 62 68 Fax: +852 2687 1795 Tel: +800 543-9038 / 203 791-9915
E-mail: info@belimo.ch E-mail: info.asiapacific@belimo.ch Fax: +800 228-8283 / 203 791-9919 www.belimo.com

You might also like