Professional Documents
Culture Documents
1 Alarms ........................................................................................................................... 3
1.1 Alarms List ........................................................................................................... 3
1.2 Alarm History List ............................................................................................. 6
1.3 Abnormalities not displayed........................................................................... 8
1.4 Main equipment ................................................................................................. 9
1.5 Special equipment .......................................................................................... 14
1.6 Discharge equipment...................................................................................... 15
1.7 Heater .................................................................................................................. 16
1.8 Sludge equipment ............................................................................................ 18
1.9 Feed module equipment ................................................................................ 18
1.10 Oil detach
(only valid for PureBilge 5015 & 5005) ..................................................... 19
1.11 Oil monitor.......................................................................................................... 20
1.12 Polishing filter ................................................................................................... 22
1.13 Flowmeter........................................................................................................... 22
1.14 Chemical dosing .............................................................................................. 22
1.15 Vibration ............................................................................................................ 23
2 Separator Faults.................................................................................................. 25
2.1 Separation Problems....................................................................................... 25
2.2 Mechanical Problems ..................................................................................... 26
592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
2 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
1 Alarms
4 5 6
NOTE EPC 60 Bilge
1 2 3
The latest 50 alarms are stored in the Alarm History
. 0
List. See below.
i
OVERBOARD REMOTE
CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X0 25 06 8 B
Press the arrow buttons to go up or down in the
list. 7 8 9
4 5 6
EPC 60 Bilge
1 2 3
. 0
i
OVERBOARD REMOTE
CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X 02 50 56 B
592107-02 3
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
1 2 3
X02 50 3 74 B
VFD CIP FEED PPM
FEED PUMP SLUDGE CLEANING PUMP
CONTROL PUMP IN PLACE
X0 23 91 9A
NOTE
4 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
4 5 6
EPC 60 Bilge
1 2 3
. 0
i
OVERBOARD REMOTE
CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X02 50 5 5B
VFD CIP FEED PPM
FEED PUMP SLUDGE CLEANING PUMP
CONTROL PUMP IN PLACE
592107-02 5
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
1 2 3
. 0
i
OVERBOARD REMOTE
CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X02 50 5 5B
VFD CIP FEED PPM
FEED PUMP SLUDGE CLEANING PUMP
CONTROL PUMP IN PLACE
4 5 6
1 Parameter menu – List of all parameters. EPC 60 Bilge
1 2 3
Password protected.
. 0
To go directly to a parameter, enter the
parameter number.
i
REMOTE
2
OVERBOARD
Time settings – For setting date, time, etc. CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X0 25 0 56 B
VFD CIP PPM
Password protected. FEED PUMP
CONTROL
SLUDGE
PUMP
CLEANING
IN PLACE
FEED
PUMP
6 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
1 2 3
i
OVERBOARD REMOTE
CONTROL FILTER DISCHARGE
CONTROL HEATER SEPARATOR
X02 50 3 74 B
VFD CIP FEED PPM
FEED PUMP SLUDGE CLEANING PUMP
CONTROL PUMP IN PLACE
592107-02 7
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
Why? What to do
• Oil level in oil sump too low. Check oil level and add oil if
necessary.
Noise • Height position of paring disc is Stop the separator, measure and
incorrect. adjust the height.
8 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
A020 A021
A020-A025 A024 A025
A032 A030-A032
TC
A001
A040-A045 A005
A TT1 TT2 V1
PT1
A015 A050-A053
A054 A056
A110-A111 A070-A074 A200
A222-A229
V10 V5
PT5
V15 CS
OCM
V16
ST
B QC
A123 A090-A097
A202
A122
A130-A139
A145 GS A120-A121
A130-A139
A145
LS
X02 4 96 8E
A Feedpump
B Supervision
592107-02 9
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
10 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 11
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
12 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 13
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
14 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 15
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
1.7 Heater
Alarm Alarm text Conditions Why? What to do
code
A005 Heater fault Delayed 2 s. • Power to heater Check the power supply to
(electric) interrupted. the heater.
A020 Feed temperature Delayed by P150. • Steam supply valve Investigate cause and
high Actual inlet temperature is faulty remedy.
over the limit P183. Start
blocking
• Faulty triac module(s) in
the power unit or faulty
controller in the control
unit. (electric heater).
• Broken wiring or
defective heater
resistance, or faulty
controller in the control
unit.
A021 Feed temperature Delayed by P150. • Heater clogged Investigate cause and
low Actual inlet temperature is remedy.
under the limit P184 in
PROD or P186 in CIP.
• Steam supply Investigate cause and
insufficient remedy.
• Steam trap faulty Investigate cause and
remedy.
• Steam supply valve Investigate cause and
faulty remedy.
A022 Temperature alarm Delayed by P150. • Short circuit / broken Disconnect cable at
sensor error Signal out of range. sensor or cable. sensor. Measure
TT201_1 (TT1) resistance between 1-3.
Resistance shall be within
100-142 ohms = 0-110 C/
32-230 F.
Replace sensor if broken.
If no spare sensor
available, set parameter
P146 = TT1 to be able to
run the system.
A023 Temperature alarm Reminder only, if P146 =
sensor disabled TT1
Possible to supervise the
system via TT2.
A024 Temperature Delayed by P169. • Insufficient heating Check heater function.
increase too slow The separator is in Start during start.
step, Insufficient heating,
temperature above low
limit P184 expected within
time in P169.
16 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 17
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
18 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 19
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
20 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
592107-02 21
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
1.13 Flowmeter
Alarm Alarm text Conditions Why? What to do
code
Flowmeter sensor (if P380> 0)
A204 Flowmeter error If the overboard valve is • Flowmeter has a fault
activated and there is no
pulses after P150 sec.
A205 Flow detected in Delayed by P150 • Overboard valve in Immediate action required
V5 recirculation If a flow is over P391 and wrong position. The to fint out cause of
Overboard valve V5 is on optional flow meter is overboard valve being in
recirculation position. The registering overboard wrong position.
alarm will e-stop the flow while the system Someone may have
machine. should be in
tampered with the
recirculation.
equipment.
- is SV5 manually
activated?
22 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 1 ALARMS
1.15 Vibration
Alarm Alarm text Conditions Why? What to do
code
Chemical dosing
A100 High level vibration Delayed by P150. • Pump no. 1 has a fault
Alarm limit in P182.
A101 HighHigh vibration Delayed 1 s. • Pump no. 2 has a fault
Alarm limit in P182.
A102 Vibration sensor Delayed by P150. • Signal out of range
error (4-20 mA).
A103 Vibration sensor •
disabled
592107-02 23
1 ALARMS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
24 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 2 SEPARATOR FAULTS
2 Separator Faults
2.1 Separation Problems
592107-02 25
2 SEPARATOR FAULTS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
26 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 2 SEPARATOR FAULTS
592107-02 27
2 SEPARATOR FAULTS PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
28 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 3 OIL CONTENT METER
592107-02 29
3 OIL CONTENT METER PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
30 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 4 FEED PUMP
4 Feed Pump
592107-02 31
4 FEED PUMP PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
Trouble Chart
The chart overleaf lists possible problems
– the type
– the likely reason / cause
– the remedy.
• A problem may have various causes:
Several boxes in the vertical column are
marked with a cross.
• A reason / cause may result in various
problems:
Several boxes in the horizontal column are
marked with a cross.
32 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 4 FEED PUMP
Possible Problems
592107-02 33
4 FEED PUMP PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND
Remedy
Fill the pump up, then pump through manually using a suitable appliance;
if necessary use glycerine as lubricant in the stator.
Check order information. Examine electrical installation (possibly 2 phase operation).
Measure the pressure with a manometer and check against order details. Reduce the pressure or change the drive.
Remove foreign bodies and eliminate possible damage.
If the liquid medium temperature cannot be lowered, use a reduced diameter rotor.
Check whether the liquid medium agrees with the order requirements. Possibly change stator material..
Increase the liquid part of the medium.
Clean the pump and rinse through after each run.
Increase the suction liquid level, prevent turbulance and air bubbles at the inlet.
Check seals and tighten pipe connections.
Stuffing box : tighten or renew. Mechanical seal : renew seals, eliminate solid deposits.
In the case of adjustable drives : increase the rpm. If necessary change the drive.
Warm up the pump (stator) to operating temperature first of all.
Decrease suction resistance, lower the temperature of the liquid medium, install the pump at a lower location.
Fill up the pump, provide for dry running protection, move the pipes.
Replace with a new stator or ensure correct liquid temperature.
Fit a new stator. Check the liquid medium agrees with order details; if necessary change the stator material.
Change rotor, establish the cause. Wear and tear, corrosion, cavitation;
if necessary change to a different material or coating.
Replace relevant parts, carefully reseal and lubricate.
Re-align the unit.
Use a new connection and re-align the pump.
Replace roller bearings, lubricate, reseal. At higher temperatures observe the lubricant and the bearings.
In the case of adjustable drives : lower the rpm.
Measure the viscosity and compare with order details. If necessary adjust viscosity or change the drive.
Measure specific weight and compare with order details. If necessary adjust specific weight or change the drive.
Service stuffing box according to page 7.4, if necessary renew worn shaft.
Replace fitted packing with another packing type.
Change electrical connection.
Replace relevant rings with new ones.
Replace elastomers. Check whether the liquid medium agrees with order details, if necessary change material.
34 592107-02
PUREBILGE BILGEWATER CLEANING SYSTEM ALARMS AND FAULT FINDING 5 CONSTANT PRESSURE MODULATING VALVE