You are on page 1of 3

Layout of Open Area

Dimensions of Open Area: 80 feet x 40 feet

Diagram showing layout of Open Area with 4 Pole Arrangement for Lighting
feet
40

80 feet
Lux Simulation Chart for Open Area Illumination
Solution: 450 Watts Platinum LED Floodlights
Height of Installation of Lights: 15 meters
Total Lights: 24 no.s; No. of Lights per Pole: 6
Total Power Consumption: 2700 Watts/Hour (2.7 KWh)
Diagram showing Lux Distribution using Isolines on Open Area

130 145 145 145 115


175 175 160
190 205
feet

205 205
205 205 175
175 205
220 220 220
175 205 205 205 160
145 220 205 145
40

205 205 205 190


190 205 175 205 145
160 175 160
130 160
115

80 feet

Lux Levels on Open Area:


Average Lux: 180 Lux; Min Lux: 103 Lux; Max Lux: 239 Lux
U0(Min/Avg):0.58; U1(Min/Max):0.43
Lux Simulation Chart for Open Area Illumination
Solution: 450 Watts Platinum LED Floodlights
Height of Installation of Lights: 15 meters
Total Lights: 24 no.s; No. of Lights per Pole: 6
Total Power Consumption: 2700 Watts/Hour (2.7 KWh)
Diagram showing Lux Distribution using Value Chart on Open Area

128 147 109 126 114 160 133 153 167 159 148 144 148 160 168 154 133 159 114 125 109 145 126
feet

187 218 181 103 218 185 196 219 214 201 186 181 186 201 214 216 195 185 216 104 180 219 187

114 145 155 186 211 223 239 234 230 217 202 196 201 216 231 234 239 225 212 185 154 145 116

144 167 150 179 203 228 230 224 216 212 212 210 212 212 216 224 230 228 203 179 150 167 144

116 145 154 185 212 225 239 234 231 216 201 196 202 217 230 234 239 223 211 186 155 145 114
40

187 219 180 104 216 185 195 216 214 201 186 181 186 201 214 219 196 185 218 103 181 218 187

126 145 109 125 114 159 133 154 168 160 148 144 148 159 167 153 133 160 114 126 109 147 128

80 feet

Lux Levels on Open Area:


Average Lux: 180 Lux; Min Lux: 103 Lux; Max Lux: 239 Lux
U0(Min/Avg):0.58; U1(Min/Max):0.43