Limits:
Kinematic Viscosity @ 100 degrees F:
Max change from new oil level is +25% to –10%
Total Acid No: 2.0 maximum
For units that operate less than 500 hours per year, sample annually.
Sampling port: Oil tank drain valve, GG gearbox drain port, or oil tank fill port.
Sample should be taken as soon as possible after gas turbine is shutdown.
Limits:
Kinematic Viscosity (cSt @ 40 degrees C / 100 degrees C: 30.4/5.1
Total Acid No: 1.6 maximum
Total solids: 50 ppm maximum
Change of Oil: Every 20,000 hours operation or 30 months, which ever occurs
first.
Change of Oil: No set interval. Change when properties are at limits. But every
6 months the reservoir should be drained and inspected for silt or sludge. The
cleanout doors should be removed and the reservoir cleaned by hand with a
solvent or light oil.
GENERAL NOTE: The above recommendations are based on data from Vendors and
PWPS documents. The PWPS documents and Vendor documentation on these systems
take precedent over this material.