You are on page 1of 4

Ericsson:

Alarm Cause TYPE


AntennaBranch_AntennaProblemInBranchA
AntennaBranch_AntennaProblemInBranchB
AntennaBranch_AntennaProblemInBranchC
AntennaBranch_AntennaProblemInBranchD
AntennaBranch_AntennaSystemProblemInBranchA
AntennaBranch_AntennaSystemProblemInBranchB
AntennaBranch_AntennaSystemProblemInBranchC
AntennaBranch_AntennaSystemProblemInBranchD
Equipment Malfunction AntennaBranch
AntennaBranch_FeederCurrentTooHighInBranchA
AntennaBranch_FeederCurrentTooHighInBranchB
AntennaBranch_FeederCurrentTooHighInBranchC
AntennaBranch_FeederCurrentTooHighInBranchD
AntennaBranch_FeederCurrentTooLowInBranchA
AntennaBranch_FeederCurrentTooLowInBranchB
AntennaBranch_FeederCurrentTooLowInBranchC
AntennaBranch_FeederCurrentTooLowInBranchD
Carrier_RxDiversityLost
Performance Degraded Carrier
Carrier_TxBranchFailure
NodeBFunction_16QamLicenseNotValid
NodeBFunction_64QamLicenseNotValid
NodeBFunction_DualStackIubLicenseNotValid
NodeBFunction_EnhancedLayer2LicenseNotValid
NodeBFunction_Eul2msTtiLicenseNotValid
NodeBFunction_EulGrakeLicenseNotValid NodeBFunction
NodeBFunction_HsdpaDynamicCodeAllocationLicenseNotValid
License Alarms
NodeBFunction_HsdpaFlexibleSchedulerLicenseNotValid
NodeBFunction_HsdpaImprovedLinkAdaptationLicenseNotValid
NodeBFunction_HsdpaIncrementalRedundancyLicenseNotValid
NodeBFunction_HsdpaMultiCarrierLicenseNotValid
RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit
RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit Cell Alarms
RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit
RruDeviceGroup_ConfigurationMismatchWithAntennaEquipmen
Configuration Alarm
t
RruDeviceGroup_ExternalUnitFailure
RruDeviceGroup_FanFailure
RruDeviceGroup_GeneralHwError Equipment Malfunction RRU Alarms

RruDeviceGroup_RetPortCurrentTooHigh
RruDeviceGroup_SfpModuleHwError
RruDeviceGroup_GeneralSwError Software Alarm
Huawei:

Alarm Cause TYPE


BBU Board Maintenance Link Failure
BBU CPRI Interface Error
BBU
BBU CPRI Optical Module or Electrical Port Not Ready
BBU Optical Module Transmit/Receive Fault
Local Cell Capability Decline Equipment Malfunction
RF Unit Clock Problem
RF Unit CPRI Interface Error
RF Unit Maintenance Link Failure
RF Unit Optical Module Fault Carrier
RF Unit TX Channel Gain Out of Range Configuration Alarm
Local Cell Unusable Multiple Causes
RF Unit RX Channel RTWP/RSSI Unbalanced RTWP Increased
RF Unit VSWR Threshold Crossed VSWR Alarm
Optic Power Abnormal
Equipment Malfunction CPRI
Optical Module Fault
Board Type and Configuration Mismatch
Inter-System Cabinet Configuration Conflict
RET Antenna Running Data and Configuration Configuration Alarm
Mismatch
RF Unit ALD Switch Configuration Mismatch Hardware
Board Software Synchronization Failure Software
Board Not In Position
Board Unavailable
RET Antenna Data Loss
Equipment Malfunction
RET Antenna Motor Fault
RET
RET Antenna Not Calibrated
RF Unit ALD Current Out of Range
ZTE:

Alarm Code Cause TYPE


19809225
Antenna feeder over VSWR alarm
7
19809844
Antenna feeder over VSWR alarm
4
19809228
Antenna feeder VSWR alarm VSWR Alarms
3
19809845
Antenna feeder VSWR alarm
4
Carrier
19809846
VSWR of the antenna feeder abnormal
5
19809224
RF board PLL alarm
9
19809224
Disable PA
5
19809225
Output power abnormal voltage alarm
4
19809229
The Rx optical port at RRU has no light signal
3
19809229
No optical signal is received at the optical port
0
CPRI
The received optical power of the optical module is 19809243
abnormal 1
19809228
Received frames of the optical port losing lock
6
19809243
The RRU network is interrupted
3
19809656
RRU device alarm
3
19809831
RRU physical layer link is interrupted
7 Equipment
19810027 Malfunction
RRU software version is abnormal
5
19809760
The RRU link is broken
5
19810027
RRU fiber delay beyond the limit
6
19809238
RRU device delay parameter configuration failure
7
19809234
RET communication link is interrupted
2
Hardware
19809234
RET don't calibrated
3
19809234
RET motor can't adjust
0
19809229
The frame transferred over Rx port of RRU is unlocked
4
19809201
Board communication link is interrupted
0
19809640
Board reboots
4
19809847
RRU Power Abnormal Alarm Power Alarm
2
19809655
RRU unconfigured Configuration Alarm
1
19809386
RTWP abnormal RTWP Increased
4

You might also like