You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

* UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN mm

27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01
KEY PLAN
N

CHILLER PLATFORM LEVEL


STR.STEEL PLATFORM FOR CHILLER SUPPORT STR.STEEL PLATFORM FOR CHILLER SUPPORT SSL

A A

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN
270mm HCS 270mm HCS
6th LEVEL
SSL
GENERAL NOTES :
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 +75mm TOPPING +75mm TOPPING

TYPE-C1 1. UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS


TYPE-A4 TYPE-C3
ARE IN mm.

2. DRAWING TO BE READ IN CONJUNCTION WITH


B STRUCTURAL,MECHANICAL AND ELECTRICAL B
INFORMATION.

5th LEVEL 3. EQUINIX MAJOR CAPITAL EQUIPMENT (MCE) SHALL


TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
270mm HCS
+75mm TOPPING
270mm HCS
+75mm TOPPING
SSL BE USED IN ALL INSTANCES UNLESS SITE SPECIFIC
CONSTRAINTS DICTATE OTHERWISE.
TYPE-C1

TYPE-A4 TYPE-C3

C 270mm HCS 270mm HCS


4th LEVEL
SSL
C
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 +75mm TOPPING +75mm TOPPING

TYPE-C1

TYPE-A4 TYPE-C3

3rd LEVEL
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
270mm HCS 270mm HCS SSL
+75mm TOPPING +75mm TOPPING

TYPE-C1

D TYPE-A4 TYPE-C3 D

2nd LEVEL
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
270mm HCS 270mm HCS SSL
+75mm TOPPING +75mm TOPPING

TYPE-C1

TYPE-A4 TYPE-C3

E E
1st LEVEL
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
270mm HCS 270mm HCS SSL
+75mm TOPPING +75mm TOPPING
TYPE-C1
150mm SS
75mm SCREEDING
TYPE-A4 TYPE-C3
CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN

CIS COLUMN
MEZZANINE
270mm HCS 270mm HCS LEVEL
STEEL BEAM STEEL BEAM
F TYPE-C1
+75mm TOPPING +75mm TOPPING SSL
F
TYPE-B3
TYPE-A4 TYPE-C3
CIS COLUMN

CIS COLUMN

LEVEL -0
SSL

PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB PB
GROUND LEVEL

G G

SECTION A-A
01 SCALE - 1:150

E D E D 05 04 03 02 01

H H
CHILLER PLATFORM LEVEL CHILLER PLATFORM LEVEL CHILLER PLATFORM LEVEL
SSL SSL SSL

SCREED
6th LEVEL 6th LEVEL SCREED 6th LEVEL SCREED SCREED SCREED
SSL SSL SSL

J HCS CIP HCS HCS


HCS
270mm
HCS
270mm TYPE-A4 HCS TYPE-C3
J
270mm BEAM 270mm 270mm TYPE-C5 270mm
TYPE-B2 TYPE-B2 TYPE-A9
TYPE-C5

5th LEVEL SCREED 450MM SUNK 5th LEVEL SCREED SCREED 5th LEVEL SCREED
350MM 350MM SCREED SCREED 450MM SUNK
SSL SSL SUNK SSL SUNK

HCS
HCS CIP HCS HCS 270mm
270mm BEAM 270mm HCS 270mm TYPE-C5 HCS TYPE-C7
TYPE-B2 270mm TYPE-B2 TYPE-A7
TYPE-B2 TYPE-B2 TYPE-A8 270mm
TYPE-C6
K K

4th LEVEL SCREED 450MM SUNK 4th LEVEL SCREED SCREED 4th LEVEL SCREED
350MM 350MM SCREED SCREED 450MM SUNK
SSL SSL SUNK SSL SUNK

HCS
HCS CIP HCS HCS 270mm
270mm BEAM 270mm HCS 270mm TYPE-C5 HCS TYPE-C7
TYPE-B2 270mm TYPE-B2 TYPE-A7
TYPE-B2 TYPE-B2 TYPE-A8 270mm
TYPE-C6
01 PRELIMINARY ISSUE 10/21/21 MMW RRS
27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01
No. Description Date Drawn Checked

C1 C2
TYPE-B6
TOP PROJECTION C3
TYPE-B6
TOP PROJECTION C4
TYPE-B6
TOP PROJECTION C5
TYPE-B6
TOP PROJECTION C6
TYPE-B6
TOP PROJECTION C7
TYPE-B6
TOP PROJECTION C8
TYPE-B6
TOP PROJECTION C9
TYPE-B6
TOP PROJECTION C10
TYPE-B6
TOP PROJECTION SW-3 TYPE-B2 C11
TYPE-B6
TOP PROJECTION C12
TYPE-B6
TOP PROJECTION C13
TYPE-B6
TOP PROJECTION C14
TYPE-B6
TOP PROJECTION C15
TYPE-B6
TOP PROJECTION C16
TYPE-B6
TOP PROJECTION C17
TYPE-B6
TOP PROJECTION C18
TYPE-B6
TOP PROJECTION C19 C20 TYPE-B2 C21 TYPE-B2 SW-4 C22
3rd LEVEL 3rd LEVEL SCREED SCREED 3rd LEVEL SCREED
A A
350MM 350MM SCREED SCREED
L L
TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

BEAM
TYPE-C5

TYPE-B5
TYPE-B5
SSL SSL SUNK SSL SUNK
HANGER
STEEL

TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5
TYPE-B5
SW-1

SW-2

150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB
TYPE-C4

+75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING
Drawing Status
TYPE-A6

TYPE-B5
BEAM

TYPE-B5
TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1
TYPE-A1

TYPE-C3
TYPE-A1
TYPE-B5
TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1
TYPE-B5

TYPE-C5
TYPE-B5

TYPE-A1
BEAM

HCS
PRELIMINARY ISSUE
TYPE-B5
TYPE-B5 270mm HCS
+75mm TOPPING
HCS CIP HCS HCS 270mm TYPE-A4 HCS TYPE-C3
TYPE-C1

TYPE-C1

SW-5 TYPE-B2
B BEAM
C23
B 270mm BEAM 270mm HCS 270mm TYPE-C5 270mm
TYPE-B2 TYPE-B2
BEAM

270mm
BEAM

TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 SW-6 C45

C C TYPE-B2 TYPE-A8
SW-9
SW-8

BEAM
TYPE-B5

C24
SW-7

C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 C42 C43 C44

TYPE-C6

i.d.a. international
TYPE-B5 TYPE-B2 TYPE-B2
TYPE-C5

270mm HCS
+75mm TOPPING
TYPE-A4
TYPE-A3

TYPE-C3

TYPE-B5

E
TYPE-A5
TYPE-C2

270mm HCS

150mm HALF SLAB


F +75mm TOPPING

+75mm TOPPING
TYPE-B2

SW-10 C47 C48

Building Services Consulting Engineers


C46 TYPE-B2
D D
STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER
STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

TYPE-A4

TYPE-C5
TYPE-C5

270mm HCS 270mm HCS


D SCREED SCREED SCREED SCREED
TYPE-A4

+75mm TOPPING +75mm TOPPING


C49 2nd LEVEL 450MM SUNK 2nd LEVEL 2nd LEVEL SCREED SCREED 450MM SUNK
TYPE-C3

150mm HALF SLAB


+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
150mm HALF SLAB
+75mm TOPPING
TYPE-B2
TYPE-B2

SSL SSL
350MM
SSL
350MM Unit 211, Aditya Banarasi Heritage
TYPE-C1

SUNK SUNK
TYPE-A3

TYPE-C4

270mm HCS
Off Malad Link Road
TYPE-A4

270mm HCS
+75mm TOPPING +75mm TOPPING
C50 C51
E TYPE-B2 E
HANGER

Mindspace, Malad (W)


TYPE-A4

TYPE-C3

RC BEAM
(200X650)
(350X650)
RC BEAM
RC BEAM

RC BEAM
(200X650)

(200X650)

F F
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
TYPE-B3 C71 HCS
G
C73
C74 C52 C53 C55 C58 C63
SW-11
C72

HCS CIP HCS HCS 270mm Mumbai, India 400064


SW-11A

C54 C60
SW-11B

C56 C57 C59 C61 C62 C64 C65 C66 C67 C68 C69 C70
G TYPE-C5
M 270mm HCS
M
STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB
150mm HALF SLAB
BEAM
STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

STEEL BEAM (ISMB)

270mm
TYPE-C3

150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB
TYPE-A4
TYPE-C1

150mm HALF SLAB


+75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING
270mm HCS TYPE-C7
TYPE-C1

TYPE-B5
+75mm TOPPING
TYPE-B2 270mm TYPE-B2 TYPE-A7 Tel: (91) 22 4266 1860
TYPE-A3
TYPE-C1

TYPE-B5
TYPE-C5

SW-12
FREIGHT ELEVATOR#01
TYPE-B2 TYPE-B2 TYPE-A8 270mm
C75 C76 C77 C78
H
J
TYPE-B5
TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
270mm HCS
H
J TYPE-C6 IN: (91) 9967504960
TYPE-C1

C79 +75mm TOPPING


TYPE-A4

TYPE-C3

C80
TYPE-C1

C81 C82 C83 C84 C85 C86 C87 C88 C89 C90 C91 C92 C93 C94 C95 C96 C97 C98 C99
270mm HCS
A +75mm TOPPING
A
SW-13A

SW-13B

SW-13 TYPE-B3 C101


K C100 K
RC BEAM

RC BEAM
(200X650)

(200X650)

(350X650)
RC BEAM
TYPE-A3
TYPE-C1

RC BEAM
150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB (200X650)
FREIGHT ELEVATOR#02
+75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING
TYPE-C3
TYPE-A4
TYPE-A4

150mm HALF SLAB


+75mm TOPPING

SCREED SCREED SCREED SCREED


STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER
STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

STEEL GIRDER

1st LEVEL 450MM SUNK 1st LEVEL 1st LEVEL SCREED SCREED 450MM SUNK
SW-14
C102 C103 C104
350MM 350MM
L L SSL SSL SUNK SSL SUNK
150mm HALF SLAB
+75mm TOPPING
TYPE-A2
TYPE-C1

TYPE-A4

TYPE-B5 270mm HCS 270mm HCS


TYPE-A3

TYPE-C3
TYPE-C5

+75mm TOPPING +75mm TOPPING


HCS
TYPE-B5
HCS CIP HCS HCS 270mm
TYPE-B5

C106
C105 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1 TYPE-B1
C126
270mm BEAM 270mm HCS 270mm TYPE-C5 HCS TYPE-C7
M M TYPE-B2 TYPE-B2 TYPE-A7
BEAM
BEAM

270mm
BEAM

C107 C108 C109 C110 C111 C112 C113 C114 C115 C116 C117 C118 C119 C120 C121 C122 C123 C124 C125
TYPE-B2 TYPE-B2 270mm
STEEL HANGER

BEAM
TYPE-A8
TYPE-A3

TYPE-A4

N N
SW-15
TYPE-C3

TYPE-B2
TYPE-B5
TYPE-C6
BEAM

TYPE-C6

TYPE-C6
TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-A1

TYPE-B5
BEAM

TYPE-B5

C128
P P
TYPE-C4

150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB 150mm HALF SLAB C127 C129
+75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING +75mm TOPPING TYPE-B2
STEEL HANGER

TYPE-C3

TYPE-B5

N 270mm HCS

N
SW-16

+75mm TOPPING
TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5 TYPE-B5
TYPE-B5
TYPE-B7
TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

TYPE-B7

SW-17
Q
BEAM C150
Q Project Title
C130 TYPE-B2 C131 C132 C133 C134 C135 C136 C137 C138 C139 C140 C141 C142 C143 C144 C145 C146 C147 C148 C149 TYPE-B4 TYPE-B4
SCREED SCREED

TYPE-A8
TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6 TYPE-B6
TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION TOP PROJECTION
MEZZANINE MEZZANINE MEZZANINE SCREED SCREED
LEVEL LEVEL LEVEL
27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 SSL SSL SSL
EQUINIX MB3
KEY PLAN CIP
BEAM
TYPE-B2 HCS
270mm
CIP
BEAM
HCS
270mm
CIP TYPE-C1 HCS
270mm
TYPE-A1 HCS
270mm
TYPE-C3

06 SCALE - 1:150
Drawing Title

STRUCTRURAL SECTION - AA
GRADE SLAB GRADE SLAB
LEVEL -0 LEVEL -0 150mm THK. LEVEL -0 150mm THK.
SSL SSL SSL

P P
GROUND LEVEL GROUND LEVEL GROUND LEVEL

Drawing Number

MB3-IDA-DC-ZZ-DR-S-SECTION-3001
SECTION D-D SECTION E-E SECTION F-F
03 SCALE - 1:150
04 SCALE - 1:150
05 SCALE - 1:150
Job No Revision Scale

20-913 A 1:150@A0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22