3. Check the board direction if it matches with program setup. (If the Automatic Width window pops up,
press “Yes” so the conveyor will move to the width according to the setup.)

3.

4. Click on “Inspection Mode” button to proceed.

4.
5.

5. Press “Start” button to initiate the inspection


a. c.

b.
6.

6. Scan the barcode (Make sure the barcode window is on the top), and if user want to exit
the inspection mode here, click on the “OK” button while leaving the barcode window
empty.
a. c.
b.
7.

7. Press the “Start Test” button on the VPLC panel so the


conveyor will load the board into the machine with
subsequent scanning process.
c.

a.

b. d.
8.

8. When the scan is complete, the inspection result will be sent to the
repair station automatically in auto mode. Otherwise, user will need to
press the “Fail” button manually to proceed this procedure in confirm
mode.
1.

1. Check if the Insert Data application is running. This program should start with the repair
station computer startup. If not, please start the program so the Insert Data dialog will appear
as shown above. Once the AXI machine complete its inspection, the data will first be sent to
the repair station’s C drive, and the “Insertdata” will then move the data from C drive to D
drive (by default) in folders categorized by date and model name. The files which have been
successfully transferred in this way will be displayed in both the message boxes “Before/After
Insert into DB” as shown in figure below.
2.

2. Open the XRayConfirm software and Log in


3.
4.

3. Go to the Main Program to proceed.


4. User can retrieve the historical information via archived data base
5.
3D Golden Image

2D Golden Image

3D Image
2D Image

Panel Map
Confirm Area

CAD Map

5. This is the main screen overview, user will have full


access to the board inspection data here.
Confirm Mode Selection

Board Info

Inspection
Result – Listed
Defect Component
by board
List Defect List

6.

6. Confirm Window: Full defect information is available here.


a.

7.

b. c.

7. Switch to “Online” mode and click “Query” to obtain unconfirmed board list. Number displayed
on the right hand side is the number of unconfirmed units.
a. b.
8.

8. In Offline mode, type in the barcode manually or using


barcode scanner, and then click “Query” to retrieve the
board data.
9.

9. Board Status Identification:


i. FAIL: The inspection result of the board is labeled FAIL and the board is not yet
confirmed by user.
ii. PASS: The inspection result of the board is PASS.
iii. REPAIR: The inspection result of the board is FAIL and the board is confirmed as true
defect board by user.
iv. SKIP: The inspection result is SKIP or the board is confirmed as a SKIP board by user.
(SKIP board will not be included in the statistic data.)
v. RPASS: The inspection result of the board is FAIL and the board is confirmed as a
PASS board by user.
10.

10. Enhance the image quality of the defects by pressing the above buttons,
and move the slide on the right for brightness adjustment.
11.

11. “Slice Image Count” is a 3D slice indicator showing what focal plane of the
component users are looking into.
12.
13.

14.

13. Retrieve the board data in “Offline Mode” in the main program or in the “Archived
Data” on the repair station menu.
14. For quick access to a single board defect data, offline mode is best to retrieve the
data with handy barcode (please refer to the page 25).
16.

15.

15. Information regarding the board defects can be found in the Archived data by
selecting the time interval, model name and station properly.
16. In general, if user want to review multiple board status at once, one should do
this with “Archived Data”.
1.

1. Exit the inspection mode


2.

2. Click on “Search FidMark” button. The system will try to relocate the position
of the board again.
3. Fiducial mark status will be
displayed here. The higher the
score, the better the board
been positioned. If the board is
not placed properly and firmly
on the pallet, fid error will likely
to happen in the middle of the
inspection.
4. Enable Fidmark Info. (Right click on the minimap)