You are on page 1of 6

Pe r f e c t i n g t h e A i r

Non-Inverter

COOLING ONLY [60Hz], 220V

The ul�mate solu�on for a refreshingly cool space

Japan
Quality
1 YEAR
WARRANTY

PARTS & LABOR


5 YEARS
WARRANTY

COMPRESSOR
WORLD’s

AIRCONDITIONING
COMPANY
Non-Inverter

Indoor unit
Ceiling Cassette Ceiling Suspended
FCRN50/60/71/100AXVL/125AXVL9 FHRN100AXVL/140AXVL9
2HP / 2.5HP / 3HP / 4HP / 5HP 4HP / 6HP

Floor Standing
FVRN71/100AXVL/125/140AXVL9
Duct Connection 3HP / 4HP / 5HP / 6HP
Standard Static Pressure Type
FDMRN50/60/71/100AXVL/125/140AXVL9
2HP / 2.5HP / 3HP / 4HP / 5HP / 6HP

Outdoor unit

RR50/60AGXVL RR71AGXVL RR100AGXVL


RR125/140AGXTL9

Fitted with wide inlet fan Pre-charged for up to 7.5 metres


Fully shaped aerodynamic Model Max. piping length, m Max. piping elevation, m
propellers are designed to RR50A
push air with a large wing 30 15
RR60A
surface, providing both high
blow volume and quiet RR71A 50 25
operation with turbulence. RR100A
RR125A 50 30
Wide inlet fan RR140A
Durability
• The unit is covered with corrosion-proof galvanized steel to enhance its durability.
• Heat exchange fins are provided with anti-corrosion treatment.
Non-Inverter
Work & Servicing Optional
Ceiling Cassette Drain pump mechanism Fresh-air intake kit
Pre-charged for up to 7.5m Group control by Network Interface Module (NIM)
Comfort Self-Diagnosis External command control using BAG
Auto-swing * Two selectable Wired Remote Controller
Swing Pattern temperature sensor
* Weekly scheduled timer
Switchable fan speed Control Features Cleanliness Others
Programme “Dry” * Applicable when wired controller
is used Auto random restart Washable Anti-corrosion treated
Timer Selector saranet filter heat exchangers

Indoor Unit FCRN50AXVL FCRN60AXVL FCRN71AXVL FCRN100AXVL FCRN125AXVL9


Model Name
Outdoor Unit RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9
Btu/hr 18,500 24,000 29,500 36,000 48,000
Rated Cooling Capacity (Min. ~ Max.)
kW 5.42 7.03 8.65 10.55 14.07
Power Consumption Watts 1,730 2,400 3,130 3,700 5,100
Total Running Current A 7.9 11 14.3 16.8 14.8
Power Supply Ph/V/Hz 1/220/60 3/220/60
COP W/W 3.13 2.93 2.76 2.85 2.76
Air Flow Rate (H/M/L/Q) cfm 730/620/510/360 840/700/560/440 890/760/620/490 1120/1030/890/760
Sound Pressure Level (H/M/L/Q) dBA 39/35/33/29 41/38/35/32 43/41/36/34 48/45/41/37 49/46/42/38
INDOOR Unit Dimension (H x W x D) mm 246 x 840 x 840 288 x 840 x 840
Deco Panel (H x W x D) mm 301 x 950 x 950 343 x 950 x 950
Machine Weight Kg 27 30
Sound Pressure Level dBA 50 57 61 66
Dimension (H x W x D) mm 651 x 855 x 328 753 x 855 x 328 852 x 1030 x 400
OUTDOOR Machine Weight Kg 43 57 71 87
Pipe Connection-Liquid mm 6.4 9.5
Pipe Connection-Gas mm 12.7 15.9
Minimum Piping Length m 3
Maximum Piping Length m 30 50
Maximum Piping Elevation m 15 25 30
Decorative Panel BC50F2XWA
Chargeless Refrigerant m 7.5
Additional Refrigerant Charge g/m 22 10 30 24

Ceiling Suspended
Work & Servicing Optional
Comfort Drain pump mechanism Group control by Network
Auto-swing Timer Selector Pre-charged for up to 7.5m Interface Module (NIM)
Swing Pattern * Two selectable temperature sensor Self-Diagnosis External command control
using BAG
Switchable fan speed * Weekly scheduled timer
Programme “Dry” * Applicable when wired controller is used Wired Remote Controller
Indoor Unit FHRN100AXVL FHRN140AXVL9 Indoor Unit FHRN100AXVL FHRN140AXVL9
Model Name Model Name
Outdoor Unit RR100AGXVL RR140AGXTL9 Outdoor Unit RR100AGXVL RR140AGXTL9
Btu/hr 35,000 56,000 Minimum Piping Length m 3 5
Rated Cooling Capacity (Min. ~ Max.)
kW 10.26 16.41
Maximum Piping Length m 50
Power Consumption Watts 3,800 6,240
Maximum Piping Elevation m 30
Total Running Current A 17.3 18.8
Power Supply Ph/V/Hz 1/220/60 3/220/60 Chargeless Refrigerant m 7.5

COP W/W 2.70 2.63 Additional Refrigerant


g/m 30 50
Charge
Air Flow Rate (H/M/L) cfm 1107/999/751 1550/1380/1000
Sound Pressure Level (H/M/L) dBA 49/46/43 56/54/51
INDOOR
Dimension (H x W x D) mm 235 x 1,903 x 680 285 x 1,903 x 680
Machine Weight Kg 52 70
Sound Pressure Level dBA 61 66
Dimension (H x W x D) mm 852 x 1,030 x 400
OUTDOOR Machine Weight Kg 71 101
Pipe Connection-Liquid mm 9.5
Pipe Connection-Gas mm 15.9 19.05
Non-Inverter
Work & Servicing Optional
Duct Connection Pre-charged for up to 7.5m Group control by Network Interface Module (NIM)
Standard Static Pressure Type External command control using BAG
Self-Diagnosis
Comfort Wired Remote Controller
Switchable fan speed * Two selectable
Programme “Dry” temperature sensor Control Features Cleanliness Others
Auto random restart Washable Anti-corrosion treated
Timer Selector * Weekly scheduled timer
* Applicable when wired controller is used saranet filter heat exchangers
Indoor Unit FDMRN50AXVL FDMRN60AXVL FDMRN71AXVL FDMRN100AXVL FDMRN125AXVL9 FDMRN140AXVL9
Model Name
Outdoor Unit RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9
Btu/hr 18,500 23,500 29,000 36,000 48,000 56,000
Rated Cooling Capacity (Min. ~ Max.)
kW 5.42 6.89 8.5 10.55 14.07 16.41
Power Consumption Watts 1,730 2,400 3,330 4,000 5,520 6,590
Total Running Current A 7.9 11 15.3 18.2 15.6 19.5
Power Supply Ph/V/Hz 1/220/60 3/220/60
COP W/W 3.13 2.87 2.55 2.64 2.55 2.49
Air Flow Rate
cfm 590/520/320 690/570/440 900/830/640 1250/980/780 1540/1280/1100 1580/1330/1180
(H/M/L)
External Static Pressure Pa 50 100
INDOOR Sound Pressure Level
dBA 40/38/33 42/40/39 47/45/42 50/47/43 51/48/46 52/50/47
(H/M/L)
Dimension (H x W x D) mm 261 x 1,065 x 411 261 x 1,200 x 411 378 x 999 x 541 378 x 1,115 x 541 378 x 1,369 x 541 378 x 1,569 x 541
Machine Weight Kg 24 26 42 44 50 56
Sound Pressure Level dBA 50 57 61 66
Dimension (H x W x D) mm 651 x 855 x 328 753 x 855 x 328 852 x 1030 x 400
OUTDOOR Machine Weight Kg 43 57 71 87 101
Pipe Connection-Liquid mm 6.4 9.5
Pipe Connection-Gas mm 12.7 15.9 19.05
Minimum Piping Length m 3 5
Maximum Piping Length m 30 50
Maximum Piping Elevation m 15 25 30
Chargeless Refrigerant m 7.5
Additional Refrigerant Charge g/m 22 10 30 24 50

Floor Standing Work & Servicing Cleanliness


Comfort Pre-charged for up to 7.5m Washable saranet filter
Horizontal Auto-swing Two selectable Self-Diagnosis
*
Switchable fan speed temperature sensor
Weekly scheduled timer
Control Features Others
Programme “Dry” * Auto random restart
* Applicable when wired controller is used
Anti-corrosion treated
Timer Selector heat exchangers
Indoor Unit FVRN71AXVL FVRN100AXVL FVRN125AXVL9 FVRN140AXVL9
Model Name
Outdoor Unit RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9
Btu/hr 29,000 36,000 48,000 56,000
Rated Cooling Capacity (Min. ~ Max.)
kW 8.5 10.55 14.07 16.41
Power Consumption Watts 3,130 3,800 5,000 6,240
Total Running Current A 13.7 17.3 14.5 18.8
Power Supply Ph/V/Hz 1/220/60 3/220/60
COP W/W 2.72 2.78 2.81 2.63
Air Flow Rate (H/M/L) cfm 675 / 625 / 530 1035 / 945 / 845 1035 / 935 / 835 1170 / 1085 / 985
Sound Pressure Level (H/M/L) dBA 44 / 42 / 39 49 / 47 / 44 50 / 48 / 46 54 / 53 / 51
INDOOR
Dimension (H x W x D) mm 1,850 x 600 x 270 1,850 x 600 x 350
Machine Weight Kg 42 45 48 51
Sound Pressure Level dBA 57 61 66
Dimension (H x W x D) mm 753 x 855 x 328 852 x 1030 x 400
OUTDOOR Machine Weight Kg 57 71 87 101
Pipe Connection-Liquid mm 9.5
Pipe Connection-Gas mm 15.9 19.05
Minimum Piping Length m 3 5
Maximum Piping Length m 50
Maximum Piping Elevation m 25 30
Chargeless Refrigerant m 7.5
Additional Refrigerant Charge g/m 30 30 24 50
Controller
Wireless controller BRC52A62

1 “Glow-in-the-dark” 6 Auto-swing (Not applicable


on / off switch for Suspended type)
1
6 2 Fan speed selection: 7 Selectable mode:
2
7 Low, Medium, High, Auto Cool, Dry, Fan
8 3 3 Temperature setting: 8 Turbo function
9
4 Up & down 9 Quiet function
10 5 4 Sleep mode function 10 On timer setting
11 5 Off timer setting 11 Real time clock

Wired controller BRC51A62


1

1 Real time clock and 6 On / Off Switch


day display
7 Turbo function
2 2 Temperature operate
7 3 8 Cool, Dry, Fan mode
in ˚C and ˚F
8
4 3 Swing function 9 Delay timer (1 or 2 hours)
9
10 5
4 Sleep mode function 10 7-days programmable timer
11 6
5 Sleep function 11 Low, Medium, High,
Auto fan speed

Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra
setting or modification. It also has a built-in temperature sensor that enables temperature sensing closer to
target area for improved comfort (no settings required to activate the handset temperature sensor).

IR receiver on wired handset


received the signal

Signal sent from


wireless handset
Network Controls
Control Pattern Remote Controls

Group control by Network For simultaneous control


Interface Module (NIM) of up to 16 indoor units NIM NIM NIM NIM

Sequential control by For sequential control of


Sequential Network 2 indoor units at alternate
Interface Module (S-NIM) sequence of pre-set hour S-NIM S-NIM

Operation and surveillance


is carried out using the
Control by external contact signal from the
command using BAG operation control box in BAG BAG BAG

the building surveillance


(security) room. BMS

www.daikin.com.ph
Authorized Dealer
Tel No.: (02) 5318 - 6800 | Customer Service: (02) 5318 - 6820

Branches:
ILOCOS Tel No.: (077) 600 - 2720 ILOILO Tel Fax: (033) 323 - 2340
DAGUPAN Tel No.: (075) 615 - 2791 CEBU Tel No.: (032) 348 - 0085
NAGA Tel Fax: (054) 871 - 4177 CDO Tel Fax: (088) 868 - 6800
DAVAO Tel Fax: (082) 285 - 6008

● Specifications, designs, and other content appearing in this brochure are current as of June 2020 but subject to change without notice. DPH-SANINV-062020D
● 1 year warranty for parts and labor | 5 years warranty for compressor only (Labor and Consumables are chargeable after 1 year).

assd_cs@daikin.com.ph Daikin Philippines

You might also like