Professional Documents
Culture Documents
Ltd)
127.563m (418'6")
WICKETOPEN ABLE
GATE TYPE GATE
16.00 MTR RAMP 1:10
8253
7529
4183
RL 99.80
SCISSOR lift
1500
UP 1.5m WALKWA Y 1.5m WALKWA Y 1.5m WALKWA Y
WORKER S RAMP
1.0m WALK WAY W W RS W W 1.0m WALK WAY W RS W 1.0m WALK WAY W ENTRY V
W
RS
550
WALL UP T O S ILL HT
FIRE
1200
ROOM 20SQM
TOILET AREA
33 3 0
EXIT
SECURITY
B B B
VISITORS
B B B B
15 6 0
15 4 0
80 0
26 0
55 0
17 0 0
64 8 8
6450
40 3 0
1500
FFL 101.00
GENERAL NOTES :-
PUMP ROOM
ELECTRICAL
YARD OFFICE AREA 1. MInimum depth of excavation shall
4.00 X 6.40
RAMP UP be 2.0m from ngl
1200 3000 4920 200 200 3000 2. Do not scale the drawings
1500
5000
3. Follow written dimensions only
ELECTRICAL 4. Refer this drawings along with
8000
1.2m WALKWA Y
OPEN ABLE
TYPE GATE
6. Grade of concrete for P.C.C. M-10
7. Grade of steel is FE-500
8. All dimensions are in Mtr
Private Property
1OT CRANE
MD
RL 99.35
RL 100.80 9. Development and lapp length 50xd
GENERATOR
8000
44900 C\C
DOCKING
BAY
12.Clear cover to lintel -20mm
D
13.Clear cover to beam -30mm
RIDGE LINE
V2
WC WC
1.2X 1.7 1.2X 1.7
D1 D1
14.Clear cover to slab -20mm
MAIN BUILDING
V2
FEMALE TOI
OPEN ABLE
TYPE GATE
5.285X2.60
1.2m WALKWA Y
15.Tor indicates dia of steel
62.380m (204'9")
8000
D1
MALE TOILET D
V2
WC
1.2X 1.5 5.285X4.10
16.Seperator rods of 20mm dia between
D1
101.58 X 46.00 FFL 101.00
V2
IW C
1.2X 1.5
RL 99.35 every single layer of steel rods
FFL +1.20MTR
V2
JA NITOR
17.Curtailement length of 150mm.
D1
1.2X 0.90
8000
18.Safe bearing capacity of
Soil KN/m² below existing Ngl
OPEN ABLE
TYPE GATE
FFL 101.00 15000 2.00mtr
8000
1.2m WALKWA Y
19.Foundation should never be rested
on filled up soil.
STORE ROOM
FFL 101.00 RL 99.80 20.If found any discrepancy in drawing
1.20MTR WIDE
15.3 X 5.285m
WICKET
GA TE
V
UR INA LS
DR IV ERS TOILET & WC 1.8 X 1.1
kindly refer to consultant's engineer.
3830 RES T R OOM
4.8 X 2.2m
SECURITY
FFL 101.00
FFL 99.80
6450
1500
ROOM
OPEN ABLE
TYPE GATE
FE MA LE TOILET
2.30X 3.4 0m
GENT S T OILE T
2.35 X 3.40 m
INDEX:
1. WINDOW (W) = 3.00 X 2.0m
550
V V V1
2. VENTILATOR (V) = 1.2 X 0.6M
W DRAIN RS W W W RS W W W DRAIN
1.0m WALK WAY 1.0m WALK WAY FIRE EXIT
DOCKING AREA FIRE EXIT 9802
DOCKING BAY
4500
4097
3. VENTILATOR ( V1) = 0.6 X 0.6m
6.00MTR WIDE
SLIDING
13
RL 100.80
GA TE
2 92 4. VENTILATOR (V2) = 0.9 X 0.6m
RL 99.80 5. MAIN DOOR (D)= 1.2 X 2.1m
CANOPY 5.00MTR W IDE RL 99.80
RL 99.80 6. TOILET DOORS D1= 0.7 X 2.1m
STP
7. ROLLING SHUTTERS =4.5 X 5m (4 No's)
1800
127.363m (417'9")
Change in master plan and
area statement
APPROVED Mr.Dileep
DRAWN Ms.Monica
CHECKED Mr. Dileep
DATE 21-01-2020
SCALE 1:1000
DRG NO SRN/AR-01
TITLE:
MASTER PLAN WITH
AREA STATEMENT
PROJECT:
PROPOSED BUILDING
No-27,2nd Main,Jigani Industrial Area.
Anekal Taluk.
Bangalore-562 106.
CLIENT:
SRINAG
PROJECT CONSLUNTS:-
Dileep Associates
#179/5,1st floor, 2nd Cross,
1st Main, Lower Palace orchards,
Bangalore 560003
Ph: 080-23447176, 41137508.
dileepassociates@rediffmail.com