You are on page 1of 1

100

North Angle: 30.7359°

MATCHLINE
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

3200 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000
Millimetres

C 2600

B 1900 GLB1 150MM THK 150MM THK GLB1 GLB1


(T.O.C) 216.480
8750

GRADE SLAB GRADE SLAB


6150

2950 4550 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4375 4375 4600
10

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1
0

A
GLB1 GLB1 GLB1
50
E.J

20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
MATCHLINE

5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 3200

2600
1900
B
GLB1 150MM THK 150MM THK GLB1
(T.O.C) 216.480

8750
GRADE SLAB GRADE SLAB

6150
4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 4600 2900
GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1

GTB1
A
GLB1 GLB1

1 02_PLINTH LEVEL
11003 1 : 150

GOOD FOR CONSTRUCTION


REFERENCE DRAWINGS: ( ARCHITECTURE) THIS GFC HASBEEN PREPARED BASED ON REV-R00
1. GROUND FLOOR LEVEL PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11101
2. ELEVATION SHEET 1 NCRTC-DM009-AYE-DUHD-IWS-M2-AR-12101
3. ELEVATION SHEET 2 NCRTC-DM009-AYE-DUHD-IWS-M2-AR-12102
4. TERRACE LEVEL PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11111
5. ROOF LEVEL PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11151
6. CROSS SECTION NCRTC-DM009-AYE-DUHD-IWS-M2-AR-13101

REFERENCE DRAWINGS: ( STRUCTURE)


IWS BUILDING
1. FOUNDATION LAYOUT PLAN AND DETAIL NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11001 & 11004 SCHEDULE OF BEAM
2. COLUMN LAYOUT PLAN AND DETAIL NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11002 & 11005
BEAM SIZE DN
DN
DN
3. FOUNDATION AND COLUMN R/F DETAL NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11006,11007 &11008
4. PLINTH LEVEL R/F DETAIL NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11009 BEAM MARK DN
DN
5. FIRST FLOOR FRAMING PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11101. (WIDTH x DEAPTH) DN
DN
DN
6. FIRST FLOOR R/F DETAIL NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11102,11103 & 11104
7. TERRACE FRAMING PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11201 GLB1
400x500 DNDN DN
DN DN
DN
8. TERRACE LEVEL R/F DETAILS NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11202,11203 & 11204 GTB1 DN DN

9. DESIGN REPORT NCRTC-DM009-AYE-DN-ST-00030

DN
DN

NOTES: Certified that this document has been designed and checked in accordance with GC Quality Assurance Plan. Client:
QR CODE APPROVAL BY NCRTC
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS MENTIONED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
NATIONAL CAPITAL REGION
3. ALL DATA RELATED TO PLAN AND PROFILE SHALL BE VERIFIED GF OFFICE, BELOW CWG FLYOVER AT KHEL GAON, NEW DELHI-110092, TRANSPORT CORPORATION
AT SITE AND ANY DISCREPANCY MUST BE BROUGHT TO THE TEL: +91 120 490 8800, EMAIL:DMGC@AIAIGC.COM ,WEBSITE: WWW.AIAIGC.COM
NOTICE OF THE NCRTC BEFORE EXECUTION OF WORK AT SITE. 7/6, Siri Fort Institutional Area, August Kranti Marg, New Delhi – 110049
Senior Discipline Expert Chief Discipline Expert Project Director
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL
RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING & FIRE Project Title:
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS.
5. ALL DOOR/WINDOW CILL & LINTEL LEVELS ARE MEASURED NCRTC RRTS PROJECT -DM-09-DDC
FROM MAIN FLOOR FINISHED LEVELS. Drawing Title: Project Stage:
Certified that this document has been designed and checked in accordance with DDC Quality Assurance Plan.
Designer:
DUHAI DEPOT GFC
INSPECTION & WORKSHOP
PLINTH LEVEL FRAMING PLAN
Paper Size: Discipline: Date: Scale:

G1 25-03-2021 GOOD FOR CONSTRUCTION SAI L.J P.B D-99, 3rd Floor ,Sector 2, Noida - 201301 (U.P) A1 STRUCTURE 25/03/21 As indicated
Designed: Drawn: Checked: Approved: Drawing: Revision:
QR Code allows verification of
REV DATE DESCRIPTION Originator Checked Approved drawings through WRENCH J.K SAI L.J P.B NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11003 G1