You are on page 1of 1

100

North Angle: 30.7359°


N

1' 1 2 3 4 5 6 7 8 9
4000 7500 7500 7500 7500 7500 7500 7500 4000
Millimetres

Not Possible
A
C1A C1 C1 C1 C3 C6 C6 C1 C1 C7

4175 G2
5000
10

C8
0

1975
Not Possible

B
C1A C5 C4A C2A C3A C6 C1A C1A C7
5000

Not Possible Not Possible

C
C1A C4 C1 C1 C3 C6 C6 C1 C1 C7
3100

20-6 Will Increase

D
C1A C1 C4 C4 C3 C3 C3 C1 C2 C2A

16-4 Will Increase


7500

E
C1A C1 C4 C4 C3 C3 C3 C2 C1 C1A

COLUMN LAYOUT PLAN


SCALE 1:100

SCHEDULE OF COLUMN
BASEMENT TO GROUND FLOOR
COLUMN SIZE
COLUMN MARK
L(MM) B(MM)
C1 TO C4 700 600 REFERENCE DRAWINGS: ( ARCHITECTURE)
C1A,C2A,C3A & C4A 600 700
1. BASEMENT LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11101
C6 & C7 500 500 2. GROUND FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11101
C5 600 700 3. FIRST FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11111
4. 2ND FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11121
C8 400 400 G2 5. 3RD FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11121
6. TERRACE LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11131
7. SECTION A-A DM009-AYE-DUHD-ADM-M2-AR-13101
8. SECTION B-B DM009-AYE-DUHD-ADM-M2-AR-13111

REFERENCE DRAWINGS: ( STRUCTURE)


1. COLUMN LAYOUT PLAN DM009-AYE-DUHD-ADM-M2-ST-11001
2. LAYOUT & DIMENSION DETAIL OF RAFT DM009-AYE-DUHD-ADM-M2-ST-11002 & 11003
3. FRAMING PLAN AT GROUND FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11008
4. FRAMING PLAN AT FIRST FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11101
4. FRAMING PLAN AT 3RD FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11301
5. FRAMING PLAN AT TERRACE LVL. DM009-AYE-DUHD-ADM-M2-ST-11401
GOOD FOR CONSTRUCTION 6. GENERAL NOTES DM009-AYE-DUHD-ZZZ-M2-ST-11101 TO 11103
7. DESIGN NOTE NCRTC-DM009-AYE-DN-ST-00007
NOTES: Certified that this document has been designed and checked in accordance with GC Quality Assurance Plan.Client:
QR CODE APPROVAL BY NCRTC
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS MENTIONED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
NATIONAL CAPITAL REGION
3. ANY DISCREPANCY MUST BE BROUGHT TO THE NOTICE OF THE GF OFFICE, BELOW CWG FLYOVER AT KHEL GAON, NEW DELHI-110092, TRANSPORT CORPORATION
NCRTC BEFORE EXECUTION OF WORK AT SITE. TEL: +91 120 490 8800, EMAIL:DMGC@AIAIGC.COM ,WEBSITE: WWW.AIAIGC.COM
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL 7/6, Siri Fort Institutional Area, August Kranti Marg, New Delhi
– 110049
Senior Discipline Expert Chief Discipline Expert Project Director
RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING & FIRE
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS. Project Title:
5. ALL DOOR/WINDOW CILL & LINTEL LEVELS ARE MEASURED NCRTC RRTS PROJECT DM-09-DDC
FROM MAIN FLOOR FINISHED LEVELS.
Drawing Title: Project Stage:
Certified that this document has been designed and checked in accordance with DDC Quality Assurance Plan.
Designer: DUHAI DEPOT-ADMIN BUILDING GFC
COLUMN LAYOUT PLAN
Paper Size: Discipline: Date: Scale:

G1 21-01-2021 GOOD FOR CONSTRUCTION D-99, 3rd Floor ,Sector 2, Noida - 201301 (U.P) A1 STRUCTURE 05/02/21 1 : 100
Designed: Drawn: Checked: Approved: Drawing: Revision:
QR Code allows verification of
REV DATE DESCRIPTION Originator Checked Approved drawings through WRENCH VAMSI DINESH LALIT P.B NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11001 G2