You are on page 1of 1

100

14 16 2-T16
2-T25 17 4-T25
E +2-T20 2000 D 15
C B A 4-T20
E 4-T25 4-T16 D 4-T20
C B A
2000 4-T20 4-T20 1500 2-T16
2-T25 4-T25 2000 2000 800 1250
2-T25 1250 2500

(TYP.)
+2-T20 2500 Ld

(TYP.)

Ld
Ld

(TYP.)
(TYP.)

Ld
Ld
Millimetres

2-T16 2-T16 4-T20 1000 4-T20 4-T16


4-T20 4-T20 500
S1 S1 S1 S3 S1 S1 S1 S1 S3 S1 S1 S1 S1 S7
S1 S3 S1 1200 1200
1200 1200
1200 1200 15 16 17

14
RTB15 (400X600) RTB6 (400X600) RTB7 (400X600) RTB15 (400X600) RTB7 (400X600)
RTB6 (400X600) (GRID D TO C) (GRID C TO A) (GRID E TO D)
SCALE : 1:100
(GRID D TO C)
SCALE : 1:100
(GRID C TO A)
SCALE : 1:100
SCALE : 1:100 SCALE : 1:100
(GRID E TO D)
SCALE : 1:100
10

T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS.
400 400 400 400
21
E 18 4-T16 D 19
C B A E 20
D C B A
0

4-T20 2000 2000


2-T20 2-T16
+2-T16 2000 4-T20 2000 800 1250 4-T20 1250 4-T16 4-T16 2-T20 800 800 1250 2-T16 4-T16

Ld + 10d
(TYP.)

(TYP.)
+2-T16

Ld

Ld + 10d
(TYP.)

(TYP.)
Ld

600

600

600

600
4000 4000
4-T20 4-T20
4-T20 4-T16 2-T20 4-T20 2-T20
+2-T16 +2-T16
S1 S1 S3 S1 S1 S1 S1 S7 S1 S1 S1
S1 S3 S1
1200 1200
18 19 1200 1200
20
21
RTB8 (400X600) RTB15 (400X600) RTB8 (400X600)
(GRID E TO D) (GRID D TO C) (GRID C TO A) RTB9 (400X600) RTB15 (400X600) RTB9 (400X600) SECTION 14-14 SECTION 15-15 SECTION 16-16 SECTION 17-17
SCALE : 1:100 SCALE : 1:100 SCALE : 1:100 (GRID E TO D) (GRID D TO C) (GRID C TO A) SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15
SCALE : 1:100 SCALE : 1:100 SCALE : 1:100

REFER STAIRCASE
24 2-T20 REINFORCEMENT
22 23 2-T20 25 26
E
2-T20
+2-T16
4-T16 D C B A E +2-T16
2000
+2-T16
2000 D C B 2-T20 A E 2000
D 27
C B A
2-T16 +2-T16 4-T20 2000 4-T20 4-T25 1500 4-T16
2000 4-T20 800 1250 2-T16 4-T20 1250 4-T25 4-T16
4-T16 2000 800 4-T20 1250

Ld (TYP.)
Ld + 10d
800 Ld

(TYP.)
(TYP.)
1250

Ld
Ld + 10d

Ld (TYP.)
(TYP.)

(TYP.)

Ld+10d
(TYP.)
Ld
4000 Ld+10d Ld+10d 4000
4-T20 4-T20 Ld Ld 2-T20 2-T20 4-T16 500 2-T20 2-T20
4-T20 4-T20 4-T20 4-T20 +2-T16 500 +2-T16
+2-T16 +2-T16
S1 S3 S1 S1 S1 S1 S3 S1 S1 S1 S1 S1 S1 S1 S3 S1 S1 S1 S1 S1
S1 S1 LIFT WALL
1200 1200 1200 1200 1200 1200
22 23 25 27
24 26

RTB10 (400X600) RTB28 (400X600) RTB29 (400X600) RTB24A (400X850)


(GRID E TO D) (GRID D TO B) (GRID B TO A)
RTB11 (400X600) RTB15A (400X600)
(GRID D TO C) (GRID B TO A) RTB12 (400X600) RTB15 (400X600) RTB12 (400X600)
(GRID E TO D)
SCALE : 1:100 SCALE : 1:100 SCALE : 1:100
SCALE : 1:100
SCALE : 1:100
RTB24 (400X600) SCALE : 1:100 RTB24 (400X600) (GRID E TO D) (GRID D TO C)
SCALE : 1:100
(GRID C TO A)
SCALE : 1:100
SCALE : 1:100
(GRID C TO B) SCALE : 1:100
SCALE : 1:100
30 31
T10 - 2x2 NOS.
E 28
2000
D 29
C B A E 2000 D C B 4-T16 A T10 - 2x2 NOS.
400 400
T10 - 2x2 NOS.
400
4-T20 1200 4-T25 4-T16 4-T16 2-T20 1250
2000 4-T20 2-T16 1250 2000 1250
Ld (TYP.) +2-T16

(TYP.)

(TYP.)
(TYP.)

Ld

Ld
Ld

4-T16 2-T20 500 2-T20


500 4-T16
+2-T16 +2-T16

600

600

600
S1 S1 S3 S1 S1 S1 S3 S1 S1 S1 S1 S1
S7 S1 S1 S1
1200 1200 1200 1200
28 31
29 30

RTB13 (400X600) RTB14 (400X600) RTB15A (400X600) RTB23 (400X600)


RTB15 (400X600) RTB13 (400X600) (GRID D TO C) (GRID C TO A)
(GRID E TO D)
(GRID E TO D)
SCALE : 1:100
(GRID D TO C)
SCALE : 1:100
(GRID C TO A)
SCALE : 1:100 SCALE : 1:100 SCALE : 1:100 SCALE : 1:100 SECTION 18-18 SECTION 19-19 SECTION 20-20
SCALE 1:15 SCALE 1:15 SCALE 1:15

T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS. T10 - 2x2 NOS.
400 400 400 400 400 400 400 400 400 400 400
600
600

600

600

600

600

600

600

600

600

600
SECTION 21-21 SECTION 22-22 SECTION 23-23 SECTION 24-24 SECTION 25-25 SECTION 26-26 SECTION 27-27 SECTION 28-28 SECTION 29-29 SECTION 30-30 SECTION 31-31
SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15

REFER NOTES AND SHEAR REINF. SCHEDULE ON THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
DRAWING NO. NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11404 DRAWING NO. NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11402 & 11404

NOTES: Certified that this document has been designed and checked in accordance with GC Quality Assurance Plan.Client:
QR CODE APPROVAL BY NCRTC
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS MENTIONED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
NATIONAL CAPITAL REGION
3. ALL DATA RELATED TO PLAN PROFILE SHALL BE VERIFIED AT GC OFFICE, BELOW CWG FLYOVER AT KHEL GAON, NEW DELHI-110092, TRANSPORT CORPORATION
SITE.ANY DISCREPANCY MUST BE BROUGHT TO THE NOTICE OF TEL: +91 120 490 8800, EMAIL:DMGC@AIAIGC.COM ,WEBSITE: WWW.AIAIGC.COM
THE NCRTC BEFORE EXECUTION OF WORK AT SITE. Senior Discipline Expert Chief Discipline Expert Project Director 7/6, Siri Fort Institutional Area, August Kranti Marg, New Delhi
– 110049
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL
Project Title:
RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING & FIRE
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS. NCRTC RRTS PROJECT DM-09-DDC
5. ALL DOOR/WINDOW CILL & LINTEL LEVELS ARE MEASURED
FROM MAIN FLOOR FINISHED LEVELS. Drawing Title: Project Stage:
Certified that this document has been designed and checked in accordance with DDC Quality Assurance Plan. DUHAI DEPOT-ADMIN BUILDING CRD
Designer:
REINFORCEMENT DETAIL OF BEAM
AT TERRACE FLOOR LVL.
Paper Size: Discipline: Date: Scale:

R00 15-07-2021 FIRST SUBMISSION D.R L.J P.B D-99, 3rd Floor ,Sector 2, Noida - 201301 (U.P) A1 STRUCTURE 15/07/2021 AS SHOWN
Designed: Drawn: Checked: Approved: Drawing: Revision:
QR Code allows verification of
REV DATE DESCRIPTION Originator Checked Approved drawings through WRENCH M.Z D.R L.J P.B NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11403 R0

You might also like