You are on page 1of 1

4000 3000 4700 2300 4000

F2-C2 F2-C2 F2-C2 F2-C2 F2-C2


FFL
C1 = 300mm X 300mm

150
ON FILL

3000

3000
MAIN BARS 8 - 16mm Ø

(1),(2) 10mmØ - 2@50mm,

600
F2-C2 F2-C2 F2-C2 F2-C2 F2-C2
LINKS 2@100mm, REST@175
ON FILL
2500

2500
04 COLUMN DETAIL
F2-C2 F2-C2
F1-C1 F1-C1
F2-C2 F2-C2
S6 SCALE 1:20

100mm THICK GRAVEL BED EARTH


3000

3000
WELL COMPACTED
1200

1200
ELEV = 0.20M

4" CONCRETE SLAB ON FILL 300


TYPICAL Ø10mm TIES SPACED 2 @ 50mm, 4@
F2-C2 F2-C2
F1-C1 F1-C1 100mm, 4@ 150mm, REST @ 200mm
10MM TEMP BARS @ 0.50M
O.C. BOTHWAYS (TYPICAL) 6 - Ø16mm VERTICAL BARS
3000

3000
Ø16mm HORIZONTAL BARS

250
F2-C2 F2-C2 F2-C2 F2-C2
F1-C1 F1-C1

1200
300
1500
F2-C2 F2-C2 F2-C2

PLANTED COLUMNS C1F1


4000 2000 6000 2000 4000
5-16MMØ BASEBARS SPACED
EQUALLY, OC, BOTHWAYS.

01 FOUNDATION PLAN PLAN OF C1F1


03 SECTION OF C1F1 05
S6 SCALE 1:100
S6 SCALE 1:20
S6 SCALE 1:20

3000 4700 2300 4000

C2 B1 C2 B1 C2 B1 C2 B1 C2

ONE WAY SLAB SCHEDULE

3000
3000

S1 100mm THK SUPPORT MIDSPAN SUPPORT

C2 B1 C2 B1 C2 B1 C2 B1 C2
A. SHORT SPAN
MIDDLE STRIP 200mm 200mm 200mm
COLUMN STRIP 200mm 200mm 200mm 6" CONC. HOLLOW BLOCKS W/ Ø10mm
2500

2500
450 BARS @ 3 LAYERS BOTHWAYS
B. LONG SPAN CEM. PLASTER FIN.
MARIWASA CERAMIC TILES FLR. LN.
150
MIDDLE STRIP 200mm 200mm 200mm FIN. GR. LINE Ø10mm TEMP BARS @ 0.50
C2 C1 B1 C1 B1 C2 B1 C2 COLUMN STRIP 200mm 200mm 200mm OC BW.

USE 12mmØ DSB


4" CONC. SLAB
3000

3000
4" GRAVEL
6" CONC. HOLLOW BLOCKS W/ Ø10mm

600
TWO WAY SLAB SCHEDULE BARS @ 3 LAYERS BOTHWAYS

C1 B1 C1 B1 C2 B1 C2 CEM. PLASTER FIN. EARTH FILL


S1 100mm THK SUPPORT MIDSPAN SUPPORT

A. SHORT SPAN (MAIN BAR) = 12mmØ DSB

300
3000

3000

3 - Ø12mm CONTINUOUS BARS


MIDDLE STRIP 200mm 200mm 200mm Ø10mm TRANSVERSE BARS
@ 0.30m. O.C.
COLUMN STRIP 200mm 200mm 200mm

200
CLASS A CONC. FOOTING
C2 C1 B1 C1 B1 C2 B1 C2 B. LONG SPAN (TEMPERATURE BARS) = 12mmØ DSB CLASS A CONC. FOOTING

MIDDLE STRIP 200mm 200mm 200mm PLAN


1500

3 - Ø12mm CONTINUOUS BARS


COLUMN STRIP 200mm 200mm 200mm
ELEVATION

2000 6000 2000 4000 06 WALL FOOTING DETAIL


07 SLAB DETAILS S6 SCALE 1:20
S6 NOT DRAWN TO SCALE

02 SECOND FLOOR FRAMING PLAN


S6 SCALE 1:100

PROJECT TITLE: REPUBLIC ACT 545 SECTION 25(4) PROJECT TITLE: PROJECT OWNER: SHEET CONTENTS: REMARKS: SHEET NO.:
JOMARI KAISER M. BERMIDO Drawing and Specification duly signed,stamped or
sealed as instrument of service are properties of the
FOUNDATION PLAN Designed By:
SECOND FLOOR FRAMING PLAN
ARCHITECT Author whether the object for which they are madeis CAD By:
BICOL UNIVERSITY PROPOSED: SECTION OF C1F1
INSTITUTE OF DESIGN AND ARCHITECTURE
PRC No. Validity
executed or not .It is unlawful for any person, without
the writter consent of the author of the said document to
duplicate or copy for use in other projects, whether
TWO (2) STOREY RESIDENTIAL BUILDING JOSEPH D. BERMIDO PLAN OF C1F1 Approved By: S-06
IAPOA No. O.R No. Date SLAB DETAILS
LEGAZPI CITY executed partly or in whole Date: August 2022
PTR No. Date. WALL FOOTING DETAIL
Place: TIN. LOCATION : NAPOVILLE SUBDIVISION, BRGY NAPO POLANGUI, ALBAY Project No.: