You are on page 1of 1

100

37 36 35 34 33 32 31 30
1 2 3 4 5 6 7 8
MATCH LINE -1
1 2
Millimetres

4-T20 4-T20
1000 4-T20 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250
Ld + 10d

1000
(TYP.)

4-T16
4-T20 4-T20

S2 S3 S2 S2 S4 S2 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1
10

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1 2 GLB1 (400X500)
0

SCALE : 1:50

30 29 28 27 26 25 24 23
8 9 10 11 12 13 14 15
MATCH LINE -1 MATCH LINE -2

1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250 4-T20 1250 1250

4-T20

S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

GLB1 (400X500)
SCALE : 1:50

23 22 21 20 19
15 16 17 18 4 19
MATCH LINE -2
3 SCHEDULE OF SHEAR REINF.
4-T20 4L 8Ø @100C/C
4-T20 4-T20 4-T20 4-T20 1250 S1

Ld + 10d
1250 1250 1250 1250 1250 1250 1250 1250

(TYP.)
S2 4L 8Ø @95C/C

4-T20 4L 8Ø @150C/C
S3

S4 4L 8Ø @200C/C
S1 S1 S4 S1 S1 S4 S1 S1 S4 S1 S1 S4 S1
1000 1000 1000 1000 1000 1000 1000 1000 1000
3 4
GLB1 (400X500) GOOD FOR CONSTRUCTION
THIS GFC HAS BEEN PREPARED BASED ON REV-R00
SCALE : 1:50

REFERENCE DRAWINGS: ( ARCHITECTURE)


1. GROUND FLOOR LEVEL PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11101
2. ELEVATION SHEET 1 NCRTC-DM009-AYE-DUHD-IWS-M2-AR-12101
B A 3. ELEVATION SHEET 2
4. TERRACE LEVEL PLAN
NCRTC-DM009-AYE-DUHD-IWS-M2-AR-12102
NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11111
5 6 5. ROOF LEVEL PLAN NCRTC-DM009-AYE-DUHD-IWS-M2-AR-11151
4-10Ø 4-10Ø 4-10Ø 4-10Ø 4-10Ø 6. CROSS SECTION NCRTC-DM009-AYE-DUHD-IWS-M2-AR-13101
4-T20 4-10Ø
4-T25 400 400 400 400 400
1500 4-T25 400
1500
Ld + 10d

NOTES :-
Ld + 10d

4-20Ø 4-20Ø 4-20Ø 4-20Ø 4-20Ø


(TYP.)
(TYP.)

4-20Ø

1. GRADE OF CONCRETE - M25


4-20Ø 4-20Ø 4-20Ø 4-25Ø
500

2. MINIMUM CLEAR COVER TO SHEAR LINK REINFORCEMENT SHALL BE 30MM


500

500

500

500
2-T25 3. ALL T.M.T REINFORCEMENT BARS CONFORM TO IS:1786 GRADE Fe-500D

500
S2 S4 S1 S1 S1
+2-T20 S4 4. DEVELOPMENT LENGTH (Ld) SHALL BE 50 TIMES DIA. OF BAR
4-16Ø
S1 S4 S1 5. LAP LENGTH SHALL BE 1.4xLd. NOT MORE THAN 50% OF THE BARS SHALL BE
1000 1000 LAPPED AT ANY SECTION UNLESS OTHERWISE SPECIFIED. SPACING OF
4-20Ø 4-20Ø 4-20Ø 4-20Ø 2-25Ø+2-20Ø STIRRUP OVERLAP LENGTH SHOULD NOT BE MORE THAN 150 MM C/C.
2-25Ø +2-20Ø
5 6 6. ALL STRUCTURAL DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT
GTB1 (400X500) ARCHITECTURAL DRAWINGS.

SCALE : 1:50 SECTION 1-1 SECTION 2-2 SECTION 3-3 SECTION 4-4 SECTION 5-5 SECTION 6-6 7. HIGHER GRADE OF CONCRETE TO BE POURED AT BEAM / COLUMN JUNCTION.
SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 SCALE 1:15 8. HIGHER DIA OF BAR TO BE USED AS SPACER BAR.

NOTES: Certified that this document has been designed and checked in accordance with GC Quality Assurance Plan.Client:
QR CODE APPROVAL BY NCRTC
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS MENTIONED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
NATIONAL CAPITAL REGION
3. ANY DISCREPANCY MUST BE BROUGHT TO THE NOTICE OF THE GC OFFICE, BELOW CWG FLYOVER AT KHEL GAON, NEW DELHI-110092, TRANSPORT CORPORATION
NCRTC BEFORE EXECUTION OF WORK AT SITE. TEL: +91 120 490 8800, EMAIL:DMGC@AIAIGC.COM ,WEBSITE: WWW.AIAIGC.COM
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL 7/6, Siri Fort Institutional Area, August Kranti Marg, New Delhi
– 110049
Senior Discipline Expert Chief Discipline Expert Project Director
RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING & FIRE
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS. Project Title:
5. ALL DOOR/WINDOW CILL & LINTEL LEVELS ARE MEASURED NCRTC RRTS PROJECT DM-09-DDC
FROM MAIN FLOOR FINISHED LEVELS.
Drawing Title: Project Stage:
Certified that this document has been designed and checked in accordance with DDC Quality Assurance Plan. DUHAI DEPOT-INSPECTION & WORKSHOP GFC
Designer:
BUILDING REINFORCEMENT DETAIL OF
BEAM AT GROUND FLOOR LVL.
Paper Size: Discipline: Date: Scale:

G1 26-03-2021 GOOD FOR CONSTRUCTION D.R L.J P.B D-99, 3rd Floor ,Sector 2, Noida - 201301 (U.P) A1 STRUCTURE 26-03-2021 AS SHOWN
Designed: Drawn: Checked: Approved: Drawing: Revision:
QR Code allows verification of
REV DATE DESCRIPTION Originator Checked Approved drawings through WRENCH A.Y D.R L.J P.B NCRTC-DM009-AYE-DUHD-IWS-M2-ST-11009 G1

You might also like