The use of this arrangement may be subject to a risk assessment c) Concrete for foundations to have a min. 28 day characteristic
being carried out to the satisfaction of the overseeing organisation, strength of 20MPa for Ø150x300mm cylinder or 25MPa for
150mm cube test, prior to the VRS being commissioned.
based on its specific site use and layout. The impact performance of CM091
the adjacent structure/VRS and the end (A1 post) of the All joints to be podgered d) For further details of our systems, please go to our website
non-connecting transition is critical. as beams are installed as listed below.
This drawing is Copyright © of Hill & Smith Ltd and protected under UK and International law. All rights reserved. This drawing may not be copied
35
='S' Note: X-X axis is perpendicular to the longitudinal run of the barrier
direction of traffic flow 220 270
x x Nominal tensile load Moment of Coexistent shear load
320
RHS-47-1-26 about x-x axis resistance about about x-x axis
120 85 170 85
125
160
M20 Form E Washer (per pair of anchors) x-x axis (per post) (per post)
0.02 kg 114 kN 26 kN.m 87 kN (std height post) Traffic Face
305
Traffic Face
Surface Mounted Type 1 Transition Post - S355
230 8mm
35
Note: X-X axis is perpendicular to the longitudinal run of the barrier
A21A M16x130-8.8-GALV
Nominal
Nominal
M20x40 Screw 0.2 kg CM057S or Z A
(See Note g)
(See Note g)
Reinforcing Ring B128 Bolt Assembly M16x130 x x
610 `30
610 `30
(Torque 60-80Nm) Socket Excluder Nominal tensile load Moment of Coexistent shear load
320
0.5 kg Clamp Strap 0.6 kg gr8.8 cw gr10 Nut & about x-x axis resistance about about x-x axis
0.1 kg
125
Surface Mounted Posts
160
(per pair of anchors) x-x axis (per post) (per post)
2 No.Form F Washers
(170x47.5x6)
0.31 kg mm Kgs 150 kN 35.5 kN.m 117 kN (std height post)
Item No. 305
(Tourque 60-80Nm) Note: X-X axis is perpendicular to the longitudinal run of the barrier Post Assembly A & B Post Assembly C
49
x x Setting Out Setting Out
340
259
Nominal tensile load Moment of Coexistent shear load
129.5
about x-x axis resistance about about x-x axis
170
CM091 (per pair of anchors) x-x axis (per post) (per post) General System Dimensions
6mm
HS F07DSH 110
Beam Front Transition Anchor 2.0m Nom, 25.6 kg Thk Foot
96 kN 28.9 kN.m 47 kN (std height post)
M16x30 Joint Bolt Assembly 220
abcde
0.14 kg
N2 FlexBeam PLUS 170 x 47.5 x 6 mm 'Z' Post - Steel Grade S355
(Tourque 60-80Nm) 47.5
Springvale Business & Industrial Park
Elastic Plastic
Detail B Y Sect.
Ixx Iyy ryy Bilston, Wolverhampton, WV14 0QL.
B area Zxx Zyy Zxx Zyy
cm⁴ cm⁴ cm
cm² cm³ cm³ cm³ cm³
x x
170
Assesment review ref: 1216180-01
CM052 14.79 530.6 26 62 10.9 81 16.9 1.33 Review Body- HORIBA MIRA certification LTO
6
M10x35 ScrewAssembly CM090 Y