Professional Documents
Culture Documents
it is the sole
responsibility of the
chief engineer to
a gas mask suitable ascertain that all
for protection against members of the
each refrigerant engineering
used, or a self department are
contained breathing familiar with the use
On all vessels equipped with refrigeration units of apparatus must be of gas masks or
11 14 A over 20 cubic foot capacity, __________. provided breathing apparatus
Compressed,
A portion of the cargo of an LNG carrier boils off condensed, and
during each voyage. How is the cargo boil off return to the cargo Vented to the
11 15 C normally handled? tanks. atmosphere.
Air leaking into a flash type distilling plant could
11 16 D occur through __________. gasketed joints valve stems
The construction portfolio may be included as part
11 17 B of the MODU __________. general plans operating manual
Direction of flow
through the valve
Which of the following statements represents the Direction of flow depends upon the
proper relative direction of flow through a globe through the valve is type of seat design
11 18 C valve? unimportant. used in the valve.
Vertical partitions providing strength and
compartmentation on a MODU are called
11 19 B __________. decks bulkheads
The shaded portion of the diagram shown in the
11 20 A illustration represents a __________. discharge manifold suction line
The illustrated drawing shows a correct front "F"
and top "T" view of an object. Of the views
labeled "1","2","3", and "4", the one that correctly
represents the right side view for a third angle
11 21 B projection is __________. 1 2
Which of the listed types steam traps operates on
the principle that hot water flashes to steam when
11 22 D its vapor pressure is rapidly reduced? Ball float Thermostatic
The lathe tool shown as "Q" in the illustration is a left hand side facing
11 23 B __________. cutting-off tool tool
The heat gained per pound of refrigerant in the latent heat of
11 24 C evaporator is known as the __________. vaporization sensible heat
A squealing sound occurring from within an
operating reciprocating air compressor is an
11 25 C indication of __________. compressor overload motor overload
A mooring winch should be equipped with half the breaking the full breaking
mechanical brakes capable of holding strength of the strength of the
11 26 B __________. mooring line mooring line
The requirements for special welding procedures
to be used on a MODU must be contained in the
11 27 C __________. vessel plans Coast Guard file
thermodynamic
thermostatic bellows impulse type steam
11 28 A The trap illustrated operates as a __________. type steam trap trap
Bulkheads forming part of the tanks on a MODU deck loads from dynamic forces while
11 29 C are stiffened to withstand __________. above afloat
Vapor pockets
Which of the listed conditions can lead to formed in the suction Rough casing volute
11 42 A cavitations in a centrifugal pump? flow stream. surfaces.
chemical and
For MODU's operating under the U.S. flag, the detailed construction physical properties of
11 62 C construction portfolio must contain __________. plans ABS approved steels
The lathe tool shown as figure "B" in the right hand roughing
11 63 C illustration is called a __________. tool cutting-off tool
When liquid reaches the compressor of a
refrigeration system through the suction line, the
11 64 A condition is called __________. flooding back superheating
In the illustration, item "5" represents a
11 65 D __________. diaphragm pump rotating vane pump
The term 'pour point' is defined as the lowest
temperature at which lubricating oils will flow
11 66 B __________. rapidly by gravity
The master or person in charge of a MODU is the date and hour of the names of all
11 85 A required to log __________. each fire drill persons on board
In a radial piston pump, reversal and control of
fluid flow are accomplished by moving the
11 86 C __________. central valve radial plunger
The condition of all
fire fighting
equipment, watertight
What must be entered in the unofficial logbook by door mechanisms, The location of the
the master or person in charge of a mobile and valves used unit at the time each
11 87 A offshore drilling unit after conducting a fire drill? during each drill. drill is conducted.
the length of time
the names of crew that each motor
members who propelled lifeboat
After conducting a boat drill, the master or person participated in the was operated in the
11 88 B in charge of MODU shall log __________. drill drill
The deck loads on a MODU are distributed
11 89 A through the deck beams to the __________. frames hull
a lower outlet
The dual pressure-temperature regulator, shown pressure, with a
in the illustration, is adjusted by turning the stem a higher outlet corresponding
"L" clockwise (as viewed from the top) and the pressure, with a decrease in the
adjusting ring "B" counterclockwise (as viewed higher controlled fluid controlled fluid outlet
11 105 A from the top). This will result in __________. outlet temperature temperature
Regarding the oil cooler shown in the illustration, allow the water to allow the oil to make
the purpose of the internal shell baffles is to make four passes four passes over the
11 140 B __________. over the tubes tubes
In the pump shown in the illustration, what is the
distance from the bottom of the inlet to the bottom
11 141 D end of the motor shaft? 45 1/4 inches 45 5/16 inches
stuffing boxes
eliminate the leakage it is not necessary to
problems usually closely maintain
Positive displacement, helical gear pumps are well associated with other design clearances
11 146 C suited for pumping oil because __________. gear pumps with this pump
The conical steel or composition cone installed on
a propeller, known as a fairwater cone, provides
11 147 A which of the following benefits? Reduce turbulence Help with lubrication
They can be
They make it easier economically
Why are removable sleeves installed on to replace the pump replaced as they
11 149 B centrifugal pump shafts? shaft packing. wear out.
In order for the reducing valve, shown in the the underside of
illustration, to properly function, a control port is diaphragm "E" and the inlet side and the
11 150 A utilized between __________. the outlet outlet side
A good quality oil used in main propulsion engine free from all chemical quickly chemically
11 153 C lubrication systems should be __________. additives oxidized
When air at a given temperature, contains the
maximum amount of moisture for that
11 154 B temperature, the air is said to be __________. superheated saturated
Which type of space heating systems is shown in Circulated hot water
11 155 A the illustration? Steam heating heating
Which of the listed types of pumps is NOT likely to
be installed in a main drainage or evacuation
11 156 C system? Reciprocating pump Centrifugal pump
In a compression type automatic grease cup, the
lubricant is forced into the bearing by
11 158 B __________. gravity flow spring force
The valve shown in the illustration uses port "J" to open the auxiliary
11 160 D __________. valve open the main valve
In the illustration shown, the notation 1/8"R recess on one end of rough finish on both
11 161 D indicates a one-eighth inch __________. the tool ends of the tool
Water hammer in a steam heating system can be filling the auxiliary steam admitted to a
11 167 B caused by __________. boiler with cold water cold pipe
so as to never be
Main propulsion engine lube oil sumps should be integral with the main
11 168 B constructed __________. engine foundation with a sloped bottom
Excessive leakage and premature failure of valve opening a valve too jamming a valve in
11 177 D packing is a result of __________. quickly the closed position
Which of the following problems may be
encountered by using an oil having a viscosity
higher than that specified for an operating External seal Hunting due to fast
11 178 D hydraulic system? leakage. response.
Water leaking from a pump packing gland is kept
away from the bearing housing by the use of
11 179 C __________. shaft sleeves lantern rings
Before the longitudinal carriage feed of a lathe is spindle clutch is carriage clamp screw
11 187 B engaged, you must be certain the __________. disengaged is loosened
Increasing the speed of a rotary pump above its
rated speed will result in which of the following
11 188 B conditions to occur? Loss of suction Increased clearances
maintain even
distribution of bearing maintain a constant
11 189 C The function of lubricating oil is to __________. wear oil temperature
If a drill press is used to completely bore through the drill bit from
a metal plate, feed pressure on the drill bit should jamming and
be eased as the bit breaks through the bottom of spinning the drilling undersized
11 196 A the hole to prevent __________. workpiece holes
To allow repair or
replacement of the
Which of the following statements describes the To serve as a seal primary seal
purpose of the split inflatable seal installed aft of when adding packing elements when the
11 197 B the primary seal assembly for the propeller shaft? to the stuffing box. ship is waterborne.
Why should a person who is performing
maintenance on an air compressor, wire and tag To prevent the To protect the
11 198 D the system valves closed? unexpected. equipment.
With regard to the opening and closing of
watertight appliances not fitted with a remote
operating control or alarm system, which of the The reason for
following is the master or person in charge of a The time required to opening or closing
11 199 B MODU required to enter in the logbook? close the appliances. each appliance.
At which of the following locations would a duplex Fuel oil service pump
11 208 B pressure gage most likely be located? discharge flange Fuel oil strainer
The gear teeth are
Why is the discharge pressure of a herringbone Clearance between smaller than those of
gear pump steadier than the discharge pressure the gear teeth and the simple spur gear
11 209 C of a simple spur gear pump? casing is smaller. pump.
The part labeled "B" of the illustrated bearing is
11 210 B called the __________. thrust ring outer race
Which of the following actions, pertaining to
saltwater lubricated stern tube stuffing boxes, is
usually observed when the ship is expected to be The stuffing box is The drain connection
11 211 C in port for an extended period? continually flushed. is left opened.
A bourdon tube-type steam pressure gage is fitted
with a siphon loop to prevent damage from extreme thermal the admission of
11 212 A __________. stress condensate
The thread form shown in the illustration is called
11 213 C a/an __________. Whitworth thread Square thread
Provide either a
common or individual
Provide constant reducing station for
Which of the following guidelines is considered to steam service for each group of units
reflect good design practices of shipboard steam equipment operating requiring the same
11 243 D heating systems? throughout the year. operating pressure.
The heat required to change a substance from a
liquid to a gas without experiencing a
temperature change, is defined as the latent heat
11 244 B of __________. fusion vaporization
The average density of brine discharged from the
last stage of a fresh water evaporator should not
11 245 B exceed __________. 1.0/32nds 1.5/32nds
discharge end being
A distinguishing feature of an eductor, when smaller than the
11 246 C compared to other pumps, is the __________. suction end small size of impeller
While at normal sea speed the rudder movement
stops, but is restored after changing over power
units. At the earliest opportunity the faulty power
unit is restarted with the following results: the
rudder can be remotely swung in only one
direction, however using the trick wheel equal
movement of the variable stroke control device either solenoid coil
from neutral is available. The probable cause is only the solenoid coil 'F1' or 'F3' has
11 247 B __________. 'F2' has burned out burned out
When securing a flash-type evaporator for an fill the unit with fill the unit with
11 248 C extended period of time, you should __________. saltwater descaling compound
The portion of a hydraulic hose that determines its
11 249 B overall strength, is the __________. inner tube braided inner layer(s)
Close radial
Which features of a centrifugal pump reduce the clearance between
need for renewing worn impellers and pump impeller hub and Low rotational speed
11 250 D casings? casing of impeller
A centrifugal pump may fail to deliver water when water seal pipe is
11 251 B first started if the __________. plugged pump is not primed
A weight of 1,000 kips is equivalent to
11 252 D __________. 1,000 pounds 2,000 short tons
Which of the devices listed is common to all types A power end and A propeller and
11 253 A of pumps? fluid end educator
Heat which brings about a change in the physical
state of a substance without a change in
11 254 C temperature, is called __________. specific heat sensible heat
The hulls of most modern towing vessels
constructed today are fabricated from
11 255 C __________. wrought iron high alloy steel
Gate valves should not be used for throttling as the pressure drop will air binding will
11 279 D __________. be excessive develop
To finish tapping a blind hole, it is best to use a
11 280 C __________. taper tap finishing tap
The purpose of an air compressor unloading drain water from the drain water from the
11 283 C device is to __________. air receiver cylinders
Distillation is the
process of boiling Evaporation is the
seawater to produce second part of the
vapor which is distillation process
Which of the following statements is correct condensed into fresh where brine is
11 288 A relative to distillation plant operation? water. removed.
A leaking steam trap located in the return lines
from a heating system is indicated by excessive scale returning from
11 289 A __________. drain tank steaming the convectors
The minimum length of dimension "C" shown in
11 290 D the illustration is __________. 27/32 inch 11/16 inch
If a centrifugal pump is driven by a constant speed
electric motor and produces a discharge pressure
less than designed, the cause is probably excessive pump excessive suction
11 291 C __________. speed head
a small self-
contained forced
The bearings for the illustrated pump are feed pressurized oil
11 293 C lubricated by __________. system packed grease
The ratio of the weight of moisture contained in a
given volume of air, to the weight of moisture that
the same sample would hold if saturated, is called
11 294 B the __________. absolute humidity relative humidity
Which of the listed chemicals can be routinely
used to maintain the hygienic quality of potable
11 295 B water? Hydrochloric acid Chlorine
The inner race The outer race
Which of the following statements concerning should be free to turn should be free to turn
11 296 D antifriction bearings installed on pumps is true? on the shaft. its housing.
The steam coils in a high pressure evaporator
used for saltwater service should be descaled with
11 297 C __________. a needle gun soap and water
The packing installed in the pump stuffing box is gravity and feed oil
11 298 D normally lubricated by __________. cups grease cups
The included angle of the chamfer in the knurled
portion of the tube sizing tool illustration is
11 301 D __________. 5° 10°
A lathe dog, fitted with a headless set screw, is
11 303 C known as a __________. clamp lathe dog standard lathe dog
The moisture sensitive element of a humidistat
11 304 A can be made of __________. hair copper
Brass pipe is
Stainless steel pipe manufactured in
Which of the following statements is correct is manufactured in three common
11 312 C regarding grades of pipe? four general grades. grades.
When replacing ball bearings on an electric motor tap the outer race apply even pressure
11 318 C shaft, you should __________. with a mallet to the outer race
The pump packing gland has been repeatedly
tightened by small increments until the gland has
bottomed. Which of the actions listed should be Replace with larger
carried out next if the leakage continues to be Replace all of the cross-sectional turns
11 319 D excessive? packing. of packing.
Copper is sometimes used for fluid power lines has good resistance has high resistance
11 320 B because it __________. to high temperatures to corrosion
After installing a new hydraulic pump in a system, The relief valves in The filters and
what special attention should be given to the the system should be strainers should be
11 330 B hydraulic system? readjusted. checked frequently.
A pounding noise occurring in one cylinder of a lower than normal lower than normal
steam reciprocating general service pump could supply steam supply steam
11 331 C be caused by __________. temperature pressure
do nothing, this is a
close sliding fit but
there is no way to
the piece with the make it a locational
hole must be heated interferance fit and a
To make the pieces shown as "A" in the until the inside close sliding fit is an
illustration a locational interference fit diameter of the hole acceptable
11 379 C __________. is .245 inches +/-.001 alternative
prevent the control
The function of the hydraulic telemotor transmitter transmit the rudder linkage from striking
used in an electro-hydraulic steering gear system angle to the bridge the stops when hard
11 380 D is to __________. indicator over
The diameter of a hole drilled for tapping threads larger than the tap smaller than the tap
11 386 B into a piece of stock should be __________. diameter diameter
Lint from cleaning rags can be harmful to can cause rusting of breaks down
11 390 C hydraulic systems because the lint __________. internal parts hydraulic fluid
variable
In the hydraulic transmission shown in the low pressure displacement
11 391 D illustration, the "B" end is a __________. hydraulic pump hydraulic pump
use the same wetting
oil on the element as install a smaller size
An important point of consideration when is used in the filter to allow for
replacing a dry type intake filter on an air compressor expansion of the
11 392 D compressor is to __________. lubrication system element
A refrigeration system contaminated with moisture
11 393 D can be affected by __________. acid formation sludge formation
stored at
Some chlorinated fluorocarbon refrigerants may temperatures below charged into a
decompose into a toxic irritating gas if it is 60 degrees system having
11 394 D __________. Fahrenheit copper fittings
Failing to decrease the feed pressure on a drill as break cleanly through cut an elongated hole
its point begins to break through the bottom of the the bottom of the in the bottom of the
11 413 D work piece will cause the drill to __________. workpiece workpiece
The relief valve
Coast Guard Regulations (46 CFR) require a The relief valve from settings shall be 1
method for the relief of an over pressurized the receiver must 1/4 times the
refrigeration system. Which of the following relieve to the maximum allowable
11 414 C statements complies with these regulations? condenser first. working pressure.
Air leakage between the shaft and stuffing box
packing in a centrifugal pump is prevented by a compressed lantern rings between
11 415 C __________. packing gland the packing rings
The suction-force principle of operation is a typical
11 416 D characteristic of __________. centrifugal pumps jet pumps
In an automation system, increasing or
decreasing the loading pressure by a set amount
11 418 C is known as __________. positioning proportioning
pneumercator
balance chamber
pneumercator is bleed orifice is
A fuel oil tank pneumercator will give an recharged with the blocked by the oil
11 419 B inaccurate reading if the __________. air supply open being measured
Hydraulic pumps most commonly used in steering
11 421 C systems are of the __________. lobe type screw type
Fittings used to close the ends of pipe are called
11 422 A 'pipe _____________'. caps ells
When drilling blind holes with a standard drill
press, the proper method of stopping the progress
of the drill boring through the work is by moving the working
11 423 B __________. table using a depth stop
In a direct expansion type multi-box refrigeration
system, the compressor is set up to cycle on and
11 424 D off by the __________. pressurestat high pressure cutout
Provides a positive
Which of the following statements describes the Protects against pressure on the air
11 485 D function of an air compressor intake filter? suction valve float. inlet valves.
A salinity indicating system functions on the basic electrical inductance electrical conductivity
11 488 B principle of measuring the __________. of water of water
In ship construction, the shell plating is arranged
in strakes, with four of the strakes being
specifically identified by name. The strake next to
11 489 B the keel is identified as the __________. keel strake garboard strake
The number of screw threads per inch for a
Standard National Coarse 1/2 inch bolt is
11 490 A __________. 13 16
In the steering gear system shown in the
illustration, if the maximum working pressure is
applied to the face of the ram, the total force on
11 491 A one piston will be __________. 209,230 lbs 836,920 lbs
After conducting a boat drill on a mobile offshore
drilling unit, which of the following is the master or The condition of the The name of the
person in charge required to enter into the equipment used lifeboatman in charge
11 492 A logbook? during the drill. of each lifeboat.
freeze on the
expansion valve seat
and reduce the flow emulsify the oil in the
11 514 A Moisture in the refrigerant may __________. of liquid refrigerant condenser
Component "B" is
During the operation of the device shown in the closed and will open Component "D" is
illustration, the required compressed air output when output open and will close
has stabilized within a pressure range of 100-110 pressure had when output
psi. Which of the following statements of operating dropped below 50 pressure rises above
11 547 D conditions is correct? psi. 110 psi.
The process of grinding, shredding, or reducing
the size of sewage particles is known as
11 548 B __________. detension maceration
sufficient capacity to
contain all the lube
oil in the system
installation of baffles except for the
Design characteristics of lubricating oil sump to prevent excessive contents of the
11 561 A tanks will include __________. sloshing of oil gravity tank
high temperature
One distinct advantage of flash type evaporators, distillate can be
as compared to most other evaporators, is that in recirculated to induce scale formation is not
11 577 B a flash evaporator shell __________. additional flashing a severe problem
A hacksaw blade is normally placed in the saw maximum possible teeth pointing away
11 582 B frame with the __________. tension on the blade from the handle
Dual electro-hydraulic steering units usually with both pumps on with one pump on
11 583 B operate __________. line at the same time standby
If a liquid sight flow indicator in a refrigeration
system shows gas bubbles in motion passing too much refrigerant oil entrained in the
11 584 C inside of the glass, there is __________. in the system refrigerant
Diamond point chisels are best used for cutting oil grooves in V-grooves and inside
11 586 B __________. bearings sharp angles
In ship construction, the hull frame members
11 589 D extending athwart ship are called __________. deck frames stringer frames
To properly install a new blade in a hand hacksaw teeth should point teeth should point
11 592 B frame, the __________. toward the handle away from the handle
If one hydraulic pump of an electro-hydraulic
steering unit fails, the vessel's steering can be
11 593 C maintained by using the __________. trick wheel accumulator
A sight glass is installed in the liquid line to
indicate the condition of the refrigerant charge and condition of the moisture in the
11 594 B may also indicate the __________. expansion valve system
To accurately cut the proper size gasket for
installation in a pipeline, you should use
11 595 C __________. tin snips a jack knife
Which of the figures shown in the illustrations
11 596 A depicts an orthographic projection? A B
increase the
In certain circumstances, weldments are reduce internal temperature gradient
11 600 A preheated before each pass to __________. stresses in the weld area
The sectional lines drawn within the flange
sections, shown in the illustration, indicate the direction of machine
11 601 D __________. cutting fitup of flange parts
Which of the filter/strainer units listed permits you
to clean the element while leaving the system on
11 603 B the line? Simplex Duplex
A liquid sight flow indicator in a refrigeration
system is examined and gas bubbles are noted in
motion with the fluid flow. This means the system is fully there is air leaking in
11 604 D __________. charged from the condenser
A manual process used to remove small
irregularities by grinding the contact surfaces
11 605 C together of a valve, is called __________. spotting-in honing
The thickest deposit of scale in a flash evaporator
is most likely to occur in the tubes of the
11 606 C __________. distillate cooler first stage condenser
For cutting thin tubing or sheet metal, the proper the teeth pointing the blade and teeth
11 611 D hacksaw blade should have __________. towards the handle of 'all-hard' quality
The reading on the vernier caliper scale shown in
11 612 B figure "G" in the illustration is __________. 2.308 inches 2.368 inches
The action necessary to use the steering gear align the trick wheel
room trick wheel when transferring the steering to the rudder angle set the six-way
control from the wheelhouse to local control, is to position before control valve in the
11 613 A __________. engaging trick wheel position
In an operating refrigeration system low on
refrigerant, a liquid line sight glass will
11 614 D __________. be clear be blue
doubler plating
plating forming the installed over the flat
11 619 A The inner bottom of a ship is the __________. engine room tank top keel plate
When listed by pitch, which of the hacksaw blades
listed would be the most suitable for cutting thin
11 621 D tubing? 14 teeth per inch 18 teeth per inch
Vessel propellers are classified as being right
hand or left hand. A right hand propeller turns
11 622 B clockwise when viewed from __________. the bow the stern
Which of the listed reasons could cause frost to Shortage of
form on the suction line of a refrigeration refrigerant in the Expansion valve is
11 624 B compressor? system. stuck open.
To properly remove packing from a valve stuffing sharpened rod of
11 625 B box, you should use a __________. silver solder packing puller
The primary reason low pressure evaporators
produce distillate more efficiently, and with less evaporation is due to the higher
scale formation, than high pressure evaporators is accomplished in a temperature of the
11 626 A __________. vacuum incoming feed
The outer strake of the inner bottom on each side
11 629 C of the ship is called the __________. rider plate outer plate
The rubber bladder or separator bag installed in a
hydraulic accumulator should only be filled with
11 631 C __________. pure water pure oxygen
provide a path for the
When drilling holes larger than 1/2 inch, a smaller ensure the maximum dead center of the
11 632 B pilot hole should be drilled first to __________. cut by the large drill drill
Which of the following actions will occur with the Only hose "J" will be
steering system shown in the illustration when The rudder stock "G" placed under
responding to a left rudder command from turns pressure during this
11 633 C amidships? counterclockwise. maneuver.
If the suction line between the evaporator and thermal bulb coming
compressor is frosting up, the cause may be due loose from the needle valve is stuck
11 644 A to the thermal expansion valve __________. suction line closed
Most solenoid valves are actuated by
11 646 B __________. a spring an electromagnet
Before boring a blind tapered hole, a good shop drill to the large
11 660 C practice to follow is to __________. use a tapered reamer diameter of the taper
When coming to the end of a cut using a hand stop applying the reduce cutting speed
11 662 B hacksaw, you should __________. cutting fluid and pressure
Rotation of the steering wheel on the navigation regulating the oil flow
bridge initiates oil pressure being applied to the with the six-way moving the automatic
11 663 D steering gear rams by __________. valve differential valve
Frosting or sweating of the suction line of a
reciprocating refrigeration compressor indicates a
condition which could result in severe damage minor amounts of oil
11 664 B due to __________. in the refrigerant liquid slugging
a defective or broken
A knocking sound from one cylinder of an high pressure
11 665 B operating air compressor indicates __________. unloader a loose valve plate
In order to take suction on the lube oil drain tank
cofferdam with the bilge pump shown in the
illustration, how many suction side valves must be
11 666 B open? One Two
The purpose of an accumulator in a hydraulic collect any dirt in the collect fluid from any
11 671 D system is to __________. system small leak
A swing check valve is used in a pipeline to maintain a preset closely regulate the
11 672 D __________. pressure on the line amount of flow
When the desired rudder angle is attained by a ram relief valves six-way valve shifts
typical double ram electro-hydraulic steering gear, bypass oil to stop to the neutral flow
11 673 D the __________. rudder movement position
A refrigeration system compressor crankcase is a shortage of
sweating or unusually cold. This is an indication refrigerant in the
11 674 C of __________. system air in the system
apply maximum coat the saw blade
A hacksaw blade will start a cut more easily if you pressure at the start with soap before
11 675 D __________. of the cut starting the cut
decreased decreased slippage
Operating a rotary pump at speeds in excess of clearances between to the suction side of
11 676 D design requirements could cause __________. rotating parts the pump
One of the functions of the component labeled act solely as a heat act as a lube oil
11 677 B "E", shown in the illustration, is to __________. exchanger sump
11 682 B The illustrated valve is known as a __________. lift gate valve swing check valve
The letters 'NC' in '1/4-20 NC' indicates the bolt is made of nickel made of
11 705 D __________. cadmium metal noncorrosive metal
Which of the following descriptions identifies the Single inlet and dual Single inlet and one
11 716 B centrifugal pump shown in the illustration? direction of rotation direction of rotation
empty space
between tank tops cement baffle in a
11 719 D A cofferdam is a/an __________. and bilges fresh water tank
If the drill point lips are ground at different angles, overheat rapidly from
11 720 B the drill will __________. rubbing cut an oversized hole
Proper hacksaw cutting is accomplished when
11 721 B pressure is applied only on the __________. backward stroke forward stroke
where possible, be
The annual reinspection of a tank vessel, holding made between the
a two year Certificate of Inspection endorsed, tenth and fourteenth be preceded by
'Inspected and Approved for the Carriage of month of the period written application by
Flammable or Combustible Liquids of Grade A', for which the the master, owner, or
11 729 A must __________. certificate is valid agent of the vessel
11 736 D The designation '1/4-20' describes __________. cutting torch tips size pipe thread die size
Which of the following statements represents the Intercooler, L.P.
path of air flow passing through a typical two cylinder, H.P. L.P. cylinder, air
stage, low pressure, reciprocating, air cylinder, and air cleaner, intercooler,
11 737 D compressor? cleaner and H.P. cylinder
A lightening hole, shown in the illustration, is
11 739 C identified by the letter '____.' A H
Before doing any work on a hydraulic system drain the bleed off all stored
equipped with accumulators, you should accumulators and energy from the
11 743 B __________. purge with oxygen accumulators
Overcharging the
Which of the problems listed could cause erosion system with Faulty compressor
11 744 D of the expansion valve disks and seats? refrigerant suction valve
straightened by
A pump shaft that is bent or distorted should repaired by a suitable applying heat and
11 745 D normally be __________. welding process torsion
prevent scale
The quantity and density of brine discharged from accumulation in the maintain a constant
the last effect of a flash type evaporator should be first effect heat distillate outlet
11 746 C kept at a constant value so as to __________. exchanger surfaces temperature
If an air compressor is used to supply compressed
air to outlets throughout the engine room and on
deck of a vessel, the system is known as the combustion control
11 747 C __________. air system supply air system
number of threads
angle formed by divided by the length
adjacent flanks of aof the threaded
11 751 C The 'pitch' of a screw is the __________. thread portion of the screw
The use of a needle valve in a piping system is close regulation of
11 752 B recommended when requiring __________. high pressure drops flow
will contract in
The hydraulic tubing installation shown as figure diameter and expand and its fittings cannot
"D" is INCORRECT and will probably leak when in in length under be properly installed
11 753 B operation because the tubing __________. pressure and tightened
expansion and
Hydraulic system tubing should be anchored excessive pump contraction of the
11 763 C every three or four feet to prevent __________. cavitation tubing
What basic dimensions are used in describing Diameter and length Diameter and cross
11 775 C machine bolts? only section only
Air blowing from the intake air filter of an operating broken discharge
11 791 A air compressor indicates __________. broken inlet valves valves
Which of the listed valve types is typically used for
suction and discharge valves on modern low
11 792 C pressure air compressors? Poppet Rotary
When any low pressure distilling plant is operated
with less than the designed vacuum, the
11 793 A __________. heat level rises heat level drops
A vacuum is initially created in a flash type the flashing of the the condensation of
11 805 C distilling plant by __________. feed water the saltwater feed
Most pump manufacturers recommend that the
discharge piping for centrifugal pumps be one size reduce the frictional
larger than the pump discharge nozzle to reduce the pump losses due to fluid
11 806 B __________. discharge pressure flow
absorb the brake
The principal purpose of an anchor windlass chain tie off the warping thrust of the anchor
11 810 C stopper is to __________. head lines windlass
Which of the following problems can result in
below normal pressure in the intercooler of an Defective pressure Defective receiver
11 812 D operating low pressure air compressor? pilot valve relief valve
If the supplied steam pressure to the first effect of
a submerged tube distilling plant is allowed to solenoid dump valve air ejector will
11 813 A fluctuate, the distiller __________. will trip operate erratically
purge the condenser check for proper
If a refrigeration compressor is short cycling on if the waterside is water flow through
11 814 B high head pressure, you should __________. dirty the condenser
Which of the listed tools should be used to A steel drift pin and
11 815 A remove a tapered roller bearing from a shaft? An arbor press hammer
Most pump manufacturers recommended that the one size larger than the same size as the
discharge piping for centrifugal pumps be the pump discharge pump discharge
11 816 A __________. nozzle nozzle
bilge-well connected
to that valve, plus the bilge system will lose
second bilge-well vacuum, preventing
If one of the bilge manifold valves is prevented being pumped will be other bilges from
11 838 B from seating, the __________. completely emptied being pumped out
The location of a vessel's frame stations may be
11 839 A obtained from which of the listed drawings? Profile Base line
relieving the
An air compressor can be unloaded at start-up by holding the discharge intercooler pressure
11 847 B __________. valve open to the atmosphere
Flexible hose under pressure in a hydraulic tend to twist about its expand in length and
11 853 C system will __________. long axis in diameter
The compressor in the ship service refrigeration
system is short cycling on the high pressure
cutout switch. The probable reason for this is the discharge valves are discharge valves are
11 854 C __________. leaking excessively leaking slightly
Which of the following statements describes the Both are higher than
relationship between flash point and ignition normal burning The flash point is
11 855 C temperature? temperatures. always higher.
provide sensing of
In the illustrated steam pressure reducing valve, downstream equalize pressure
the purpose of the item labeled "C" is to pressure to the above and below the
11 859 D __________. control diaphragm power piston
On tank vessels using an automatic tape wells,
free movement of the tape is normally checked by removing the side operating the hand
11 860 B __________. plate clutch
In order for all of the bilge pump discharge to pass
through the oily water separator, shown in the
illustration, the oily water separator bypass valve
11 861 B must be __________. completely open completely closed
The valve depicted in the illustration shown is a
11 862 D __________. gate valve check valve
Coast Guard Regulations (46 CFR) require
remote controls for stopping fuel oil service located at the control provided with a
11 863 D pumps. These controls shall be __________. platform locked cover
the pressure an excessive lack of
If a refrigeration compressor will not start, the regulating valve is refrigerant in the
11 864 B reason may be __________. not closing system
The lowest temperature required to cause self-
sustained combustion of a substance independent
of any outside source of ignition is called
11 865 C __________. explosive range flash point
are subjected to a
Automatic pressure control valves for steam wide range of
service require periodic maintenance inspections are subjected to high temperatures and
11 871 C because they __________. compressive stress pressures
Double cut files are most effective when used for
11 872 D __________. sharpening tools draw filing
Which of the listed figures represents the
configuration and alignment of the inlet/outlet
11 873 D head, as viewed from the tube side? A B
When a refrigeration compressor motor fails to low differential
start, the FIRST thing that should be checked for loose expansion setting on the H.P.
11 874 C is a __________. valve control bulb cutout
separated from
provided between accommodation
On small passenger vessels, separation of each of these spaces spaces by watertight
machinery and fuel tank spaces shall be by watertight and/or and/or vaportight
11 891 B __________. vaportight bulkheads bulkheads
Which of the listed types of files is the best for
11 892 A producing a fine finish on metal? Mill Float
How often should cargo oil pump relief valves on Prior to each cargo At least once each
11 906 C tank vessels to be tested? discharge operation. voyage.
Round split dies are usually adjustable to allow threading on control the tightness
11 911 B __________. oversized stock of the thread fit
Dirt should not be allowed to contaminate a dirt will cause bearings will leak oil
11 916 C grease lubricant because the __________. corrosion of bearing excessively
double the liquid
velocity through the
pump when
The function of a centrifugal pump double volute reduce radial thrust compared to a single
11 917 A casing is to __________. on the impeller volute
At the designed
operating The liquid refrigerant
temperature, the tends to collect at the
Which of the listed statements is a characteristic liquid refrigerant bellows or diaphragm
of the liquid charged power element used with charge has changed and reduces the
11 922 D thermostatic expansion valves? to a vapor. valve sensitivity.
Rapid fluctuations in the shell pressure in a decreased priming
submerged tube distilling unit will cause increased heat levels and high salinity
11 923 D __________. in the entire unit distillate
It is the temperature
at which a substance
Which of the following statements is correct It is lower than the will spontaneously
11 945 A concerning the 'flash point' of a liquid? ignition temperature. ignite.
The primary function of a centrifugal pump volute develop a high convert velocity to
11 947 B is to __________. velocity liquid pressure
If your vessel burns 8 tons of fuel per hour at 15
knots, how many tons per hour will it burn at 18
11 949 A knots? 13.82 tons 15.61 tons
Maximum speed
when rotated in the
'hauling in' direction
Control over speed, would be obtained
direction, and with the tilting box
stopping would be just prior to neutral
Which of the following statements describes the better than having stroke, while 'pay out'
actions of an axial piston motor with a full the pump equipped would be the
11 958 D deflection variable position tilting box? with the tilting box. opposite.
A ship travels 234.02 nautical miles in 24 hours at
an average propeller speed of 60 RPM. If the
propeller pitch is 20.07 feet, what is the propeller
11 959 A slip during this passage? 17.95% 20.46%
A comparable pump
tilting box if used in a
The designers of the hydraulic motor,
With regards to axial piston hydraulic pump/motor equipment have would eliminate the
power units, motor speed is a function of fluid flow never considered the hydraulic lock to the
rate generated by the pump. Which of the use of the tilting box system when the
following statements describes why the motor is with a hydraulic motor is placed in
11 968 B NOT manipulated as is the pump? motor. neutral stroke.
imparts energy to a
fluid to move it from
11 1027 B A pump is defined as a device that __________. produces pressure point "A" to point "B"
A vessel departed from point "A" at 1206 with a
counter reading of 616729 and arrived at point "B"
with a counter reading of 731929 at 1148 the
following day. This vessel is equipped with a 20
foot 8 inch diameter propeller, with a pitch of 20
feet. The observed distance of 404.16 miles was
covered at an observed speed of 16.85 knots.
11 1029 C What should be the apparent slip for this trip? 1.04% 1.29%
To safely remove the piston rod packing from the open the throttle
steam end of a reciprocating pump, you should valve and 'blow' the
11 1041 A __________. use a packing hook old packing out
11 1042 B The tang of a file is the part that __________. does the cutting fits into the handle
When a lathe is used for thread cutting, the
number of threads per inch produced is
determined by the speed relationship between the drive motor and
11 1043 C __________. spindle spindle and feed rod
Subcooling is a method of reducing the
temperature of the liquid refrigerant below its
11 1044 C __________. freezing point floc point
The valve which is most suited for regulating the
11 1045 B flow through a pipeline is a __________. gate valve globe valve
The reading on the micrometer scale shown in
11 1046 D figure "D" in the illustration is __________. 0.4710 inch 0.4715 inch
suction head is high,
A centrifugal pump must have a stuffing box liquid and is handling a is handling a liquid
sealing line and seal cages installed if the pump cool, debris free with a temperature of
11 1047 C __________. liquid less than 150°F
The illustrated hydraulic pump graphic symbol is
11 1048 D used to depict a __________. parallel, pump unit two-stage, pump unit
A follower rest should be used with a lathe to large diameter stock threads on long
11 1053 B machine __________. between centers slender shafts
In the illustrated refrigeration system, component
11 1054 B "G" is the __________. expansion valve compressor
A set of numbered
Which of the drill sets listed would commonly be size drills from 1 to A set of lettered size
11 1055 C referred to as a 'Jobbers Set'? 60. drills from A to Z.
The correct torque value for a micrometer torque the scale is read on the dial is read on the
11 1062 C wrench is reached when __________. the handle handle
To commence cutting threads with a metal lathe,
11 1063 B you should engage the __________. feed-change lever split or half-nut
density of a
substance in water
with the density of differences in volume
A hydrometer measures specific gravity by the same subject in between water and
11 1080 D comparing the __________. air the liquid measured
11 1082 A A micrometer screw has a pitch of __________. 40 threads per inch 50 threads per inch
setting over the using the compound
11 1083 D A taper may be turned on a lathe by __________. tailstock rest
Refrigerant enters the condenser as a
11 1084 C __________. high pressure liquid low pressure vapor
between the
passenger and cargo
11 1109 D The collision bulkhead is located __________. on the bridge deck areas
According to Title 46 CFR, of the equipment listed
below, which equipment must be tested NOT
more than 12 hours prior to getting underway from
a U.S. port when the voyage is to be of 48 hours
11 1110 A or greater duration? Steering gear Shaft generator
maintain the
feedwater
temperature above
When a flash evaporator is being operated in prevent cold the required
extremely cold water, you may need to throttle the shocking the minimum input
11 1122 B seawater supply to __________. evaporator temperature
The dead center of a lathe can be properly used
only after the end of the work piece has been
11 1123 C __________. counter bored tapered
pressure at
Flash gas formed in the liquid line of a expansion valve inlet expansion valve pins
11 1124 B refrigeration system may cause __________. to increase and seats to erode
Which of the drill sizes listed represents the
11 1125 C largest size drill? A X
Which of the illustrations depicts the correct
11 1126 B procedure for applying pipe dope? A B
The device shown in the illustration is commonly
11 1128 D known as a/an __________. quad seal soft-packing seal
Overheating of the hydraulic fluid in an electro-
hydraulic anchor windlass can result from a/an overload on the low fluid level in the
11 1129 B __________. pump motor reservoir
On hydraulic type
steering gears, a
suitable arrangement
of check valves in the
According to Coast Guard Regulations (46 CFR), main piping system
which of the following statements is correct Hydraulic structural may be considered
regarding the steering apparatus requirements for rudder stops are as a means of
11 1130 C a vessel over 250 feet in length? mandatory. steadying the rudder.
A dirty intercooler on the ship service air decreased higher than normal
11 1131 B compressor will result in __________. compression ratio power consumption
Which of the listed conditions will cause the feed
water, that has not flashed to vapor in the first-
stage of a flash evaporator, to flow into the Higher vacuum in the
11 1132 B second-stage? Gravity siphon effect second-stage
In a refrigeration system, the heat normally the hot gas bypass the portion of liquid
producing the flash gas at the thermostatic connection at the refrigerant which
11 1134 B expansion valve, is obtained from __________. threeway valve does not flash
to prevent seawater
from passing out the
stuffing box when a
Sealing lines provide sealing liquid flow to the high suction head is
11 1135 B stuffing box of a centrifugal pump __________. present to cool the shaft
A twist drill gage can be used to measure the
11 1136 B drill's __________. length diameter
Under normal operating conditions, the highest
temperature and pressure conditions existing for
flash-type evaporators will occur in the
11 1137 D __________. first stage second stage
Coast Guard Regulations (46 CFR) require that served by two provided with a motor
electric and electro-hydraulic steering gear motors electric power feeder running overcurrent
11 1150 A shall be __________. circuits protection device
increasing the
Excessive lube oil consumption by a reciprocating operating pressure using oil having an
11 1151 D air compressor can be caused by __________. differential excessive viscosity
increasing or
decreasing the
number of packing
The total length of stroke in a reciprocating steam rings around the variations in the
11 1152 D pump can be adjusted by __________. piston rod throttle adjustment
In the device illustrated, if part "D" rotates counterclockwise and clockwise and act
11 1158 C clockwise then part "E" will rotate __________. act upon part "H" upon part "H"
Sounding tubes and access openings for fuel oil
tanks on cargo vessels are permitted by Coast
Guard Regulations (46 CFR) to be located in
11 1159 D which of the listed spaces? Washrooms Laundries
An electric driven steering gear power unit is
required by Coast Guard Regulations (46 CFR) to
be capable of putting the rudder over from 15° on
one side to 15° on the other side in not more than
60 seconds under emergency power with the
vessel running ahead. For a 20 knot vessel, this
11 1160 B test must be carried out at __________. 7 knots 10 knots
stuffing boxes
eliminate the leakage helical gear pumps
problems usually are essentially self-
Positive displacement, helical gear pumps are well associated with other priming and produce
11 1186 B suited for pumping oil because __________. gear pumps high suction lift
Scale formation in a flash-type evaporator is tubes of the salt
11 1187 B usually found in the __________. flash chamber walls water feed heater
will move to the left,
If the device shown in the illustration is being used will move to the right, and "C" will move to
to control the output of an axial piston pump, and "C" will move to the right, but will lag
when part "A" is moved to the right, then part "B" the left, but lagging behind the
11 1188 B __________. behind "B" movement of "A"
Coast Guard Regulations (46 CFR) require a positive
hydraulic steering gear systems to be equipped a suitable arrangement for
with a means of steadying the rudder in an arrangement of stop stopping the rudder
emergency. This may be accomplished with valves in the main before the rudder
11 1190 A __________. piping stops are reached
After disassembly, the safest way to remove
carbon deposits from air compressor inlet and
11 1191 B discharge valves is to use __________. ammonia diesel oil
In a water cooled stern tube, a slight leakage of flush all dirt and grit
water across the packing gland is provided to flush all dirt and grit from the bearing
11 1192 C __________. from the gland staves
If the distances "A" and/or "B" as shown in the
illustration are excessively increased, the tool will
11 1193 A __________. chatter take a shallow cut
The component of a refrigerating system in which
the refrigerant vaporizes and absorbs heat is
11 1194 D known as the __________. condenser vapor generator
In which of the areas listed would you expect to
find the highest salt concentration in a flash Distiller air ejector Saltwater heater
11 1195 D evaporator? cooling medium discharge
prevent excessively
saline distillate from
The purpose of a three-way, solenoid, dump valve entering the drain the evaporator
11 1225 A on an evaporator is to __________. freshwater system first-effect only
Reduced capacity, accompanied by vibration and
noise at the suction of a centrifugal pump is a
11 1226 A result of __________. cavitation water hammer
the absolute
The size of the loop seal orifice for a flash-type the vacuum pressure differential
evaporator is important for maintaining the control differential developed developed between
11 1227 D of __________. between both stages both stages
A measurement of .625 inches is equal to
11 1229 C __________. 15/32 inches 9/16 inches
In order to accurately measure very low positive
pressures, which of the instruments listed should
11 1230 C be used? Compound gage Bourdon tube
Which of the following components listed is shown Variable
11 1231 C in the illustration? Heat exchanger displacement pump
excessive strain on
Joints in pipelines must be properly aligned before the joints will result if misalignment permits
11 1251 A they are connected because __________. they are misaligned excessive expansion
short heavy casting long workpiece for
The lathe steady rest is normally used for held in a three jaw facing, drilling, and
11 1253 B supporting one end of a __________. chuck boring
Fluctuations in the pressure and temperature of increased heat levels decreased priming
the steam supplied to the first-effect of a low throughout the entire and lower distillate
11 1265 D pressure distilling plant will cause __________. unit salinity
If a centrifugal pump operating with a positive
suction head becomes air bound, your FIRST
11 1266 A response should be to __________. vent the casing close the discharge
cause the potential
level of kinetic
If 'wet' steam is supplied to the air ejectors of a energy to be partially
low pressure evaporator, the passage of the improve overall converted to thermal
11 1267 B mixture through the nozzles will __________. vacuum energy
When assembling a run of liquid service piping, How the type of What type of gasket
which of the following factors should be fittings used will material should be
11 1271 D considered? affect the flow. used.
From where does the air ejector take its suction First Effect vapor Second Effect
11 1291 B on a Soloshell double effect distilling unit? feed heater distilling condenser
Work that cannot readily be mounted between
11 1293 B lathe centers is usually held in a __________. crotch center chuck
The refrigeration system shown in the illustration
uses which of the components listed to separate
11 1294 A the 'high' side from the 'low' side? G and K G and H
In a double-effect distilling unit, the brine in the
second-effect is additionally heated by
11 1295 C __________. auxiliary steam air ejector steam
When securing a distillate pump on a low
pressure fresh water evaporator, which of the Close the pressure
11 1296 C listed steps should be carried out FIRST? Stop the pump. gage valves.
A vacuum is initially established in the first and vacuum drag from
second stages of a low pressure evaporator by the auxiliary individual vacuum
11 1297 D the use of __________. condensate system pumps
For efficient and proper operation, the brine 3.5 pounds of salt 1.5 pounds of salt
density in a submerged tube evaporator should per 32 pounds of per 32 pounds of
11 1325 B be maintained at __________. water water
Regarding the low pressure evaporator steam
control orifice in the live steam supply line, the
steam at the outlet of the orifice if not properly desuperheated
11 1327 B conditioned will be developed as __________. steam superheated steam
A tailstock 'dead center' has been given that name is dead centered on
11 1333 B because it __________. the tailstock spindle does not revolve
The temperature of the refrigerant in the cooling water
evaporator coil depends mostly upon the refrigerant pressure temperature to the
11 1334 A __________. in the evaporator condenser
Which of the following types of hydraulic pumps
11 1335 C would be used in a steering system? Lobe Screw
The amount of the cushioning effect developed position of the adjustment of the
within a hydraulic cylinder is determined by the directional port in the cushion cavity check
11 1336 D __________. cushion cavity valve
Two position
Which of the listed modes of controls will identify Proportional-plus- differential gap
11 1337 A the device shown in the illustration? reset control control
three-position
The device shown in the illustration is known as offset directional pressure reducing
11 1338 C a/an __________. control valve valve
According to U.S. Coast Guard Regulations (46
CFR Part 32), when reach rods to tank valves
pass through the deck, the stuffing box at this joint grounded with
11 1339 C must be __________. bonding straps water tight
A 12" X 8" X 8" simplex double-acting pump
makes 100 strokes per minute. If the slip is 6%,
11 1341 C the discharge rate is __________. 62.54 gpm 81.81 gpm
An unsteady vacuum in a submerged tube air leaks in the tube improper venting of
11 1342 C evaporator may be caused by __________. nests the tube nests
the compressor the compressor
An increase in the heat load to a refrigeration suction pressure to suction temperature
11 1344 B system will cause __________. decrease to increase
The inability to maintain proper vacuum in a fluctuating steam improper venting of
submerged tube evaporator can be caused by pressure to the air the evaporator tube
11 1345 A __________. ejector nozzle nests
Generally, centrifugal pumps operating without a
positive suction head must be primed before they
will move liquid on their own. The priming is rotating liquid piston
11 1346 B usually accomplished with a __________. regenerative pump pump
The process control mode shown in the illustration
is an example of which of the listed modes of
11 1347 B control? Proportional control Integral control
According to Coast Guard Regulations, flexible the working pressure the working pressure
hoses used as supply and return lines to of the system of the system
hydraulic system components, must have stamped on one of stamped on both of
11 1350 D __________. the end fittings the end fittings
Which of the listed values represents the
temperature of saturated vapor for water at a
11 1351 B pressure of 14.7 psia. 198°F (92°C) 212°F (100°C)
The discharge head of a centrifugal pump will vary change in impeller square of the
11 1353 B directly with the __________. diameter impeller diameter
The boiling point of water in an open container at
sea level is 212°F. If the pressure on the open
container is decreased, the boiling point will
11 1354 B __________. increase decrease
The Certificate of Inspection for your vessel was Inform the nearest Defer informing the
issued in January. In March of the same year you Officer in Charge, Coast Guard of the
need to replace a cooling water pump for the Marine Inspection of pump's replacement
refrigeration system. What action would be the pump until the mid-period
11 1389 D appropriate? replacement. inspection.
Hydraulic force is
applied The single-acting
simultaneously in two ram is both extended
Which of the following statements concerning the directions against the and retracted by
operation of a single-acting hydraulic ram is ram by directional means of hydraulic
11 1392 C correct? ports. force.
Oil is discharged
Which of the following statements is correct with from the center of the Gravity causes the oil
regards to the operation of a centrifugal cargo impeller through the to flow toward the
11 1396 D pump? outlet. discharge.
diverting the flow automatically
Some fluid filters used in hydraulic systems are automatically to the bypassing the fluid
designed to cope with increasing pressure standby filter of the via an internal valve
11 1398 B differentials by __________. duplex unit arrangement
The renewal of a
superheater safety
valve with one of the A vessel being
same kind that was placed in drydock for
certified by a Coast the purpose of
Guard inspector at repainting the
Which of the following would require the Officer in the place of underwater portion of
11 1409 D Charge, Marine Inspection be notified? manufacture. the hull.
A pneumercator is used to indicate fuel oil
11 1410 B __________. pressure level
Which of the following statements concerning Energy can be Energy may not be
11 1411 C energy is correct? created or destroyed. transformed.
By which of the following means is force efficiently
provided to vary the pitch of the blades on a
11 1412 A modern controllable pitch propeller? Hydraulic Mechanical
A 25 ton refrigeration
Dehydrators must be system has the same
used continuously in cooling effect as
Which of the listed statements is correct a refrigeration melting 25 tons of ice
11 1414 B concerning refrigeration systems? system. in 24 hours.
When the vessel's steering wheel on the
navigation bridge is turned, the difference existing
between the position of the wheel and that of the
11 1417 B rudder is known as __________. proportional band the error signal
A ballast pump with a capacity of 200 gpm (757
lpm) is used to fill a ballast tank with seawater. If
the pump discharges seawater into the tank for
one hour, how many tons of saltwater ballast have
11 1419 A been taken onboard? 45.85 (46.5 t metric) 48.53 (49.32 t metric)
Frost appearing on one set of evaporator coils of increase the value of will assist in
a multi-box, direct expansion type refrigeration superheat to the fluid increasing the
11 1434 C system __________. leaving the coils refrigeration effect
To set the dividers to the proper radius, you
11 1435 C should use a __________. micrometer scribing circle
an unbalanced force
exerted from the unequal or
Theoretically, a double suction impeller is in direction of the nonuniform flow to
hydraulic axial balance. In actuality this balance impeller nearest the the suction eyes of
11 1436 B is rarely achieved due to __________. driving motor the impeller housing
When using the circular magnetic particle method current is flowing at magnetic field is
to nondestructively test a weldment, the best right angles to the parallel to the
11 1463 C results are obtained when the __________. discontinuity discontinuity
If a refrigeration compressor is running
continuously without lowering the temperature in
the refrigerated space, the trouble may be a shortage of warm food in the
11 1464 D __________. compressor oil refrigerator
The temper is likely to be drawn out from a chisel hold it next to a wet soak it in hot oil for
11 1465 D edge when you __________. grinding wheel lengthy periods
When a controller is provided with reset rate desired value of the floating rate of the
adjustment, a change in this adjustment results in proportionally proportional-speed
11 1477 B a change of the __________. controlled variable floating component
When a non-butterfly valve is closed, the motor of
the device illustrated will be secured by a
11 1478 A __________. torque switch limit switch
What precautions should be followed when using Remove the ragged Do not strike the
11 1485 A a chisel having a mushroomed head? edges by grinding. mushroomed portion.
in either fully closed
A gate valve installed in a piping system should or fully opened only with the stem
11 1486 A be used __________. positions facing down
The device shown in the illustration is used to
open and close a butterfly valve. The motor will
be typically secured during the closing phase by
11 1488 B the use of the __________. torque switch limit switch
When pressure is applied to a Bourdon tube-type pressure is the pressure is the
pressure gage, it will begin to unbend. The greatest on the arc greatest on the arc
11 1489 C reason for this action is that the __________. AB DC
Which of the listed methods of heat transfer takes
place when two substances of different
temperatures are in physical contact with each
11 1491 B other? Radiation Conduction
The device depicted in the illustration is used to jack over the main power an elevator
11 1498 D __________. engine car
Which problems can occur if the brake band lining The driving engine The anchor will
11 1499 D of a wildcat brake becomes excessively worn? will overspeed. immediately drop.
provide convenient
grouping of all piping
leading fore and aft
insulate piping from from the machinery
The purpose in constructing a pipe tunnel aboard ambient space for easy
11 1519 D a vessel is to __________. temperatures access and control
When air becomes trapped in the hydraulic fluid of rudder will respond hydraulic rams will
11 1520 A a steering system, the __________. sluggishly overspeed
Before starting a reciprocating, steam-driven
pump that has been idle for a period of time, you open the steam line drain the steam
11 1521 B should __________. root valve cylinder
The air charge leaving an intercooler, or
aftercooler of an air compressor can be expected
11 1523 C to be __________. superheated supercooled
Noise in a refrigeration compressor can be worn bearings and slugging due to
11 1524 D caused by __________. piston pins flooding back
Thermal energy is commonly referred to as
11 1525 A __________. heat power
Soldering flux aids the soldering process by
11 1526 C __________. softening the metals fusing the metals
The cylinder unloading mechanism used on low
pressure air compressors is an example of which
11 1527 A mode of control? Two position Derivative
Valves used in the machinery space piping
systems, and constructed with threaded valve right-hand opening left-hand closing
11 1528 C stems, must be __________. (clockwise) (counterclockwise)
A compressor used in a multi-box refrigeration
system, has six of its eight cylinders controlled for
variable loads. If only one of five reefer boxes is
active what percentage of the controlled cylinders
11 1529 A will be unloaded? 100% 66%
hammering noises in
Air trapped in the hydraulic fluid of a steering an improper rudder the equipment or
11 1530 D system would be indicated by __________. response transmission lines
Which of the chisels listed should be used for
11 1531 C cutting oil grooves? Diamond point Flat cold
To determine the diameter of a small hole, which
of the listed tools must be used with inside
11 1532 C calipers to get an accurate reading? A Center gage Wire gage
reaches the
'Flooding back' is a condition where the liquid vaporizes in the compressor through
11 1534 B refrigerant __________. condenser the suction line
The energy associated with molecules is known
11 1535 D as __________. kinetic energy potential energy
Flux is used when soldering, in order to decrease the melting
11 1536 D __________. point of the solder make the solder 'flow'
Which of the following proportional band values
11 1537 B most closely approaches 'ON-OFF' control? -10% 2%
In most pumps and pump motors, overpacking the moisture insufficient circulation
ball bearings full of grease will result in emulsification of the and overheating of
11 1569 B __________. bearing grease the bearing
prevent pressure
from developing
provide pressure within the bellows
sensing from the that would adversely
compressor affect the operation
The function of port "D" shown in the illustration is crankcase/ suction of the unloader
11 1570 B to __________. line control
examine the
When a vessel is in dry-dock, the vessel's condition of the chip and paint all hull
11 1571 A engineers should __________. propeller protection zincs
If you change from a low pour point lubricant to a compressor
high pour point lubricant in a refrigeration system, lubrication will be oil will not leave the
11 1572 D __________. improved crankcase
The demisters installed in a flash-type evaporator deaerate the first filter the condensed
11 1575 D serve to __________. effect distillate flash vapors
Mechanical energy in transition is referred to as
11 1576 B __________. horsepower work
In a two-stage flash-type distilling plant, the mesh- improve distillate vent noncondensable
11 1585 A type vapor separators function to __________. purity gases
What is the gain in potential energy of an object
weighing 10 pounds when it is raised to a height
11 1586 C of 10 feet? 10 ft-lb 20 ft-lb
11 1607 B Reset control is also referred to as __________. derivative control integral control
The device shown in the illustration is typically
designed to operate in conjunction with a
pneumatically controlled valve in order to relatively constant
11 1608 A maintain __________. liquid tank levels steam flow rates
Referring to Coast Guard Regulations (46 CFR), has no independent is independent of the
11 1615 B the emergency bilge system __________. primary pump main bilge system
Increasing the speed of a centrifugal pump will diameter of the diameter of the
result in an increase in its capacity. Another discharge piping, suction piping, with
means of increasing the capacity of a centrifugal with all other factors all other factors
11 1619 D pump is to increase the __________. remaining the same remaining the same
While inspecting the steering system at sea, you air bubbles in the any leaks in the
11 1630 B should check for __________. sight glass system
The viscosity of the
fluid is relatively The pump can only
How does the viscosity of a fluid being pumped unimportant in the be used for fluids of
11 1632 A affect the operation of a spur gear pump? pump operation. high viscosity.
If one box in a multiple box, direct expansion type
refrigeration system was experiencing an liquid refrigerant
excessively low temperature, this could be a result returning to the excessive frost on
11 1634 C of __________. compressor the cooling coils
Leaking suction valves in a refrigeration higher than normal lower than normal
11 1644 A compressor are indicated by __________. suction pressure suction pressure
determines the
amount of acetylene
In an oxygen acetylene welding outfit, the torch tip depends on the hose and oxygen fed to
11 1645 B orifice size __________. length the flames
Both pumps
operating at the Each pump operating
Which of the following conditions would be same speed and at a different speed
hazardous if you were using two centrifugal discharging into a and discharging into
11 1646 B pumps to discharge a flammable liquid? common line. a common line.
saponifying a metal
reducing the base, to which oil is
temperature of an oil then added and
below its cloud point mixed under
to create the controlled
11 1647 B Greases are generally produced by __________. gelatinous texture temperature
change the
In order to change the set point of the system compression of the
using the illustrated device, you must rotate part "I" spring located below
11 1648 D __________. counterclockwise part "H"
prevent the oil from
The oil in a cargo winch gear box should be prevent the gear box becoming
11 1649 C sampled periodically to __________. from leaking inflammable
When the steering gear is in operation, you should check hydraulic oil check the rams for
11 1650 C __________. levels every hour overheating
What class of screw thread is indicated with a
11 1651 D machine screw described as 1/2-13 NC-2? 2-Jan 13
The capacity of a rotary pump, delivering a
constant viscosity fluid, will decrease when the
discharge pressure is increased, due to decreased suction increased suction
11 1652 D __________. pressure pressure
Which of the following forms of energy is usually
associated with the motion of large bodies or
11 1653 B objects? Chemical energy Kinetic energy
A refrigeration system is equipped with a
reciprocating compressor and a water cooled
condensing unit. If the system is overcharged, the the expansion valve
resulting high head pressure will be caused by overfeeding the a leaking compressor
11 1654 D __________. evaporator suction valve
If you are given the job of adding hydraulic fluid to add fluid that is the add turbine oil
a mooring winch, and are not certain as to the same color as the because it is always
11 1679 D type of fluid to use, you should __________. fluid in the reservoir a good substitute
A gradual decrease in the discharge pressure of the bleeder valve
an operating hydraulic pump can be caused by the four-way control sticking in the open
11 1680 D __________. valve failing to shift position
applied pressure applied pressure
The Bourdon tube-type pressure gage will begin being the greatest on being the greatest on
to straighten out when pressure is applied due to the outer the inner
11 1682 D the __________. circumference circumference
temperature
The rate of heat transfer from a hot region to a difference between
11 1683 B cold region is affected most by the __________. size of the heat sink the regions
Maximum and
When replacing a steam pressure reducing valve, minimum inlet Reduced pressure or
11 1685 D what information is required for the selection? pressures pressure range
In a flash-type evaporator, an electrical salinity distillate outlet from distillate inlet to the
11 1701 D cell would be installed in the __________. the distillate cooler distillate cooler
If the viscosity of the liquid being transferred
remains constant as the discharge pressure capacity will
11 1702 B increases, the rotary pump __________. capacity will increase decrease
When metal is tempered, it becomes
11 1703 C __________. harder corrosion resistant
If the suction pressure at the refrigeration
compressor is below normal, the cause can be refrigerant overfeeding by the
11 1704 C __________. overcharge expansion valve
a space within three
Coast Guard Regulations (46 CFR) prohibit air meters of a cargo a space in which
11 1706 D compressors from being located in __________. valve cargo hose is stowed
'Offset' is an inherent characteristic of which of the
11 1707 B following types of control modes? Two position Proportional
In order to increase the set point of the control
valve as illustrated, used to regulate the output
temperature of a hot water heater, the part labeled "K" must be rotated "A" must be rotated
11 1708 B __________. clockwise counterclockwise
All the seals in the The lifting capacity of
If dirt is allowed to contaminate the sump of a hydraulic lines will the crane will be
hydraulic deck crane, which of the following immediately blow immediately reduced
11 1710 D problems will occur? out. by 70%.
Where would a salinity cell be installed in a Distillate pump Tube nest drain
11 1711 D double-effect distilling plant? discharge pump discharge
Which of the listed conditions will occur if the
discharge pressure of a rotary pump is increased
from the designed 50 psi to 300 psi, while The pump capacity The pump capacity
11 1712 A maintaining the same RPM? will be decreased. will be increased.
Reheating a hardened component to a
temperature lower than the hardening
temperature and then cooling it is known as low temperature
11 1713 D __________. hardening case hardening
If the suction pressure for an operating
refrigeration compressor is below normal, the an excess of liquid the expansion valve
11 1714 C cause may be __________. refrigerant overfeeding
When a new section of shell plating is being minimize shrinkage ensure that all
installed, the proper weld sequence must be stresses and harmful weldments are
11 1719 A followed to __________. distortion downhand
In the illustration, the welded neck flange is
11 1721 C attached to the pipe by a __________. double fillet weld only plug and slot weld
A salinity indicator is used to determine the cause of salt location of salt water
11 1722 B __________. contamination contamination
Officer in Charge,
Oil sprays on to a hot piece of machinery, catches Marine Inspection at
fire and causes $35,000 damage to your vessel. nearest Coast Guard the first port of
11 1725 B By law this must be reported to the __________. unit arrival
Coast Guard Regulations (46 CFR) require safety
and relief valves for air service to be provided
with a substantial lifting device, capable of lifting 50% of that at which 75% of that at which
the disk from its seat when the pressure in the the valve is set to the valve is set to
11 1726 B vessel is __________. blow blow
Which of the tools listed should be used with the Phillips head
11 1733 D set screw shown as figure "F" in the illustration? screwdriver Spanner wrench
In an operating, water-cooled, multi-box
refrigeration system, both low discharge and high
suction pressures are being simultaneously overcharge of
experienced. The probable cause for this refrigerant in the fouled shell-and-tube
11 1734 D condition is a/an __________. system condenser
Dimension "X" indicated on the architects scale,
shown in the illustration, will be equal to
11 1735 B __________. 5 feet 3/4 inch 5 feet 4 inches
Charring or glazing of the inner circumference of
the packing rings in a centrifugal pump, is caused undertightening the failure to seat the
11 1736 C by __________. packing packing rings
a minor accumulation
If a refrigeration compressor had developed a of air or
high suction pressure, the problem could be a noncondensable
11 1744 D result of __________. gases in the system a leaking king valve
If you have to completely grind a new point on a
high speed drill, which of the following could The 59° angle will be
happen if it is cooled in cold water immediately The edges will be lost due to metal
11 1745 C after grinding? dulled. contraction.
hydrostatically tested
at a pressure equal
According to Coast Guard Regulations, if a hydrostatically tested to 1 1/2 times the
pressure vessel, such as a ships service air tank, at a pressure equal maximum allowable
has defects which may impair its safety, the tank to the design working pressure of
11 1746 B shall be __________. pressure of the tank the tank
11 1747 C A pure transducer utilizes __________. integral action rate action
values for properties specific fuel
of water and steam consumption under
Steam tables can be used to obtain the vapor at various steady steaming
11 1749 A __________. conditions conditions
The rate of heat transfer between the hot and cold remain constant be greatest in a
fluids passing through a shell-and-tube type heat along the tube's single pass counter
11 1750 D exchanger will __________. length flow heat exchanger
Which illustration correctly depicts a double bevel
11 1751 B groove weld? 4A 3B
A tool used for measuring, or laying out angles is
11 1752 B called a __________. trammel protractor
a minor accumulation
If a refrigeration compressor had a higher than of air or
normal suction pressure, the problem could be a noncondensable a constant loss of
11 1754 C result of __________. gases in the system refrigerant
The general purpose of a heat exchanger is to eliminate hot air from maintain steady
11 1770 C __________. the condenser pressure in a system
To ensure a good weld, post heating is required
whenever an arc weld repair is made with a straight with a reverse
11 1771 C __________. polarity rod polarity rod
To get an accurate measurement using a 12 inch
machinist's steel rule, you should measure from the one inch from the zero end on
11 1772 A __________. graduation mark the scale
the bite is taken the wrench jaws are
A pipe, or Stillson wrench functions best when midway up the jaw at the widest open
11 1773 A __________. teeth setting
Which of the following problems could cause the
high pressure cutout switch to shut down the A shortage of liquid Excessive frost on
11 1774 D compressor in a refrigeration system? refrigerant. the evaporator.
adjusting the
effective moment
arm length between adjusting the pointer
A proportional band, or range adjustment of a the bourdon tube and position relative to
bourdon tube pressure gage is accomplished by the quadrant gear the shaft on which it
11 1787 A __________. fulcrum is mounted
control action to be
control action to be accomplished by a
accomplished with a relatively small
In the illustration shown, the operating piston "H" relatively small amount of
in the valve has a larger surface area than the amount of high downstream low
11 1795 A main valve disc to allow __________. pressure steam pressure steam
adjusting the
effective moment
arm length between adjusting the pointer
the bourdon tube and position relative to
The zero set point adjustment of a bourdon tube the quadrant gear the shaft on which it
11 1797 B pressure gage is accomplished by __________. fulcrum is mounted
Which of the conditions listed will cause the Bleeding the gas Reducing the relief
hydraulic pump relief valve to remain open during charge from the valve spring
11 1798 B the operation of the system? accumulator. compression.
The solenoid
During the repair and overhaul of the pump relief The pump discharge controlled, three-
valve, used in a hydraulic system, the set point pressure will remain position, spring
was reduced by 100 psi. Which of the following at the same pressure centered control
statements describes the result of the set point prior to the relief valve response will
11 1808 D being lowered? valve being repaired. be quicker.
dropping a one
ounce grease sample
allowing a from one meter, and
suspended cone to observing the
drop into a sample of resulting spread
grease for five pattern, uniformity of
seconds and thickness, and
A drop test is carried out on a sample of grease determining the consistency of
11 1809 D by __________. depth of penetration texture
Cavitation in a hydraulic pump is indicated by
noisy pump operation and can be caused by a/an high fluid level in the hydraulic fluid low
11 1810 D __________. reservoir floc point
When welding mild steel with a shielded metal-arc
electrode, and getting only shallow penetration, speed up your
11 1811 D you should __________. use a lower current electrode travel
The three basic parts of any eductor are the
nozzle, the suction chamber, and the
11 1812 C __________. injector compressor
The wedge-shaped
oil film's load carrying The load carrying
Which of the following statements is true capacity is capacity is inversely
concerning the hydrodynamic wedge developed determined by its proportional to the
11 1813 A by lubricating oil? length and thickness. velocity of the fluid.
the relief valve
the relief valve should open and
If the head pressure of a reciprocating should open before allow the excess
refrigeration compressor is excessive, the high pressure refrigerant to flow to
11 1814 C __________. cutout the receiver
Air trapped in the hydraulic fluid of a steering the steering pumps a jammed open relief
11 1830 C system may be indicated by __________. overspeeding valve
Setting up a welding job, where the work is the
positive pole and the electrode is the negative straight polarity inert-arc welding
11 1831 A pole for the arc, is known as a/an __________. welding circuit circuit
The steam supplied to operate a steam driven desuperheated
reciprocating pump is usually obtained from the steam line via a
11 1832 A __________. reducing station auxiliary exhaust line
The cut out valve at
Reducing station the outlet of the
Which of the following statements concerning the relief valves must be reducing valve
operation of steam pressure reducing valves is lifted by hand at least should be throttled
11 1833 C correct? once a watch. when in operation.
Which of the problems listed would cause the
discharge temperature of an R-12 refrigeration Thermal expansion Suction gas heat
11 1834 C compressor to increase? valve frozen open. exchanger bypassed.
If it were necessary for you to frequently replace
the bearings of the condensate pump, the trouble a plugged water seal
11 1836 A could be the result of __________. misalignment line
A control action which produces a corrective
signal relative to the length of time the controlled
variable has been away from the set point, is
11 1837 A known as __________. integral action proportional action
With regards to pilot controlled pneumatic
regulating valves, the spring force of the maintain the value of
regulating valve should be adjusted to maintain the required the manipulated
11 1838 D __________. system set point variable
The lines of new
welding should,
When renewing only a portion of an entire hull The insert plate where possible, lie in
plate with an insert plate, which of the listed should cover at least existing lines of
11 1839 A guidelines should be followed? one full frame space. welding.
An O-ring seal in a hydraulic system will begin to
leak when it has lost its interference fit due to compression set or
11 1840 A __________. wear low fluid pressure
When arc welding, the flux that covers the reduce metal fatigue
11 1841 C electrode is used to __________. control penetration and warpage
Some heavy duty screwdrivers are made with a allow it to be used as prevent the shank
11 1842 D square shank to __________. a pry bar from bending
tightening or
An offset screwdriver is best used for tightening Allen head loosening 'offset type'
11 1855 D __________. screws only machine screws
If the shaft packing for a centrifugal pump requires
replacement more frequently than normal, a worn mechanical
11 1856 A possible cause may be __________. worn bearings seals
The ratio of output response to a specified change
11 1857 C in the input is known as __________. primary feedback deviation
To prevent air pockets from forming in a
centrifugal pump suction line installed angled from centerline above the
normal, any gate valve should be installed with bonnet above suction suction pipe
11 1858 D the __________. pipe centerline centerline
The bleeder plug, or docking plug located on a provide a secondary
motor vessel double bottom tank is used to indicate when the means of tank
11 1859 D __________. tank is pressed up sounding
A Coast Guard issued engineer's license may be the violation of a the commission of an
11 1869 D suspended or revoked for __________. narcotic drug law act of misconduct
Traps in plumbing drains are designed to help drain noises in the drains clogging at the
11 1881 D prevent __________. living quarters toilets
cause liquid to be
trapped in between
the gear spaces as maintain tolerances
The purpose of the crescent found in the the gear passes the between the drive
11 1882 A illustrated internal gear pump is to __________. crescent and internal gears
The amount of fluid friction or internal friction
inherent in a mineral lubricating oil is reflected as
11 1883 B a measure of its __________. specific gravity viscosity
The purpose of chill shocking an evaporator is to prepare for a stress relieve the
11 1892 C __________. hydrostatic test tubes
If the speed of a drill is too great, the drill will
11 1893 C __________. cut faster cut slower
A thermostatic expansion valve is properly
controlling evaporator superheat. Adjusting this
valve to lower the superheat will result in a/an evaporator pressure evaporator coil over-
11 1894 B __________. decrease feed
The manipulated
variables are
adjusted only from
the input demand Another term
signals without commonly used in
In an automated control system, which of the monitoring the outlet conjunction with this
following statements would apply to any type of conditions or type of system is
11 1918 C closed loop system? variables. 'feed forward.'
A knocking sound emitted from an unloaded air damaged intake excessively tight
11 1919 D compressor is probably caused by __________. valves mounting bolts
Increasing the
High conductivity of absolute pressure of
the distillate indicates the shell will increase
Which of the following statements is true distillate salinity is the distiller's
11 1920 A concerning low pressure distilling units? excessive. capacity.
A Coast Guard engineer's license can be failure to attend having your wages
11 1939 C suspended or revoked for __________. safety meetings garnished
The process of boiling seawater in order to
separate it into freshwater vapor and brine is
11 1940 C usually defined as __________. dehydration condensation
The face, seat, and
sealing strip may be
repaired or replaced
The splash guard in an emergency
Which of the following statements is true remains stationary in situation without
concerning the shaft seal shown in the relation to the drawing the shaft or
11 1941 D illustration? rotating shaft. drydocking.
If the cutting edges of a drill are ground at
11 1943 B different angles, the __________. drill will not cut hole will be oversized
maintain liquid
refrigerant at the maintain a preset
The purpose of the low pressure cutout switch is suction of the suction pressure to
11 1944 C to __________. compressor the compressor
Failure of the steam pressure reducing valve to frictional losses low pressure in the
deliver proper steam pressure could be caused by downstream of the steam supply to the
11 1946 B __________. valve valve
changing pump
discharge pressure in
Overheating of a hydraulic system may be a result response to normal
11 1960 C of __________. load variations a high oil level
Condensate must be drained periodically from the second stage oil sump
11 1961 C air compressor receivers to prevent __________. cylinder lockup contamination
When a flash-type evaporator is to be secured for
an extended period of time, the entire unit should completely filled with filled with descaling
11 1962 D be drained, cleaned, and __________. saltwater compound
Rapid wear on the extreme outer corners to the
cutting edges of a drill bit is the result of the drill too much cutting not enough cutting
11 1963 C having __________. speed speed
The oil separator (trap) used in a large shipboard compressor
refrigeration system would be located between the discharge valve and condenser and the
11 1964 A __________. the condenser receiver
Which of the following types of nuts would be best
suited to use when it is important that a nut not
11 1965 D work itself loose due to vibration? Square nut Wing nut
What type of material is used to construct the
11 1966 D rotor of the pump illustrated? Monel Brass sheet
any two pressures atmospheric
In pressure measurement, absolute pressure is measured with pressure and
defined as the difference in pressure between respect to a common barometric pressure
11 1969 D __________. reference at a given point
According to Coast Guard Regulations (46 CFR),
a fresh water evaporator is classified as a/an
11 1970 D __________. auxiliary boiler fired pressure vessel
The nameplate of a reciprocating pump lists the
following dimensions: "7 X 6 X 4". The diameter
11 1971 D of the liquid cylinder is __________. 4 inches 7 inches
Which of the following nondestructive testing
methods can be used to detect a suspected
11 1972 C subsurface defect in a tail shaft liner? Dye penetrant Magnetic particle
the number of
the amount of milligrams of
The neutralization number obtained from a test mineral and metallic potassium hydroxide
sample of lubricating oil will tell you precisely solids that will not used to neutralize a
11 1973 B __________. burn measured sample
An oil separator is a device used to remove oil
11 1974 C from the __________. liquid refrigerant receiver
adding small
Purging air from a hydraulic system is necessary amounts of oil to the the system has been
11 1977 C when __________. system overheated
The impeller is
Which of the following statements concerning A pumproom is not located at the upper
11 1980 A deep well cargo pumps is correct? necessary. end of the shaft.
Joiner bulkheads on a MODU provide
11 1981 A __________. compartmentation watertight integrity
remains centered to
allow the servo pump
discharge to build
When the port power unit is started, as shown in pilot pressure to shift shifts to direct port
the illustration, the unloading valve "C" the port unit replenishing flow to
11 1986 C __________. distributor valve the service tank
A screwdriver should never be used as a
11 1987 D __________. pry bar chisel
The converter pneumatic control bypass valve,
shown in the illustration, receives it low pressure hot water return
11 1988 A signal from the __________. manifold converter
Which of the following conditions will prevent a Friction losses as a
shipboard pump from achieving its maximum Leaks developed in result of improperly
11 1989 D suction lift? the suction piping. sized pipe.
Structural bulkheads on a MODU are usually
11 1991 B __________. continuous watertight
Plug valves installed in hydraulic systems are main supply line variable flow control
11 1992 C most suitable for use as __________. throttle valves valves
allow an alternate
main pump to start in prevent either main
the fully loaded pump from being
Hydraulically, servo-operated, automatic, change condition thus hydraulically motored
over valves, utilized in a two ram hydraulic developing when idle by cross
11 2002 B steering gear, serve to __________. immediate full torque pressure flow
Ball peen hammers are sized according to their
11 2003 B __________. overall length head weight
provide a positive
flow of water through
assist in flushing out the stern tube for
all packing strips lubricating, cooling,
The stern tube flushing connection can be used to when renewing and flushing when
11 2006 B _________, packing underway required
A Bourdon tube-type steam pressure gage is fitted
with a siphon loop to prevent damage from the
11 2008 D direct effects of __________. pressure shock uneven expansion
The size of the discharge ring used for the
efficient operation of a disk type purifier is rated capacity of that viscosity of the oil
11 2009 D dependent upon the __________. purifier being purified
Which of the following problems will occur if a Contamination of the The lube oil will not
disk-type centrifugal lube oil purifier contains lube oil by be subjected to the
insufficient sealing water prior to admitting oil flow emulsification will proper centrifugal
11 2026 D to the bowl? result. force.
flash chamber
pressure pressure
being lower than the temperature being
saturation pressure higher than the
Feed water supplied to a flash type distilling plant corresponding to the evaporation
will flash to vapor in the first-stage due to feedwater temperature of the
11 2029 A __________. temperature supplied feedwater
Stanchions prevent the entire deck load on a
11 2031 C MODU from being carried by the __________. bulkheads stringers
The Phillips screwdriver has a blunt end and
11 2032 C flukes with an angle of __________. 10° 45°
An important consideration in selecting a
lubricating oil for use in a refrigeration compressor have a high viscosity mix readily with
11 2034 D is for the oil to __________. index refrigerant
number of threads
angle formed by divided by the length
With regards to the American National Screw adjacent flanks of a of the threaded
11 2042 C Thread nomenclature, 'pitch' is the __________. thread portion of the screw
The presence of scale and dirt on the saltwater
side of a lube oil cooler is usually indicated by clogged lube oil seawater leaking into
11 2043 D __________. strainers the lube oil system
11 2044 C One refrigeration ton is equal to __________. 180 BTU/hr 2,000 BTU/hr
A leaking suction valve in the second stage of a
two stage, high pressure, air compressor can second stage first stage discharge
11 2045 B cause excessively high __________. discharge pressure pressure
shaft "K" will rotate
When the steering gear receives a command shaft "K" will rotate, causing "M" to rotate
signal for a 15° right rudder, during the initial but its output to "M" reducing linkage
11 2046 A period of movement of the rudder __________. will be nullified length
The tool used to remove a ball bearing from the
11 2047 B shaft of a motor is called a __________. slugging wrench gear puller
Fabric type packing, such as flax or hemp, is best
11 2048 A suited for __________. low temperature use high temperature use
Water cooled
Which of the following statements is true Raw water is the exhaust elbows
11 2053 D concerning a radiator type heat exchanger? cooling medium. remove the heat.
How much heat can a 5 ton refrigeration unit
11 2054 A remove from a refrigerated space? 60,000 BTU/hr 80,000 BTU/hr
Leaking valves in an air compressor can be a excessive discharge abrasion, dust, and
11 2055 B result of __________. pressure dirt
Heat exchanger tubes can be protected against metallic packing on fiber bushings in the
11 2063 D erosion and abrasion by the use of __________. the inlet end ferrules
maintain good
Steam supply piping to deck machinery is turbulent free steam prevent superheating
11 2088 C insulated in order to __________. flow through the pipe of the steam
Theoretically, there is
Which of the following statements is true no limit to shut off Theoretically it is self
11 2099 D regarding a positive displacement rotary pump? head pressure. priming.
Rapid fluctuation of the last effect shell vacuum in
a submerged tube evaporator can cause erratic air ejector air leaks in the tube
11 2101 D __________. operation nest
In a heat exchanger, excessive fluid velocity waterside deposit
11 2102 A should be avoided to prevent __________. erosive tube failure buildup
compensate for
Compensated flow control, or constant flow valves major leaks in the maintain the original
11 2103 C are used in hydraulic systems to __________. system fluid viscosity
An air conditioning system, required to remove
from 33,000 to 35,000 BTU per hour, should have
11 2104 D a minimum capacity of __________. 1.5 tons 2.0 tons
faulty operation of
Carryover in a flash type distilling plant can be a the brine overboard a pressure drop
11 2105 A result of __________. pump through the loop seal
compressor would air receiver pressure
If a ship service air compressor failed to unload, dangerously would be excessively
11 2106 C the __________. overspeed low
If the controlled system temperature downstream
of the valve shown in the illustration, decreases
below the set point, which of the listed actions will Stem "C" moves Power piston "H"
11 2107 C occur? down. moves up.
If a centrifugal pump develops insufficient
discharge pressure as a result of worn wearing
rings, which of the following corrective actions is Throttle in on the
11 2108 A required? Replace the rings. discharge valve.
using a positive
Accidental flooding of the engine room bilges stop-check valves displacement
through the bilge system is prevented by installed in the bilge reciprocating bilge
11 2109 A __________. suction manifolds pump
When the compressed air reservoir is placed in
line with an air compressor and is used as an frequently drained of
11 2110 B aftercooler, the reservoir must be __________. fitted with a manhole condensed water
be permissable
without the
knowledge and
Major repairs or alterations affecting the safety of not be made without approval of the
small passenger vessels of less than 100 gross the knowledge and Officer in Charge of
11 2116 A tons shall __________. approval of the OCMI Marine Inspection
If there is a sudden drop in the capacity of a
reciprocating air compressor, you should check for broken compressor worn piston rings or
11 2119 A __________. valves cylinder liners
The static suction head of a horizontal centrifugal discharge liquid level discharge liquid level
pump, is the difference in elevation between the and the suction liquid and the pump
11 2132 C __________. level centerline
A drilled hole is accurately finished to size with a
11 2133 D __________. center drill finish drill
In a refrigeration plant, one purpose of the cool the refrigerant superheat the
11 2134 C receiver is to __________. gas refrigerant liquid
In the radial piston pump shown in the illustration,
oil will enter the cylinder as the piston travels from
11 2135 A position __________. 1 to position 2 2 to position 3
illuminated
automatically and
Emergency lighting on small passenger vessels of illuminated at all actuated upon failure
less than 100 gross tons for lounge areas below times while vessel is of the main lighting
11 2136 B the main deck shall be __________. underway system
In the spring-loaded pressure reducing valve
illustrated, the auxiliary valve "D" is closed by
11 2137 C __________. diaphragm "E" mechanical linkage
fitting depressors
When air compressors are arranged for automatic which hold the
operation, the cylinders can be unloaded during bypassing the suction valve plates
11 2138 D starting by __________. discharge to suction on their seats
If a higher than normal water level is observed
through the inspection port of a flash evaporator, a leak in the
11 2139 C you should suspect __________. feedwater heater improper vacuum
The motor operated valve, shown in the
illustration, is represented by item number
11 2140 A __________. 1 2
Reciprocating air compressor bearing failure may a misaligned overtightened drive
11 2142 D result from __________. crankshaft belts
a continuous
Each vessel designed to carry more than 49 longitudinal
11 2157 B passengers must have __________. watertight bulkhead a collision bulkhead
The pressure side of the radial piston hydraulic
motor as shown in the illustration, is aligned to
11 2158 A piston number __________. 1 2
When shifting suction from one fresh water tank to
another, if the fresh water pump loses suction you loosen the
11 2160 B should___________. mechanical seal vent the pump casing
High salinity distillate being discharged from a maintaining the
flash-type distilling plant may be the result of proper distilling plant carrying the brine
11 2161 C __________. heat balance level below normal
Allowances may be made for the expansion and
contraction in piping by the use of expansion
11 2162 D joints or __________. unions retractable flanges
For any given volume of compressed air produced increase the power decrease the power
by a multistage air compressor, interstage cooling required for required for
11 2163 B will __________. compression compression
In the illustrated heating system, what is the
maximum height the heater should be mounted
11 2165 C above the deck? 5" 6"
fine mesh screening baffles installed
Solid contaminants are prevented from entering placed around the without limber or
the main lube oil system by way of the main pump suction line in lightening holes to
11 2166 C engine sump, through the use of __________. the sump trap the particles
square of the
The brake horsepower of a centrifugal pump will diameter of the diameter of the
11 2188 C vary directly as the __________. impeller impeller
In the illustrated schematic, the device used to
replace the six-way valve, as found on many older
type steering gears, is the component labeled as
11 2189 A __________. "A" "B"
Which type of Marine Sanitation Device (MSD) is
used solely for the storage of sewage and
flushwater at ambient air pressure and
11 2191 C temperature? Type I Type II
Any unusual, or new vibration in the hull or
propeller shafting can be an indication of
11 2192 D __________. clutch slippage overheated bearings
A reheater in an air conditioning system functions control inlet air control inlet air
11 2194 D to __________. temperature volume
Oiling a file as a rust preventative may cause
11 2195 B __________. overheating pinning
For cutting cast iron or soft steel, the proper
11 2196 A hacksaw blade should have __________. 14 teeth per inch 18 teeth per inch
An air tank rusts out, explodes and causes $
(USA) 24,000 damage to the engine room. By
law, this accident is required to be reported to the owner or his the insurance
11 2198 C __________. agent underwriter
"H" to move towards
"I", the pressure in
"H" to move away "M" to increase, "K"
If the suction pressure increases to a capacity from "I", the pressure to move down, and
controlled compressor used in a multi-box in "M" to drop, "K" to "S" to move down
refrigeration system, the actions of the unit shown move down, and "V" against the force of
11 2199 D in the illustration should cause __________. to move "S" upwards "V"
It senses
temperature for use It is used to maintain
In the device shown in the illustration, what is the in the temperature liquid level one inch
11 2200 D function of item "6"? control circuit. below item "8".
'Respiratory heat' is a term applied primarily to
11 2203 A which of the following cargoes? Fresh vegetables Meat
To prevent the unnecessary loading of an air
conditioning system while maintaining the admit only enough
designed dry bulb temperature and relative fresh outside air to reduce the air
humidity in an air conditioning system, you should provide proper reheating system
11 2204 A __________. ventilation load
Which of the files listed will have coarsely spaced
11 2205 C teeth? Second cut Dead smooth cut
If the signal input to 'P4' is 48psi, and the supply
pressure is 50 psi, the output pressure at 'P1', as
shown in the illustration, will be equal to
11 2208 A __________. 0 psi 10 psi
Screwdrivers designed for electrical use should longer than normal larger than normal
11 2210 D have __________. shanks shanks
Which of the files listed is produced with two safe
11 2211 B edges? Mill Pillar
The oily-water
The oily-water mixture enters
mixture enters through the pressure
through valve "14" control valve "2" and
What is the normal direction of flow through the and exits with the exits with the
device shown in the illustration while operating in processed liquid processed liquid
11 2222 D the processing mode? through valve "4". through valve "14".
excessive engine
Unusual hull, or propeller shaft vibrations can be speed in shallow slop in a hydraulic
11 2223 A caused by __________. water clutch
If a refrigeration compressor in a multi-box system high pressure switch
runs continuously, the cause might be a stuck in the closed clogged mechanical
11 2224 C __________. position scale trap
The barge shown in the illustration is 40' X 20' X
10'and weighs 22.9 long tons when empty. The
theoretical maximum amount of machinery and
cargo which may be installed or loaded is
11 2226 B __________. 182.9 long tons 205.6 long tons
The terms rough, coarse, bastard, second cut,
smooth, and dead smooth refer to the distance between the
11 2227 D __________. parallel cuts of a file size of the file
By which of the listed methods may heat be
11 2228 D transferred from one body to another? Radiation Convection
Which of the screwdrivers listed is designed with
the shaft made from double coil wire or tightly
11 2229 C coiled steel? Square shank Ratchet
cause the file to slide
across the work and
A file coated with oil and stowed away will cause the file to prevent fast, clean
11 2230 D __________. overheat cutting
Determine the volume of vapor compressed per
minute per ton in a simple saturated refrigeration
system using the table shown in the illustration.
The evaporator temperature is 0°F, with a
11 2231 D condensing temperature of 120°F. 1.07 cu ft/min/ton 4.75 cu ft/min/ton
The length of a file is always measured exclusive
11 2232 B of the __________. edge tang
Remove the power
head from the unit,
heat the bulb with a
Heat the bulb by torch while using a
using a halide torch scale to measure the
Which of the following statements describes the or similar device and distance the
accepted method for testing a thermostatic observe the valve diaphragm has
11 2235 D expansion valve? stem movement. moved.
An operating refrigeration system uses the device
shown in the illustration. The high pressure gage
indicates an abnormal decrease in the head item "M" being
pressure. The probable cause can be related to fouling of the unit screwed up to the
11 2236 A __________. labeled as "I" stops
The dew point is reached when the wet bulb equal to the dry bulb twice the dry bulb
11 2254 A temperature is __________. temperature temperature
the suction line will the suction line will
be abnormally cold be hot due to a
and liquid may slug reduced amount of
If the superheat value of a thermostatic expansion back to the refrigerant returning
11 2255 A valve is set too low, the __________. compressor to the compressor
an insufficient
all of the system amount of liquid will
If a thermostatic expansion valve is adjusted for liquid will flow to the be fed to the
11 2265 B too high a superheat value __________. evaporator coil evaporator
11 2267 D Pinning is often caused by __________. dropping the file chalking the file
Officer in Charge,
According to regulations (46 CFR), who may grant Marine Inspection Commandant (G-
11 2275 B an extension of the tailshaft examination interval? office MOC)
thermostatic,
evaporator,
In a refrigeration system, the valve shown in the refrigerant regulating thermostatic, back
11 2276 C illustration is used as a __________. valve pressure regulator
It is necessary to 'chalk' a file when the metal you
11 2277 C are filing is __________. mild steel stainless steel
The dashed line to the illustrated pump is the pump relief valve pump capacity
11 2289 C __________. outlet to the sump control feedback loop
The components indicated as "7" and "8" as
shown in the illustration, are known as the outlet weir and outlet inlet weir and inlet
11 2290 B __________. baffle baffle
An automatic valve,
What device shown in the illustration is used to item #14 opens to A rupture disc, item
prevent excessive internal pressures within the prevent excessive #16 ruptures causing
11 2309 C unit during its operation? pressure. the pressure to drop.
When mounted in a hand held hacksaw frame,
which of the blades listed could cut smoothly
11 2310 C through a metal file? Wave set Hardened
Independent remote
control of pitch is to
be provided at or
near the oil
A pitch indicator is to distribution box.
be fitted on the Tests of its operation
navigation bridge for are to be performed
Which of the statements listed accurately applies vessels 400 gross in the presence of
11 2315 D to controllable pitch propeller systems? tons and above. the Surveyor.
of approved
with approved incombustible
incombustible materials, but need
materials and made meet no
According to Coast Guard regulation (46 CFR), an intact from deck to requirements relative
"A" class division, bulkhead or deck shall be deck and to shell or to the passage of
11 2316 D constructed __________. other boundaries flame
Two sets of
The fans will contactors vary the
exclusively operate in operating voltages of
the high speed range four winding
The evaporator fans of the refrigeration system as when both the 'EFH' configurations,
shown in the illustration are two speed. Which of and the 'EF' allowing dual speed
the following statements properly describes the operating coils are capabilities for two
11 2332 D factors controlling the speed of the fans? energized. separate motors.
The term referring to the amount or degree the
teeth of a hacksaw blade are pushed out or
canted from the blade center is known as
11 2333 A __________. set pitch
A lower thermostatic temperature setting will
provide a desired degree of comfort in a room low relative humidity triple banded squirrel
11 2334 D where __________. is maintained cage fans are used
The valve labeled "4", for the device shown in the oily water inlet
11 2335 C illustration, is the __________. pump suction valve regulating valve
of approved
with approved incombustible
incombustible materials, but need
materials and made meet no
According to Coast Guard regulation (46 CFR), a intact from deck to requirements relative
"C" class division, bulkhead or deck shall be deck and to shell or to the passage of
11 2336 B constructed __________. other boundaries flame
The teeth of a file may 'clog up' with metal filings
and scratch your work. This condition is known as
11 2337 B __________. binding pinning
rate at which
If the superheat value of the thermostatic condensation occurs
expansion valve is adjusted too high the box temperature will on the evaporator
11 2340 C __________. continually rise coils will increase
A refrigeration system has an evaporating
temperature of 40°F, and the liquid is subcooled
to 90°F. Calculate the weight of refrigerant
circulated per minute per ton using the table
11 2341 D shown in the illustration. 1.97 lb/min/ton 2.41 lb/min/ton
What maintenance may be carried out on a The thermal bulb The rate action may
11 2345 D thermostatic expansion valve? may be recharged. be increased.
protected by a relief
valve set to relieve at
a pressure not
subject to annual exceeding 110
hyrdrostatic tests to percent of the
Each pressure vessel containing refrigerants, be performed in the maximum allowable
which may be isolated, shall be __________. (46 presence of a marine working pressure of
11 2359 D CFR) inspector the vessel
The type of tooth set on a hacksaw blade where
two adjoining teeth are staggered to the right, then
two to the left, and continue to alternate in this
11 2360 B manner is known as __________. Alternate Double alternate
the accumulation of
the air will air in the top of the
accumulate in the top unit will be sensed as
If air is continuously allowed to enter the device of the unit and will be oil by item "6" and
shown in the illustration while operating in the manually vented off initiates the oil
11 2380 B processing mode __________. using valve "2" discharge mode
These abrasion
The transit washers resistors prevent
transmit the rotary damage to the
motion of the cap surface around the
What is the primary function of the devices shown screw to the bolt holes when
11 2381 D in the illustration? actuating assembly. tightening the bolts.
Water flow is established through the unit shown "E" is moved from the "A" is tilted off of its
11 2396 D in the illustration when __________. position shown seat
It senses
In the illustrated device, what is the function of the temperature for use It is used to maintain
short sensing element attached to "S" in figure in the temperature liquid level one inch
11 2433 D "A"? control circuit. below the wier plate.
At ambient temperature and atmospheric
11 2434 C pressure, R-12 is a/an __________. corrosive liquid flammable gas
The reading indicated on a vernier micrometer
caliper scale is .2928 inches. Which of the figures
11 2436 A in the illustration represents this reading? Figure B Figure C
The reading on the micrometer scale shown in
11 2437 D figure "II" in the illustration is __________. 0.321 inch 0.350 inch
What is the reading of the vernier caliper scale
11 2438 B shown in figure "F" in the illustration? 1.719 inch 1.723 inch
Which of the ilustrated figures represents the use
11 2439 C of a right hand roughing tool? Figure P Figure S
11 2440 D Which chemical symbol represents ammonia? AM3 AMn3
If a vessel is not provided with duplicate service
systems, which of the systems listed will satisfy
the regulations if serviced by two pumps? (46
11 2441 D CFR) Main condensate Fuel oil service
A centrifugal pump gradually develops insufficient
discharge pressure. What corrective action is Replace the wearing Throttle in on the
11 2443 A required? rings. discharge valve.
differential pressure
The low pressure cutout switch will cause the expansion valve between the cut-in
compressor in a refrigeration system to short cycle thermal bulb loses its pressure and cutout
11 2444 B if the __________. charge pressure is too small
available horsepower
speed output of the at the "B" end would
"B" end would increase in
If the "B" end of the hydraulic transmission increase in proportion as the
illustrated, were provided with a variable position proportion as the tilting box angle
tilting box, and the 'A: end displacement were to tilting box angle would approach zero
11 2445 A be constant, the __________. would approach zero stroke
Which piping material is recommended to be used
in extra heavy duty sizes in ammonia refrigeration
11 2446 A system construction? Steel Monel
it will be necessary to
use approved a combustible gas
petroleum base indicator must be in
solvents and a gas use during the
11 2447 D When cleaning out a P-tank __________. mask cleaning process
What is the reading of the vernier caliper scale
11 2448 B shown in figure "B" in the illustration? 3.7850 inch 5.3700 inch
If your skin comes in contact with liquid ammonia contact physicians apply an antibacterial
11 2449 C refrigerant, you should immediately __________. health care ointment
The system pressure
should be prevented
The vessel must be from exceeding the
drydocked and the maximum allowable
It is necessary to test the hydraulic system of a propeller removed operating pressure
controllable pitch propeller. According to 46 CFR when performing this set forth by the
11 2451 C what should be done? test. manufacturer.
Using the information given, solve for "H", "I", and H = 33.0 BTU/lb, I = H = 33.0 BTU/lb, I =
"J" in the table accompanying the psychrometric 15.5 cubic ft/lb, J = . 13.97 cubic ft/lb, J =
11 2452 C chart shown in the illustration. 0127 lbs/lb 78.0 grains/lb
Which materials should be used for ammonia
refrigeration system evaporator cooling coil Copper tubing with Copper tubing with
11 2453 C construction? copper fins aluminum fins
allow a uniformly
heated 60 c.c.
force a uniformly sample of oil to
heated sample of oil gravitate through the
by applied pressure, bottom orifice, using
through the bottom the time as a
orifice with in a measurement
11 2458 B The illustrated device is used to __________. specified time viscosity
The pressure in a high pressure refrigeration
system about to be opened for repair should be
11 2459 D __________. 1 to 2 psig 4 to 7 psig
unfired pressure
vessel in which
energy is stored
device in which bilge under high pressure
water may be stored in the form of a gas
According to Coast Guard Regulations (46 CFR) prior to being or a gas and a
11 2471 B an accumulator is a/an __________. pumped ashore hydraulic fluid.
collects
The receiver used in a refrigeration system stores liquid noncondensable
11 2477 A __________. refrigerant gases
speed output of the available horsepower
Theoretically, if the "B" end of the hydraulic "B" end would at the "B" end would
transmission illustrated were provided with a decrease in increase in
variable position tilting box, and the "A" end proportion as the proportion as the
displacement were to be constant, the tilting box would tilting box would
11 2478 D __________. approach zero stroke approach zero stroke
Satisfactory venting
Recirculation will not of the pump casing
What would occur if "A" shown on the illustrated be available at low would not be
11 2479 C pump is closed? flow. possible.
is designed to
A P-tank system, as used on oilfield supply boats must be kept free of transfer viscous
11 2511 A __________. moisture and water liquids
The petcock "B" installed on the illustrated pump vent the casing at supply sealing water
11 2519 A is used to __________. start-up to the stuffing box
Inhalation of high concentrations of CFCs may
11 2520 D have which of the following effects? drowsiness loss of concentration
The chemical formula for ozone is represented as
11 2521 C __________. O O2
Using the psychrometric chart shown in the
illustration, determine the quantity of heat
removed from one pound of air as it is cooled from
85°F at 80% relative humidity to 57°F at 70%
11 2522 C relative humidity? 12.2 BTU 17.2 BTU
refrigeration system
11 2523 C The device illustrated is used as a __________. packless valve quick closing valve
The device
determines whether The device is used to
the unit will be in the ensure that all
cooling, or heating returns go to the
What is the function of the device shown in the and defrost modes of compressor
11 2525 A illustration? operation. discharge.
control condensate
The function of the device illustrated is to control steam input to output from a heat
11 2527 B __________. a heat exchanger exchanger
compressor
solenoid valve is de- discharge pressure
energized and the acts on the right side
When the device shown in the illustration is in the valve assembly of the piston causing
11 2555 D defrost mode, the __________. moves to the right it to move to the left
Most freon refrigerants are originated primarily ammonia and carbon
11 2557 D from which of the following base molecules? dioxide ammonia and ethane
If solenoid "B" illustrated is energized, the pump should reverse cylinder should
11 2560 D __________. the direction of flow extend
If a block and tackle arrangement were rigged as
shown in figure "D" in the illustration, the amount
of force "P" required to hold the 266 pound load
11 2562 D stationary would be __________. 40 lbs. 53 lbs.
In a refrigeration system, the condenser cooling
water regulating valve is directly controlled by the temperature of the compressor
11 2564 B __________. cooling water discharge pressure
In a refrigeration system, the component installed
downstream of the thermal expansion valve is
11 2566 A called the __________. evaporator receiver
Globe valve - rising Gate valve - rising
11 2567 D What type of valve is shown in the illustration? stem stem
Refrigerant recovery cylinders are color gray top and yellow gray top and light
11 2568 D coded__________. lower body blue lower body
aerate the mud to
The purpose of nozzles in a liquid mud system is insure proper oxygen maintain the quality
11 2569 B to_________. content of the mud
air pressure in the
A pneumercator is an instrument used to indicate diesel engine starting phosphates in boiler
11 2570 C __________. circuit water
Movement of the material discharge hoses,
fluctuating P-tank air pressure and a light dust trail
from the receiving tank vent indicates a clogged discharge improper movement
11 2571 D __________. line of the weight material
In a liquid mud system, the sea valve must be a leaking sea valve any leakage can
tightly secured and not leak decreases stability of destroy the product
11 2576 B because___________. the OSV being transported
Test a sample to
insure that the
Which of the following steps should be taken Inspect tanks to emulsifying amines
before taking on a load of liquid mud for transport insure they are clean do not exceed a
11 2577 A to a MODU? and dry. STEL of 25 ppm.
sent to a designated
All refrigerant recovered from burned out small reclaimation facility contained in a
11 2589 A appliances must be __________. for processing refillable cylinder
Which of the following refrigerants is an interim
11 2591 D retrofit replacement for R-11? R-500 R-134a
The lathe tool shown as figure "Q" in the
illustration is commonly known as a/an left-cut, side-facing
11 2592 B __________. cutting-off tool tool
discharge the
Excess pressure used in a P-tank system will material at an
11 2593 A more than likely __________. rupture the P-tank excessive rate
self-contained
recovery devices
self-contained usually contain a
What differentiates 'system-dependent' and 'self- recovery devices can compressor, system-
contained' recovery devices in refrigeration only be used on large dependent recovery
11 2601 B systems? CGC and HCFC units devices do not
Overfilling a refrigerant container is extremely
dangerous because of the high pressures discharge pressure
generated. The generation of pressure is vapor pressure of the of the recovery
11 2603 C the_________. refrigerant compressor
An unenergized An unenergized
How do the modulating valves, found in some modulation valve is in modulation valve is in
container refrigeration systems, differ in operation the normally open the completely
11 2605 A from solenoid valves found in the same system? position. closed position.
All refrigeration systems must be protected with a
11 2607 C __________. high pressure cut-out refrigerant receiver
The hydraulic graphic symbol illustrated in Fig. B
11 2608 A is used to represent a/an __________. variable orifice piloted choke
Refillable tanks used to ship CFC and HCFC the United States
refrigerants or used to recover these refrigerants the United States Department of
11 2613 B must meet the standards of __________. Coast Guard Transportation
If you find an extremely large refrigerant leak
while using a halide torch, your flame will change from blue to 'flare up' and remain
11 2614 C __________. orange lighted
Solenoid valves used in refrigeration systems may normally open, de- normally closed,
11 2665 C be classified as __________. energized energized
If you have a simplex single acting reciprocating
pump making 160 strokes/minute, with a 5"
diameter cylinder, a 7" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 2666 D this pump? 183 gpm 91 gpm
If you have a duplex double acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 6" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 2668 D this pump? 54 gpm 81 gpm
considered by
inspection societies
to be more
dependable than the
The steering gear shown in the illustration, when more conventional
compared to the more conventional linear actuator less likely to sustain units due to the use
11 2672 C ram units is/are __________. oil leaks of the vane motor
The air compressor for a P-tank unit should be discharge moisture dry out fixed
operated for several minutes with its discharge formed during the discharge piping and
11 2673 D valves open to the atmosphere to __________. compression process hoses
In a chilled water air conditioning unit using a
reciprocating compressor, the refrigerating effect increasing chilled
of the primary refrigerant can be increased by increasing refrigerant water flow through
11 2674 C __________. pressure in the coil the cooler
A flat piece of thin sheet metal fastened to the
device illustrated, would most likely require the countersunk flat round head machine
11 2676 B use of which listed type of fastener? head, phillip screw screw
opening a drain
Moisture is removed from CFC-12 using a recycler bleeding petcock on the oil
11 2677 D by __________. noncondensables off separator
The type of heat indicated in section "2" in the
illustration is known as __________. I. latent
11 2678 B heat of fission II. latent heat of fusion I only II only
The thread machined on the device illustrated is one-eighth inch right- one inch, right-hand
11 2680 D a/an __________. hand national coarse national coarse
Of the four refrigerants CFC-11, CFC-12, HFC- lowest system highest system
134a, and HCFC-22; HCFC-22 operates at the pressure with the pressure with the
11 2681 B __________. lowest boiling point lowest boiling point
Disposable refrigerant cylinders may contain a
11 2683 A maximum amount of refrigerant of __________. 50 pounds 40 pounds
superheat of the gas
The expansion valve used in a refrigeration leaving the back pressure in the
11 2684 D system regulates the __________. compressor evaporator
The carbon ring of a refrigeration compressor
crankshaft mechanical seal is held in position
against the stationary ring by using a/an
11 2685 A __________. spring snap ring
If you have a simplex single acting reciprocating
pump making 160 strokes/minute, with a 4"
diameter cylinder, a 10" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 2686 B this pump? 131 gpm 33 gpm
"O" will be
hydraulically locked
in place even though
oil is returned to the
main pump from the "O" will rotate
left side of "N" and clockwise as oil is
If oil under pressure is supplied to the space the area to the right returned from the left
11 2687 B between "N" and "I" in the illustration __________. of "P" side of vane "N"
national coarse
11 2701 B The type of thread illustrated is a/an __________. acme thread thread
11 2766 B P-tanks are filled through the __________. discharge line pressurized fill line
All of the links in the last shot of anchor chain are
11 2767 C painted __________. yellow white
If you have a simplex single acting reciprocating
pump making 100 strokes/minute with a 6"
diameter cylinder, a 12" stroke with a volumetric
efficiency of 90%, what is the capacity of this
11 2768 A pump? 66 gpm 132 gpm
Before charging a refrigeration unit, the refrigerant flushed with clean purged with the
11 2824 B charging lines should be __________. refrigerant oil refrigerant
sufficient capacity to
contain all the lube
oil in the system
installation of baffles except for the
Design characteristics of lubricating oil sump to prevent excessive contents of the
11 2831 A tanks include __________. sloshing of oil gravity tank
When using the test set up shown in the illustrated the flame will turn a large flame is more
to find a leak in an evaporator coil, it is important blue in the presence sensitive than a small
11 2844 C to remember that __________. of a refrigerant flame
According to the Regulations, all escape hatches exterior side, in less exterior side only, in
and other emergency exits on small passenger than 2-inch letters at least 2-inch letters
vessels of less than 100 gross tons shall be 'watertight openning- 'emergency exit-keep
11 2871 D marked on __________. keep clear' clear'
If you have a duplex double acting reciprocating
pump making 200 strokes/minute, with a 5"
diameter cylinder, a 7" stroke and operating with
77% volumetric efficiency, what is the capacity of
11 2872 C this pump? 46 gpm 92 gpm
If you have a simplex single acting reciprocating
pump making 120 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
81% volumetric efficiency, what is the capacity of
11 2873 D this pump? 25 gpm 59 gpm
A cargo hold has been determined to have a
relative humidity of 80% and a dry bulb
temperature of 85°F. When the hold is closed and
the dry bulb temperature decreases, the relative
11 2874 B humidity in the space will __________. decrease increase
If you have a duplex double acting reciprocating
pump making 200 strokes/minute, with a 3"
diameter cylinder, a 4" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 2875 B this pump? 11 gpm 46 gpm
If you have a duplex double acting reciprocating
pump making 100 strokes/minute, with a 6"
diameter cylinder, a 7" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 2876 C this pump? 39 gpm 77 gpm
When a P-tank has been properly emptied, the decrease to 35-37
11 2878 C tank pressure will immediately __________. increase to 3-5 psi psi
If your vessel burns 8 tons of fuel per hour at 15
knots, how many tons per hour will it burn at 19
11 2879 B knots? 12.8 tons 16.3 tons
If you have a simplex single acting reciprocating
pump making 100 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 2880 A this pump? 110 gpm 28 gpm
If you have a duplex double acting reciprocating
pump making 110 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 2881 B this pump? 31 gpm 123 gpm
If you have a duplex double acting reciprocating
pump making 100 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 2882 C this pump? 22 gpm 44 gpm
If your vessel burns 8 tons of fuel per hour at 15
knots, how many tons per hour will it burn at 20
11 2883 C knots? 11.7 tons 10.7 tons
If solenoid "A" illustrated is energized, the pump should reverse cylinder should
11 2927 B __________. the direction of flow extend
If a block and tackle arrangement were rigged as
shown in figure "G" in the illustration, the amount
of force "P" required to hold the 294 pound load
11 2928 A stationary would be __________. 74 lbs. 90 lbs.
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 6"
diameter cylinder, a 13" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 2929 B this pump? 80 gpm 161 gpm
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 2930 C this pump? 86 gpm 343 gpm
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 7"
diameter cylinder, a 13" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 2931 D this pump? 108 gpm 434 gpm
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 5"
diameter cylinder, a 12" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 2932 A this pump? 102 gpm 51 gpm
Which of the lettered items correctly identifies the D-front seat, E-
parts of the refrigeration valve shown in the A-front seat, C-back normal outlet, and G-
11 2934 C illustration? seat, and D-seal cap valve packing
a cargo container
A water cooler with refrigerant system
An example of a small refrigeration appliance four pounds of containing 4.9 lbs of
11 2939 A identified as TYPE I, is __________. refrigerant refrigerant.
If you have a simplex single acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 4" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 2940 A this pump? 25 gpm 39 gpm
aerate the mud to clean the mud from
The purpose of nozzles in a liquid mud system is insure proper oxygen the bottom of the
11 2941 C to_________. content tank
If you have a simplex single acting reciprocating
pump making 110 strokes/minute, with a 5"
diameter cylinder, a 7" stroke and operating with
79% volumetric efficiency, what is the capacity of
11 2942 B this pump? 52 gpm 26 gpm
If you have a duplex double acting reciprocating
pump making 130 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 2943 C this pump? 79 gpm 237 gpm
The high pressure cutout switch will stop the a stoppage of
refrigeration centrifugal compressor when there is condenser cooling fouled condenser
11 2944 D __________. water flow tubes
Backflush water
would cause the oil The separator
accumulated in the operation would stall
If valve 'V2A' in the illustration does not open upper section of the as a result of oil
when the oily-water separator shifts into the oil tank to be forced remaining on the
discharge mode, which of the following back into the bilge longer probe of item
11 2960 B statements describes what would occur? spaces. "S".
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 5" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 2961 D this pump? 59 gpm 24 gpm
constant flow pump
In the hydraulic schematic illustrated, the pump constant flow gear of indefinite
11 2962 B symbol indicates the use of a __________. type pump construction
The amount of refrigerant in a storage cylinder is
11 2964 C measured by __________. pressure volume
A suction pressure
The position of the whose saturation
Which of the conditions listed would indicate the floating ball in the temperature is equal
refrigeration system shown in the illustration is receiver tank sight to the existing box
11 2965 D insufficiently charged? glass. temperature.
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 2966 C this pump? 626 gpm 134 gpm
will condense at a boils at a
temperature lower temperature equal to
Newly developed refrigerants, used to reduce than the boiling point the boiling point of
stratospheric ozone depletion, are sometimes of the componant the component with
refered to as azeotropic. This means that the withthe lowest boiling the lowest boiling
11 2967 D resulting liquid_________. point point
The operation of a P-tank depends upon fluidizing the dry bulk creating a liquified
11 2968 A __________. material barite slurry
If solenoid "A" of the valve illustrated is energized, extend with rate of retract with rate of
11 2973 C the cylinder will __________. movement controlled movement controlled
Dehydrators are usually located in the liquid line remove oil from the prevent icing of the
11 2974 B of refrigeration systems in order to __________. refrigerant expansion valve
The compressor in figure 4, if permitted to operate lose its volumetric damage the bearings
11 2978 B as illustrated will __________. efficiency of the motor
The direction and rate of rotation for the cab in the
hydraulic crane circuit shown, is controlled by the variable stroke pump main pump (item
11 2979 D __________. (item #3) #13)
slightly shifting the
hoist valve into the installation of a
The wire rope drum used in the illustrated position "I" to hold braking valve in line
hydraulic crane circuit is prevented from the load in a steady "K" to the hydraulic
11 2980 D accidentally paying out by __________. position motor
If solenoid "B" of the valve illustrated is energized, extend with rate of retract with rate of
11 2981 B the cylinder will __________. movement controlled movement controlled
If a block and tackle arrangement were rigged as
shown in figure "G" in the illustration, the amount
of force "P" required to hold the 362 pound load
11 2982 B stationary would be __________. 88 lbs. 91 lbs.
If you have a duplex single acting reciprocating
pump making 130 strokes/minute, with a 5"
diameter cylinder, a 4" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 2983 A this pump? 42 gpm 34 gpm
A liquid line solenoid valve controls refrigerant throttling the fully opening or
11 2984 B flow to the evaporator by __________. refrigerant closing
Which of the following conditions would indicate Normal discharge Frosting at the outlet
that the drier of the refrigeration system shown in pressure with an of the drier and an
the illustration became restricted and required abnormally low excessively high
11 2985 A replacement? suction pressure. suction pressure.
If you have a duplex double acting reciprocating
pump making 110 strokes/minute, with a 5"
diameter cylinder, a 12" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 2986 A this pump? 204 gpm 102 gpm
moving the dry barite using nozzles to
The operation of a P-tank depends upon with a liquid mud recirculate the dry
11 2988 C __________. pump bulk material
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 3"
diameter cylinder, a 4" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 2989 A this pump? 21 gpm 28 gpm
If you have a simplex single acting reciprocating
pump making 190 strokes/minute, with a 3"
diameter cylinder, a 12" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 2990 D this pump? 126 gpm 63 gpm
The amount of HCFC-123 in a storage cylinder is
11 2991 C measured by __________. saturation pressure volume
through flexible
hydraulic hoses via
the connection ports
Oil is supplied to the illustrated steering gear located in the top via the connections
11 3011 C __________. surface of "O" indicated as "J"
If you have a duplex single acting reciprocating
pump making 120 strokes/minute, with a 3"
diameter cylinder, a 4" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3012 C this pump? 19 gpm 7 gpm
Which of the listed conditions will occur if valve The water in the
"14" of the unit shown in the illustration is secured The water in the bilges will rise until
while the unit is operating in the processing bilges will continue to probe "6" activates
11 3049 D mode? be discharged. the separator.
If you have a duplex single acting reciprocating
pump making 120 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3050 A this pump? 68 gpm 56 gpm
The backlash of the gear illustrated is represented
11 3051 A by __________. G M
If you have a duplex double acting reciprocating
pump making 110 strokes/minute, with a 4"
diameter cylinder, a 6" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 3052 C this pump? 33 gpm 50 gpm
a pneumatically
a pressure vessel operated tank used
A 'P-tank' as used aboard oilfield supply boats is designed to transport transfer liquid drill
11 3062 C __________. liquid drill mud mud
by a pressure relief
valve when the
pressure exceeds the
when flushing the preset level, usually
A valve connected to the vent line labeled "C" in pressure tank with 42 psig (2.98
11 3081 D the illustration should be opened __________. firemain water kg/cm2)
In the hydraulic anchor windlass system
illustrated, pressurized fluid flow to provide
rotation of the wildcat is produced by
11 3082 A __________. A F
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 7"
diameter cylinder, a 8" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 3083 C this pump? 152 gpm 67 gpm
To test for a suspected large refrigerant leak from apply a soap solution
a refrigeration system in an enclosed area, you apply liquid ammonia to the area of the
11 3084 B should __________. to the suspected leak suspected leak
A low oil level maintained in an operating an internal leak
compressor, similar to the unit shown in the within the heat an improperly
11 3085 D illustration, may be caused by __________. exchanger operating filter/ drier
When arc welding, you can reduce the chance of using insulated wearing dry welding
11 3086 D a dangerous electric shock by __________. electrode holders gloves
The letter "H" of the illustrated gear, represents
11 3087 B the __________. tooth profile tooth fillet
The reading on the micrometer scale shown in
11 3088 C figure "C" in the illustration is __________. 0.301 inch 0.324 inch
If you have a duplex double acting reciprocating
pump making 130 strokes/minute, with a 5"
diameter cylinder, a 13" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 3089 A this pump? 267 gpm 134 gpm
If you have a duplex double acting reciprocating
pump making 170 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 3090 C this pump? 81 gpm 54 gpm
The illustrated shaft has an overall length of 42
inches. If the diameter of "E" = 4.75" and "F" = 6",
with an indicated radius of "R" = .125" and the
length of "X" = 8"; then the TPF (taper per foot) is
11 3091 A __________. 1.125 TPF 1.250 TPF
Operating pressure range for an oilfield supply
11 3092 B boat 'P-tank' generally varies from __________. 5-15 psi 15-40 psi
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 6"
diameter cylinder, a 9" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 3095 C this pump? 49 gpm 75 gpm
Before welding is permitted on a fuel tank, it must
11 3096 B be certified or declared __________. safe for personnel safe for hot work
as a gravity
discharge for the
to backflush the fluidized material if
A valve attached to line "H" in the illustration, pressure vessel with the discharge line
11 3125 C should be opened __________. jet air becomes clogged
It chemically reacts
Which statement describes the function of the It reduces the danger with acetone to
11 3126 A filler material used in acetylene cylinders? of explosion. produce acetylene.
The thermostat controlling a refrigerated cargo evaporator coil inlet the refrigerated box
11 3224 B box two-way solenoid valve senses __________. temperature temperature
If you have a duplex double acting reciprocating
pump making 250 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 3225 A this pump? 232 gpm 114 gpm
If you have a simplex single acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 13" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3226 C this pump? 327 gpm 163 gpm
The components labeled "T" in the illustration are take suction from all never point at the
11 3261 B arranged to __________. areas of the tank bottom of the tank
Three of the refrigerants covered under the low CFC-11, CFC-113 CFC-11, CFC-113
11 3262 B pressure system regulations are_________. and R-502 and HCFC-123
The device shown in the illustration is used to process sludge found process sludge found
11 3263 C __________. on motor vessels on steam vessels
The tool used to prepare copper tubing for the
11 3265 C installation of fittings is called a __________. swaging tool stretcher
If you have a duplex double acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
79% volumetric efficiency, what is the capacity of
11 3266 D this pump? 59 gpm 71 gpm
When adding oil to a refrigeration system, the compressor all air is purged from
precautions must be taken to ensure that suction pressure is the pump and
11 3284 B __________. not too high charging fittings
The discharge valves used in a refrigeration the reeds should be the reeds should be
11 3294 B compressor are leaking badly and __________. reground replaced
Which of the valves listed below is best suited for
11 3295 B throttling service? Plug Globe
If you have a simplex single acting reciprocating
pump making 170 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 3296 D this pump? 161 gpm 81 gpm
Which of the listed illustrated figures represents
11 3297 A the use of a lathe finishing tool? Figure P Figure S
equalize mud flow flush all parts of the
The branch circuits labeled "T" in the illustration through all of the tank with seawater
11 3298 A are designed to __________. nozzles during washdown
operating lever is
parallel to the pipe valve can have
center line when additional turns of
closed and packing added when
perpendicular to the there is pressure on
The valve illustrated is to be constructed so that pipe center line when either side of the
11 3299 C the __________. open valve disk
Gate valves should not be used for throttling as the pressure drop will air binding will
11 3310 D __________. be excessive develop
Your ship has steamed 1951 miles at 20 knots
using 580 tons of fuel oil. The distance remaining
to your next port is 1861 miles. If you increase
speed to 24 knots, how much fuel will be used to
11 3311 C reach that port? 569 tons 664 tons
If you have a duplex single acting reciprocating
pump making 110 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 3312 B this pump? 27 gpm 16 gpm
Which of the figures illustrated would be LEAST
11 3313 A desireable for use as a set screw? figure A figure F
The device shown in the illustration is a/an diesel engine motor vane type steering
11 3317 B __________. mount gear
Which of the statements listed is applicable to the It regulates the It regulates the
thermostatic expansion valve shown in the amount of superheat temperature of the
11 3334 C illustration? at the solenoid valve. refrigerated space.
If you have a duplex single acting reciprocating
pump making 150 strokes/minute, with a 6"
diameter cylinder, a 8" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3335 A this pump? 140 gpm 186 gpm
If you have a duplex double acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 13" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3336 C this pump? 163 gpm 425 gpm
If you have a duplex double acting reciprocating
pump making 120 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3337 A this pump? 135 gpm 68 gpm
If you have a simplex double acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 11" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 3338 D this pump? 10 gpm 39 gpm
Which of the figures illustrated is not suitable for
11 3339 B use as a hexhead set screw? figure C figure D
If you have a duplex double acting reciprocating
pump making 150 strokes/minute, with a 5"
diameter cylinder, a 11" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 3340 D this pump? 119 gpm 262 gpm
Continuing to hold
The pressure in down "E" will hold "A"
chamber "I" is greater off of its seat,
than the pressure in allowing water to
chamber "II", causing continuously flow
Which of the following statements would apply to part "A" to close off, from chamber "I" to
the principle of operation of the device shown in and force "C" into a chamber "III" via
11 3427 C the illustration? closed position. chamber "II".
The drains of lavatory sinks are fitted with P-type reduce water velocity create a strong
11 3432 D or S-type traps to __________. and minimize erosion siphon effect
If you have a duplex single acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
83% volumetric efficiency, what is the capacity of
11 3433 C this pump? 71 gpm 30 gpm
evaporator absolute
distillate produced in pressure would
If the orifice in the loop seal of a flash evaporator the second stage eventually equalize in
were to become significantly enlarged through would flow towards both stages to that of
11 3451 C erosion, the __________. the first stage the first stage
An automatic solenoid dump valve should be set
to trip if the evaporator produces distillate with salt
11 3452 D content exceeding __________. .05 gpg .15 gpg
If you have a simplex single acting reciprocating
pump making 140 strokes/minute, with a 3"
diameter cylinder, a 13" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 3453 D this pump? 105 gpm 52 gpm
In a refrigeration system, air is purged at the
11 3454 D __________. expansion valve filter/drier
If you have a duplex double acting reciprocating
pump making 180 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 3455 B this pump? 75 gpm 150 gpm
If you have a simplex single acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 3456 A this pump? 32 gpm 129 gpm
determine when
The function of item "6", as shown in the terminate the oil backflushing is
11 3460 C illustration, is to __________. discharge mode necessary
The component labeled "E" in the illustration is a high level equalization line with
11 3465 B __________. alarm/shutdown filter
If you have a simplex single acting reciprocating
pump making 140 strokes/minute, with a 4"
diameter cylinder, a 13" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 3466 B this pump? 186 gpm 47 gpm
If you have a duplex double acting reciprocating
pump making 250 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
79% volumetric efficiency, what is the capacity of
11 3467 C this pump? 75 gpm 132 gpm
If you have a duplex double acting reciprocating
pump making 330 strokes/minute, with a 3"
diameter cylinder, a 4" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 3468 D this pump? 39 gpm 52 gpm
A solenoid operated distillate bypass valve is excessively warm
installed in the discharge line between a distilling distillate from salty distillate from
plant and the potable water tanks to prevent entering the potable reaching the potable
11 3469 B __________. tanks tanks
If the distillate temperature is 150°F and the
distillate salinity is 0.35 grains per gallon, the
three-way solenoid trip valve should direct the
11 3470 D distillate to the __________. freshwater tanks reserve feed tank
Which of the following statements represents the Measures the Measures the
basic principle of operation of an electrical salinity hydrogen ion electrical resistance
11 3471 B indicator? concentration. of the water.
In a submerged tube evaporator, the automatic
solenoid dump valve will trip if the salinity exceeds 0.10 grains per 0.15 grains per
11 3472 D __________. gallon gallon
The compound gage shown in the illustration and
labeled as item "1" indicates a slight vacuum operating correctly
while the unit is in the oil discharge mode. The without the need for fouled and needs
11 3473 C separator is __________. any modification cleaning
The best time to check the oil level in the
compressor in a typical refrigeration system is
when the compressor is stopped after a long oil has had time to refrigerant has had
period of running. This is because the mix properly with the time to separate from
11 3474 B __________. refrigerant the oil
In the operation of a two-stage flash-type distilling
plant, which of the pumps listed should be vented Condenser
to the second stage shell in order to remove circulating water Feedwater heater
11 3475 C vapors from the pump suction? pump drain pump
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 6"
diameter cylinder, a 11" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 3476 A this pump? 206 gpm 378 gpm
If you have a simplex single acting reciprocating
pump making 150 strokes/minute, with a 5"
diameter cylinder, a 12" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3477 C this pump? 291 gpm 145 gpm
maintaining a
In the operation of a two-stage flash type distilling relatively high
plant, the rate of scale formation is greatly operating the unit at feedwater
11 3492 D reduced by __________. its rated capacity temperature
maintaining a
relatively high
The rate of scale formation in a flash type distilling operating the unit at feedwater
11 3493 C plant is greatly reduced by __________. its rated capacity temperature
In a refrigeration system, the thermal expansion near the evaporator near the evaporator
11 3524 A valve sensing bulb is located __________. coil outlet coil inlet
Some of the hazards of working with electric
power tools may be avoided if the operator they are properly eye shields and
11 3525 D insures that __________. grounded gloves are worn
If you have a duplex double acting reciprocating
pump making 190 strokes/minute, with a 5"
diameter cylinder, a 7" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 3526 B this pump? 85 gpm 170 gpm
If a bolt or stud were to break off flush at the Tap the bolt with a
surface, which of the listed actions must be done starting punch Heat the bolt with an
11 3527 C to begin the process of its removal? extractor. oxyacetylene torch.
If you have a simplex single acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 9" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3528 D this pump? 157 gpm 78 gpm
the extension cord is
When using a portable droplight, you should the bulb is protected yellow and clearly
11 3529 A always insure that __________. by a shield or guard marked
To properly use a lathe crotch center to drill an oil
hole in a bushing, you would mount the crotch
11 3530 C center in the __________. compound rest headstock
If you have a simplex single acting reciprocating
pump making 120 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3531 B this pump? 108 gpm 27 gpm
When using a wheel dressing tool to true up a lubricate the dressing operate the grinder in
11 3541 D grinding wheel, you should always __________. tool neutral
The operation of machining a uniformly
roughened or checked surface on round stock in a
11 3542 C lathe is called __________. checkering crosshatching
If you have a simplex single acting reciprocating
pump making 140 strokes/minute, with a 4"
diameter cylinder, a 8" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3543 C this pump? 115 gpm 57 gpm
A device used to hold open the refrigeration
compressor suction valve during starting is called discharge line
11 3544 B a __________. bypass cylinder unloader
If the point angle of a drill is less than 59°, the hole will be drilled too hole will take longer
11 3545 B __________. large to drill
If you have a duplex single acting reciprocating
pump making 150 strokes/minute, with a 5"
diameter cylinder, a 12" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3546 A this pump? 145 gpm 349 gpm
If you have a duplex single acting reciprocating
pump making 190 strokes/minute, with a 3"
diameter cylinder, a 13" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 3547 D this pump? 246 gpm 28 gpm
If you have a simplex single acting reciprocating
pump making 160 strokes/minute, with a 8"
diameter cylinder, a 9" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3548 C this pump? 35 gpm 70 gpm
As the drill bit is being fed into a metal work piece,
a squeaking sound from the tip of the bit indicates the bit is too large for the bit tip has not
11 3549 B __________. the hole been properly ground
11 3550 A In the illustration, line "D" is a/an __________. hidden line sectioning line
If you have a duplex single acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 3551 B this pump? 32 gpm 64 gpm
If you have a simplex single acting reciprocating
pump making 190 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
88% volumetric efficiency, what is the capacity of
11 3552 D this pump? 164 gpm 82 gpm
connect refrigeration
machinery and
associated piping
when there is a
The refrigeration piping component shown in the prevent vibration of misalignment
11 3554 C illustration is primarily used to __________. the compressor problem
Which of the following problems will cause a twist Improper lip Improper cutting
11 3555 D drill to cut improperly? clearance angle
If you have a simplex single acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 9" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3556 B this pump? 226 gpm 57 gpm
If you have a duplex double acting reciprocating
pump making 170 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 3557 A this pump? 48 gpm 40 gpm
If you have a simplex single acting reciprocating
pump making 120 strokes/minute, with a 5"
diameter cylinder, a 9" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3558 D this pump? 169 gpm 84 gpm
A dimension line, as used in a drawing or
blueprint, is represented by which of the figures
11 3559 C shown in the illustration? A B
The crosshatch design on the end of piece "3" in the piece is screwed the piece is made of
11 3566 C the illustration shown indicates that __________. into piece #2 mild carbon steel
If you have a duplex single acting reciprocating
pump making 170 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3567 C this pump? 30 gpm 119 gpm
If you have a duplex single acting reciprocating
pump making 140 strokes/minute, with a 6"
diameter cylinder, a 10" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 3568 C this pump? 268 gpm 81 gpm
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 3"
diameter cylinder, a 11" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 3569 A this pump? 45 gpm 167 gpm
If you have a simplex single acting reciprocating
pump making 120 strokes/minute, with a 6
diameter cylinder, a 11" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3570 A this pump? 74 gpm 297 gpm
control the
The primary purpose of a thermostatic controlled refrigerated bypass refrigerant
solenoid valve used in a multi-box refrigeration compartment flow to the
11 3584 A system is to __________. temperature evaporator
The illustration shown represents a blueprint of a rod with a tube with a broken
11 3585 A metal __________. conventional break out section
If you have a simplex single acting reciprocating
pump making 160 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 3586 B this pump? 526 gpm 132 gpm
If you have a simplex single acting reciprocating
pump making 170 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 3588 A this pump? 12 gpm 48 gpm
A 'centerline' depicted in a drawing or blueprint is
represented by which of the figures shown in the
11 3589 B illustration? A E
provide an
The purpose of the wearing ring used in the support the suction interference fit for the
11 3632 D illustrated pump is to __________. end of the impeller impeller
The function of seal cages, or lantern rings
installed in the centrifugal pump stuffing boxes, is
11 3633 D to __________. cool the shaft lubricate the packing
If the compressor is heard to knock while pumping
down the low side for repairs, this is an indication
11 3634 D of __________. worn piston rings faulty bearings
11 3635 C Internal pipe threads are cut with __________. dies reamers
When using a hand die to cut threads on brass
stock, the threads can be dry cut or may be
11 3637 C lubricated with __________. graphite and oil white lead
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
80% volumetric efficiency, what is the capacity of
11 3638 B this pump? 282 gpm 94 gpm
If you have a simplex single acting reciprocating
pump making 120 strokes/minute, with a 4
diameter cylinder, a 12" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3639 B this pump? 144 gpm 36 gpm
When pipe is properly screwed into a tapped hole, the pipe cannot be all the threads are
11 3640 D it will give the correct fit when __________. turned covered
A centrifugal pump designed to handle a liquid
with a temperature of 250°F or greater must be a semi-mechanical helical grooved
11 3641 D provided with __________. seal wearing rings
If you have a duplex single acting reciprocating
pump making 190 strokes/minute, with a 4"
diameter cylinder, a 13" stroke and operating with
77% volumetric efficiency, what is the capacity of
11 3642 A this pump? 103 gpm 336 gpm
The primary function of a centrifugal pump volute develop a high convert velocity to
11 3643 B is to __________. velocity liquid pressure
In the refrigeration system shown in the
illustration, which of the valves indicated should
11 3644 A be used to purge the system? A B
be more susceptible
be less susceptible to to shaft deflection
shaft deflection than than a similar pump
a similar pump with a with a single volute
A centrifugal pump with a double volute casing single volute casing casing operated
operated at greater than design capacity, will operated under the under the same
11 3645 A __________. same conditions conditions
If you have a duplex single acting reciprocating
pump making 160 strokes/minute, with a 6"
diameter cylinder, a 13" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3646 C this pump? 491 gpm 113 gpm
suction absolute
pressure greatly
If a centrifugal pump is driven by a constant speed exceeds
prime mover and produces a flow rate less than corresponding vapor
the designed specifications, the cause could be pressure of liquid excessive suction
11 3663 D __________. being pumped head pressure
One of the functions of the component labeled act solely as a heat act as a lube oil
11 3683 B "E", shown in the illustration, is to __________. exchanger sump
The refrigeration system valve illustrated has a
11 3684 B 'back seat', indicated by the part labeled '____.' B C
If you have a duplex single acting reciprocating
pump making 120 strokes/minute, with a 6
diameter cylinder, a 14" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3685 B this pump? 441 gpm 189 gpm
If you have a duplex single acting reciprocating
pump making 160 strokes/minute, with a 4"
diameter cylinder, a 11" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3686 C this pump? 229 gpm 42 gpm
work of isothermal
adiabatic work of compression to the
The volumetric efficiency of a reciprocating air compression to the brake horsepower of
11 3687 D compressor, is the ratio of the __________. indicated horsepower the motor
If you have a duplex single acting reciprocating
pump making 160 strokes/minute, with a 7"
diameter cylinder, a 8" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 3688 C this pump? 236 gpm 103 gpm
thermodynamic
thermostatic bellows bellows type steam
11 3689 A The trap illustrated operates as a __________. type steam trap trap
downward force of
the adjusting spring
"F" and the upward adjusting screw "G"
force of the reduced force exerted on the
The position of the controlling diaphragm "E", steam pressure adjusting spring "F"
shown in the illustration of the spring-loaded acting on diaphragm and the auxiliary
11 3690 A reducing valve, is determined by the __________. "E" valve "D" only
minimizes the
chance of return line
contamination
reduce fluid deposits from
The baffle plates installed in the oil reservoir of a turbulence at the entering the pump
11 3716 D hydraulic system serve to __________. pump suction suction
be arranged to
be taken directly off develop a maximum
In order for the hydraulic pump installed in a the reservoir bottom vacuum of
constant flow system to maintain adequate flow, without regard to approximately 10" of
11 3717 B the pump suction should __________. filters or strainers mercury
If you have a duplex double acting reciprocating
pump making 140 strokes/minute, with a 3"
diameter cylinder, a 13" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 3718 A this pump? 105 gpm 52 gpm
The instrument used to indicate the level of a fluid
11 3719 D in a tank is called a __________. fluid meter calorimeter
If you have a simplex single acting reciprocating
pump making 210 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
77% volumetric efficiency, what is the capacity of
11 3720 B this pump? 123 gpm 31 gpm
Figure "C" in the illustration, is an improperly right hand fitting
installed hose, with the restriction developed at being small than
11 3721 B the __________. required center of the hose
If you have a simplex single acting reciprocating
pump making 250 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
79% volumetric efficiency, what is the capacity of
11 3722 D this pump? 150 gpm 75 gpm
Which of the devices listed would be considered a Counterbalance Offset, two position
11 3730 B hydraulic system directional control valve? valve valve
an increase in the
continuous leakage number of the
Overheating of the oil in a hydraulic system can through the pressure hydraulic fluid film
11 3775 A be caused by __________. relief valve layers
If you have a duplex single acting reciprocating
pump making 160 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 3776 C this pump? 50 gpm 38 gpm
by a required
auxiliary steering
system under
emergency
conditions when
Coast Guard Regulations require that OSV's duplicated main by design at one-half
under 100 GT must have a steering system that is steering power astern speed without
11 3777 C capable of moving the ruddder __________. systems are provided damage.
If you have a duplex double acting reciprocating
pump making 170 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3778 A this pump? 519 gpm 259 gpm
In order to properly regulate the high side
pressure of a refrigerating system, using the
device shown in the illustration, adjustment should
be carried out by rotating the component labeled
11 3779 B as __________. I M
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 3781 A this pump? 22 gpm 89 gpm
In order to reduce the operating head pressure of
a refrigerating system using the device shown in "I" and rotate it
the illustration, you should use component counter clockwise "O" and rotate it
11 3782 D __________. (out) clockwise (up)
In order to raise the operating head pressure of a "O" should be rotated "N" should be rotated
refrigerating system using the device shown in the counter clockwise counter clockwise
11 3783 C illustration, component __________. (down) (down)
The item, labeled "F" shown in the illustration, will the total force above the working pressure
11 3787 A begin to lift to a higher position if __________. "H" is reduced in "N" is decreased
If you have a duplex double acting reciprocating
pump making 190 strokes/minute, with a 4"
diameter cylinder, a 8" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 3788 B this pump? 62 gpm 124 gpm
low discharge
If a hydraulic pump is overheating, the cause may excessive internal pressure and fluid
11 3789 A be __________. slippage in the pump flow
If you have a duplex single acting reciprocating
pump making 190 strokes/minute, with a 5"
diameter cylinder, a 12" stroke and operation with
75% volumetric efficiency, what is the capacity of
11 3790 C this pump? 349 gpm 73 gpm
Capacity control of a centrifugal refrigeration
compressor can be accomplished by varying the speed of varying the suction
11 3791 D __________. the compressor pressure
point of condensation
efficiency of the heat will be moved closer
If "E" is moved closer to the top of "B" as shown in exchanger operation to the steam inlet of
11 3803 B the illustration, the __________. will be increased the heat exchanger
a safety interlock
A fluid power system is considered to be fail-safe producing a
if a component failure will result in __________. continuous operation regulated shutdown
11 3805 D (46 CFR) of the system of the system
If you have a duplex double acting reciprocating
pump making 120 strokes/minute, with a 6"
diameter cylinder, a 11" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3806 C this pump? 149 gpm 273 gpm
pressure regulating
valves to insure mud by-pass valves
excessive pressure that protects a pump
The devices labeled "C" in the illustration, are does not damage the that fails when both
11 3807 C used as __________. manifold nozzles pumps are on line
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 7"
diameter cylinder, a 13" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3808 C this pump? 301 gpm 560 gpm
If you have a simplex single acting reciprocating
pump making 110 strokes/minute, with a 5"
diameter cylinder, a 10" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 3809 A this pump? 42 gpm 84 gpm
If you have a duplex single acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 13" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3810 B this pump? 425 gpm 163 gpm
If you have a duplex single acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3812 D this pump? 314 gpm 52 gpm
If you have a duplex double acting reciprocating
pump making 190 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
88% volumetric efficiency, what is the capacity of
11 3813 A this pump? 164 gpm 82 gpm
Turning the
adjustment screw
counterclockwise, as
viewed from the
bottom, results in an
Which of the following statements best describes increase in The sensor bulb
the operation of the refrigeration valve shown in evaporator superheat detects changes in
11 3814 A the illustration? setting. box temperature.
Which segment of the graph shown in the
11 3815 C illustration represents the latent heat of fusion? line 4 Line 3
If you have a duplex single acting reciprocating
pump making 250 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
89% volumetric efficiency, what is the capacity of
11 3816 A this pump? 34 gpm 57 gpm
The part labeled "C" of the illustrated bearing is
11 3817 D called the __________. thrust ring outer race
The lowest temperature at which fuel oil gives off
sufficient vapor to burn continuously when ignited autoignition
11 3818 D is defined as the __________. burning temperature temperature
If you have a duplex double acting reciprocating
pump making 120 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 3819 D this pump? 72 gpm 216 gpm
lowest temperature
at which the fuel oil lowest temperature
will give off enough at which the fuel oil
vapor to momentarily will give off enough
The flash point of bunker fuel is defined as the flash into flame when vapor to continue to
11 3820 A __________. ignited burn once ignited
A micrometer scale reading is indicated as 0.349
inches and is represented in the illustration by
11 3821 A __________. Figure C Figure A
If you have a simplex single acting reciprocating
pump making 180 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3822 A this pump? 134 gpm 537 gpm
Some 'hot gas' defrost systems reheat the increase the prevent chill shocking
refrigerant just prior to its returning to the circulation of liquid the compressor
11 3825 D compressor to __________. refrigerant suction valves
11 3831 D When using a chisel, you should __________. wear gloves hold the tool lightly
The reading on the micrometer scale shown in
11 3832 D figure "C" in the illustration is __________. 0.301 inch 0.310 inch
If you have a duplex single acting reciprocating
pump making 160 strokes/minute, with a 4"
diameter cylinder, a 5" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3833 A this pump? 41 gpm 52 gpm
The pressure in a low pressure refrigeration
system about to be opened for repair should be
11 3834 D __________. 10 to 12 psig 4 to 7 psig
When adding oil to a refrigeration system, the compressor all air is purged from
precautions must be taken to ensure that suction pressure is the pump and
11 3835 B __________. not too high charging fittings
If you have a duplex single acting reciprocating
pump making 250 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
79% volumetric efficiency, what is the capacity of
11 3836 B this pump? 132 gpm 75 gpm
When a refrigeration system is being charged refrigerant should be suction service valve
11 3893 A through the low side, the __________. added as a vapor must be back seated
To gain sensitivity, The flame of a halide
Which of the following statements is correct the largest possible torch will turn blue in
concerning the testing of an R-12 refrigeration flame should be used the presence of R-
11 3894 C system for leaks in an enclosed compartment? with the halide torch. 12.
temperature limiting
Coast Guard Regulations (46 CFR) require that a regulating valve to be
small electrically heated hot water supply boiler, set at not more than manual pressure
11 3895 C must be fitted with a/an __________. 220° Fahrenheit regulator
If you have a duplex double acting reciprocating
pump making 180 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
98% volumetric efficiency, what is the capacity of
11 3896 D this pump? 108 gpm 90 gpm
temperature at which
paraffin wax begins
temperature at which to crystallize out of
11 3907 C The flash point of a liquid is the __________. it burns freely the solution
The lowest temperature at which the vapors of a
flammable liquid will ignite and cause self-
sustained combustion in the presence of a spark autoignition vaporization
11 3908 D or flame is the __________. temperature temperature
Oils are usually graded by their service
11 3909 D classification and __________. fire point flash point
During operating temperature changes, the ability
of a lubricating oil to resist viscosity changes is viscosity index
11 3910 B indicated by a/an __________. API number number
If you have a simplex single acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
80% volumetric efficiency, what is the capacity of
11 3911 D this pump? 188 gpm 94 gpm
Copper piping has been used in refrigeration it is creep resistant at it offers greater heat
11 3914 B systems because __________. low temperatures transfer coefficient
Additives commonly found in turbine lubricating oil
11 3915 D include __________. antifoaming agents oxidation inhibitors
If you have a duplex double acting reciprocating
pump making 150 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 3916 B this pump? 70 gpm 140 gpm
work on a
intentionally vent refrigeration system
With regards to shipboard refrigeration systems, class I or II without permission of
after November 14, 1994 it is illegal to refrigerants to the the Officer in Charge
11 3950 A __________. atmosphere Marine Inspection
If you have a duplex single acting reciprocating
pump making 250 strokes/minute, with a 4"
diameter cylinder, a 6" stroke and operating with
70% volumetric efficiency, what is the capacity of
11 3951 C this pump? 86 gpm 29 gpm
Storage batteries to
provide all power for
the vessel and
Coast Guard Regulations require that vessels of operated under load All vessel internal
500 GT or less, what equipment must be tested for emergency control system
11 3952 D weekly? lighting. alarms.
When starting a reciprocating refrigeration
compressor that has been shutdown for a period
of time, you should manually throttle the
11 3954 C __________. sea water valve king valve
The type of gage most commonly used to
11 3955 C measure pressure is the __________. bimetallic type diaphragm type
If you have a duplex double acting reciprocating
pump making 180 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
80% volumetric efficiency, what is the capacity of
11 3956 B this pump? 94 gpm 188 gpm
eliminate moisture
from the refrigeration separate refrigerant
11 3957 C Purging is the process used to __________. system from oil
Gate valves should not be used for throttling as the pressure drop will air binding will
11 3958 D __________. be excessive develop
If you have a duplex single acting reciprocating
pump making 170 strokes/minute, with a 5"
diameter cylinder, a 4" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 3962 D this pump? 40 gpm 25 gpm
A purge connection installed on the refrigerant
side of a water cooled condenser is used to free tubes of charge the system
11 3963 C __________. accumulated scale with refrigerant
If you find the pressure of a R-12 refrigeration only recover the only recover the
11 4030 D system to be worked on is 0 psig, _________. vapor refrigerant liquid refrigerant
Deck beams on a MODU are generally spaced at
11 4033 C equal intervals and run __________. longitudinally vertically
Dirt should not be allowed to contaminate a bearings will leak oil dirt will cause
11 4048 D grease lubricant because the __________. excessively corrosion of bearing
The lubrication of a precision high speed bearing high detergent oil
depends upon a system that produces with pressure constant viscosity
11 4049 D __________. additives lubrication
When the rotating shaft frequency and the natural
vibrating frequency become synchronized at a
particular speed, that speed is known as the
11 4050 B __________. brekaway speed critical speed
passage for sealing
The function of the section labeled "C" in the liquid to enter the passage for gas to
11 4051 B device illustrated is to provide a/an __________. pump be discharged
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 4052 C this pump? 69 gpm 83 gpm
The compressor in figure 4, if permitted to operate damage the bearings damage the bearings
11 4055 B as illustrated will __________. of the compressor of the driving motor
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
91% volumetric efficiency, what is the capacity of
11 4058 B this pump? 4.5 gpm 9.0 gpm
Coast Guard Regulations (46 CFR) permit the
interval required for drawing certain tailshafts to Vessel Operator's
11 4060 C be extended by the __________. senior Port Engineer Senior ABS surveyor
When metal is tempered, it becomes
11 4061 C __________. harder less tough
When metal is tempered, it becomes
11 4062 C __________. harder less flexible
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 4"
diameter cylinder, a 5" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 4063 D this pump? 41 gpm 52 gpm
In addition to removing water from a refrigerant,
most dehydrators also effectively remove
11 4064 A entrapped __________. acid air
refer to a checklist
create a unique set that represents the
In order to assess each trainee in the of subjective skill process as
performance of a practical demonstration, the questions for each required on board the
11 4088 B assessor should __________. trainee vessel
If the discharge valves used in a refrigeration the reeds should be the reeds should be
11 4095 B compressor are leaking badly, __________. reground replaced
A thermal expansion valve installed in a the solenoid valve regulating the king
11 4104 C refrigeration system is controlled by __________. energizing coil valve
The stud and nut pictured just below "B" is used to prevent the shaft hold the impeller onto
11 4110 D __________. sleeve from sliding the shaft
If you have a duplex double acting reciprocating
pump making 150 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 4111 D this pump? 44 gpm 73 gpm
11 4112 A test test test
A temperature reading of 72 degrees on the
fahrenheit scale would correspond to what
11 4113 C temperature on the centigrade scale? 18 degrees 20 degrees
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 4115 B this pump? 132 gpm 526 gpm
Maximum efficiency
is achieved when the Operating the pump
pump is operating at at a capacity of 1600
Which of the following statements is true a capacity of GPM would require
concerning the pump characteristics shown in the approximately 900 approximately 60
11 4116 B illustration? GPM horsepower
Which of the filters listed will deplete the additives
11 4117 B in lubricating oil? Abundant filter Adsorbent filter
If you have a duplex single acting reciprocating
pump making 100 strokes/minute, with a 7"
diameter cylinder, a 13" stroke and operating with
90% volumetric efficiency, what is the capacity of
11 4118 D this pump? 672 gpm 97 gpm
Which of the filters listed will deplete the additives
11 4119 A in lubricating oil? Adsorbent filter Cloth bag extractor
If your vessel burns 3 tons of fuel per hour at 19
knots, how many tons per hour will it burn at 15
11 4120 D knots? 5.3 tons 2.4 tons
Which of the filters listed will deplete the additives Extended area
11 4121 C in lubricating oil? Fine copper screen membrane filter
If you have a duplex double acting reciprocating
pump making 120 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
92% volumetric efficiency, what is the capacity of
11 4122 A this pump? 108 gpm 54 gpm
Energy existing in a system as a result of the
relative velocities of the objects is defined as
11 4123 C __________. potential energy pressure energy
Mechanical energy in transition is referred to as
11 4125 C __________. enthalpy heat
Using the device shown in the illustration, which of Fitting #3 should be Fitting #2 should be
the following statements is true when adding a connected to the connected to the
11 4126 D charge to a refrigeration system. refrigerant cylinder. system low side.
restrict movement of
hydraulic fluid in one
direction, but allow
An orifice-check valve placed in a hydraulic regulate the fluid flow free movement in the
11 4157 B system is used to __________. in either direction other direction
From the illustration shown, what would be the
normal procedure to make adjustments to angle Rock the tool holder Remove the tool bit
11 4158 A "E"? on its base. and regrind.
The hub purge valve serves to relieve pressure in The propeller is The propeller is
the forward chamber of the servomotor cylinder in stroked beyond its stroked beyond its
11 4167 B a CPP system when what situation occurs? full ahead pitch limits. full astern limits.
prevent seawater
provide extra oil for from entering the
The function of the head tank on a CPP system is maintaining the hydraulic system
11 4168 B to _________. normal sump level when it is secured
The direction in which the control oil servo valve
opens and directs control oil to the oil distribution
(OD) box piston in a CPP system is determined by
11 4169 B the command _________. signal timing input signal polarity input
Flux is used when soldering, in order to decrease the melting decrease the surface
11 4179 B __________. point of the solder tension of the solder
The function of the device illustrated is to assist in sychronizing measure the speed
11 4246 B __________. generators of a rotating shaft
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 6"
diameter cylinder, a 4" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 4247 A this pump? 30 gpm 118 gpm
Modern trends show that full flow filters used in
multi-operation hydraulic systems would most on the reservoir on the relief valve
11 4248 A likely be located __________. return line discharge line
At which of the following intervals must the cargo Prior to each fuel At least once each
11 4264 C pump relief valves on tank vessels be tested? discharge operation. voyage.
What is the physical state of refrigerant as it
leaves a receiver in a typical refrigeration
11 4265 A system ? subcooled liquid superheated liquid
R-134A is normally the replacement for which
11 4266 A older type of refrigerant? R-12 R-22
the weight of the the maximum weight
The "Tare Weight" of a refrigerant storage cylinder cylinder with its of the refrigerant
11 4267 D refers to _______? current contents charge
If a block and tackle arrangement were rigged as
shown in figure "D" in the illustration, the amount
of force "P" required to hold the 383 pound load
stationary would be __________. (See illustration
11 4268 C GS-0110) 57 lbs. 77 lbs.
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 4"
diameter cylinder, a 9" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 4269 C this pump? 118 gpm 59 gpm
Which of the following substances is normally
11 4270 B classified as a low pressure refrigerant? R-12 R-123
What is the color coding for a storage container of
11 4271 D R-134A refrigerant? green grey
a self contained
safety goggles and breathing breathing
lined butyl gloves apparatus (scba)
would be required would be required
If there is a "large" release of refrigerant gas in a before entering the before entering the
11 4273 B confined area, _______. space space
The average
temperature of the
In a shipboard potable water system, which of the The hot water return hot water heater
following symptoms would indicate that the hot manifold would be would be above
11 4297 D water circulating pump had failed? warmer than normal. normal.
it is important to
remember that the
oxygen cylinder and never allow more
hose thread than 15 PSIG
When welding or burning with an oxy-acetylene connections are left pressure in the
11 4318 B torch, __________. handed acetylene hose
If you have a duplex double acting reciprocating
pump making 140 strokes/minute, with a 4"
diameter cylinder, a 7" stroke and operating with
85% volumetric efficiency, what is the capacity of
11 4319 B this pump? 23 gpm 91 gpm
If a bilge pump is able to develop some vacuum,
but is unable to sufficiently pump out the bilges, a clogged suction leaks in the suction
11 4320 D you would check for __________. strainer piping
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 4"
diameter cylinder, a 10" stroke and operating with
75% volumetric efficiency, what is the capacity of
11 4321 C this pump? 33 gpm 131 gpm
The difference between the setpoint and the
measured parameter in an automatic flow
11 4322 C controller is called: gain bias
The range of values around a setpoint of a
measured variable where "no action" occurs in an
11 4323 C automatic flow controller is called: deviation error
In addition to pressure, most refrigerant
compound gages are also provided with a scale saturated gas superheated gas
11 4324 A indicating __________. temperature temperature
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 5"
diameter cylinder, a 13" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 4325 D this pump? 267 gpm 134 gpm
In an automatic flow controller, the factor by which
the magnitude of the flow error signal has been
increased to drive the final valve controller is
11 4326 B referred to as: bias gain
In a proportional controller, the term "offset" refers control point and control point and
11 4327 A to the difference between the: setpoint proportional band
The return signal from a valve as sensed by an
automatic flow controller that is proportional to the
11 4328 C actual valve position is referred to as: gain bias
The difference between the set point in an
automatic controller and the steady-state value of
11 4329 A the measured parameter is called: offset gain
Which of the following changes in pump operating
parameters will lead to pump cavitation in a Steadily increasing
centrifugal pump that is operating in an open Steadily decreasing pump suction
11 4330 D system? pump speed pressure
If you have a duplex double acting reciprocating
pump making 110 strokes/minute, with a 3"
diameter cylinder, a 5" stroke and operating with
97% volumetric efficiency, what is the capacity of
11 4331 A this pump? 33gpm 27 gpm
As shown in the illustration, if electric current The evaporator The spool piece of
energizes the solenoid valve #24, which of the defrost cycle will modulating valve #5
11 4332 A following will occur? initiate. will shift to the left.
If you have a duplex double acting reciprocating
pump making 160 strokes/minute, with a 6"
diameter cylinder, a 5" stroke and operating with
96% volumetric efficiency, what is the capacity of
11 4333 B this pump? 47 gpm 188 gpm
The probe should be
moved rapidly over The torch is effective
Which of the following statements is correct the area of a in locating large
11 4334 C concerning a halide torch leak detector? suspected leak. leaks only.
If a reciprocating air compressor has a knock
occurring in frequency with its operating RPM, insufficient cylinder
11 4335 A the cause is probably __________. worn main bearings lubrication
If you have a simplex single acting reciprocating
pump making 130 strokes/minute, with a 4"
diameter cylinder, a 12" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 4336 A this pump? 39 gpm 154 gpm
In a direct expansion condensing unit type
refrigeration system, an externally equalized
thermal expansion valve will respond to
__________. I. A change in temperature of the
evaporator coil II. pressure surges at the
11 4338 C compressor suction I only II only
maintain radial
alignment between
One of the main functions of wearing rings, as the pump impeller absorb all impeller
11 4345 D used in a centrifugal pumps, is to __________. and casing shaft end thrust
The absolute pressure maintained in the shell of slightly more than the
the salt water feed heater on most flash slightly less than the supplied live steam
evaporators used on steam propelled vessels is absolute pressure of pressure at the
11 4351 A __________. the L.P. extraction reducing valve outlet
If you have a duplex double acting reciprocating
pump making 140 strokes/minute, with a 5"
diameter cylinder, a 7" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 4353 D this pump? 43 gpm 78 gpm
Which of the locations listed would be considered Between the Between the thermal
as the most common place to install a dryer in a compressor and the expansion valve and
11 4354 D refrigeration system? condenser. the evaporator.
On modern tankers with separate pumprooms,
which of the following is used to minimize cargo
11 4355 B pump shaft leakage? Slinger rings Mechanical seals
When there is no movement of the rams of an
electro-hydraulic steering gear system, the tilting
box of the axial piston hydraulic pump is operating at in the recirculation
11 4356 C __________. maximum torque mode
A "P" type trap and drain is used for sanitary the 'gray' water drain
system piping rather than an "S" type trap, hot water drains are system connection is
11 4357 C whenever __________. being removed located in the deck
In a typical refrigeration system, refrigerant
leaving the receiver will then flow to the
11 4359 B __________. evaporator coils liquid line strainer
The basic function of the servo control shown in establish minimum establish minimum
the illustration, as used in some hydraulic operating pressures operating flow rates
11 4373 D systems, is to __________. within the system within the system
After using a pipe cutter to cut a piece of pipe, the deburred with a pipe cleaned with a pipe
11 4382 A inside edge of the pipe should be __________. reamer cleaner
separate oil from the
One of the functions of the component labeled "E" act as a hydraulic compressed air
11 4383 B shown in the illustration is to __________. accumulator supply
Excessively tight drive belts installed between a
motor and a refrigeration compressor pulley may unnecessary motor
11 4384 D cause __________. overheated bearings loading
The thermal bulb for a thermal expansion valve
used in a refrigeration system is usually charged the same refrigerant
11 4385 B with __________. distilled water as the system
A room thermostat
activates an electric
Which of the following methods is normally used heater at each Varying the number
to control the individual room temperature with an individual chilled air of passes the air
air conditioning system using a chilled water outlet when makes across the
11 4399 D circulation system? necessary. cooling coils.
Transfer of heat is
accomplished by
The conductivity of passing through solid
the heat source material causing a
Which of the statements best describes the controls the final change in
11 4400 B process of heat transfer by conduction? temperature. temperature.
remove the
handwheel, then
replace the entire remove part #4 and
valve bonnet and #5, then replace the
The illustrated valve "A" needs to be repaired due stem as a unit as item #6 and
to a leak across the valve disk. To repair the provided by the reassemble in the
11 4420 C valve you should __________. manufacturer reverse order
The line labeled "G", as shown in the illustration, processed bilge
11 4421 A would be identified as the ______. separated oil outlet water outlet
allow an alternate
main pump to start in prevent the idle main
the fully loaded pump from being
Hydraulically, servo-operated, automatic, change condition thus hydraulically motored
over valves, utilized in a two ram hydraulic developing by cross pressure
11 4425 B steering gear, serve to ________. immediate full torque. flow.
increasing the
The presence of gas in the liquid line of a distance between the
refrigeration system is undesirable and can be evaporator and using a larger
11 4426 C eliminated by __________. condenser expansion valve
Sludge may form in the lubricating oil crankcase low freon contamination by
of a reciprocating air conditioning compressor as temperature in the dust, scale, or
11 4427 B a result of __________. suction line moisture
If you have a duplex single acting reciprocating
pump making 130 strokes/minute, with a 3"
diameter cylinder, a 10" stroke and operating with
93% volumetric efficiency, what is the capacity of
11 4428 A this pump? 37 gpm 123 gpm
The sudden reduction of pressure occurring within sudden evaporation sudden evaporation
the crankcase of a refrigeration compressor of wax crystals in the of entrapped air in
11 4430 C during starting causes the __________. lubricant the lubricant
When a refrigeration compressor has developed a increase the amount decrease the amount
high head pressure as a result of a refrigerant of cooling water to of cooling water to
11 4440 D overcharge, you should __________. the condenser the condenser
Which of the fluids listed is normally used to
condense the primary refrigerant in a shipboard Seawater or Fresh
11 4441 B central air conditioning system? Engine jacket water water.
To add refrigerant to the high side of an air
conditioning system, you should close the king
valve and introduce the refrigerant through the discharge service suction service valve
11 4442 C __________. valve as a vapor as a liquid
In a small appliance using HFC-134a you would
expect to see the greatest temperature drop
11 4443 D across the __________. evaporator receiver
When air contains some moisture, but is not between the wet and
saturated, the dew point temperature is dry bulb equal to the total
11 4444 D __________. temperatures heat of air
The lathe tool shown as figure "L" in the
illustration is commonly known as a/an external threading
11 4445 C __________. boring tool tool
Heat transfer always Heat transfer always
flows from hot flows from cold
Regarding heat transfer principles, which of the regions to cold regions to hot
11 4446 A following is true? regions. regions.
If you have a simplex single acting reciprocating
pump making 150 strokes/minute, with a 6"
diameter cylinder, a 14" stroke and operating with
95% volumetric efficiency, what is the capacity of
11 4447 B this pump? 61 gpm 122 gpm
it offers a greater
heat transfer
Copper piping has been used in refrigeration it is creep resistant at coefficient than iron
11 4448 B systems because __________. low temperatures pipe
If you have a duplex single acting reciprocating
pump making 140 strokes/minute, with a 3"
diameter cylinder, a 12" stroke and operating with
94% volumetric efficiency, what is the capacity of
11 4449 C this pump? 193 gpm 24 gpm
What is the reading of the vernier caliper scale
11 4450 A shown in figure "E" in the illustration? 4.112 inch 4.125 inch
If the people in an air conditioned room complain
of being too cool, the trouble might be that the preheater has failed
11 4451 D __________. to cutout air velocity is too low
What is the reading of the vernier caliper scale
11 4452 A shown in figure "D" in the illustration? 2.8350 inch 3.3750 inch
Gate valves should not be used for throttling as the pressure drop will air binding will
11 4453 D __________. be excessive develop
When pumping down an air conditioning system
to test the low pressure cutout switch, you should secure the
11 4454 C __________. stop the compressor condenser
prevent seawater
from passing out the assist the pump in
Some centrifugal pumps have water lines stuffing box when a maintaining a
connected to the stuffing box glands to high suction head is vacuum and cool the
11 4455 B __________. present packing
The major difference to consider when selecting a flow rate at which efficiency to seal and
P-type or S-type lavatory drain trap would be the water must be prevent sewer gas
11 4480 C __________. removed backflow
If you have a simplex single acting reciprocating
pump making 180 strokes/minute, with a 5"
diameter cylinder, a 6" stroke and operating with
87% volumetric efficiency, what is the capacity of
11 4481 A this pump? 40 gpm 160 gpm
The reading on the micrometer scale shown in
11 4482 C figure "2" in the illustration is __________. 0.200 inch 0.220 inch
regulate refrigerant
flow into the
evaporator by
provide the function reacting directly to
The valve shown in the illustration is used to of compressor the evaporator
11 4500 C __________. unloading pressure
The hydraulic graphic symbol illustrated as Fig. C bi-directional rotating unidirectional rotating
11 4501 C is used to depict a/an __________. motor motor
In a multi-effect submerged tube distilling plant, scale formation with priming with
rapid fluctuations of the last effect absolute increased heat increased salinity of
11 4505 B pressure will tend to cause __________. transfer distillate
The steam coils in a high pressure contaminated
evaporator used in a steam plant should be a wire brush and
11 4507 A descaled with __________. wooden mallet a needle gun
While inspecting the steering system at sea, you air bubbles in the any leaks in the
11 4512 B should check for __________. sight glass system
The valve normally The valve is set to
Which of the following statements describes the requires a manual trip if the sea water
operation of a three-way solenoid trip/dump valve latch reset after feed temperature
11 4513 A on a two stage flash-type evaporator? triping. exceeds 180°F.
The safety device which normally stops the
refrigeration compressor before the relief valve low pressure cutout back pressure cutout
11 4514 C starts to open is the __________. switch switch
released by spring
When the hydraulic control lever for a deck winch engaged by spring action and
is placed in the neutral or off position, the spring action and only hydraulically locks
set brake on the fluid motor drive shaft is released by hydraulic the winch when the
11 4524 A __________. pressure drum ceases rotating
Operation of a hydraulic pump in a cavitating the hydraulic fluid to the fluid motor to
11 4531 A condition can cause __________. become overheated become overloaded
A lube oil purifier
What equipment is required when processing A 100 PPM oily water operating as a
11 4532 C bilge slops for overboard discharge? separator. separator.
Determine the values of "A", "B", and "C" in the A = 71.2°F, B = A = 90.0°F, B =
table accompanying the chart shown in the 62.5°F, C = 35.0 62.5°F, C = 27.0
11 4533 A illustration. BTU/lb BTU/lb
HCFC-22 has been recovered from a refrigeration recycled into a reclaimed as a low
system during replacement of the condenser. system that had used pressure system
11 4534 C This refrigerant can be __________. HCFC-11 refrigerant
A compressor operating with an accumulation of
dust and grease on the surfaces of an intercooler
would result in __________. I. the motor to run
warmer than usual II. the second stage would
11 4535 C operate at a higher temperature I only II only
Some of the hazards associated with air-operated inspect the hoses for
power tools may be avoided if the operator would cracks and other remove jewelry and
11 4536 D __________. defects loose clothing
The definition of superheat refers to the amount of
heat a substance contains and applies to
11 4537 A __________. I. vapors II. Solids I only II only
According to 46 CFR, the tailshafts of a twin
screw ocean going vessel must be examined and
inspected in the presence of a marine inspector each time the vessel at least twice every
11 4538 D ______. is drydocked five years
All portable electric tools should have a ground electric shock if the burning out the motor
11 4556 A connection to prevent __________. tool is shorted from an overload
To prevent any
Application may be delay, a temporary
made for inspection Certificate of
and issuance of a Inspection may be
new Certificate of issued pending
Inspection at any delivery of the
According to 46 CFR Part 91, which of the time during the regular Certificate of
following statements concerning a vessel's Coast period of validity of Inspection upon
Guard Certificate of Inspection and associated the current completion of the
11 4569 D inspections is correct? Certificate. inspection.
According to 46 CFR Part 61, what is the
maximum allowable permitted wear on a stern
tube bushing for a vessel that has its propelling
machinery located amidships, with a water
lubricated stern tube bearing carrying a 12 inch
11 4570 C diameter shaft ? 1/4 inch 5/16 inch
The follow-up
mechanism will be The follow-up
In a typical hydraulic steering gear system, as the compensating with mechanism will be
designated rudder angle is approaching the helm an increasing signal inactive as long as
command angle, what will be the reaction of the to the hydraulic pump rudder angle error
11 4575 D steering gear follow-up mechanism? tilt box controls. exists.
A vessel has a mean draft of 28 feet 08 inches
before taking bunkers. What will be the final aft
draft after taking on nine hundred tons of fuel oil, if
the TPI immersion is 50 and the final forward draft
11 4576 C is 30 feet 00 inches? 30 feet 00 inches 30 feet 02 inches
Coast Guard Regulations (46 CFR Part 56) cycling all connected
require all power-operated valves, other than being cross valves from the initial
those opened against spring force, to have an connected to an valve position to the
energy storage system. That energy storage alternate power opposite position and
11 4580 B system shall be capable of __________. supply return
The power necessary to close the diaphragm
control valve, as used in a pneumatic control valve positioning controlled fluid
11 4581 C system, is supplied by the __________. plunger pressure
total number of
The exploded drawing shown in the illustration is hidden parts in the component parts
11 4587 B intended to show the __________. assemby aligned for assembly
When cutting with a handheld hacksaw, you
should apply downward pressure on the hacksaw on the forward stroke only on the backward
11 4588 D frame ______. and backward stroke stroke
provide an area to
provide an area separate solid
One function provided by a hydraulic accumulator where air can contaminants from
11 4589 D is to __________. separate from the oil the oil
In the illustration shown, what is the distance
11 4590 D indicated by dimension "A"? 0.2750 inches 0.3000 inches
In the illustration shown, what is the distance
11 4591 C indicated by dimension "B"? 0.6750 inches 0.7000 inches
Which chemical, when released into the
atmosphere, has been found to eventually reach
the stratosphere and react unfavorably with the
11 4592 B earths ozone layer? fluorine chlorine
Which of the following conditions is most likely to The hydro-pneumatic Loss of air in the
cause water hammer in the potable water system tank being half full of hydro-pneumatic
11 4602 B shown in the illustration? water tank.
After installing a new hydraulic pump in a system, The relief valves in The filters and
what special attention should be given to the the system should be strainers should be
11 4615 B hydraulic system? readjusted. checked frequently.
Which units of measurement are commonly used Inches of mercury for Feet of water for
to express pump suction head values when positive head and positive head and
calculating pump capacities and hydraulic feet of water for inches of mercury for
11 4616 D horsepower? negative head negative head
A typical shipboard domestic multi-box To open or close the To open the back-
refrigeration system operates with one solenoid valve when pressure regulating
compressor and condenser. What is the purpose the box temperature valve when
of the sensing line connected to the thermal bulb increases or evaporator coil
11 4642 D at the evaporator coil outlet? decreases. pressure increases.
the numerical
The size of flexible hose used in a hydraulic the outside diameter designation found on
11 4654 B system is indicated by __________. of the hose the 'skin' of the hose
If the numerical designation indicated on the
outside of a hydraulic hose is BXP-10, the "dash
size" 10 indicates that the inside diameter of the
11 4655 A hose is _______. 5/8 inch 3/4 inch
line up corresponding
An aligning punch is commonly used to holes in adjacent
11 4660 A __________. symetrical parts loosen jammed bolts
In a centrifugal pump, the purpose of the sealing
line is to provide liquid from the discharge side of
11 4661 D the pump directly to the __________. slinger ring wearing ring
When welding or burning with an oxygen-
acetylene torch, the acetylene hose working
11 4662 C pressure must not exceed __________. 2 psi 5 psi
A constant pressure range is maintained in the
potable water system of many vessels by using constant speed variable speed
11 4663 C __________. supply pumps supply pumps
insure that the
purge the balance balance chamber is
To ensure an accurate tank level pneumercator chamber to remove completely full of
11 4664 A reading, you should __________. any liquid liquid
The hydro-pneumatic
expansion tank is
According to the illustration, which of the following operating with an The hydro-pneumatic
conditions would most likely cause Pump "A" to insufficient air tank is operating with
11 4669 A short cycle? charge. a low water level.
establish if the
One important objective of a practical skill institute busy work trainee can perform
demonstration for mariner certification is to for both the trainee certain tasks at a
11 4676 D __________. and assessor later time
With respect to machine shop "taps and dies", a starting the threads reversing the threads
11 4711 C plug tap is correctly used for __________. on a circular rod in a hole
When adding packing to a pump shaft seal, you excessive friction in excessive wear of
11 4712 D must be careful to prevent __________. the joint the pump shaft
Which component in the illustrated hydraulic
crane circuit acts to prevent the wire rope drum
11 4713 C from accidentally paying out? #1 and #3 #2 and #3
In the hydraulic crane circuit illustrated, which activate directional activate directional
would be the correct hydraulic configuration valve 9 and shift valve 9 and shift
11 4720 B required to raise the boom? spool valve to area 3 spool valve to area 1
Provide additional
Provide additional control when
In the hydraulic crane circuit illustrated, what is control when swiveling the
11 4721 A the function of the component labeled #18? lowering the boom. platform.
the second effect
The efficiency and output capacity of a low shell pressure is chemical feed is
pressure distilling plant will be greatly reduced if lower than the first continuously
11 4722 D __________. effect introduced
The valve shown in the illustration is commonly hand expansion back pressure
11 4723 B identified as a ______. valve regulating valve
A simplex pump making 60 pumping strokes per
minute has a 10 inch stroke and a 6 inch diameter
water cylinder, which is 75% full for each stroke.
How many gallons of water are discharged per
11 4724 D hour? 4208 GPH 6610 GPH
Operating a water service centrifugal pump with
an excessive amount of wearing ring clearance excessive pump
11 4725 C would result in _______. noisy pump operation vibration
Which of the listed materials have been used to
manufacture piping available in standard weight,
extra strong, and double extra strong wall
11 4726 C thickness? Plastic Copper
Which of the following statements represents an Reduced steam
advantage of a triple-effect submerged tube requirements per
evaporator compared to a single-effect Less heat transfer pound of distillate
11 4727 B submerged tube evaporator? surface area produced
the capacity will
remain the same
If a flash-type evaporator is operating in extremely the evap feed heater regardless of the
cold seawater temperatures, the engineer may will require less evaporator shell
11 4728 C expect that _______. steam temperature
Which of the following statements represents an The bearing requires The bearing is
operating characteristic of neoprene or rubber occasional normally lubricated
11 4734 B stern tube bearings? adjustments. by seawater.
Where would you find the greatest amount of
refrigerant superheat in an operating refrigeration The evaporator
11 4735 D system? outlet. The receiver inlet.
The capacity of a fuel oil transfer pump is 100
gpm. If a fuel oil setting tank measures 6 feet by
6 feet by 12 feet high, how long must the pump
run to fill the tank to 11 feet, if the tank presently
11 4736 A holds 2 feet of fuel? 24 minutes 28 minutes
What is the main reason that live auxiliary steam To reduce the rate of
is normally attemporated before entering the feed scale formation on To increase the brine
11 4739 A heater of a flash evaporator? heating surfaces. overboard density.
Figure "B" in the illustration is improperly installed. at the right hand end, at the left hand end,
A restriction will develop in this hose regardless of the regardless of the
11 4911 D __________. direction of flow direction of flow
16-Jul-07
ANS C ANS D ILLUS
Certificate of
Inspection construction portfolio
non-structural continuous
60° thread cutting
screw thread pitch tools
3 4 GS-0132
Bimetallic Impulse
right hand turning
tool universal turning tool GS-0090
specific heat of
refrigerating effect vaporization
Certificate of
construction portfolio Inspection
3 4 GS-0003
flow characteristics of
tendency of hot water a liquid as it passes
to flash into steam through an orifice
vaporization evaporation
C D GS-0121
Acts as an
Purifies the air. accumulator.
to initially unload the
pump by having its in order to overcome
head pressure equal the potential energy
to discharge of water in the
pressure discharge line
Partial restriction in
Worn wearing rings. the discharge valve.
60 80
Longitudinal Vertical
cooling and
dehumidifying adiabatic cooling
the autogenous
ignition point All of the above.
location of
emergency repair type and strength of
equipment materials used
Isolate the discharge Dampen the
side from the suction turbulent discharge
side. flow.
overflowing recycling
positive displacement
pump centrifugal pump GS-0125
through a standard
orifice at a specified at a rate of 60cc per
temperature second
the ASTM or ABS
specification the
material manufacturer or
approximates origin of the material
transversely intermittently
rapid depletion of this gas become
acetylene is extremely unstable
hazardous under this condition
Q R GS-0090
recommendations for
the next test all of the above
frames beams
dampening humidification
only casualties which
occur while every event occurring
underway on board
stringers plates
flaring swaging
harder tougher
obstructed suctions
worn pintle bearings passage
Power is transmitted
There is no fluid flow. hydraulically.
a higher outlet
pressure with a lower
fluid outlet
temperature no change GS-0045
partial saturation
wet bulb 'depression' temperature
amount in inches of
force necessary to mercury the total
overcome frictional suction head is below
losses in the pump atmospheric
and piping pressure
24 inches 15 inches
stiffener stanchion
directional transverse
shell foundation bolts baffles
greater than the
pressure in the highest at the oil
lubricating system groove location
more corrosion
resistant a lower grade steel
7 or 9 9 or 11
C D GS-0073
condensed convected
a layer of oxidation
formed when the
a corrosion-resistant metal of the shaft is
paint exposed to seawater
They can be
removed when it is
necessary to lighten
the weight of the They increase the
pump. strength of the shaft.
the underside of
diaphragm "E" and the top of piston "H"
the inlet and the outlet GS-0044
resistant to
permanent readily saponified
emulsification with water
condensing evaporating
Electric element Forced hot air
heater heating GS-0150
Rotary pumps
eliminate discharge
slippage of the
Rotary pumps pumped liquid, while
occupy only one-half this does not hold
the space of true for a
reciprocating pumps. reciprocating pump.
C D GS-0129
Decreased
clearances Decreased slippage
maintain a
pressurized fluid film
between moving remove entrained
surfaces water
overspeeding the
spindle overheating the drill
To eliminate leakage
via the propeller shaft To provide a ready
when the shaft is not means for the entry
rotating. of cooling water.
To protect the
operator performing Each of the above is
the maintenance. correct.
The name of the
person performing
the opening and The fact that the hull
closing of such indicators functioned
appliances. or not.
The packing is
The stuffing box adjusted for greater
gland is tightened. cooling or replaced.
differential expansion
pressure shock rates
receiver evaporator
improve the displace lubricating
lubricating oil oil required in areas
viscosity of friction
condensation sublimation
sublimation condensation
2.0/32nds 3.0/32nds
ease at which the
wearing rings may be
lack of moving parts changed
shaft "K" has
developed a fault in that pump "G" can
the mechanical not develop
linkage adequate discharge GS-0123
Replaceable impeller
and casing wearing
Removable end plate rings
seal ring is
improperly located impeller is flooded
corrosion resisting
mild steel steel
reversed pump
a bent shaft coupling
malleability fusibility
delay the
compression process
until the motor is up check pump
to speed alignment
Distillate is the
Brine is the result of product resulting
condensed sea water from the evaporation
vapor. of fresh water vapor.
gross pump
worn wearing rings misalignment
plastic steel
anemometer sphygmomanometer
apply pressure
apply even force to evenly to both the
the inner race inner and outer races
Replace the soft
packing with packing
turns that are Continue to add
covered with lead more turns of
wrap. packing.
withstands heavy
vibration under heavy resists hardening
system loads under stress
150°F 175°F
cause a backup
power supply to automatically reclose
energize within 10 seconds
inner race retainer plate
misalignment of the
an open snifter valve crosshead guide
inside threads on
a left-hand twist both ends
a special petroleum
carbon tetrachloride solvent
Propeller Turbine
trichlorodifluorometh
ane sulphur dioxide
Compressor
discharge Compressor suction
temperature. pressure.
High-pressure Vertical
net positive suction
head suction head
biasing controlling
operating cock is
pressure in the placed in the 'vent'
system is allowed to position when the
equalize system is not in use
tees closures
extreme pressure
additive PH alkaline additive
C D GS-0129
coupling tee
C D GS-0121
back pressure
solenoid bypass regulating valve
Viscosity will
decrease as Viscosity is not
temperature dependent on
decreases. temperature.
are reduced in
temperature to just become extremely
above the pour point agitated or aerated
ceilings stanchions
48 months 60 months
Three-fourths of a
turn One turn
18 20
Class C Class D
second-stage flash
atmosphere chamber
90 100
packing box and gland seal and
packing gland is packing gland is
critical critical
E F GS-0086
General service
pump All of the above GS-0042
plus .000 inch to
plus .003 inch minus .003 inch GS-0016
butt seam
Decreased wear
rates of components Only chemically
is an advantage of its active filters may be
use. used.
Society of Naval
Architects and Enviromental
Marine Engineers Protection Agency
brine air
lap butt
separator strainer
charge of air, at 20
psi (137.9 kPa)
above system charge of air, at
pressure with the system pressure,
hydro-pneumatic when the hydro-
tank one quarter full pneumatic tank is
of water half full of water
Component "E" is
Component "F" will modulated
force "E" to be driven proportionally in
to the full open response to the
position. required output. GS-0120
bulking chlorinating
stanchions brackets
reduce liquid
separate cargoes in movement and
a common tank surging within a tank
Condensate flow is
continuously
controlled by the
permanently The valve is opened
maintained operating by the sinking
level of the bucket. bucket. GS-0048
blade tooth set
adjusted for
maximum cutting teeth angled toward
width the saw handle
C D GS-0142
Canister Bypass
lapping-in refacing
G H GS-0120
C D GS-0121
D E GS-0120
increase in volume reduce in volume by
by 1% for every 1/2% for every 1,000
1,000 psi increment psi increment
pillars brackets
24 32
thermal bulb is in a
cold air stream all of the above
longitudinals knees
Certificate of
Master's crew list Inspection
a failed heat
insufficient refrigerant interchanger
girders breasthooks
Obtaining a sample
of all fuel oil received
on board to be used
as fuel along with
ascertaining all
particulars such as
vendor, producer,
flash point, etc. All of the above.
The casing is of a
double volute design. All of the above. GS-0143
splash-type
lubrication provided gravity feed provided
in the compressor by component "A" GS-0119
The pump coupling is
damaged and pump Any one of the above
is unable to turn at will cause the
its required speed. actuator to not move.
Roller Ball
allow the
accumulator to
completely fill with
gas charge at
atmospheric
increase the pressure, shut off the
pneumatic pressure air chamber, and add
until the hydraulic hydraulic fluid until
system reaches its proper pressure is
design pressure reached
excessive refrigerant
suction pressure too returning to the
low compressor
reciprocating pump
with piston valve
centrifugal pump gear GS-0012
decrease pump decrease reaction
cavitation ring clearance
M R GS-0119
machine screw
thread fillet weld GS-0020
separate large
quantities of oil-water
compress air emulsions GS-0119
consistently faster
response or
movement of the over speeding of the
actuator pump
hydrostatically tested
to 100% of maximum
working pressure all of the above
empty space
separating
compartments to
prevent the contents
of one compartment
tank for storing from entering another
chemicals in case of leakage
jam in the hole and
cut a continuous chip break
front of the hacksaw top of the hacksaw
frame frame
be undertaken only
when all cargo tanks
are empty, gas free,
and made accessible
for internal
examination all of the above
1, 3, 5, 6, 8 and 10
open; 2, 4, 7 and 9 1, 2, 5 and 6 open;
closed. 4, 7, 8 and 9 closed. GS-0139
4 years 5 years
plugged evacuated
III IV GS-0100
15 fathoms 45 fathoms
step-designed diagonal
open close
Barrel Valve-in-head
The designed
rotating speed of the A leaking head
compressor. gasket.
II and III III and IV GS-0100
C D GS-0065
Variable spring
tension caused by
the changing Frost on the liquid
temperature. line.
Diameter, length, and
number of threads Diameter, head size,
per inch and shoulder length
a pressure gauge or
manometer shall be
installed on the the glands are to be
bulkhead to ensure kept under
the gastight seal is continuous suction
maintained with power ventilation
expansion valve suction valves were
strainers were fouled leaking slightly
wildcat capstan
Reed Sliding
scale formation
capacity increases decreases
rough rounded
compressing the
an asbestos gasket packing rings GS-0012
An improperly
A dirty inlet filter adjusted discharge
element valve
Still function
normally, but the
still function normally safety interlock will
at start-up stop the drive motor
Internal combustion
Watertight door engine hydraulic
system starter system
aftermost bilge-wells
connected to that
valve will siphon their
contents to the
forward bilge-wells all of the above
condenser is getting
insufficient cooling system is low on
water flow refrigerant
The ignition
temperature is They are not
always higher. necessarily related.
provide a supply
equalize pressure conduit of actuating
above and below the steam for the power
pilot valve piston GS-0044
comparing with a
hand tape using litmus paste
badly leaking
discharge valves worn piston rings
combustion
ignition temperature temperature
continuously throttle
steam which results receive high pressure
in wire drawing and air from the pilot
erosion of the valve valve
C D GS-0122
General service
pump All of the above GS-0042
To close the valve, it The butterfly valve
is only necessary to should never be used
turn the handle a in a freshwater
quarter of a turn. system.
C D GS-0063
eccentric portion at
eccentric portion right angles to the
above the pump pump suction
suction centerline centerline GS-0089
separated from
accommodations
spaces by non-
not considered as continuous
essential bulkheads
Main circulating/bilge
injection valve All of the above
E F GS-0101
reduce vapor
pressure of the water
entering the pump slope the suction line
suction upward at the pump GS-0089
Centrifugal bilge
Auxiliary fire pump pump
125.00 lbs. 250.00 lbs. GS-0110
compound
diaphragm compensating spring
taper, plug, and starting, through, and
bottom finishing
sediment water
There should be
some slack in the
hose. All of the above.
abnormally cold
a clear sight glass reefer boxes
At each biennial
At least once a year. inspection.
Volute Eye
45°C 50°C
It is the temperature
at which a It is the temperature
substance, when at which the released
ignited, will continue vapors will fall within
to burn. the explosive range.
limit hydraulic end
thrust initiate flow
16.00 tons 16.37 tons
to the impulse
to the impeller transmitter GS-0117
tap chaser
ensure positive
redirect hydraulic contact between the
fluid flow when Rapson slide and the
changing over pumps rudder post
Maximum torque,
when rotated in the
'pay out' direction Maximum speed in
would be obtained either direction of
with the tilting box rotation would be
just prior to neutral achieved just beyond
stroke, while 'hauling of neutral stroke,
in' would be the making reversal of
opposite. direction difficult.
22.10% 26.20%
tapered straight
Only a double
Any bastard cut file bastard cut file
oxidation of the lube reducing the floc or
oil from overheating cloud point of the oil
Reduction gears
would be required if a A tilting box hydraulic
hydraulic motor were motor could never
designed with a tilting produce more than
box. one horsepower.
10 psig 15 psig
vaporization in the heat exchange in
first-stage flash each stage distiller
chamber condenser
Linear actuator
without nylon insert Relief valve spool
no longer continue to
speed up by 5% until internally convert the
the discharge valve resultant energy
is reopened imparted to the pump
Nothing could be
The diameter of the done to convert this
rotor would have to device to a hydraulic
be increased. motor. GS-0074
3/4 HP 1.0 HP
creates a vacuum to
move a liquid in all is to develop a
installations pressure differential
-6.65% -11.04%
minimize the
temperature drop of
increase the the liquid as it passes
refrigerating effect by through the solenoid
increasing the valve to the outlet
amount of flash gas side
condensing compression
temperature temperature
Allen Torx
H E RA-0012
shank web
rotating vane
movable orifice plate transmitting nutating
venturi tube and high motion to a counter
pressure tap mechanism
A rapidly moving
stream of fluid A propeller drawing a
passing through a fluid through a
nozzle. venturi nozzle.
buoyancy of an
indicator in water
mass of substance with the buoyancy of
measured with the the same indicator in
density of the same the liquid being
substance measured
frame thimble
disengage the feed stop the lathe
reverse lever rotation
Apply an adhesive
Apply an adhesive to between part "F" and
part "G". the shaft. GS-0071
10 seconds for
ordered rudder
position changes of
2.5 degrees all of the above
C D GS-0073
C D GS-0022
Increase the
Increase the contact thickness of the
surface area of part cover gasket at point
"E". "H". GS-0071
#60 #80
Threading internal Boring an angled
threads. hole.
H G RA-0012
secure the
evaporator until the
feedwater raise the tripping
temperature can be point at the salinity
raised to 165°F or indicating panel for
more the three-way valve
E G GS-0071
U.S.C.G. Officer in
Charge, Marine
Inspection at the next
port vessel underwriters
increase the
avoid flooding the evaporator distilling
evaporator shell rate
pressure difference
expansion valve across the expansion
capacity to increase valve to increase
Z XX
C D GS-0046
A separate auxiliary
means of steering is
not required where
the main gear is of
the dual power
hydraulic type,
having two
independent pumps
and connections. All of the above.
water in the
unloader malfunction lubricating oil
Difference in brine
density between first Lower pressure in
and second stages first-stage
I J GS-0040
taper flute
As high side
pressure increases The increase in high
part "A", "B", and "C" side pressure will
will work together to gradually increase
reestablish the the tilting box angle
original tilting box of the variable
angle. displacement pump. GS-0040
protected by a circuit
breaker and a
thermal overload served by a single
device two conductor cable
Drier Receiver
adjusting spring is
compressed further,
diaphragm ruptures, outlet pressure will
the valve will close decrease GS-0054
dense flooded
9 knots 12 knots
closely maintained
design clearances in helical gear pumps
this pump is not are designed with
necessary extreme tooth angles
tubes of the air tubes of the distiller
ejector condenser condenser
gasoline naphtha
accumulator evaporator
self-closing gate
globe valve valve
throughput of the
capacity of the brine overboard
distillate pump pump
Rotary Gear
maintaining distillate
flow between the first
the absolute and second stage in
pressure developed order to avoid dry
in the salt water feed seal operation of the
heater shell loop
of no consequence
as the lube oil is not
used in the operation
the highest of the unloader RA-0013
Counterbalance
valve Pressure-relief valve
operate the
renew the entire oil machinery at
supply reduced power
insurance
U.S. Coast Guard underwriter
Duplex differential Duplex compound
pressure type type GS-0114
the pipe will be
completely blocked condensate
by even the slightest accumulates rapidly
amount of when flanges are not
misalignment properly aligned
short workpiece tubular workpiece
being machined to an being parted
internal taper between centers
in the expansion
valve in the receiver
condensate
separator drain pump
825°F 925°F
Evaporator Compressor
temperature density
condense all the
cool the incoming distillate in the
first-effect evaporator second-effect tube
feed nest
Spring-centered
Three-position valve valve
90° 118°
adiabatic effervescent
conditioning conditioning
Hot concentrated
brine tends to clog Hot brine tends to
the sealing lines and clog the brine pump
gland seal rings. suction line strainer.
level of a fluid in a
stack temperature tank
made of nylon or
other nonmetallic
gas tight material
a designed bursting
pressure of at least
an inner tube four times the
constructed of maximum working
seamless reinforced pressure of the
polyester braid system
Superheated
temperature Degree of superheat
tailstock headstock
boiling pressure
equal to that of a boiling point will not
pure refrigerant at a be affected by
given pressure entrained oil
divide by 12 multiply by 12
emulsification of the
thickener additive gelling of the base oil
maintain hydraulic
differential in the
pump impeller keep the shaft glands
passages cool
Elevation of heat
Lubrication of moving exchanger overboard
parts. outlet temperatures.
5 years 8 years
The self-priming
feature of the
centrifugal pump The discharge
enables it to draw its capacity varies
own suction as it directly with the
starts. speed of the impeller.
A hydrostatic proof
test at design
pressure, conducted
by the ship's force,
in which the safety
valves were gagged
to test a tube
plugging repair. All of the above.
temperature flow
The total quantity of
energy in the
universe is always
the same. None of the above.
Pneumatic Electrical
0.374 0.4375
can be quickly
can be removed by removed by simply
passing hot vapors shutting off fluid flow
through the coils to the coils
absorb shocks
act as an oil and occurring in the
water separator system
screw thread
screw pitch gage micrometer
disengaging of the
manual stop only splined dog clutch GS-0027
wide temperature
fluctuations rate action only
a shortage of
air in the system refrigerant
it must be held firmly
the hammer head by the head to strike
may be chipped it
used to throttle or
used for steam regulate the flow of
service only liquid
change speed
according to overload reduce compressed
demands air charge density
excessive opening of
excess refrigerant the expansion valve
proportional band
adjustment of the form of the controlled
controller medium
be opened as much
be opened by 1/2 of as needed,
the total number of regardless of how
turns available from little the gate has
full closed to full been moved from its
open seat
governor valve
cushioning valve spindle
water contamination
causes erratic the volumetric
operation of capacity of the first
pneumatic stage is reduced if
components water remains
short cycling of the
high discharge compressor on the
pressure water failure switch
three normally three normally closed
opened valves and valves and one
one normally closed normally opened
valve valve GS-0042
add extra weight to prevent tip oxidation
the tip when heated
horsepower foot-pound
33% 0% RA-0013
popping or sputtering
noises all the above
100% 500%
require to be marked
on both sides in
clearly legible letters
at least 25
millimeters ( 1 inch)
high none of the above
3 hp 4 hp
loss of refrigeration
effect in the space high suction pressure
being cooled at the condenser RA-0010
the proportional
the proportional action and the reset
action assists the action are completely
reset action during independent of one
decreasing error another in the
transients controller operation
limit the flow of
steam leaving a
heater until it has
given up its latent eliminate steam-pipe
heat of fusion water hammer
act as a pressure
sensing line from the provide a remote
compressor lube control pneumatic
system to unload all signal for changing
cylinders if a lube oil the control point
failure occurred operation setting RA-0013
install new docking
plugs in all inspect the hull for
cofferdams hogging or sagging
heat velocity
D G GS-0045
noisy compressor
operation low head pressure
Foot-pounds Calories
two position
differential gap
derivative control control
counter clockwise to
increase compressor clockwise to reduce
capacity and thereby compressor capacity
reduce suction and thereby raise
pressure suction pressure RA-0013
noisy compressor
operation upon refrigerant slugs in
starting the receiver
have a cross
have an independent connection to the
priming pump ballast system
The motor
overcurrent
protective device Pounding noises can
continually shuts the be heard at the pump
pump down. suction chest.
saponifying an
aluminum base, to
reducing tallow 50°F which tallow and oil
below its pour point are mixed into
then mixing a base solution under a
metal, such as controlled
barium, into solution temperature
NC 2
defective casing
gasket worn bearings
Stability-consistency
Penetration number number
wear on the braking
system damage to the teeth
due to the wrong
direction of rotation
an oil leak across the of the hydraulic
pump shaft packing motor
indicated by a
indicated by an release or break of
audible click the handle
allow interstage
cause damage in the leakage in the pump
stuffing box casing glands
Maximum and
minimum continuous
flow rates (lbs./hr.) All of the above
steam diesel
Reset Rate
"A" must be rotated "K" must be rotated
clockwise counterclockwise GS-0043
The internal parts of
The sheathing on the the pump and
hydraulic lines will hydraulic motor will
fracture. wear excessively.
Air ejector
condensate drain All of the above
Internal liquid
Pump efficiency will slippage will be
be increased. reduced.
annealing tempering
overtightening the
packing in one some rings being cut
adjustment too short
principal surveyor of
the American Bureau U.S. Salvage
of Shipping at the Association Survey
next U.S. port at the next U.S. port
overspeeding of the
hydraulic pump extended system life
any electrical
equipment mounted
on DH 32 steel
plating is required to the welding of any
be insulated from the DH 32 steel requires
plating and internally special welding
grounded instead procedures
C D GS-0073
liquid refrigerant
flooding back from
a clogged subcooler the cooling coil
The cutting surface
will become
Cracks may appear annealed by the cold
in the metal. water.
pneumatically tested
pneumatically tested at a pressure equal
at a pressure equal to 1 1/2 times the
to the working design pressure of
pressure of the tank the tank
proportional action derivative action
steam generating
capacity of a vessel's mechanical efficiency
boilers of the main unit
remain constant vary from section to
throughout the heat section throughout
exchanger the heat exchanger
4B 6B GS-0077
Parallel Circular
2 A1
locate the center on check the angle of
round stock thread cutting tools
Broaching Reaming
reversed pump
excessive suction lift rotation
faster actuator
extension speed all of the above GS-0107
entropy adiabatic heat
Planimeter Compass
flooding back of
water in the liquid refrigerant from
refrigerant the evaporator
straight-tooth bevel
zerol type type GS-0128
make up the joint
leave the old gasket without a gasket until
in and cover it with you can check with
Permatex the chief
liquid refrigerant
leaking suction flooding back from
valves the cooling coil
increase the
use larger electrodes amperage
diffuser siphon
abrasion corrosion
a modified Kingsbury
a diffusion ring thrust bearing
the incapacitation of
a yard worker due to
a boiler flareback All of the above.
deviation offset
at the narrowest
at the main lube oil point of the
pump discharge hydrodynamic wedge
the violation of
federal water
pollution law all of the above
The type of metal
being joined and the
The type of metal welding process
being joined only. being used.
Gear Rotary
hole has a 3/4" notch has a 3/4"
radius width GS-0021
phosphorescent
air and a soap hydrazine bisodium
solution to test all solution visible under
joints a black light source
spongy actuator
pump cavitation movements
efficiency to
decrease slippage to decrease
break loose scale
deposits formed on test for leaks in the
the tubes tubes
monthly daily
homiostatious
deformation gas eddys
component
misalignment pressure surges
scribed blued
insufficient cylinder
lubrication a loose piston
Allen Standard
dehydration condensation
Monel Tungsten
15 psig 20 psig
operating in deep
cavitation river channels
Downstream
pressure will be
greater than the
desired setting. All of the above. GS-0044
6 months or less in
30 months in the last each 12 month
36 months since period since it was
drydocking or haul last drydocked or
out hauled out
monitor off limit
conditions only when secure the machine
announced by an under relatively
audible and visual steady state
signal conditions
evaporation dissolution
The entire assembly
is of the split-type
construction. All of the above. GS-0135
hole will be drill will seize
undersized immediately
unfired pressure
auxiliary condenser vessel
6 X 4 inches 6 inches
output feedback
transverse nonwatertight
two position flow check and choke
control valves valves
water tallow
placing a hydraulic
aligning the main lock on the rams if
variable stroke pump there is a failure of
discharge/return with the hydraulic power
the main rams unit GS-0123
Provide all units with
a dirt trap and gate Wherever possible
valve in the supply install vertical runs
and a check valve on for condensate
the return. piping.
cherry red and
quench in water and carbonize it
stiffeners brackets
the mechanical
method for
positioning of the
variable stroke
the hydraulic control of the main
telemotor receiver pump GS-0123
air CO2
a total of 20 threads 1/20 of an inch long
with a pitch of 1/4 and 1/4 inch in
inch diameter
Lube oil will
discharge from the
heavy phase
The lube oil will discharge port to the
overheat and flash. sludge tank.
heat exchange
surfaces being orifices finely
directly in the path of atomizing the heated
the entering feedwater entering
feedwater the flash chamber
frames and beam
brackets deck longitudinals
30° 60°
frames bulkheads
sense crankcase
bleed off pressurized suction pressure as
oil from the cylinder the required
unloading feedback for proper
mechanism to allow operation of the
the cylinders to unloader control
unload device RA-0013
stringer doubler
Submerged tube
evaporators Basket evaporators
4 5
high pressure
centrifugal impeller impeller GS-0130
3 tons 4 tons
M L GS-0045
compressor would
air receiver indicated require more than the
pressure would be normal amount of
excessively low lubrication
60° 45°
Secure the stuffing
box sealing water Trip the three way
line. dump valve.
60 psig 75 psig
water hammer
tube sheet bowing damage
6 tons 8 tons
Spring "F" is
compressed. Valve "D" closes. GS-0045
installing a swing
installing eductors in check before each
all bilge rose boxes bilge valve
refrigeration service
heat exchangers oil fired boilers
width across the maximum thickness
bottom of the of the completed
weldment weld GS-0076
broach reamer
condense the
store the refrigerant refrigerant
3 4 GS-0125
contaminated sump
oil all of the above
maintaining a
constant flow and controlling the input
pressure input flow rate
file the plates to
replace the zincs if change the negative
deteriorated by 50% value
compensate for
upstream pressure
surges increase sensitivity GS-0045
55 GPM 18 GPM
3 2 and 3 GS-0059
7 inches 8 inches
two non-remotely
operated metallic
valves are installed
metallic shut off on either side of the
valves are welded to deck or bulkhead
nonmetallic hull regardless of
materials accessability
Ratchet Standard
point heel
Place the sensing
Chill the bulb in ice bulb in ice water and
water while then warm by hand.
observing the Observe flood-
compressor for an through and
increase in suction temperature change
pressure. at the suction line.
Square Triangular
Allen Torx
Utilizing an 'amp
clamp', the current
drawn may be
By using a variable adjusted by throttling
rheostat connected either the suction
across the 'comp valve of the
high' terminal, the compressor or the
current being drawn receiver tank outlet
is limited. valve. RA-019B
No problem exists as
a high vacuum
should be maintained
in the chamber
whose vacuum is be Suction line inlet
measured. strainer is obstructed. GS-0153
thin tubing or sheet drill rod and tool
metal steels
minimize sweating of
the suction line All of the above.
Authorized Official
Representative of the Representative of the
American Bureau of Naval Pollution
Shipping Control Office
pressure actuated,
condenser cooling
water regulating gas pressure
valve reducing valve RA-0014
aluminum monel
talc graphite
a decrease in the frosting at the suction
amount of frosting side of the
across the drier compressor
system replenishing
casing drain line GS-0049
first stage oil second stage oil
separator and drip separator and drip
pan pan GS-0153
Rake Wave
Keyway is to be cut
so as to give a sharp
rise from the bottom
of the keyway to the
shaft surface. All of the above.
be so arranged to
prevent excessive
not be located at the movement of its
end of a corridor in contents during
excess of forty feet periods of foul
in length weather
system to
automatically change
over to the hot gas compressor to short
defrost cycle cycle
The amount of
superheat added to
The force of the the gas discharged to
valve spring only. the condenser. RA-0007
Internal tank
pressure overcomes
the spring force in This device is never
item #2 causing it to exposed to excessive
open. internal pressures. GS-0153
Rod Flexible
F I RA-0005
raker wave
that if subjected to
that if subjected to a the standard fire test,
standard fire test, they would be
they would be capable of preventing
capable of preventing the passage of flame
the passage of flame and smoke for one
for one half hour hour
As the feedback
pressure through "O"
would decrease, the Component "C"
direct mechanical would be reseated,
linkage of "L", "C", allowing the increase
and "G" would cause in the force acting
the main valve "F" to above "H" to reseat
close. the main valve "F". RA-0015
The evaporator
blower speed is
determined by the
output of the current
coil. As the
compressor load is
increased, the blower Evaporator blower
speed is reduced to speed is determined
eliminate electrical by the evaporator
overloading. return air sensor. RA-0020
that if subjected to
that if subjected to the standards fire
the standard fire test, test, they would be
they would be capable of preventing
capable of preventing the passage of flame
the passage of flame or smoke for one
for one half hour hour
drawing jamming
rate at which
suction line of the condensation occurs
compressor will be within the coils will
abnormally warm increase
The microprocessor
has terminated the
defrost cycle after 45
minutes of elapsed The pneumatic relay
time, not having main contacts have
sensed a coil closed, causing the
temperature of unit to return to the
23.9°C. cooling cycle. RA-0020
coincide with a
decrease in the adversely affect the
suction line operation of the
temperature system RA-0018
This procedure is An accurate
done at the factory thermometer and
with tools not suction pressure
available to a gage are essential to
mariner. this process.
Only a double
Any bastard cut file. bastard cut file.
at the mid-horizontal
on the tail end of the level of a vertically
condenser outlet pipe run tail coil
Raker Wave
overboard discharge
flow control valve regulating valve GS-0153
Remove excess
lengths of the Heat shrink insulating
sensing bulb capillary material around the
tube from the device device once the bulb
to increase has been properly
sensitivity. secured.
Ultrasonic
examinations of the
The exposed steel of propeller may be
the shaft is to be performed in lieu of
protected from the required drydocking
action of the water by periods, provided
filling all spaces certified copies are
between the cap, distributed to the
hub and shaft with a proper regulatory
suitable material. bodies.
Steady, continuous
running for periods of Excessive refrigerant
12 hours or more. in system. RA-0020
As the modulation
Suction and valve closes, the
discharge pressures contacts at PCC
may drop below close, reducing the
expected normal speed of the
readings when the compressor and
unit is in the power increasing the overall
limit or modulating operating efficiency
cool mode. of the unit. RA-0020
thermal expansion
king valve valve
total force above "C"
is reduced below the
value of the total
force acting beneath
"C" all of the above GS-0155
For the unit to be
activated, "A" can The movement of "E"
only be moved will directly push "D"
initially in line with in a smooth vertical
the axis of the unit. motion. GS-0155
Subtract the
temperature of the
gas after the unit has
been pumped down
from its operating
temperature as
Multiply the travel of determined by the
the expansion valve evaporator test gage
stem by the during normal
conversion factor. operation. RA-0016
X J RA-0013
provide properly
grounded and use a combustible
electrically safe gas indicator when
portable lighting working in the tank
Both sensing
elements are anodes
used to provide the It is used to control
tank with corrosion the oil discharge
protection. mode. GS-0113
expansion valve
freezes in the closed refrigerant has too
position much oil in circulation
available horsepower
speed output of the at the "B" end would
"B" end would increase in
increase in proportion to
proportion to decreasing the angle
increasing the "B" of the "B" end tilting
end tilting box angle box towards zero GS-0057
Bronze Copper
11 to 12 psig 0 psia
yellow blue
a short length of rope
should be worn
around the waist to an explosimeter must
pull the worker to be provided to test
safety the tank atmosphere
industry accepted
term for the test procedure in
equipment which is which the relieving
used to collect oily capacity of the safety
bilge liquids valves are verified
The interval of
replacing the packing
will become more
frequent. All of the above. GS-0070
purple blue
equalize system
pressure for
pass liquid slugs compressor cycling
is capable of
pumping chunks of
cement that find their answers B and C
way into the system above
provide a sensing
provide recirculation signal to control the
at low flow pump discharge rate GS-0070
O3 Oz
centrifugal
compressors all of the above
provide variable
discharge air flow to direct compressed air
the compressed air from the air receiver
system depending on directly to the low
the load on the pressure cyclinder
system unloading device GS-0034
power take-off driven hydraulic hatch
lube oil pump supply pump GS-0058
stratosphere troposphere
3B 4A GS-0077
chunks of material
are moving through
the system and
transfer will stop inadequate fluidizing
momentarily of the weight material
necessity to
positioning, directly construct the rudder
aft of the propeller in one large casting GS-0101
pump should
discharge directly to cylinder should
the resevoir retract GS-0041
micro ohms in
tank fluid level condensate
chunks of material
are in the system and
will stop the flow satisfactory operation
momentarily of the system
To reduce the
amount of free To prevent list and
communication stability problems
therefore, reducing when receiving half a
the center of gravity load of fluid from the
of the OSV. rig.
close chatter
reduce the chances
force the remaining of any thermo-
liquid out of the hydraulic lock
receiver and into the occurring during the
system defrost cycle RA-0018
R-12 R-123
90% 99%
do not need to
either active or recover the
passive refrigerant
R-502 R-123
the system
compressor must be
working to use
system dependent
devices, the system
compressor may or
may not be
operational when
self-contained there is no difference
devices are used between the devices
venting to
atmosphere, cannot
high and low side be recovered
recycling recovering
$25,000 $50,000
Psychrometer Areometer
schedule 80 heavy 3/4-10 NC threaded
iron pipe stock GS-0088
weight of the
armature spring force
R-134a R-227
D E GS-0009
Type I or Universal
technician All of the above
R-134a R-227
be greatest at dew
remain unchanged point
R-134a R-143a
must be repaired if
the annual leak rate do not have to and
is 15% of the total are not required to be
charge repaired
14-Nov-94 14-Nov-99
26 gpm 91 gpm
designed to be of
lesser weight and
size when compared
with conventional
units producing the all of the above are
same torque correct GS-0116
assist in producing
water free
compressed air all of the above
30 pounds 20 pounds
degree of superheat
temperature in the of the gas leaving the
refrigerated space evaporator
HCFC-22 HFC-134a
carbonization
resulting from air in
the system gasket breakdown
may never be cross- may be connected if
connected by any they are used only
means for wash water
251 gpm 31 gpm
copper plating
head gasket caused by moisture
breakdown in the system
C D GS-0118
moisture acids
30 gpm 24 gpm
C F RA-0005
40 gpm 46 gpm
88 gpm 44 gpm
38 gpm 28 gpm
moisture air
noncondensable
gases refrigerant oil
red orange
15 psig 25 psig
Leave some
refrigerant in the
system to prevent the
Insure that the water water from
is drained or contaminating the
continually circulating referigerant if there is
to avoid freeze-up. a leak.
in the liquid line in the vapor line
bypassing the bypassing the oil
expansion valve separator
red orange
condenser compressor
18 26 RA-0018
air and moisture to rupture disk to
enter the reciever rupture
number 3 and 4
shots of chain all of the above
29 30 RA-0018
10 psig 15 psig
132 gpm 264 gpm
compressor evaporator
18 26 RA-0018
25 gpm 32 gpm
70% 75%
59 gpm 96 gpm
407 gpm 121 gpm
47 gpm 61 gpm
reduce flooding of
the receiver at low defrost the
loads evaporator coils
29 17 RA-0018
10 psig 15 psig
40 gpm 46 gpm
13 20 RA-0018
through the
through a leaking compressor shaft
rupture disk seal
prevent dry material
from being
discharged on deck All of the above
29 30 RA-0018
When there are small
air leaks in the When the oily-water
discharge piping, the separator is in the
effectiveness of the process mode it will
separator will greatly effectively handle
reduced. emulsions. GS-0113
high ambient
system leaks temperature
38 gpm 55 gpm
16 19 RA-0018
77 gpm 840 pm
47 gpm 93 gpm
29 30 RA-0018
29 30 RA-0018
32 gpm 49 gpm
To prevent injury
when pressurized air
discharges from the
open end of the hose All of the above
50 gpm 93 gpm
Cooling the air to a Heating the air and
point below dew then cooling it to a
point, then reheating point below dew
it. point.
80 gpm 27 gpm
32 gpm 25 gpm
short cycle on the
water low pressure short cycle on the
switch high pressure switch
50 gpm 99 gpm
23 gpm 40 gpm
154 gpm 175 gpm
55 gpm 38 gpm
61 gpm 51 gpm
88 gpm 20 gpm
reduction in
condenser air flow fully closed discharge
(dirty condenser) service valve
59 gpm 50 gpm
a minimum of 15 psi
constant viscosity to all parts of the
lubrication system
18 gpm 72 gpm
19 gpm 7 gpm
25 gpm 98 gpm
Dichlorodifluorometh Monochlorodifluorom
ane ethane
maintain constant
evaporator coil
maintain a constant pressure
degree of superheat independent of
at the evaporator coil suction pressure
outlet variations
open the discharge open only the valve
valve service port by connected to the
closing the service discharge service
valve approximately fitting on the outlet of
1/4 to 1/2 of a turn the king valve
recycled destroyed
53 gpm 25 gpm
a 25 ton air
conditioning plant
provided it does not
meet the criteria for a each of the above
TYPE II appliance. answers is correct
49 gpm 98 gpm
circulate the mud to
prevent barite from Prevent barite from
settling damaging the pump
providing a central
suction point to the
liquid mud pump All of the above
The separator
The separator operation would
operation would stall continue as valve
do to the presence of 'V4' is only used
water at the shorter during the remote
probe of item "S". manual mode. GS-0113
94 gpm 47 gpm
weight temperature
36 gpm 18 gpm
21 gpm 85 gpm
sensing the sensing the
superheat in the tail temperature in the
coil liquid line
11 gpm 43 gpm
251 gpm 31 gpm
remove entrained
water remove wax and gum
18 gpm 72 gpm
regulation of the
back-pressure valves cooling water
The power element
of the expansion
valve has lost its
charge due to a These start-up
break in the capillary characteristics are
tube; therefore, it is normal and no
necessary to change additional actions are
the power element. necessary. RA-0018
through high
pressure piping at "A"
and then internal
ports provided in the via hydraulic hoses
housing assembly connected to the
"U" orifices in "B" GS-0116
14 gpm 28 gpm
a pneumatically
operated tank used
to transport liquid drill
mud All of the above
Low discharge
The inability of the pressure and a
unit to properly pump normal or high
down the high side. suction pressure. RA-0018
126 lbs. 151 lbs. GS-0110
35 gpm 20 gpm
25 psi 35 psi
produce a higher
increase the purity of than normal brine
the distillate concentrate GS-0053
allow the oil
accumulated to exit
the device, while prevent separated oil
remaining separated from mixing with the
from the liquid incoming bilge water GS-0153
Using an 'amp
clamp', determine if
the electric drip pan
Change the rotation heaters are
of the condenser ungrounded and
fans. operating correctly. RA-0018
66 gpm 33 gpm
"H" were to be
removed and the
system operated for
thirty minutes without
"B" is over tightened it being replaced GS-0118
N O GS-0111
67 gpm 17 gpm
washed with an
ammonia and alcohol grounded to the
solution compressor
an excessive amount
of oil in the all of the above are
crankcase correct RA-0018
L M GS-0160
a pneumatically
operated tank used
to transfer dry,
pulverized drilling
materials All of the above
49 gpm 98 gpm
main bearing of the prime mover drive
compressor pulley
J K GS-0160
checking for
explosive gases all of the above
21 gpm 42 gpm
G M GS-0111
to precharge the
bottom of the
pressure vessel with
to drain moisture and dry nitrogen prior to
dirt from the bottom discharging bulk
of the tank material GS-0163
L P GS-0111
54 gpm 81 gpm
62 gpm 16 gpm
25 gpm 98 gpm
11 gpm 42 gpm
"E", "F", "B" and "D" "E", "F", "A", "B" and
open and all other "D" open. all other
valves closed valves closed GS-0162
raise the refrigerant
cool the suction saturation
vapor returning to the temperature in the
compressor evaporator
91 gpm 26 gpm
15 gpm 59 gpm
Both I and II Neither I nor II
95 gpm 27 gpm
94 gpm 47 gpm
L P GS-0111
59 gpm 24 gpm
77 gpm 32 gpm
36 gpm 9 gpm
86 gpm 57 gpm
39 gpm 25 gpm
73 gpm 44 gpm
522 tons 1216 tons
84 gpm 50 gpm
D L GS-0111
78 gpm 47 gpm
31 gpm 52 gpm
double-seat poppet
valve reed valve
45 gpm 18 gpm
19 gpm 7 gpm
I J GS-0111
Gate Butterfly
54 gpm 40 gpm
operating lever is
parallel to the flow
when open and
perpendicular to the valve seat can be
flow when closed relapped as needed GS-0055
C G GS-0009
8 gpm 33 gpm
become
supersaturated at give up moisture as
high relative humidity condensation
97 gpm 24 gpm
oil scraper ring
stuffing box for a mechanical shaft
crosshead engine seal GS-0116
51 gpm 31 gpm
56 gpm 34 gpm
quickly opened by
quickly opened when moving the control
the control lever is lever by one-quarter
rotated one full turn of a turn GS-0055
16 gpm 8 gpm
33 gpm 25 gpm
closing the high opening the high
pressure cutout pressure cutout
switch switch
28 gpm 18 gpm
F G GS-0009
right hand turning
right hand facing tool tool GS-0009
perform a left-cut
form a right-cut rough turning
square shoulder operation GS-0090
F G GS-0009
C F GS-0009
C F GS-0009
right-cut side-facing
tool left-cut roughing tool GS-0090
125°C 99°C
87 gpm 73 gpm
E F GS-0009
internal threading
tool universal turning tool GS-0090
49 gpm 181 gpm
32 gpm 43 gpm
E F GS-0009
right-cut side-facing
tool left-cut roughing tool GS-0090
right-cut side-facing
tool left-cut knurling tool GS-0090
remove entrained
water remove wax and gum
52 gpm 19 gpm
94 gpm 78 gpm
40 gpm 48 gpm
66 gpm 76 gpm
spring-loaded relief
high pressure cutout valve
universal turning
parting tools tools GS-0090
29 gpm 49 gpm
27 gpm 95 gpm
75 gpm 50 gpm
maintain a minimum
of 15 psia difference
bleed excess air from between the aeration
the top of the tank unit and the top head GS-0163
E G GS-0009
pumping all
refrigerant to the exhausting it to the
receiver atmosphere
Check valve Butterfly valve GS-0047
39 gpm 44 gpm
57 gpm 67 gpm
provide a protective reduce electrolytic
coating on heat action on heat
exchanger surfaces exchanger metals
evaporator condenser
50 gpm 37 gpm
64 gpm 77 gpm
sense discharge
temperature to
initiate the oil control the operation
discharge mode of the internal heater GS-0153
19 gpm 78 gpm
Determines the
conductivity of the Measures the voltage
dissolved oxygen. of the chloride ions.
heat exchange
surfaces being orifices finely
directly in the path of atomizing the heated
the entering feedwater entering
feedwater the flash chamber
9 gpm 25 gpm
nitrogen hydrogen
carryover in first
erosion of item "2" effect shell GS-0053
82 gpm 55 gpm
68 gpm 56 gpm
tailstock chuck
54 gpm 36 gpm
54 gpm 90 gpm
knurling swaging
55 gpm 41 gpm
24 gpm 12 gpm
C D GS-0031
23 gpm 91 gpm
55 gpm 16 gpm
C D GS-0031
24 gpm 40 gpm
D C GS-0031
39 gpm 50 gpm
C D GS-0031
cutting plane line phantom line GS-0006
27 gpm 65 gpm
broach tap
the temperature at
which the grease
would become the depth to which a
sufficiently fluid to fill cone would penetrate
the voids of a a sample of grease in
standard ball bearing 5 seconds
C I GS-0111
C D RA-0012
36 gpm 71 gpm
120° apart 180° apart
The pump packing Pump capacity is
will fail causing reduced and overall
irrepairable damage efficiency will be
to the pump shaft. increased.
Thermal expansion
Suction line valve valve
change in control
pressure to modulate
the discharge of proportional
compressed air to modulation of the
the atmosphere compressor speed GS-0119
as a square root to maintain a
extractor when constant flow
variable ratios are differential across a
present in the turbine- driven,
processing system centrifugal pump GS-0052
increasing the
volumetric efficiency all of the above
frequency of fluid
changeover all of the above
equalizing pressures
amount of high exerted on auxiliary
pressure steam valve "D" by high
admitted beneath the pressure steam and
diaphragm "E" by the reduced pressure
auxiliary valve "D" steam flow GS-0044
79 gpm 23 gpm
Exchange part "L" for
one that is upward Exchange part "G"
seated. for a heavier force. GS-0043
72 gpm 36 gpm
34 gpm 57 gpm
ram reservoir
minimizes the
probability of air
being drawn into the
pump suction all of the above
be provided with
three to five 1/2 inch
holes in the vertical,
be arranged to suction line to
develop the prevent pump
theoretically starvation should the
maximum attainable strainer become
vacuum fouled
viscosimeter pneumercator
piping pump
provide a place for
contaminants to
settle out all of the above
Detented position
valve Sequencing valve
directional control
valve regenative valve
J K RA-0005
directional control
valve power valve
85 gpm 51 gpm
Detented-position Counterbalance
valve valve
52 gpm 15 gpm
valve will drift to the
valve will drift to the opposite position
center position changing the
stopping any further direction of output
output of the system motion of the system GS-0035
Screw Centrifugal
offset solenoid,
rotary, directional directional control
control valve valve GS-0035
62 gpm 31 gpm
38 gpm 86 gpm
compound, pressure-
relief valve sequence valve
42 gpm 27 gpm
fluctuating pump
discharge pressure in
insufficient external response to normal
pump slippage load variations
N O RA-0015
45 gpm 78 gpm
compressor will
shutdown on the high
discharge pressure
cutout switch king valve will open
varying condenser
water flow rate all of the above
of no consequence
as the compressor
lube oil pressure is
not used in the
operation of the
the highest normal capacity unloading
pressure system. RA-0013
69 gpm 83 gpm
25% 0% RA-0013
25 gpm 98 gpm
point of condensation
will be moved closer steam pressure set
to the condensate point will
outlet of the heat automatically be
exchanger increased GS-0002
55 gpm 41 gpm
17 gpm 68 gpm
25 inches of hg
0 to 1 psig vacuum
right-cut threading
tool left-cut roughing tool GS-0090
9 gpm 38 gpm
right-cut side-facing
tool left-cut roughing tool GS-0090
19 gpm 7 gpm
right-cut side-facing
tool left-cut roughing tool GS-0090
17 gpm 68 gpm
25 gpm 98 gpm
183 pm 46 gpm
52 gpm 19 gpm
temperature limiting
control device set for
not more than 210° audible high water
Fahrenheit level alarm
54 pm 216 gpm
hygrometer hydrometer
85 pm 51 gpm
lowest temperature
at which it vaporizes ability of a fuel to
enough to form an ignite upon injection
explosive air/vapor into a diesel engine
mixture cylinder
It forms a corrosive
It clogs fuel oil acid when mixed with
strainers more often. water or water vapor.
eccentric in the
at bearing top center bearing
C D GS-0111
Foamed
polyurethane of the
impingement type
supported on Chemically treated
perforated metal paper and waste in
rings. cartridges.
dehydrator trap
compensation sensitivity
8 hours 12 hours
24 gpm 94 gpm
Certificate of
Inspection operations manual
Certificate of
Stability letter Inspection
the designated
the galley personnel person in charge
produce a class I
mix R-12 and R-22 refrigerant
22 gpm 89 gpm
one-position two-position
differential-gap differential-gap
300°F 315°F
replaced rewound
Red Green
40 gpm 25 gpm
transversely intermittently
6 5 GS-0161
15 percent 20 percent
78 gpm 22 gpm
internal combustion
machinery used for
purposes other than
main propulsion
where the total
collective power is at
least 500 brake
horsepower all of the above
21 gpm 83 gpm
dichlorodifluorometha
ne desiccant
Opening and
Closing valve 1 backseating valve 1
isolates gage #7 from isolates gage #7 from
line 2. line 2. RA-0001
25 gpm 9 gpm
hogging sagging
25% 0%
disassembled
component in a one
point perspective parts without using
view hidden lines GS-0025
back off on the nuts
by the same amount shut off the sealing
to prevent scoring of line valves to
the shaft sleeve and diminish the outflow
notify the next watch of water from the
of the condition packing box
move stored oil
across the indicated
shift valve "L" to line filter to maintain the
up the fluid motor oil in a water free
relief valve condition GS-0160
When operating at a
160 foot discharge
head, the pump is
running at maximum
efficiency All of the above GS-0138
Extended area
Cloth bag extractor membrane filter
36 gpm 27 gpm
work velocity
Fitting #4 should be
connected to the
system high side. All of the above. RA-0001
The neutralization
number has
The alkalinity of the decreased below
oil has decreased. minimum levels.
white green
41 gpm 52 gpm
During periods of
During periods thrust high-pressure oil
loading. surge. GS-0172
provide dynamic
provide static head head pressure for
pressure for maintaining proper
maintaining proper high-pressure oil
control oil pressure pressure
83 gpm 35 gpm
Figure "9" Figure "8" GS-0165
Q R GS-0090
47 gpm 59 gpm
21 gpm 28 gpm
temperature of the
amount of refrigerant refrigerant after
in the system compression
53 gpm 21 gpm
The position of the
valve can only be The valve can only
determined locally be operated locally
during manual during manual
control. control.
62 gpm 37 gpm
3.75 4.75
49.4 59.4
4.2 5.2
hydrogen chlorine
At each biennial
At least once a year. inspection.
R-11 R-123
R-22 R-134A
R-22 R-11
dust or particle
an explosive masks would be
atmosphere would be required before
created entering the space
within 12 hours prior
to any international
voyage of 48 hours at all fire and boat
or more drills
having a high affinity
decreasing in for water which
viscosity at low requires it to be kept
temperatures in a sealed container.
R-500 R-134A
To protect the
To keep pressure at Thermal Expansion
a minimum Valve
3 years 5 years
Low refrigerant
Insufficent air flow charge
a crewmember was
placed on light duty
for two days due to a
sprained wrist and
was required to wear
a sling all of the above
54 gpm 27 gpm
width across the maximum thickness
bottom of the of the completed
weldment weld GS-0076
it is important to
never allow more remember that the
than 10 PSIG acetylene hose
pressure in the thread connections
oxygen hose are right handed
45 gpm 79 gpm
error feedback
deadband bias
feedback offset
deadband and deadband and
setpoint proportional band
feedback error
deadband feedback
16 gpm 8 gpm
The compressor will
deenergize on low System will pump
pressure cut off. down to the receiver. RA-0018
94 gpm 78 gpm
secure the
evaporator until the lower the feedwater
feedwater trip point temperature
temperature can be at the indicating
raised to 165°F or panel for the three-
more way dump valve
electrohydraulic feedback
servo potentiometer GS-0170
back pressure
regulator condenser
applying reduced
voltage to the motor all of the above
box temperature
king valve solenoid valve
absorbing any preventing flammable
flammable vapors in vapors from entering
the vicinity the tank
91 gpm 45 gpm
contaminated grease
is flushed from the
bearing housing all of the above
become
supersaturated at low absorb less free
relative humidity atmospheric moisture
Cold air can hold Heating a sample of
more moisture than air will increase its
warm air. relative humidity.
A class 4 fit always A class 1 fit always
has more threads per has fewer threads
inch. per inch.
permit internal
components that are
subjected to high
erosion conditions, to
insure the proper be replaceable
alignment of the thereby extending
pump coupling to the the service life of the
driver pump
A regulating valve
Varying the controls the quantity
temperature of the of chilled water
water to the cooling flowing through the
coils. air cooling coils.
maintaining a
continuous fluid level
over half of the outer installing oil rings on
race the ball bearings
20 gpm 24 gpm
Type III Type IV
18 gpm 74 gpm
lube oil to foam due
to the release of release of dissolved
dissolved refrigerant lubricant from the
in the lubricating oil refrigerant
the thermal
the compressor expansion valve to
suction to overheat malfunction
66 gpm 99 gpm
remove some
lower the cut-in refrigerant from the
pressure system
Calcium Sulfate
Sodium Nitrate brine. brine.
compressor condenser
internal threading
tool universal turning tool GS-0090
Steel pipe can
transfer heat more A gas can transfer
efficiently than heat more efficiently
copper pipe. than a liquid.
48 gpm 97 gpm
5.112 inch 6.112 inch GS-0092
11 gpm 35 gpm
hydrogen nitrogen
91 gpm 26 gpm
27 68 GS-0143
80 gpm 96 gpm
20 gpm 88 gpm
5A 6A GS-0077
maintain back
pressure in the
evaporator coils at a
pressure higher than A bellows operated
the remaining coils in condenser water
a multi-box system regulating valve RA-0006
variable output,
single direction flow bi-directional flow
pump pump GS-0068
improved operating
slight foaming at the conditions at the
distillate feed pump brine pump
Condensed vapor
from the second-
effect Salt water
opened hydraulically
and held open by
spring action
engaged by spring whenever the
action plus hydraulic electrical supply is
pressure secured
discharge of a
secondary hydraulic
discharge of the pump specifically
compressor lube oil installed for this
pump operation RA-0013
discharge pressure
of the compressor the compressor
lube oil pump suction pressure RA-0013
must be destroyed,
returned to the as it can no longer be
system used
increase capacity
during times of peak heat loss due to
demand insufficient insulation
an automatic
hydraulic method
spare telemotor when changing over
system steering gear pumps GS-0123
excessive amount of
partially blocked non-condensable
thermal expansion gases trapped in the
valve condenser
caused by pitting of
the pump internals
due to operation with a result of a clogged
acidic oil discharge filter
bi-directional flow single stage constant
pump flow pump GS-0096
counterbalance
valve, ball check ,
counterbalance valve failed to close GS-0161
to cover an expired
permanent Certificate
of Inspection
provided that the
certificate did not
expire within 15 days
after the vessel left
the last port of the U. under all of the
S. above situations
A reinspection of a
vessel holding a valid
two year Certificate
of Inspection is
normally conducted
between the tenth
and fourteenth
months of inspection
date. All of the above.
3/8 inch 1/2 inch
13 16 RA-0012
A flow is developed
by imparting kinetic They operate more
energy to the fluid by efficiently when
the rotation of an mounted in a
impeller. horizontal position.
operating
continuously for 60
minutes after a closing all connected
power failure valves three times
operating or loading valve diaphragm
pressure tension GS-0051
stiffeners rabbits
absorb sudden
changes in hydraulic
act as an oil and fluid flow occurring in
water separator the system
nitrogen carbon
check for a receiver
outlet valve which check for a defective
may be partialy high pressure cut-out
closed switch
straight-tooth bevel
zerol type type GS-0128
frequency
accelerometers synthesizers
pressure differential
thermal radiography analysis
10.5 14.5
61 101
10.5 14.5
water density
gas convection differences
15 seconds 20 seconds
The component
labeled "D" would be
attached to the
rudder stock. all of the above GS-0178
counter-sinking knurling
48 gpm 58 gpm
If neither solenoid is
energized, the pump
drains oil back to the
sump through "G". All of the above. GS-0041
If neither solenoid is
energized, the pump
drains oil back to the
sump through the
directional spool
valve. All of the above. GS-0041
all-soft blade - 24 hollow core blade -
teeth pitch 32 teeth pitch
15 psi 25 psi
an air cushion in a a pressure regulator
hydro-pneumatic in the pump suction
surge tank piping
C H GS-0177
L D GS-0177
C D GS-0179
C D GS-0179
efficiency to
decrease slippage to decrease
64 84
Operating oil
A vacuum condition temperature is
has developed in the determined to be
reservoir. below normal.
15 knots 20 knots
Pressure-reducing
Sequence valve valve
suction side
connection must stuffing box should
guide the liquid to the not be allowed any
lantern rings water leakage
Repairs to containers
used in chemical
processes, especially
strong alkaline
solutions, are
effectively
accomplished with
braze welding. All of the above.
in short reasonable
lengths for the
purpose of flexibility
only all of the above
Raising adjusting
screw "G". All of the above. GS-0044
semi-balanced
rudder full balanced rudder GS-0131
higher relative
higher air circulation humidity
aluminum zinc
precharge the
remove all but the cylinders of an air
frictional load of an compressor prior to
air compressor at the start-up of the
start up unit GS-0029
deterioration of the
packing due to
excessive tightening all of the above
compressor receiver
adjust the
compressor adjust the
discharge pressure compressor suction
to meet load pressure to meet
demands load demands
Less complex to
Less scale formation maintain and operate
R-123 R-22
show no immediate
close to a preset change in its
minimum opening operation
The compressor
The receiver outlet. discharge.
32 minutes 36 minutes
Number of occupants