You are on page 1of 26

Solar Power System

COMPANY THE DEVELOPMENT OF ENTERPRISES

PROFILE
1998
Founded in 1988

15000 ㎡
Factory covers an area of 15,000 square meters with automatic production technology

60000 +
Monthly Production 60000 pcs

100+
Must serves more than 100 countries and regions around the world

MUST ENERGY Established in Shenzhen, China in 1998. Which is a leading manufacturer of power protection products and service solutions
including Uninterruptible Power Supplies (UPS), Power Inverters, Solar Inverters, Charge Controllers, Batteries and Automatic Voltage
Regulators(AVR).

MUST has two R&D centers in Shenzhen and Foshan. It has more than 100 patents and can provide customers with advanced product
development and design, comprehensive product development and testing, and automated information production. Branches and UNPROFOR,
distributed around the world, provide users with professional logistics support for solutions, technical training and service support, which can
serve customers more conveniently and quickly.

MUST has established an enviable reputation based on passion, quality, innovation, reliability and integrity for power protection technology,
service excellence, complete customer satisfaction and confidence unmatched within the industry.

Shenzhen Anbotek Compliance Laboratory Limited


Page 1 of 26 Report No.R011607253S
improving life through standards DZ52KU

CERTIFICATE Standards Organisation of Nigeria Conformity Assessment Programme


Of Conformity
Low Voltage Directive 2014/35/EU
Product Certificate (Licensed)
APPLICATION FOR TEST REPORT Registration No.: ATSZAHS181106003 PC(L) No.: NGA-LCN19-014020-V0
On Behalf of This document is not and does not substitute in any

Certificate of Suitability
respect the SONCAP Certificate required for Customs Issuance Date: 18/03/2019
Report No.: SZAHS181106003-01 Clearance Expiry Date of Certificate: 17/03/2020
INVERTER/CHARGER Version: 0
Applicant : SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Model: EP30-1KW PRO, EP30-2KW PRO, EP30-3KW PRO, EP30-4KW PRO,
EP30-5KW PRO, EP30-6KW PRO
5F. Building 11. Rundongsheng Industrial Park. Longzhu.
Xixiang. Baoan District. Shenzhen. Guangdong. China
*Addendum* Name of
SHENZHEN MUST ENERGY TECHNOLOGY CO.,LTD
Manufacturer:
Certificate No.: SAA191172 Address: 5F,Building 11,Rundongsheng Industrial Park,
Product : SOLAR INVERTER
Longzhu,Xixiang,BaoanDistrict,Shenzhen,Guangdong, China
Identification : Model No. : PV18-3024VHM, PV18-2024VHM, Date of Issue: 19 June 2019
PV18-3024HM, PV18-2024HM Phone No.: 0086 755 29022691
Class Description: Non-Declared
Product Description: Energy Storage Inverter E-mail: sales@mustups.com
Trade Mark : MUST
Fax No.: 0086 755 29022683
Prepared For : SHENZHEN MUST ENERGY TECHNOLOGY CO.,LTD Rating : AC Input: 230V Additional Models Rating Tin Number:
4-5F, Building A11, Yusheng Industrial Park, NO.467, PV MPPT Voltage Range: 30~130VDC, 80A PH10-4248A Input: Max 580Vdc, MPP Voltage Range: 120-550Vdc, 11/11A, Isc: 15/15A RC/BN Number:
Section XiXiang, National Highway 107, XiXiang,Baoan Output: 230V AC, 3KW Output: 230V~ 50Hz Max 19.1A, 4.2kVA Factory Audit 5F,Building11,Rundongsheng Industrial Park, Longzhu, Xixiang, Baoan
District, Shenzhen, China Battery: Lead-acid/Lithium, 40-60Vdc, 48Vdc, Max Battery charging current: 50A, 2500W
Site Address: District,Shenzhen, Guangdong, China
Test Standards : EN 62109-1: 2010; PH10-4648A Input: Max 580Vdc, MPP Voltage Range: 120-550Vdc, 11/11A, Isc: 15/15A
EN 62109-2: 2011 Factory Audit
Output: 230V~ 50Hz Max 21A, 4.6kVA 12/03/2019
Date:
Battery: Lead-acid/Lithium, 40-60Vdc, 48Vdc, Max Battery charging current: 50A, 2500W
The certificate of conformity is based on an evaluation of a sample of the above PH10-5048A Input: Max 580Vdc, MPP Voltage Range: 120-550Vdc, 11/11A, Isc: 15/15A Item HS Code Product Description (Description, Brand, Model Country of Standard
Prepared By : Shenzhen Anbotek Compliance Laboratory mentioned product. Technical report and documentation are at the applicant’s Output: 230V~ 50Hz Max 22.8A, 5kVA No. No.) Origin Reference
disposal. This is to certify that the tested sample is in conformity with Low
Limited Voltage Directive 2014/35/EU relating to electrical equipment designed for use
Battery: Lead-acid/Lithium, 40-60Vdc, 48Vdc, Max Battery charging current: 50A, 2500W
1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, within certain voltage limits. The certificate does not imply assessment of the 1 850440 INVERTER/CHARGER Brand: MUST Model: EP18-**** CN IEC 62109-1:2010
Nanshan District, Shenzhen, Guangdong, China series-production of the product. The applicant of the certificate is authorized to
Tel: (86)755-26066554 use this certificate in connection with EU declaration of conformity specified in 2 850440 INVERTER/CHARGER Brand: MUST Model: EP**** CN
IEC 60950-
1:2005+A1:2009+A2:20
Fax: (86)755-26014772 Article 15 and Annex IV of the Directive. 13

Remarks: “****” STANDS FOR FIGURES 0-9


Certified by
Carey CHEN

Authenticated By: Issuing Office: Cotecna Inspection SA


Dec. 13, 2018 Terry Tian
Date Manager

The CE Marking may only be used if all relevant and


Cotecna Ref
effective EU Directives are complied with Number:
CN1905242-1-A

Date of Test: Jul. 07, 2016 to Aug. 18, 2016 Anbotek (Guangzhou) Compliance Laboratory Limited For and on Behalf of
ppr This document is issued under the authority of the SONCAP for and on behalf of the Standards Organisation of
Date of Report: Aug. 18, 2016 Rm.508, Bld.2, No.232, Kezhu Road, Science City, Economic & Technology SAA Approvals Pty Ltd A A ova Nigeria (SON)
SA

Development Area, Guangzhou, Guangdong, China. 510663Tel: (86)020-82575416


ls

Report Number: R011607253S Fax: (86)020-82575023 CERTIFIED


Http://www.anbotek.com Email:service@anbotek.com
SAA Approvals Pty Ltd as accredited by JAS-ANZ under
ISO/IEC 17065 certifies in accordance with the SAA Approvals
Electrical Product Safety Certification Scheme that the product
nominated in this certificate complies with standard/s listed. This inspection has been performed on the goods for which it was requested according to our professional standards and to the best of our knowledge on the date and at the place it was
When using the RCM the requirements of all relevant parts performed, within the scope of instructions received. This inspection does not release seller(s) and/or supplier(s) and/or shipper(s) and/or other parties involved from their respective contractual
of AS/NZS 4417 applicable to the article must be fulfilled. obligations and does not prejudice the buyer(s)/receiver(s)’ right to claim, under applicable law and contract, compensation from seller(s)/supplier(s)/shipper(s) regarding any defects not detected
Issued: 19-06-19 191172/2
during our inspection or occurring thereafter. This inspection is also subject to COTECNA Terms and Conditions of Business 2018. (http://www.cotecna.com/en/About-Cotecna/Terms-Conditions).
For SAA Contact Details and to verify this Certificate go to:
Headings and titles in this certificate/report are for reference only and the findings contained herein prevail as stated
Shenzhen Anbotek Compliance Laboratory Limited www.saaapprovals.com.au www.jas-anz.org/register
Page 1 of 1
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

-4-
ON/OFF Grid High frequency Hybrid Solar Inverter Solar Power System

PH1000 Series (3.6-5KW)


Specification

MODEL PH10-3648A PH10-4248A PH10-4648A PH10-5048A


Features
RATED POWER(W) 3600 4200 4600 5000
• Wide range of MPPT voltage:120-550V
Nominal Battery System Voltage 48 48 48 48
• Multiple operation modes: Grid-tie,off grid and grid-tie with back up Maximum recommended DC power(W) 4100 4800 5300 5750
• Support LCD display&Smart LCD setting Nominal DC operating voltage(V) 360

• Available Export control CT sensor function Maximum DC voltage(V) 580


MPPT voltage range(V) 120~550
• Multiple communications:USB,RS485,GPRS and wifi etc. PV
INPUT(DC) Maximum input current(A) 11/11
• Monitoring inverters Freely Via computers or mobile phones
Maximum short circuit current(A) 15/15
• Full protection function:Over-voltage,over-frequency, over-current, No.of MPP tracker 2
over-temperature,and AC short-circuit automatic protection
Strings per MPP tracker 1
• Intelligent BMS battery management function Nominal AC output power(W) 3600 4200 4600 5000
• Fanless low-noise design. Nominal output voltage(V);range(V) 220\230\240;180-280
• IP65 Dust-proof and water-proof AC grid frequency(Hz);range(Hz) 50\60;45~55\55-65

INVERTER Nominal output current(A) 15.7 18.3 20.0 21.8


OUTPUT(AC) Maximum output current(A) 16.4 19.1 21.0 22.8
Total harmonic distortion i(THDi) <3%
Introduction
Power factor at rated power 1
This is a flexibly and intelligent energy storage solar inverter with wide range of MPPT Voltage. Displacement power factor 0.8leading ~ 0.8lagging
Combining functions of off grid and on grid. This hybrid solar inverter can power all kinds of appliances in home or office, also can use in power station. Output Rated Power 2300
Nominal output voltage(V);accuracy range 230±1%

BATTERY Output ferequency(Hz);accuracy range 50/60(optional)±0.2%


MODE OUTPUT(AC) Output rated current(A) 10
Back panel printing description Solar system connection
Output waveform Pure sine wave
Total harmonic distortion v (linear load) <3%
Battery type Lead-acid battery \ Lithium battery
1 2 SOLAR PANELS
Battery voltage(V) 48
1. The inverter operation status indicator
Battery voltage range(V) 40~60
BATTERY
2. Battery indicator & Charging curve 3-stage adaptive with maintenance
3. WiFi status indicator CHARGER
Over-current protection / Over-temperature protection Yes \ Yes
4. Fault indicator Laptop Maximum charging/discharging power(W) 2500 2500
4 3 Maximum charging/diacharging currernt(A) 50 \ 50
Maximum efficiency 97.3%
Lighting
EFFICIENCY Euro-efficiency 96.8%

AC OUTPUT MPPT efficiency 99.9%


5 6 7 8 9 10
DC switch rating for each MPPT Yes
Air-conditioner
Grid monitoring Yes

PROTECTION Output over current protection Yes

TV
DEVICES Output overvoltage protection-varistor Yes
ELECTRIC
METER Ground fault monitoring Yes
Integrated all-pole sensitive leakage current Yes
Fans
Dimension(W/H/D)(mm) 480*420*215
BATTERY
(optional)
Net weight (kg) 25 25 27 27

DC connection H4 / MC4
GRID
AC connection Terminal Block
5. PV input terminals
Display LED+LCD
6. Battery input terminals and cover
GENERAL Communication interfaces Wi-Fi \ USB \ GPRS \ RS485
7. PV input switch
Ingress protection rating IP65
8. BTS terminals, BMS terminals, load monitor terminals,
Humidity 0~95% RH(No codensing)
dry contact terminals, CAN communication terminals,
Operating temperature range -20℃ +60℃ With derating above 45℃
USB terminal and cover
Cooling concept Natural
9. Wi-Fi commodule
Altitude <2000m
10. AC output terminals and cover

-5- -6-
High Frequency On Grid Solar Inverter Solar Power System

PH5000 Series (2.5-6KW)


Specification

Features MODEL PH50-2500 PH50-3000 PH50-3600M PH50-4200M PH50-4600M PH50-5000M PH50-6000M

• High Frequency On Grid Solar Inverter RATED POWER(W) 2500 3000 3600 4200 4600 5000 6000

Maximum recommended
• Pure sine wave output 2875 3450 4100 4800 5300 5750 7000
DC power(W)
• Rate power: 2.5-6KW Nominal DC operating voltage(V) 360

• MPPT efficiency up to 99.50% Maximum DC voltage(V) 550


PV Start voltage(V) 100
• Multiple communications: USB,WIFI etc INPUT(DC)
MPPT voltage range(V) 80~550
• Monitoring inverters freely via mobile phonese APP
Maximum input current(A) 11 11 11\11 11\11 11\11 11\11 11\11
• Fanless low-noise design No.of MPP tracker 1 2

• IP65 water-proof and dust-proof Strings per MPP tracker 1


Nominal AC output power(W) 2500 3000 3600 4200 4600 5000 6000
Maximum AC output power(VA) 2500 3000 3600 4200 4600 5000 6000
Nominal output voltage(V);range(V) 220 \ 230 \ 240;180-280
AC grid frequency(Hz);range(Hz) 50\60;45~55\55-65
Introduction Nominal output current(A) 10.9 13 15.7 18.3 20.0 21.8 26.1
GRID
OUTPUT(AC) Maximum output current(A) 11.4 13.7 16.4 19.1 21.0 22.8 27.3
PH5000 series PV inverters take full account of the needs of end customers, with excellent performance at the same time, use LED as inverter status
display, effectively improve product life. Using DSP digital control,could afford wide grid voltage range, have a full range of protection features; to Total harmonic distortion i(THDi) <3%
maximize the benefits at the same time, greatly enhance the reliability of the product.
Power factor at rated power 1
Displacement power factor 0.8leading ~ 0.8lagging

Back panel printing description Solar system connection AC connection Single phase
Maximum efficiency 97.2% 97.2% 97.4% 97.4% 97.4% 97.4% 97.4%
Euro-efficiency 96.8% 96.8% 97.0% 97.0% 97.0% 97.0% 97.0%
Continuous light Normal status EFFICIENCY
Green LED MPPT efficiency 99.5%
Flicker Waiting status
Self-Consumption night(W) <1
SOLAR PANEL
Blue LED Flicker Wifi normal communication DC reverse polarity protection Yes

Continuous light Fault status DC switch rating for each MPPT Yes(opt.)
Red LED Output over current protection Yes
Flicker Program of procedure or give an alarm
Output overvoltage
PROTECTION Yes
protection-varistor
DEVICES
Ground fault monitoring Yes
1. Operation normal (Green) HOME APPLICASES
Grid monitoring Yes
2. WIFI communication (Blue)
Integrated all-pole sensitive
3. Error display (Red) Yes
leakage current
4. DC switch CT Dimension(W/H/D)(mm) 262*368*155 262*368*155 355*412*153 355*412*153 355*412*173 355*412*173 355*412*201
1 2 3
(optional) PHYSICAL
5. PV input AC output L Net weight (kg) 10 10 13.5 13.5 14.5 14.5 16.5
6. WIFI connector N
Utility DC connection H4/MC4
7. PC USB connector AC connection Connector
INTERFACE
8. AC output Display LED
Communication interfaces Wi-Fi \ USB \ GPRS
Ingress protection rating IP65
Humidity 0~95% RH (No condensing)
Operating temperature range -25℃ ~+60℃ With derating above 45℃
ENVIRONMENT
Cooling concept Natural
Noise emission(typical)[dB] ≤25
Altitude <4000m
Topology transformerless

OTHERS Warranty Standard 5years/10 years(opt.)

Certificatesand approvals CE/IEC62109 CE/IEC62109 CE / IEC62109 / CQC


4 5 6 7 8

-7- -8-
High Frequency On Grid Solar Inverter Solar Power System

PH5000TM Series (7KW-15KW)


Specification

PH50- PH50- PH50- PH50- PH50- PH50- PH50- PH50-


Features MODEL
7000TM 8000TM 9000TM 10000TM 11000TM 12000TM 13000TM 15000TM
• Wide input voltage range from 160V-1000Vdc Rated AC output power 7000W 8000W 9000W 10000W 11000W 12000W 13000W 15000W

• IP65 protection degree Max.AC apparent power 7700VA 8800VA 9900VA 11000VA 12100VA 13200VA 14200VA 16500VA

Max.output current 11.1A 12.7A 14.3A 15.9A 17.5A 19A 20.6A 23.8A
• Integrated DC switch
Nominal AC Voltage 230V \ 400V
• DSP controller
AC Voltage range 184Vac-300Vac
• The maximum efficiency is 98.3% Output (AC) 50±5Hz
AC grid frequency range
• Multi MPP controller 60±5Hz

Power factor at Rated power 1


• WIFI monitoring stardand;
Adjustable displacement power factor 0.8leading...0.8lagging
• Easy installation
THDi @ Full load%THDv <1% < 3%

AC grid connection type 3W+N+PE

Introduction Max.DC power 8400W 9600W 10800W 12000W 132000W 14400W 15600W 18000W

Max.DC voltage 1000V


It is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner.
Start voltage 160V

PV voltage range 160V-1000V

Input Data MPP voltage rang 200V-1000V

Back panel printing description Solar system connection Full load voltage range 295V-850V 335V-850V 375V-850V 416V-850V 458V-850V 420V-850V 450V-850V 520V-850V

Max.input current 12.5A/12.5A 20A/10A


Number of independent MPP trackers /
2/1 2/2+1
1. Operation normal (Green) strings per MPP tracker
2. WIFI communication (Blue) SOLAR PANEL DC connection H4 \ MC4
3. Error display (Red) Max.efficiency 98.3% 98.4%
4. PV input
Euro weighted efficiency 97.5% 97.8% 98%
5. DC switch
EFFICIENCY MPPT efficiency 99.5%
6. WIFI connector
DC reverse polarity protection, Output over current protection, Output overvoltage protection-varistor,
1 2 3 7. USB Protection devices DC reverse polarity protection, DC switch rating foreach MPPT(opt.), Ground fault monitoring,
Integrated all-pole sensitive leakage current monitoring unit
8. RS485
Dimension(W/H/D)(mm) 500*428*200
9. AC output
Weight (kg) 22 24

Operation temperature range -25℃ -+60℃ with derating above 45℃


4 5 6 7 8 9 AC OUTPUT
Noise emission(typical) ≤35dB(A)

Altitude 3000m
GENERAL DATA
FEATURES
Self-consumption night < 1W

Topology transformerless

Cooling concept Natural

Environmental protection Rating Ip65

Relative humidity 100%

AC connection connector

Display LED

Features Interfaces:USB/WI-FI/GPRS/ RS485 YES \ YES \ Opt \ YES

Warranty Standard 5 years/10 years(opt.)

Certificates and approvals CE \ IEC62109

-9- - 10 -
Low Frequency On/Off Grid Hybrid Solar Inverter Solar Power System

PH3000 Series (9-12KW)


Specification

Features MODEL PH30-9048-T PH30-12048-T

• Rated power 9KW to 12KW Nominal Battery System Voltage 48VDC

• Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.) Rated output power 9000W 12000W

• Built-in MPPT 180A solar charge controller Output wave Pure sine wave

• MPPT Efficiency max 98% Nominal output voltage 230 VAC (P-N) \ 400 VAC (P-P)
• Combining solar system, AC utility, and battery power source to Nominal output current 13.0A per phase 17.4A per phase
supply continuous power INVERTER
OUTPUT Nominal output frequency 50 Hz \ 60 Hz
• Multiple operations: basic Grid-tie, Off-Grid, Grid-Interactive
Rate of wave distortion(THD)(Linearity loads) Off grid≤2%; Grid discharge ≤3%; Grid charge ≤3%
• Support CAN, RS485 monitoring function with free CD
Peak efficiency ≥93%
• WIFI/ GPRS remote monitoring (optional)
100%<load≤110%,30 minutes; 110%<load≤125%,1 minutes;
Overload capability
125%<load≤150%,30 seconds; load<150%,10 seconds; Short circuit,5 seconds

AC input maximum current 26.0A per phase 34.8A per phase

Introduction AC INPUT
Nominal frequency 50Hz \ 60Hz

Defaults 186Vac ~253Vac per phase;Narrow 174Vac ~272Vac per phase;


This model PH3000 Three-phase is a flexible and intelligent energy storage inverter which utilizes solar power, utility power, and battery power source Acceptable input voltage range
Wide 95Vac ~272Vac per phase
to supply continuous power. This is a multi-functional hybrid inverter which can power all kinds of appliances in home or office environment, including
motor-type appliances such as tube light, fan, refrigerator and air conditioner. The system generates electricity when it has sufficient sunshine, supplying Nominal Voltage 48VDC
power to your home and feeding any surplus power back to the Grid.
Low Voltage Protection Point Charger 34.0VDC; Inverter 40.0VDC

Back panel printing description Solar system connection BATTERY Absorption Voltage 50.0VDC

Refloat Voltage 54.8VDC


1 2 3 4 5
Float Voltage 57.2VDC

1. LCD Display PV Open Circuit Voltage 145VDC

2. Status Indicator SOLAR CHARGER Max Solar Charging Current 60A per channel
&
3. Charging Indicator
AC CHARGER Max AC Charging Current 60A per phase 80A per phase
4. Fault Indicator
Max Charging Current 120A per phase 140A per phase
5. Funtion Buttons
6. USB commnuication port Mounting Vertical
Laptop
7. CAN/RS485 commnuication Machine Dimension, W*H*D(mm) 392*828*629

8. BTS MECHANICAL
Package Dimensions (W*H*D)(mm) 513*1031*700
6 7 Lighting SPECIFICATIONS
9. Battery input
AC INPUT Net Weight (kg) 133 140
8 10. AC output breaker
AC OUTPUT Gross Weight (kg) 128 160
11. Grid breaker Air-conditioner

12. Grounding Communication terminal RS485/CAN bus

13. Grid Operation Temperature Range 0℃ ~+50℃


BATTERY TV
14. Grounding
OTHER Environmental Protection Rating IP20
15. AC output
Ambient humidity 0 -- 90% relative humidity(non-condensing)
16. PV input Fans
9
10 Altitude ≤2000m
11

Motor

SOLAR PANELS

12

16 15 14 13

- 11 - - 12 -
High Frequency On/Off Hybrid Solar Inverter Solar Power System

PH1800 Plus Series (2KW-5.5KW)


Specification

PH18-2024 PH18-3024 PH18-3048 PH18-4048 PH18-5048 PH18-5548


Features MODEL
Plus Plus Plus Plus Plus Plus
• Rated Power 2KW-5.5KW
Nominal Battery System Voltage 24VDC 48VDC
• Pure sine wave output
Rated Power 2000W 3000W 3000W 4000W 5000W 5500W
• Self-consumption and Feed-in to the grid
• Programmable supply priority for PV, Battery or Grid Surge Power 4000W 6000W 6000W 8000W 10000W 11000W

• User-adjustable battery charging current suits different types of batteries


Waveform Pure Sine Wave
• Programmable multiple operation modes: Grid-tie, off-grid and grid-tie
INVERTER OUTPUT AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(setting)
with backup
• Multiple communication for USB, RS-485, CAN Electric Current 8.7A 13A 17.4A 21.7A 23.9A
• Monitoring software & Wifi Kit for real-time status display and control
Inverter Efficiency(Peak) 93%
• Support parallel operation up to 3 units (available for 3KW-5.5KW 48V)
Transfer Time 10ms(For For Personal Computers) 20ms( For Other Home Appliance)

Voltage 230VAC

Introduction AC INPUT Selectable Voltage Range 170~280VAC(For Personal Computers), 90~280VAC(For Home Appliances), 184~253VAC(VDE4105)

PH1800 Plus series hybrid solar inverter, it can realize self-consumption and feed-in to the grid from solar energy with best solution according to your Frequency Range 50Hz/60Hz (Auto Sensing)
setting. During the daytime solar power can run your home appliances and if there is extra solar power it will feed-in to the grid or you can choose to
save them on the battery to backup when power failure or nighttime. Normal Voltage 24VDC 48VDC

BATTERY Floating Charge Voltage 27.4VDC 54.8VDC

Back panel printing description Solar system connection Overcharge Protection 30VDC 60VDC

Maximum PV Array Open Circuit Voltage 145VDC


1. LCD Display SOLAR PANELS

1 2. Status Indicator PV Array MPPT Voltage Range 30~130VDC 64~130VDC

2 3. Charging Indicator
Standby Power Consumption 2W
3 4. Fault Indicator
LAPTOP
4 Maximum PV Array Power 2000W 4000W
5. Function Buttons SOLAR CHARGER
5 &
6. Dry contact AC CHARGER Maximum Solar Charge Current 80A
LIGHTING
7. USB
Maximum Efficiency 98%
8. AC Input AC OUTPUT

9. AC Output PRINTER Maximum AC Charge Current 60A

10. PV Input
Maximum Charge Current 140A
11. Power On/Off Switch INVERTER
15 6 7 14 TV
12. Battery Input Machine Dimensions (W*H*D) 272*355*100 mm 297.5*468*125mm

13. Circuit breaker AC INPUT Net Weight(KG) 7.4 14


FANS MECHANICAL
14. Parallel connection port SPECIFICATIONS
Package Dimensions(W*H*D) 485*393*251mm 638*395*241mm
15. RS-485 Communication port
GENERATOR Gross Weight(KG) 9.5 16.4
BATTERY

Humidity 5% to 95% Relative Humidity (Non-condensing)

8 9 10
8 9 10 11 OTHER Operating Temperature 0°C ~55°C

Storage Temperature -15°C ~60°C

13 12 13 12 11

(2KW-3KW) (3KW-5.5KW)

- 13 - - 14 -
Low Frequency Split Phase Inverter Charger Solar Power System

PV3300 TLV Series (1KW-6KW)


Specification
PV33- PV33- PV33- PV33- PV33- PV33- PV33- PV33- PV33- PV33- PV33- PV33-
Features MODEL 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV
• Pure sine wave output
• Friendly user interface;MFD (multi-function display) Rated power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW

• 3 Steps charging Power factor 1


• Overload and short-circuit protection
Wave form Pure sine wave
• Set charging voltage/charging current.
Output voltage RMS 100V \ 110V \ 120VAC(200V \ 220V \ 240VAC)±10%
• Battery low voltage shutdown point can be set to 10/10.5/11V
• Set utility priority/ Battery priority Inverter Output frequency 50Hz or 60Hz (±0.3Hz)
• Set utility input wide/narrow range Output
Inverter efficiency (peak) >85%
• Inverter voltage can be set to 100/110/120;frequency can be set to 50/60Hz
• Set utility charging on/off switch Overload
100%<Load<110% (alarm 5min then stop output ) \ 110%<Load<125% (alarm 60s then stop output) \
Load > 125% (alarm 10s then stop output )
(1KW-3KW) (4KW-6KW) • Built-in 80A MPPT charger
Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 15000VA

Capable of starting electric


Introduction motor
1P 1P 1.5P 1.5P 2P 3P

This split phase inverter PV3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which Battery voltage 12VDC/24VDC 24VDC/48VDC 48VDC
matches AC 110VAC/120V single phase, or two phase 110VAC/120V 220V/240V; In LCD display, you can set output voltage, frequency, charging
voltage, charging current to design best use based on different loads applications; meanwhile, it has already built-in solar charge controller, you can take Minimum start voltage 11VDC/22VDC/44VDC
use of sunshine freely and save electricity bills.
Low battery voltage cut off (Low voltage fault code04)10\10.5\11V for 12V mode ; 20\21\22V for 24V model ; 40\42\44V for 48v model

Back panel printing description Solar system connection


Add 0.5V \ battery:(Low battery alarm one second one time)
(10 \ 10.5 \ 11V)+0.5VDC for 12V mode
Low battery voltage alarm
6 3 4 5 2 (20 \ 21 \ 22V) +1Vdc for 24v model
Battery (40 \ 42 \ 44V) +2Vdc for 48v model
Solar Panel

10

9
Add +1V\battery: (high voltage one second one time\after 30s fault 03)
8
1 (13.8-14.5V) + 1V for 12V model
High battery voltage alarm
(27.6-29V) + 2V for 24v model
7 (55.2-58) + 4V for 48v model

Power Grid

[ 1-3K Back Panel ] Save mode Loads ≤ 40W (110V) \ 80W (220V)

6 3 4 5 2 Input waveform Pure sine wave

Generator
Nominal input voltage 200Vac \ 220Vac \ 240Vac
10

9
Max input voltage 270Vac MAX
AC Input
Fridge
8
1 Mode
Input frequency 50Hz \ 60Hz (auto sensing)
7
Air-conditioner Efficiency (AC mode) >95% (load, full battery)

BAT input Transfer time AC to DC 15ms(typical)


[ 4-6K Back Panel ] Load
PC
BAT charge 12V 30A 45A 60A \ \ \ \
1. Battery -/+
TV
2. REMOTE PORT 24V 20A 25A 30A 40A 60A \ \
Charge
3. BTS Mode
Battery 48V \ \ \ 20A 30A 35A 40A
4. AGS Washing machine

5. USB Min charge current 10A. Change by every 5A


6. AC INPUT PROTECT: Input protect breaker
7. PV -/+ Dimensions (W*H*D) 277*196*466mm 277*186*621mm
8. AC OUTPUT: HOT1 - HOT2 200VAC/220 VAC/240VAC
9. AC OUTPUT: HOT2 - N 100VAC/110 VAC/120VAC Dimensions Ship Dimensions (W*H*D) 376*306*592mm 376*296*747mm

10. AC INPUT: HOT1 - HOT2 200VAC/220 VAC/240VAC


Warranty One year (standard), 2 years optional (IP20)

- 15 - - 16 -
Low Frequency Off Grid Solar Inverter Solar Power System

PV3000 MPK Series (1KW-6KW)


Specification
PV30-
PV30-1KW PV30-2KW PV30-3KW PV30-4KW PV30-5KW PV30-6KW
Features MODEL 1.5KW
MPK MPK MPK MPK MPK MPK
MPK
• Pure Sine Wave Output
12 24 12 24 12 24 12 24 48 24 48 24 48 24 48
• Built-in MPPT solar charge controller 80A Nominal Battery System Voltage
VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC
• Support Remote Control Box(optional)
Rated Power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
• LCD display ,easy to read how inverter operates on LCD screen
Surge Rating (20ms) 3KW 4.5KW 6KW 9KW 12KW 15KW 18KW
• 5-levels DIP switch ,offering customized performance
Capable Of Staring Electric Motor 1HP 1HP 1HP 2HP 2HP 3HP 3HP
• 9-levels battery selector ,Enable to charge Gel ,lead-acid battery Waveform Pure sine wave / same as input (bypass mode)
• DC(Solar)/AC prority optional 110V \ 120V \ 220V
INVERTER Nominal Output Voltage RMS 110V \ 120V \ 220V \ 230V \ 240VAC (±10% RMS) 220V \ 230V \ 240VAC
230V \ 240V
• 4 levels charge current adjustable OUTPUT
Output Frequency 50Hz/60Hz ±0.3Hz
• With BTS & AGS , optimazing battery performance & start generator
Inverter Efficiency (Peak) >88%
automatically Line Mode Efficiency >95%
• Power saver Switch , Enable to minimize standby consumption Power Factor 1.0

Typical Transfer Time 10(max)

Voltage 230VAC
Introduction
AC INPUT Selectable Voltage Range 96~132VAC \ 155~280VAC (For personal computer)

PV3000 MPK series is a multi-function inverter ,combining functions of inverter and mppt solar charger controller, solar charger and battery charger to Frequency Range 50Hz/60Hz (Auto sensing) 40-80Hz
offer uninterruptible power support with portable size. The comprehensive LCD display offers user-configurable and easy-accessible button operation Minimum Start Voltage 10.5VDC \ 11VDC for 12VDC mode (*2 for 24VDC) 40.0VDC~42.0VDC
such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.
Low Battery Alarm 11VDC±0.3V for 12VDC mode (*2 for 24VDC) ±0.6V \ 42.0VDC±1.2V

Low Battery Cutoff 10.5VDC \ ±0.3V for 12VDC mode (*2 for 24VDC) ±0.6V \ 40.0VDC±1.2V
BATTERY
Back panel printing description Solar system connection High Voltage Alarm 16.0VDC \ ±0.3V for 12VDC mode (*2 for 24VDC) 32.0 VDC±0.6V \ 64.0VDC±1.2V

High Battery Voltage Recover 15.5VDC \ ±0.3V for 12VDC mode (*2 for 24VDC) 31.0 VDC±0.6V \ 62.0VDC±1.2V
11 10 9
Idie Consumption Search Mode <25W when power saver on <50W when power saver on

Solar Panel Output Voltage Depends on battery type

Charger AC Input Breaker Rating 10A 30A 30A 30A 40A


AC CHARGER
8 Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC) 31.4VDC/62.8VDC
1 Maximum Charge Current 35A 20A 45A 25A 65A 35A 75A 45A 35A 65A 35A 70A 40A 75A 50A
2
3
Input Voltage Waveform Sine wave (grid or generator)
7
4 Nominal Input Frequency 50Hz or 60Hz
5 6 BYPASS Overload Protection (SMPS Load) Circuit breaker
&
PROTECTION Output Short Circuit Protection Circuit breaker

12 13 14 15 16 20 21 AC Input Bypass Breaker Rating 10A 15A 30A 30A 40A

Max Bypass Current 30Amp 40Amp

Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 1250W 2500W 5000W 2500W 5000W 2500W 5000W 2500W 5000W
AC Output

Maximum PV Charge Current 80A 80A

DC Voltage 12V/24V auto work 24V/48V auto work


SOLAR
CHARGER MPPT Range @ Operating Voltage 16~100VDC @ 12V/32~145VDC @ 24V 32~145VDC @ 24V/64~145VDC @ 48V
Maximum PV Array Open
145VDC
19 18 17 22 23
Circuit Voltage
Battery
Maximum Efficiency >90% >98%

1. AC Charge 12. Remote port Standby Power Consumption <2W <2W


2. AC power on 13. BAT- Dimensions (W*H*D) 423*247*197 597*247*197
3. Inverter mode 14. BTS
Net Weight (Solar CHG) (kg) 18.5 18.4 19.5 19.4 23.5 32.2 28.7 27 \ 41.3 39.4 50.4 48.8 51.8 53.1
4. Fault 15. AGS MECHANICAL
5. Charge Current 16. RS232 communication port SPECIFICATIONS Shipping Dimensions (W*H*D) 570*355*300mm 597*247*197mm
6. Switch ON/OFF 17. BAT+ Shipping Weight (Solar CHG) (kg) 21.5 21.4 22.4 22.5 25.8 25.6 31.2 29.6 \ 44.7 42.8 54 52.4 55.7 53.1
7. LCD display 18. FAN
Operation Temoerature Range 0 ℃ to 40℃
8. Battery Type 19. Function Switch
9. Wiring fault 20. Charger input breaker Storage Temperature Range -15℃ to 60℃
OTHER
10. Batt fault 21. AC output breaker Audible Noise 60dB MAX
11. Power charging 22. PVAC IN/OUT
Loading (20GP/40GP/40HQ) 460pcs \ 920pcs \ 1060pcs 320pcs \ 640pcs \ 750pcs
23. AC Output 10A(MAX)

- 17 - - 18 -
Low Frequency Solar Inverter Solar Power System

PV3500 PRO Series (4KW-12KW)


Specification

PV35 PRO- PV35 PRO- PV35 PRO- PV35 PRO- PV35 PRO- PV35 PRO-
Features MODEL
4K 5K 6K 8K 10K 12K
• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc. Nominal Battery System Voltage 24V 48V 24V 48V 48V 48VDC 48VDC 48VDC
• Built-in MPPT solar charge controller 80A/100A/200A Rated power 4KW 5KW 6KW 8.0KW 10.0KW 12.0KW
• MPPT efficiency max 98% Surge rating(20ms) 12KW 15KW 18KW 24KW 30KW 36KW

• Powerful charge rate up to 140Amp Capable of starting electric motor 2HP 2HP 3HP 4HP 5HP 6HP

• DC start &Automatic Self-Diagnostic Function Waveform Pure sine wave \ same as input (bypass mode)

• WIFI / USB monitoring function with free CD (wi-fi optional) INVERTER Nominal output voltage RMS 220V \ 230V \ 240VAC (±10%RMS)
OUTPUT Output frequency 50Hz \ 60Hz ± 0.3Hz
• Supporting AGS, BTS port
Inverter effciency(peak) >85% >88%
• Compatible to generator
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
Voltage 230VAC
AC INPUT Selectable voltage range 90-280 VAC (APL)

Introduction Frequency range 50Hz \ 60Hz


Low battery voltage cutoff 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode)
PV3500 PRO series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to
offer uninterruptible power support with portable size. The comprehensive LCD display offers user-configurable and easy-accessible button operation Low battery voltage recover 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode)
such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications. BATTERY High battery voltage cutoff 30VDC for 24VDC mode (60VDC for 48VDC mode)
High battery voltage recover 28.5VDC for 24VDC mode (57VDC for 48VDC mode)
Idle consumption-search mode <30W when power saver on <60W when power saver on
Back panel printing description Solar system connection Output voltage Depends on battery type
Charger AC input breaker rating 40A 40A 50A 80A 80A 80A
AC CHARGER
Solar Panel Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current 80A 60A 100A 70A 80A 100A 120A 140A

8 BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature

Input voltage waveform Sine wave (grid or generator)


Generator
Nominal input frequency 50Hz or 60Hz
1 2 3 4 5 BYPASS Overload protection (SMPS Load) Circuit breaker
&
PROTECTION Output short circuit protection Circuit breaker
1. Switch ON/OFF 11. Remote control port Bypass breaker rating 40A 63A 63A 63A
2. LCD display 12. Fan AC Input
Max bypass current 40Amp 80Amp
3. AC/Inverter indicator 13. BTS
4. Charging indicator 14. AGS Maximum PV charge current 80A 100A(200A optional)
5. Fault indicator 15. AC input DC voltage 24V/48V Auto work 48V
6. BAT- 16. AC outputr AC Output
Maximim PV array power 2000W 4000W 2000W 4000W 4000W 5000W(10000W for 200A optional)
7. BAT+ 17. PV input
SOLAR
8. WIFI/USB communication port 18. Ground MPPT range @ operating voltage(VDC) 32-145VDC for 24V mode,64-147V for 48V mode 64~147VDC
CHARGER
9. AC input/Bypass breaker 19. PV2 input (optional) Maximum PV array open circuit voltage 147VDC
10. AC output breaker 20. PV1 input
Maximum effciency >98%
Standby power consumption <2W
Battery
Mounting Wall mount
Dimensions (W*H*D) 620*385*215mm 670*410*215mm
6 7 8 9 10 6 7 8 9 10 MECHANICAL
Net weight (solar CHG) (kg) 36 41 41 69+2.5 75.75+2.5 75.75+2.5
SPECIFICATIONS
Shipping dimensions (W*H*D) 755*515*455mm 884*618*443mm
Shipping weight (Solar CHG) (kg) 56 61 64 82.5+2.5 89+2.5 92+2.5
Operation temperature range 0°C to 40°C
Storage temperature -15°C to 60°C
OTHER Audible noise 60dB MAX

11 12 13 14 15 16 17 18 11 12 13 14 15 16 19 20 18 Display LED+LCD

[ 4KW-6KW ] [ 8KW-12KW ] Loading (20GP/40GP/40HQ) 140pcs \ 280pcs \ 320pcs

- 19 - - 20 -
Pure Sine wave High Frequency solar Inverter(450V) Solar Power System

PV1800 PRO Series (3KW, 5.2KW)


Specification

Features MODEL PV18-3024 PRO PV18-5248 PRO

• Pure sine wave output


Nominal Battery System Voltage 24VDC 48VDC
• Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
• Built-in MPPT solar charge controller Rated Power 3000VA / 3000W 5200VA /5200W
• MAX PV Array Open Circuit Voltage: 450V
Surge Power 6000W 10400W
• Can provide the power to the load without battery
• Combining solar system, AC utility, and battery power source to supply Waveform Pure sine wave
continuous power INVERTER OUTPUT
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
• Overload, short circuit and Deep discharge protection
• Cold start function Inverter Efficiency(Peak) 93%
• Support USB, RS485 monitoring function with free CD
Transfer Time 10ms (For personal computers) 20ms (For home appliance)
• WIFI remote monitoring (optional)

Voltage 230VAC±5%

AC INPUT Selectable Voltage Range 170~280VAC(For personal computer) \ 90~280VAC(For home appliances) \ 184~253VAC(VED4105)

Introduction Frequency Range 50Hz\60Hz(Auto sensing)

PV1800PRO is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power
Normal voltage 24VDC 48VDC
support in portable size. PV1800 PRO Series can run without battery. The Maximum PV array open circuit voltage can reach 450V and MPP voltage is
120~430Vdc, which Can help customers make full use of solar energy.
BATTERY Floating Charge Voltage 27.4VDC 54.8VDC

Overcharge Protection 30VDC 60VDC


Back panel printing description Solar system connection
Maximum PV Array Open Circuit Voltage 450VDC

Maximum PV current 18A


SOLAR PANELS

PV Array MPPT Voltage Range 150~450 VDC


1
...... SOLAR CHARGER
& AC
CHARGER Maximum Solar Charge Current 80Amp
2 3 LAPTOP
Maximum AC Charge Current 60Amp
4

5
LIGHTING Maximum Charge Current 80Amp

AC OUTPUT
Machine Dimensions (W*H*D)(mm) 272*355*100 295*528*121

PRINTER
6 7 8 9 10 11 12 Package Dimensions (W*H*D)(mm) 540*395*241 628*425*251
MECHANICAL
SPECIFICATIONS
Net Weight(kg) 11 14
INVERTER
TV
Gross Weight(kg) 12 15

AC INPUT
Humidity 5% to 95% Relative humidity (Non-condensing)
FANS

OTHER Operating Temperature -10℃ ~50℃


16 15 14 13
GENERATOR
BATTERY Storage Temperature -15℃ ~60℃

1. LCD Display 9. USB


2. Status Indicator 10. Dry Contact
3. Charging Indicator 11. PV Input
4. Fault Indicator 12. Power On/Off Switch
5. Function Buttons 13. Battery Input
6. AC Input 14. Parallel communication port
7. AC Output 15. Parallel switch
8. RS-485 Communication port 16. Circuit breaker

- 21 - - 22 -
High Frequency Solar Inverter Solar Power System

PV1800 VPK Series (1KW-5KW)


Specification

Features MODEL PV18-1012 VPK PV18-2024 VPK PV18-3024 VPK PV18-4048 VPK PV18-5048 VPK

• Pure sine wave output


Nominal Battery System Voltage 12VDC 24VDC 48VDC
• Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.)
• Built-in PWM 50A/60A solar charge controller Rated Power 1000W 2000W 3000W 4000W 5000W
• New SUB working mode(Solar-Utility-Battery working mode)
Surge Power 2000W 4000W 6000W 8000W 10000W
for 4K-5K series
• Combining solar system, AC utility, and battery power source to
Waveform Pure sine wave
supply continuous power INVERTER
OUTPUT
• Overload, short circuit and deep discharge protection AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
• Parallel operation with up to 3 units (Available for 4KW/5KW only)
Inverter Efficiency(Peak) 93%
• Cold start function
• Support USB, RS485 monitoring function with free CD Transfer Time 10ms (For personal computers) 20ms (For home appliance)
• WIFI remote monitoring (optional)
• Compatible to generator Voltage 230VAC

AC INPUT Selectable Voltage Range 170~280VAC(For personal computer) \ 90~280VAC(For home appliances) \ 184~253VAC(VED4105)

Introduction Frequency Range 50Hz \ 60Hz(Auto sensing)

PV1800 VPK is a multi-function inverter/charger, combining functions of inverter, PWM solar charger and battery charger to offer uninterruptible power Normal voltage 12VDC 24VDC 48VDC
support with portable size. Its comprehensive LCD display offers user-configurable easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different applications. BATTERY Floating Charge Voltage 13.5VDC 27VDC 54VDC

Overcharge Protection 15.5VDC 30VDC 60VDC

Back panel printing description Solar system connection Maximum PV Array Open Circuit Voltage 55VDC 70VDC 105VDC

Standby Power Consumption 2W 2W 2W


SOLAR PANELS
1. LCD Display SOLAR CHARGER
2. Status Indicator & (PWM)Maximum Solar Charge Current 50A 60A 60A
1 AC CHARGER
3. Charging Indicator
4. Fault Indicator Maximum AC Charge Current 10A or 20A 20A or 30A 60A
5. Funtion Buttons LAPTOP
2 3 Maximum ChargeCurrent 70A 80A 120A
6. AC Input
4 7. AC Output
5 8. RS-485 Communication port Machine Dimensions (W*H*D)(mm) 225*355*92 272*355*100 297.5*468*125
LIGHTING

Package Dimensions (W*H*D)(mm) 405*373*205 465*373*231 618*415*261


AC OUTPUT MECHANICAL
9. USB SPECIFICATIONS
PRINTER Net Weight(kg) 4.0 7.8 12
6 7 11 10. Dry Contact
11. PV Input
12. Power On/Off Switch Gross Weight(kg) 6.0 10.3 13.5
INVERTER
13. Battery Input TV
14. Parallel communication port Humidity 5% to 95% Relative humidity (Non-condensing)
15. Parallel switch
16. Circuit breaker AC INPUT OTHER Operating Temperature 0℃ ~55℃
FANS

Storage Temperature -15℃ ~60℃


16 8 9 10 13 12
GENERATOR
BATTERY
(3KW)

6 7 8 9 10 11 12

9 8
16
12
7

16 15 14 13 13 11

(4KW-5KW)(only for parallel model) (1-2KW)

- 23 - - 24 -
High Frequency Off Grid Solar Inverter Solar Power System

PV1800 VHM Series (2KW-5.5KW)


Specification

PV18-2024 PV18-3024 PV18-3048 PV18-4048 PV18-5048 PV18-5548


Features MODEL
VHM VHM VHM VHM VHM VHM
• Rated power : 2KW -5.5KW
Nominal Battery System Voltage 24VDC 48VDC
• Pure sine wave solar inverter
Rated Power 2000W 3000W 3000W 4000W 5000W 5500W
• Output power factor 1
Surge Power 4000W 6000W 6000W 8000W 10000W 11000W
• High PV input voltage range
Waveform Pure Sine Wave
• Built-in 80A MPPT solar charger INVERTER
OUTPUT
• Battery equalization function to optimize battery performance and AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%

extend lifecycle Inverter Efficiency(Peak) 93%

• Built-in anti-dusk kit for harsh environment


Transfer Time 10ms (For Personal Computers) 20ms (For Home Appliance)
• Support parallel operation up to 3 units (available for 3KW-5.5KW 48V)
Voltage 230VAC

AC INPUT Selectable Voltage Range 170~280VAC(For pensonal computer) \ 90~280VAC(For Home Appliance) \ 184~253VAC(VDE4105)

Introduction Frequency Range 50Hz/60Hz(Auto sensing)

PV1800 VHM is a multi-functional inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power Normal Voltage 24VDC 48VDC
support in portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different applications. BATTERY Floating Charge Voltage 27.4VDC 54.8VDC

Overcharge Protection 30VDC 60VDC

Back panel printing description Solar system connection Maximum PV Array Open Circuit Voltage 145VDC

1. LCD Display 10. Parallel communication prot PV Array MPPT Voltage Range 30~130VDC 64~130VDC
SOLAR PANELS
2. Status Indicator (only for parallel model)
3. Charging Indicator 11. Circuit breaker Standby Power Consumption 2W
4. Fault Indicator 12. AC input
5. Funtion Buttons 13. AC output SOLAR CHARGER PV Input Power 2000W 4000W
6. RS-485 Communication port 14. Fan LAPTOP &
7. USB 15. Battery input AC CHARGER Maximum Solar Charge Current 80A
8. Dry contact 16. Power on\off switch
9. Parallel switch 17. PV input Maximum Effciency 98%
LIGHTING

Maximum AC Charge Current 20A/30A 60A


AC OUTPUT

1
PRINTER Maximum Charge Current 80A 140A

2 Machine Dimensions(W*H*D)(mm) 272*355*100 297.5*468*125


3 INVERTER
TV
4 Package Dimensions(W*H*D)(mm) 540*395*241 638*395*241
5
MECHANICAL
SPECIFICATIONS
AC INPUT Net Weight(kg) 10 11 13.3
AIR CONDITIONING
6 7 8 Gross Weight(kg) 11.7 12 16.4

GENERATOR Humidity 5% to 95% Relatiy Humidity (Non-condensing)


BATTERY

OTHER Operating Temperature 0°C ~55°C

(2KW-3KW single model) Storage Temperature -15°C ~60°C

6 7 8 9 11 12 13 14 15 16 17 11 12 13 14 15 17 16
10

(2KW-5.5KW parallel model) (2KW-5.5KW single model) (2KW-5.5KW parallel model)

- 25 - - 26 -
Pure sine wave high frequency solar inverter with MPPT inside Solar Power System

PV1800 VPM Series (1-5KW)


Specification

PV18-1012 PV18-2024 PV18-3024 PV18-3048 PV18-4048 PV18-5048


Features MODEL
VPM VPM VPM VPM VPM VPM
• Rated power: 1-5KW
Default Battery System Voltage 12VDC 24VDC 48VDC
• Pure sine wave output
• Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc). Rated Power 1000VA \ 1000W 2000VA \ 2000W 3000VA \ 3000W 3000VA \ 3000W 4000VA \ 4000W 5000VA \ 5000W

• Bult in MPPT 60A/80A solar charge controller


Surge Power 2000VA 4000VA 6000VA 6000VA 8000VA 10000VA
• Combining solar system, AC utility, and battery power source to supply
continuous power Waveform Pure sine wave
INVERTER
• Overload, short circuit and Deep discharge protection OUTPUT
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)
• Cold start function
• Support USB, RS485 monitoring function with free CD Inverter Efficiency(Peak) 90%~93%
• WIFI remote monitoring (optional)
Transfer Time 10ms(For Personal Computers) \ 20ms(For Home Appliances)
• Compatible to generator
• Support parallel operation up to 3 units (available for 3KW-5KW 48V) Voltage 230VAC

AC INPUT Selectable Voltage Range 170~280VAC(For Personal Computers) \ 90~280VAC(For Home Appliances) \ 184~253VAC(VDE)

Introduction Frequency Range 50Hz \ 60Hz (Auto sensing)

This is a multi-function inverter/charger, combining functions of inverter, MPPT 60A/80A solar charger and battery charger to offer uninterruptible power Normal voltage 12VDC 24VDC 48VDC
support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging
current, AC/solar charger priority, and acceptable input voltage based on different applications. BATTERY Floating Charge Voltage 13.7VDC 27.4VDC 54.8VDC

Overcharge Protection 15VDC 30VDC 60VDC

Back panel printing description Solar system connection Maximum PV Array Open Circuit Voltage 55VDC 100VDC 145VDC

PV Array MPPT Voltage Range 15~55VDC 30~80VDC 64~130VDC


1. LCD Display
SOLAR PANELS
2. Status Indicator Standby Power Consumption 2W
1
3. Charging Indicator
SOLAR Maximum PV Array Power 625W 1250W 4000W
2 3 4. Fault Indicator
CHARGER
4
5. Funtion Buttons & AC
5 LAPTOP CHARGER" Maximum Solar Charge Current 60A 80A
6. AC Input
7. AC Output Maximum Efficiency 98%
(1KW)
8. RS-485 Communication port LIGHTING
9. USB Maximum AC Charge Current 10A or 20A 20A or 30A 60A
10. Dry Contact AC OUTPUT
Maximum Charge Current 80A 80A 140A
1 11. PV Input PRINTER

12. Power On/Off Switch Machine Dimensions (W*H*D)(mm) 225*355*92 272*355*100 297.5*468*125
2 3 13. Battery Input
4 INVERTER
14. Parallel communication port TV Package Dimensions (W*H*D)(mm) 410*300*78 485*393*251 638*395*241
5 MECHANICAL
(only for parallel model) SPECIFICATIONS
AC INPUT Net Weight(kg) 5 7.4 14
(2-5KW) 15. Parallel switch
FANS
16. Circuit breaker Gross Weight(kg) 5.5 9.5 16.4
9 8
GENERATOR Humidity 5% to 95% Relativ Humidity (Non-condensing)
BATTERY

OTHER Operating Temperature -10°C -55°C

6 7 8 9 10 11 12 Storage Temperature -15°C -60°C


12 6 7 12

16

13 11 16 13 11 16 15 14 13

(1KW) (2-3KW) (4-5KW)

- 27 - - 28 -
MPPT Solar Charge Controller Solar Power System

PC1800A Series (60A/80A)


Specification

Features MODEL PC18-6015A PC18-8015A

• LCD display , easy to operate on LCD screen


Nominal Battery System Voltage 12V\24V\48VDC (Auto detection); 36V (Setting)
• Multi stage charging
Maximum Battery Current 60Amps 80Amps
(3-stage charging , parallel charging and equalized charging function)
Battery Voltage
• BTS - Battery remote temperature sensor terminal
PV Array MPPT Voltage Range 15~95V 30~130V 45~130V 60~130V
• Enable to charge Li-thium, Gel , lead-acid battery

• With RS485 & USB communication port 12 Volt-940W 12 Volt-1250W


24 Volt-1880W 24 Volt-2500W
Maximum Input Power
• Protection: PV array short circuit, PV reverse polarity, Battery reverse 36 Volt-2820W 36 Volt-3750W
48 Volt-3760W 48 Volt-5000W
polarity, Over charging, Output short circuit ELECTRICAL
SPECIFICATIONS

Solar high voltage disconnect


Solar high voltage reconnect
Battery high voltage disconnect
Introduction Protections
Battery high voltage reconnect
High temperature disconnect
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and High temperature reconnect
assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.

Charging Algorithm 3-Step or 4-Step (Li)

Back panel printing description Solar system connection Temperature Compenssation Coefficient -5mV \ ℃ / cell (25℃ ref.)

Temperature Compenssation Set Points Absorption, Float

1. LCD display Charging Set Points Absorption Stage Float Stage


MPPT SOLAR CHAGE
CONTROLLER BATTERY
2. Power ON/Charging indicator Flooded Battery 14.2V \ 28.4V \ 42.6V \ 56.8V 13.7V \ 27.4V \ 41.1V \ 54.8V
CHARGING
1 SOLAR PANELS
3. Fault and warning indicator AGM / GEL / LEAD Battery (Default) 14.4V \ 28.8V \ 43.2V \ 57.6V 13.7V \ 27.4V \ 41.1V \ 54.8V
2
3
Over-charging Voltage 15.5V \ 30.0V \ 45.0V \ 60.0V
4
4. Wiring fault indicator
Over-charging Comeback Voltage 14.5V \ 29.5V \ 44.5V \ 59.0V
5 5. Operation button
Battery Defect Voltage 10.0V \ 17.0V \ 25.5V \ 34.0V
6. PV connextors
BATTERY
Product Size (W*H*D)(mm) 315*160*135
7. Battery connectors
Product Weight (kg) 4.7kg
8. Battery temperature sensor terminal
AC INPUT MECHANICAL Ambient Temperature Range -10℃ to 55℃
9. Wiring box cover AND
ENVIRONMENT Storage Temperature -40℃ to 75℃
10. RS485 communication port
Humidity 0%~90% RH (No condensing)
AC OUTPUT
11. USB
Enclosure IP20
INVERTER

9 6 7

LAPTOP LIGHTING AIR-CONDITIONER TV FANS

10 11 8

- 29 - - 30 -
MPPT Solar Charge Controller Solar Power System

PC1800F Series (60A/80A/100A)


Specification

Features MODEL PC18-6015F PC18-8015F PC18-10015F

• LCD display , easy to operate on LCD screen


Nominal Battery System Voltage 12V\24V\48VDC (Auto detection); 36V (Setting)
• Multi stage charging (3-stage charging , parallel charging and
Battery Voltage 12V 24V 36V 48V 48V
equalized charging function)
Maximum Solar Input Voltage 100V 145V
• BTS - Battery remote temperature sensor terminal
PV Array MPPT Voltage Range 15~95V 30~130V 45~130V 60~130V 60~130V
CONTROLLER
• Enable to charge Li-thium, Gel , lead-acid battery INPUT
12 Volt-940W 12 Volt-1250W 12 Volt-1560W
• With RS485 & USB communication port 24 Volt-1880W 24 Volt-2500W 24 Volt-3120W
Maximum Input Power
36 Volt-2820W 36 Volt-3750W 36 Volt-4680W
• Protection: PV array short circuit, PV reverse polarity, Battery reverse 48 Volt-3760W 48 Volt-5000W 48 Volt-6250W

polarity, Over charging, Output short circuit


Charging Set Points Absorption Stage Float Stage

Flooded Battery 14.2V \ 28.4V \ 42.6V \ 56.8V 13.7V \ 27.4V \ 41.1V \ 54.8V

AGM (Default) 14.4V \ 28.8V \ 43.2V \ 57.6V 13.7V \ 27.4V \ 41.1V \ 54.8V

Over-charging Voltage 15.5V \ 30.0V \ 45.0V \ 60.0V


Introduction
Over-charging Comeback Voltage 14.5V \ 29.5V \ 44.5V \ 59.0V
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and
assures peak performance from a solar array. Each Charge Controller allows customized battery recharging. BATTERY Battery Defect Voltage 10.0V \ 17.0V \ 25.5V \ 34.0V

Temperature Compensation
-5mv \ ℃ \cell (25℃ vef)
Conefficient

Back panel printing description Solar system connection Peak Conversion Efficiency 98% (MPPT Efficiency 99%)

Mximum Battery Current 60Amps 80Amps 100Amps


1. LCD display 100amps continuous @ 40℃
Max Charging Current 60amps continuous @ 40℃ ambient 80amps continuous @ 40℃ ambient
1 MPPT SOLAR CHAGE ambient
15
2. Power ON/Charging indicator CONTROLLER
16 3. Fault and warning indicator GENERAL
Radiating Mode Fan cooling
SPECIFICATION
3 SOLAR PANELS
4. Wiring fault indicator
5
5. Operation button
Solar high voltage disconnect
6. PV connectors DISPLAY
Solar high voltage reconnect
Battery high voltage disconnect
7. Battery connectors & Protections
12
Battery high voltage reconnect
PROTECTION
8. Battery temperature sensor terminal High temperature disconnect
High temperature reconnect
9. Wiring box cover BATTERY

10. RS485 communication port Mounting Wall mount


11. USB
AC INPUT Machine Dimension (W*H*D) 152*85*294 mm (per pcs) 175*82.9*257.1
12. FAN
MECHANICAL
G.W (kg) 3kg/pcs
13. Load connectors SPECIFICATIONS
13 7 6 14 8 14. Communication network terminal AC OUTPUT Package Dimension (W*H*D) 625*366*232 mm (4pcs / Carton) /

(100A) 15. PV indicator Gross Weight (kg) 14kg


INVERTER
16. Battery indicator
Environmental Rating Indoor
1
Operation Temperature Range -10~55℃
2
OTHER
3
Ambient Humidity 0~90% relative humidity (non-condensing)
4
5 LAPTOP LIGHTING AIR-CONDITIONER TV FANS Altiude ≤3000m

10 11 8 9 6 7
(60A/80A)

- 31 - - 32 -
MPPT Solar Charge Controller Solar Power System

PC1600A Series (20/30/40A)


Specification

Features MODEL PC16-2015A PC16-3015A PC16-4015A

• LCD display , easy to operate on LCD screen


Nominal Battery System Voltage 12VDC/24VDC (Auto Detection)
• Multi stage charging
PV Open Circuit Voltage 100VDC@12V/145VDC @24V
(3-stage charging , parallel charging and equalized charging function)
PV Array MPPT Voltage Range 16VDC~100VDC / 32VDC~130VDC
• BTS - Battery remote temperature sensor terminal CONTROLLER
INPUT
Max PV Input Power(12V) 300W 450W 600W
• Enable to charge Li-thium, Gel , lead-acid battery

• With RS485 communication port Max PV Input Power(24V) 600W 900W 1200W

• Protection: PV array short circuit, PV reverse polarity, Battery reverse Absorption Voltage 12.5VDC / 25.0VDC

polarity, Over charging, Output short circuit


Refloat Voltage 13.7VDC / 27.4VDC
BATTERY
Float Voltage 14.3VDC / 28.6VDC

Low Voltage Protection Point 10.0VDC / 20.0VDC

Introduction Output Voltage 10.0~14.5VDC / 20.0~29.0VDC

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and Peak Conversion Efficiency 98%(MPPT Efficiency 99%)
assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.
Max Charging Current 20 amps continuous 30 amps continuous 40 amps continuous

DC OUTPUT Max Output Current 20 amps continuous 20 amps continuous 20 amps continuous

Back panel printing description Solar system connection Low Voltage alarm 10.25VDC / 20.5VDC

Low Voltage cut off 10.0VDC / 20.0 VDC


MPPT SOLAR CHAGE
CONTROLLER Low Voltage Recovery 11.0VDC / 22.0VDC
14 13 7 8 9 10 11 12
GENERAL
SOLAR PANELS Radiating Mode Automatic cooling
SPRCIFICATION

Systematic operation, LV indication, LV protection, Over charge protection


1 LED Indication
Loads protection, Short circuit protection

2
LED Display Charge Voltage, Charge Current, Voltage of storage battery, Capacity of storage battery, Output current

6 3 DISPLAY
PV array short circuit, PV reverse polarity
BATTERY &
5 4
PROTECTION
Battery reverse polarity, Over charging protrction
Alarm Protections
AC INPUT
1. LCD Display Output short circuit protection

2. LED Indicator
Low voltage protection for storage battery
3. Confirm the selection in setting mode
AC OUTPUT
Mounting Wall mount
4. Decrease the setting data
INVERTER
5. Increase the setting data Machine Dimension(W*H*D) 154*236*88mm (color box / pcs)
6. Enter or exit setting mode MECHANICAL
Gross Wight (kg)(per pcs) 2.5kg
7. The load negative terminal SPECIFICATIONS

8. The load positive terminal Package Dimension (W*H*D) 610*308*230mm (4PCS/Carton)

9. The battery negative terminal LAPTOP LIGHTING AIR-CONDITIONER TV FANS Gross Weight (kg)(per carton) 10.8kg 13.4kg 13.4kg
10. The battery positive terminal
11. PV array negative terminal Environmental Rating Indoor

12. PV array positive terminal OTHER Operation Temperature Range -25℃ ~ +55℃
13. Communication network terminal
Loading (20GP/40GP/40HQ) 2500pcs / 5000pcs / 5800pcs
14. Remote external temerature terminal

- 33 - - 34 -
Low Frequency Pure Sine Wave Inverter Solar Power System

EP3000 Series (8KW/10KW/12KW)


Specification

Features MODEL EP30-8KW EP30-10KW EP30-12KW

• Rated power 8KW to 12KW Nominal Battery System Voltage 48VDC 48VDC 48VDC

• Pure sine wave output Continuous output power 8.0KW 10.0KW 12.0KW

Surge rating (20ms) 24.0KW 30.0KW 36.0KW


• Max 100A automatic 3-stage battery charger
Capable Of Starting Electric Motor 4HP 5HP 6HP
• Charger current is Adjustable (0-100%)
Output waveform Pure sine wave \ same as input (bypass mode)
• Automatically send signal to start generator
Inverter Efficiency(Peak) >88%
• DC start & automatic self-diagnostic function INVERTER
Line mode efficiency >95%
OUTPUT
• Supporting USB/RS485 communication and BTS & AGS port Power factor 1.0

• Battery/AC priority Nominal output voltage RMS 220V \ 230V \ 240VAC(±10% RMS)

Output frequency 50Hz

Short circuit protection Yes (1sec after fault)

Typical transfer time 10ms(max)

Voltage 155-272VAC
Introduction
AC INPUT Selectable Voltage Range 155~272VAC(For Personal Computers)
Low frequency pure sine wave combined inverter&A/C charger EP3000 Series 8 -12kw; Quiet,high efficiency operation front panel LED+LCD indicators Frequency Range 50HZ/60HZ
and adjustable switch selectors selectable settings for flooded lead acid,Gel,or absorbed glass mat(AGM) batteries. Mainly for home and office
Minimum start voltage 40.0V±0.6 \ 42.0V±0.6
applicances such as TV, refrigerator, fans lights and computers etc.
Low battery alarm 41.5V±0.6 \ 43.5V±0.6

Low battery Cutoff 40.0V±0.6 \ 42.0V±0.6


BATTERY
Back panel printing description Solar system connection High voltage alarm 62V±0.6

High battery voltage recover 54V±0.6


SOLAR PANELS
MPPT SOLAR CHARGE Idle consumption-search mode <35W when power saver on
1 2 4 8 6
CONTROLLER
Output voltage Depends on battery type

Charger AC input breaker rating 80A

CHARGER Max charge power rate 1/3 Rating power

Overcharge protection S.D. 62.8VDC

Maximum Charge Current 70A 80A 100A


3 5 7
BTS Temperature rate @25°C 4mv charging voltage descent, per 1℃ rise
LAPTOP
Input voltage waveform Sine wave (grid or generator)
BATTERY
9 10 11 12 13 14 Nominal voltage 220V \ 230V \ 240VAC
LIGHTING Max input AC voltage 300VAC for 230VAC HV mode
BYPASS Nominal input frequency 50Hz or 60Hz
&
AC OUTPUT PROTECTION Overload protection (SMPS load) Circuit breaker
PRINTER
Output short circuit protection Circuit breaker
AC INPUT
Bypass breaker rating 63A

Max bypass current 63Amp


TV
INVERTER Mounting Wall mount

15 16 17 18 19 20 21
Inverter dimensions (W*H*D) 670*410*215mm
GENERATOR
AIR CONDITIONING MECHANICAL
Inverter weight (solar chg) KG 67.5 74 74
SPECIFICATIONS
Shipping dimensions(W*H*D) 802*533*429.5mm
1. Power saver on/off switch 8. LCD display 15. Funtion switch(SW1-SW5)
Shipping weight (solar chg) KG 87 93.5 93.5
2. AC Charger current setting 9. Remote panel 16. FAN
Operation Temperature Range 0℃ to 40℃
3. Battery Voltage Setting 10. BAT- 17. BTS
Storage Temperature -15℃ to 60℃
4. Inverter indicator 11. BAT+ 18. AGS
OTHER Audible Noise 60bB MAX
5. Grid indicator 12. RS485/USB Communication port 19. AC input
Display LED+LCD
6. Fault indicator 13. AC input bypass breaker 20. AC output
Loading(20GP/40GP/40HQ) 200pcs \ 400pcs \ 500pcs
7. Function 14. AC output bypass breakerr 21. Ground

- 35 - - 36 -
Low Frequency Pure Sine Wave Split Phase Inverter Charger Solar Power System

EP3300 TLV Series (1KW-6KW)


Specification

EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33-
Features
MODEL 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
• Pure sine wave output, split phase HOT1+ N + HOT2 available, TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV

120VAC/220VAC Rated power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW

• MFD (multi-function display) & Friendly user interface Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA

• 3 Steps optimizing charge for battery pack Capable of starting electric motor 1P 1P 1.5P 1.5P 2P 3P

• Overload and short-circuit protection Power factor 1

• Settable: charging/charging current, utility/Battery priority, Wave form Pure sine wave / Same as input wave form (bypass mode)

utility input wide/narrow range Output voltage RMS 100V \ 110V \ 120VAC (200V \ 220V \ 240VAC) ±10%
Inverter
• Inverter voltage can be set to 100V/110V/120V Output
Output frequency 50Hz or 60Hz (±0.3Hz) (can be set)

• Inverter frequency can be set to 50/60Hz Overload protection Breraker + software protection

Output short circuit Breraker + software protection

Inverter efficiency (peak) >80%


Introduction
100% < Load < 110% (alarm 5min then stop output and fault code 07)
This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
matches AC 110VAC/120V single phase, or two phase 110VAC/120V 120V/240V; In LCD display, you can set output voltage, frequency, charging Load > 125% (alarm 10s then stop output and fault code 07)
voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charger controller to
build a solar home system, take use of sunshine freely and save electricity bills.
Battery voltage 12VDC \ 24VDC 24VDC \ 48VDC 48VDC

Back panel printing description Solar system connection Minimum start voltage 11VDC \ 22VDC \ 44VDC

(Low voltage fault code04)


Low battery voltage cut off
1 10 \ 10.5 \ 11V for 12V mode (*2 for 24VDC \ *4 for 48VDC)

AC INPUT Battery
Add 0.5V \ battery:(Low battery alarm one second one time)
Low battery voltage alarm
(10 \ 10.5 \ 11V)+0.5VDC for 12V mode (*2 for 24VDC \ *4 for 48VDC)

3 LAPTOP
Add 1V \ battery:(High battery one second one time \ after 30s fault 03)
2 4 High battery voltage alarm
GENERATOR
(13.8-14.5V)+1V for 12V mode (*2 for 24VDC \ *4 for 48VDC)
5 8 13
LIGHTING
6 7 Save mode Loads ≤ 40W (110V) \ 80W (220V)
9 AC OUTPUT
Input waveform Pure sine wave
10 11 12 14 AIR CONDITIONING
Nominal input voltage 200Vac \ 220Vac \ 240Vac
INVERTER
Max input voltage 270Vac MAX
16 17 18 19 20 21 TV
MPPT SOLAR CHARGE AC Input
CONTROLLER Input frequency 50Hz \ 60Hz (auto sensing)
Mode

FANS Efficiency (AC mode) >95% (load, full battery)

BATTERY Transfer time AC to DC 15ms(max)


SOLAR PANELS
Transfer time DC to AC 15ms(max)

Boost voltage 14.1V(Default) Range of adjustment 13.8-14.5V \ *2 for 24VDC \ *4 for 48VDC (Regulation step 0.1V)

Float voltage 13.5V(Default) Range of adjustment 13.5-13.7V \ *2 for 24VDC \ *4 for 48VDC (Regulation step 0.1V)
15

12V 30A 45A 60A \ \ \ \


Charge
Mode
24V 20A 25A 30A 40A 60A \ \
1. LCD Setting 8. Enter and confirm 15. Battery -/+
48V \ \ \ 20A 30A 35A 40A
2. AC Status LED 9. Switch on / off 16. BTS
3. Inverter Status LED 10. AC OUTPUT1: HOT1 - N 100VAC/110VAC/120VAC 17. AGS Min charge current 10A. Change by every 5A

4. Fault Warning LED 11. AC OUTPUT2: HOT2 - N 100VAC/110VAC/120VAC 18. USB Dimensions (W*H*D) 277*196*466mm 277*186*621mm
5. MENU 12. AC INPUT: HOT1 - HOT2 200VAC/220VAC/240VAC 19. Remote Panel
Dimensions Ship Dimensions (W*H*D) 376*306*592mm 376*296*747
6. Page up 13. AC OUTPUT: HOT1 - HOT2 200VAC/220VAC/240VAC 20. Fan
Warranty One year (standard), 2 years optional (IP20)
7. Page down 14. 5.15AMAX JFCI Output 100V/110V/120V Socket, 15A MAX 21. AC input breaker

- 37 - - 38 -
Low Frequency Power Inverter/Charger Solar Power System

EP3000 Pro Series (1KW-6KW)


Specification

EP30-
Features EP30-1KW EP30-2KW EP30-3KW EP30-4KW EP30-5KW EP30-6KW
MODEL 1.5KW
PRO PRO PRO PRO PRO PRO
• LCD display ,easy to read how inverter operates on LCD screen PRO

• Compatible to generator Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 48VDC 24VDC 48VDC 24VDC 48VDC 24VDC 48VDC

• 5 -levels DIP switch ,offering customized performance Rated Power 1.0KW 1.5KW 2KW 3KW 4KW 5KW 6KW

• 9 - levels battery selector ,Enable to charge Gel , lead-acid battery Surge Rating(20ms) 3.0KW 4.5KW 6.0KW 9.0KW 12KW 15KVA 18KW

• DC(Solar)/AC prority optional Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 3HP
• 4 levels charge current adjustable Waveform Pure sine wave \ same as input (bypass mode)
• With RS232 communication port
Nominal Output Voltage RMS 100V \110V \ 120V \ 220V \ 230V \ 240VAC (±10% RMS) 220V \ 230V \ 240VAC (±10% RMS)
INVERTER
• With BTS & AGS , optimazing battery performance & start generator OUTPUT
Output Frequency 50Hz \ 60Hz ±0.3Hz
automatically
Inverter Efficiency (Peak) >88%
• Power saver Switch , Enable to minimize standby consumption
Line Mode Efficiency >95%

Power Factor 1.0

Typical Transfer Time 10ms(max)


Introduction
Voltage 230VAC
EP3000 PRO series is very economical pure sine wave inverter, AC charger inbuilt, from 35A to 70A; Solar/AC priority is configurable, when setting solar AC
Selectable Voltage Range 96~132VAC 155~280VAC(For personal computers)
priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current too lower, in this way system charge is INPUT
optimazed best. With pure copper transformer, it enables inverter to operate with all kinds of home appliances. Frequency Range 50Hz \ 60Hz(Auto sensing) 40~80Hz

Minimum Start Voltage 10.5VDC \ 11VDC for 12VDC mode(*2 for 24VDC, *4 for 48VDC)

Low Battery Alarm 11VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
Back panel printing description Solar system connection
Low Battery Cut Off 10.5VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
BATTERY
1 3 4 7 High Voltage Alarm 16.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)

1. Switch On\Off MPPT SOLAR CHARGE


SOLAR PANELS High Battery Voltage Recover 15.5VDC ±0.3V for 12VDC mode
CONTROLLER
2. Charge current adjustable Idie Consumption-Search Mode <25W when power saver on
3. AC Charge Indicator
Output Voltage Depends on battery type
4. AC power Indicator
Charge AC Input Breaker Rating 10A 30A 30A 30A 40A
5. Inverter Indicator CHARGER
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
6. Fault Indicator
2 6 5
Maximum Charge Current 35A 20A 45A 25A 65A 35A 75A 45A 30A 65A 35A 70A 40A 75A 50A
AC INPUT
12
Input Voltage Waveform Sine wave (grid or generator)
BATTERY
7. Battery type selector Nominal Input Frequency 50Hz or 60Hz
8. Charger Input Protection GENERATOR BYPASS Overload Protection (SMPS Load) Circuit breaker
9. Inverter Output Protection &
PROTECTION Output Short Circuit Protection Circuit breaker
10. AC I/O Connection INVERTER/CHARGER AC OUTPUT
Bypass Breaker Rating 10A 30A 30A 30A 30A 40A
11. AC Output 10A MAX
Max Bypass Current 30Amp
12. Battery input
Mounting Wall Mount

13 14 15 16 17 18 Dimensions (W*H*D) 426*206*178mm 601*206*178mm


13. Remote control LAPTOP LIGHTING AIR CONDITIONING TV FANS
MECHANICAL
Net Weight (Solar CHG)(kg) 16.5 17 21.1 20 26 24.5 24.8 38.2 35.8 45.2 45 45.2 45
8 9 14. DIP Switch (SW1-SW5) SPECIFICATIONS

15. Fan Shipping Dimensions (W*H*D) 5570*335*300mm 750*335*300mm

16. RS232 communication port Shipping Weight (Solar CHG)(kg) 19.3 20 24.1 22.8 29.1 27.5 27.5 42.3 40 49.5 49.3 49.5 49.3

17. BTS Operation Temperature Range 0℃ to 40℃

18. AGS Storage Temperature -15℃ to 60℃

OTHER Audible Noise 60dB MAX

Display LED+LCD

10 11
Standard Warranty 1 year, 2 or 3 years optional (IP20)

- 39 - - 40 -
Low Frequency Power Inverter/Charger Solar Power System

EP2000 Pro Series


Specification

EP20-0312 EP20-0612 EP20-0812 EP20-1012 EP20-0324 EP20-0624 EP20-0824 EP20-1024 EP20-2148


Features MODEL
PRO PRO PRO PRO PRO PRO PRO PRO PRO
• Rated power 300W to 2100W Default Battery System Voltage 12VDC 24VDC 48VDC
• Pure sine wave output Rated Power 400W 500W 800W 1000W 300W 600W 800W 1000W 2100W

• Smart LCD setting ( frequency , charge voltage,charge current, etc). Surge Rating (20ms) 1200W 1500W 2400W 3000W 900W 1800W 2400W 3000W 6300W
Waveform Pure sine wave
• 3 steps charging algorithm
INVERTER Rated Output Voltage Inverter: 230VAC (±2% RMS), AVR: 195VAC-245VAC
• Built in AVR function OUTPUT Output Frequency 50Hz \ 60Hz ±0.2Hz
• Overload and short-circuit protection Invertert Frequency (Peak) >75% >81% >83%
Bypass Efficiency >95%
• Battery reverse polarity protection (Optional)
Output Transfer Time Typical:6ms 10ms(max)
• Deep discharge protection
Voltage 220 \ 230 \ 240VAC
• Cold start function Selectable Voltage Range 140~280VAC±2%
Low Battery Alarm 140VAC±2%
Low Voltage Recover 150VAC±2%
High Battery Alarm 280VAC±2%
High Voltage Recover 270VAC±2%
AC INPUT
Introduction Low Frequency Alarm 45±2Hz
Low Frequency Recover 46±2Hz
EP2000 PRO series inverter is a cost effective, intelligent with UPS function. The comprehensive LCD offers user-configurable and easy-accessible High Frequency Alarm 65±2Hz
button adjustment such as battery charge current, battery charge voltage, frequency, buzzer etc. It's perfect for the user who need a simple and
High Frequncy Recover 64±2Hz
economical inverter,with user-friendly installnation and setting.Tower and rack design available for different choices.
Nominal Input Range 50Hz \ 60Hz ±2Hz
AC Auto Restart YES
Minimum Start Voltage Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+0.5V
Back panel printing description Solar system connection
Low Battery Alarm Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+1.0V
BATTERY
Low Battery Cutoff 10-12.0VDC 20.0-24.0VDC 42-44VDC
1 2 6 9 17 MPPT SOLAR CHAGE High Battery Cutoff Nominal Voltage +0.5V Nominal Voltage +1.0V
CONTROLLER
Floating Voltage 13.5-14.5VDC 27-29VDC 54-58VDC
AC Nominal Voltage 13.8~14.5V 27.6~29V 55.2-58VDC
CHARGE 400W 500W 800W 1000W 300W 600W 800W 1000W 3000W
Maximum Charge Current
10A 15A 25A 30A 5A 10A 15A 15A 18A
Input Waveform Pure sine wave
18 5 8 10 7 13 14 15 16 Input Frequency 50Hz or 60Hz
Overload Protection 110%~125%R Load foult affter 30S ; 125%~150%R Load foult affter 3S ; >150%R Load fault after 500ms
EP2000 PRO (Rack) BATTERY
SOLAR PANELS Over Temperature Protection ≥90℃

BYPASS Bypass Output Protection 10A 250VAC


& Output Circuit Protection YES
PROTECTION
Battery Reverse Protection Optional
1 3 11
Battery Low Voltage Protection YES
4 15 AC INPUT
2 12 Battery High Voltage Protection YES
5 16
6 Bypass Breaker Rating 10A
7 8
Maximum Bypass Current 10A
9 18
13 17 INVERTER/CHARGER GENERATOR Dimensions 315*145*210mm 375*192*340mm
10
AC OUTPUT 300W 600W 800W 1000W 1000W
14 (N.W)kg
MECHANICAL 7.5 10.7 12.5 13.5 14.5
SPECIFICATION Shipping Dimensions(W*H*D) 420*280*225mm 525*335*485mm

EP2000 PRO (Tower) 300W 600W 800W 1000W 3000W


(G.W)kg
8 11.5 13 14.0 15.5
LAPTOP LIGHTING PRINTER TV FANS Operating Temperature 0℃ ~40℃ 0~90% relative humidity (non-condensing)
Storage Temperature -15℃ to 55℃
1. LCD display 7. SEL 13. AC Input
Altitude ≤1000M
2. AC Input LED 8. ENTER 14. Battery input
Audible Noise ≤60dB
3. Bypass LED 9. Power On 15. RS232 OTHER
Display LED+LCD
4. AC output LED 10. Power Off 16. Fan Cooling Mode Fan cooling
5. Fault LED 11. Fax / Tel 17. AC output Fan Starting >45℃ starting, <30℃ Closing

6. ESC 12. USB 18. Battery LED Communication RS232 / USB

- 41 - - 42 -
High Frequency Power Inverter/Charger Solar Power System

EP1100 Pro Series (1200VA 2400VA)


Specification

Features MODEL EP11-1200 PRO EP11-2400 PRO

• Rated power 1.2KVA to 2.4KVA Nominal Battery System Voltage 12VDC 24VDC
• Modified sine wave inverter
Rated Power 1200VA/720W 2400VA/1440W
• Double layers PCB board.
• Configurable input voltage ranges(90-280VAC/170-280VAC) Waveform Modifided Sine Wave

via LCD setting Nominal Output Voltage RMS 220V \ 230V \ 240V
• Display accumulated working time
Output Voltage Regulation +10/-18%
• 3 steps charging algorithm
INVERTER
• Auto restart while AC recovery Output Frequency 50Hz \ 60Hz±0.5Hz
OUTPUT
• Overload & short-circuit protection, Battery reverse polarity protection, Inverter Efficiency (Peak) >80%
Deep discharge protection
Line Mode Efficiency >95%
• Advanced technology optimizes battery life
Power Factor 0.6
• Automatic line-to-battery switchover
Typical Transfer Time Typical 15~20ms 40ms max

Voltage 220 \ 230 \ 240VAC


Introduction
Narrow 170~280VAC
AC
EP1100 Pro 1200VA/2400VA is a modified sine wave inverter applied to TV, stereos, laptops, and desktop computers and other home appliances. It INPUT
Selectable Voltage Range
Wide 90~280VAC
will automatically switch to inverter and provide power when AC is interrupted unexpectedly.It's perfect for the user who need a simple and economical
inverter,with user-friendly installnation and setting. Frequency Range 50Hz \ 60Hz(Auto sensing)

Nominal Input Voltage 12VDC 24VDC

Back panel printing description Solar system connection Minimum Start Voltage 10.5VDC 21.0VDC

Low Battery Alarm 10.5VDC±0.3V 21.0VDC±0.3V


BATTERY
MPPT SOLAR CHARGE
CONTROLLER
Low Battery Cutoff 10.0VDC±0.3V 20.0VDC±0.3V

High Voltage Alarm 16.0VDC±0.3V 32.0VDC±0.3V

2 High Battery Voltage Recover 15.0VDC±0.3V 30.0VDC±0.3V


1 3
Charger Voltage (Vbat<12.5V) 14.4VDC±0.4V 28.8VDC±0.4V

4 Charger Voltage (Vbat>12.5V) 13.7VDC±0.2V 27.4VDC±0.2V


6
BATTERY CHARGER Charging Current 10A 10A±2A
5 7
SOLAR PANELS
8 Charging Current 20A 20A±2A

Overcharge Pretection S.D. 16VDC±0.4A 32VDC±0.8A

Nominal Input Frequency FUSE


AC INPUT
Overload Protection (SMPS Load) FUSE
BYPASS
& Output Short Circuit Protection 10A
PROTECTION
GENERATOR Bypass Fuse Rating 10Amp
INVERTER/CHARGER
AC OUTPUT
Max Bypass Current 246*253*87mm

Dimensions (W*H*D) 246*253*87mm

Net Weight (kg) 2.3kg


MECHANICAL
SPECIFICATIONS
LAPTOP LIGHTING PRINTER TV FANS Shipping Dimensions (W*H*D) 315*368*145mm
9 10 11 12
Shipping Weight (kg) 2.9 3.1

Operation Temperature Range 0℃ to 40℃

1. Fault LED 5. Set Key 9. AC Input Audible Noise 60dB MAX


2. Inverter Mode LED 6. Flip Key 10. OutoutReceptacle(s) OTHER
Display LED+LCD
3. Line Mode LED 7. Enter Key 11. Fan
Standard Warranty 1 year
4. LCD Display 8. ON / OFF 12. DC Input Connecctor(Battery Terminal)

- 43 - - 44 -
High Frequency Online UPS (Single Phase Input Single Phase Output) Solar Power System

EH5000 Series (6KVA-10KVA)


Specification

Type H6K H6KS H10K H10KS


Features
Capacity VA/W 6KVA \ 4.8KW 10KVA \ 8KW
• Rated power 6KVA to 10KVA Input wire Single phase two wire + ground wire

• Pure sine wave output Voltage range AC 120V-275V


Frequency Range 50/60HZ Auto sensing
• Double conversion online design, zero output transfer time Input
Distortion <5%
• IGBT technology Power factor ≥0.99
Generator input support
• N+X parallel redundancy
Voltage range AC 220×(1+1%)V
• LCD+LED Display
Frequency (same Frequency mode) 46-54Hz \ 56-64Hz Synchronized with the input (utility frequency)

• Cold start function Frequency (battery mode) 50(1+1%) \ 60(1+1%)Hz


Power factor 0.8
• Support RS232 monitoring function with free CD
Crest ratio 3:1
Output ≤ 3%THD( Linear load)
Harmonic distortion
≤ 6%THD( Nonlinear load)

Introduction Output waveform Pure sine wave


Output method Terminal block
The EH5000 series is high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and
system reliability. small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, utility high voltage, utility Overload capability
Utility: 105%-125%,1min;125%-135%,30S;>135%,0.5S
low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency Battery: ≥ 105% for 30 S
fluctuation, Provide best power environment for load. Charging mode 90%
Efficiency Battery mode 90%
Back panel printing description Utility priority mode 97%
Type of battery 12V\7AH 12V\7AH

 \  \
1. Computer Interface Number of batteries 16 16
9 9 9 9
2 2 2 2
1 1 1 1 2. Intelligent Slot Equipment time (full load) >5min >5min
4 4
4 4 3. Fan Battery Charging time (90%) 8Hours 8Hours
3
3 3
4. Parallel Cover(Optional) Rechargeable battery (maximum) 1.0A 5.0A 1.0A 5.0A
6 3 6
Rated charging voltage 218.4VDC
5. Input Switch
5 6 5 6 Temperature text support
6. Maintain Switch Cover(Optional)
5 5 Utility to battery 0ms
7 7 7. Terminal Cover Transfer time
Inverter to bypass 4ms
8 8
7 7
8. Cable fix frame
8 8
Mains priority mode support
9. EPO(Optional)
Other Normal mode
(6K) (10K) (6KS) (10KS) support
characteristics (constant voltage constant frequency)
Parallel redundancy 3 sets (maximum)
LED display Load Status / Battery Capacity / Battery Mode / Bypass Mode / Fault
Indicator ligh
LCD Display Information LCD display Load / Battery / Input / Output / Operating Mode
Battery mode beep every 4 seconds
1. Inverter Output Low electricity beep every second
1
Beep sound
4
5 2. Standby overload beep 2 every second
2 5 1
3. Fault malfunction continuous beep
6
6
2 Dimension(D*W*H) mm 248x500x616 240x500x460 248x500x616 240x500x460
3 4. LCD Screen
7 Shape
4 3 7
8 5. On/mute Net weight (Kg) 57 18 67.5 20

(LCD Panel) 6. Select Operating environment 0~40℃


(Button Operation) Use
7. Off/enter environment
Humidity 20~90%( Non-condensing)
1. Parameters 5. Parameters type
Noise level <55dB@1Meter
2. Bypass indicator 6. Load information
Micro RS-232 Support Windows 2000/2003/XP/Vista/2008/7\Linux\Unix &MAC
3. Line indicator 7. Battery information USB (optional) Windows Famlly & MAC
4. Battery indicator 8. Inverter indicator Interface
Slot (optional) SNMP \ AS400 Relay Card \ Rs485
EPO (optional) Support emergency shutdown

- 45 - - 46 -
High Frequency Online UPS (Single Phase Input Single Phase Output) Solar Power System

EH5200 Series (1KVA-3KVA)


Specification

Features Model H1K H1KS H2K H2KS H3K H3KS

• Adopt DSP digital control, excellent performance indicators, more steady Capacity (VA/W) 1KVA \ 0.9KW 2KVA \ 1.8KW 3KVA \ 2.7KW
and reliable. Voltage Range Full Load:160±50%VAC~300±50%VAC;Half Load:110±50%VAC~300±50%VAC
• Adopt active power factor correction technology (PFC).
Frequency Range 40-70Hz
• Ultra-wide input voltage range, input voltages available 115V instead of turn
Phase Single phase two wire+ground wire
to battery power. Input
Distortion <5%
• With LCD+LED real-time display, UPS operating available for Detection.
Power factor 0.99
• With self- detection function, can detect hidden faults of UPS.
Generator input support
• Cold start by battery without grid Input.
• Input frequency range 40~70Hz, support various fuel generators. Voltage 220 (1±1%)VAC

• Output power factor 0.9, stronger load capacity, efficiency reach 90%, Frequency
47~53Hz \ 57~63Hz
(same frequency mode)
reduce loss of UPS.
Power Factor 0.9

Frequency (battery mode) 50±0.25Hz or 60±0.25Hz

Introduction Crest ratio 3:1

≤3%THD (Linear load)
The EH5200 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product Output
Harmonic distortion
performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as ≤6%THD (Nonlinear load)
power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion,
clutter interference, frequency fluctuation and provide best power for load. Output waveform Pure Sine Wave

Socket Universal socket *2 Universal socket *4 Universal socket *3+Terminal block

Back panel printing description LCD Display Information 100%-110%: warning sound;

Over Load 110%-130%:Automatically turns off after 1 minute, or switch to bypass mode when input correct;

1. RS232 >130%:Turn off immediately, or switch to bypass mode when the input correct
1
4
2. Breaker Charging Mode 85% 88%
4 5 Efficiency
3. AC Input Socket 3
Battery Mode 83% 85%
6
4. Intelligent Interface 2 Battery Type 12V \ 7AH 12V \ 7AH 12V \ 7AH
2
5 5. AC output socket 1 7 Battery Number 3 6 8
3 \ \ \
Equipment time (full load) >5mins >5mins >5mins
(1K/1KS) (Button Operation)
Battery Charging Time(90%) 8h 8h 8h
1. Fault Charge battery (max) 1.0A 4 1.0A 4 1.0A 4
4
1 2. Standby
Rated charging voltage 41.0±1%VDC 82.1±1%VDC 109.4±1%VDC
3. Inverter Output
Temperature detection support
4. LCD Screen
Utility to Battery 0ms
5. On/mute
Conversion time Inverter to bypass 4ms
5 6. Select
Utility Priority Mode support
7. Off/enter
2
Battery Mode alarm every 4 seconds
3

Low Power alarm  every one second


(2K/2KS) Warning Alarm
1. Parameters Over Load alarm  2 every second

1 1
2. Bypass indicator Fault continuous alarm
4
3. LINE indicator Dimension (D*W*H) mm 350*145*220 4258190*320
2 5 Shape
4. Battery indicator Net weight(Kg) 12 7 24 11 29 12
6
5. Parameters type
Micro RS-232 Windows,Linux,Sun Solaris,IBM Aix,Compaq True64,SGIRIX,FreeBSD,HP-UX and MAC
5 3
6. Load information
7 USB(Optional) Windows & MAC
4
7. Battery information
8 Connector Rabbet(Optional) SNMP \ AS400 Relay Card \ Rs485
2
8. Inverter indicator
3
(LCD Panel) EPO(Optional) Support emergency shutdown
(3K/3KS)

- 47 - - 48 -
High Frequency Online UPS (Single Phase Input Single Phase Output) Solar Power System

EH5110 Series (1KVA-10KVA)


Specification

Features MODEL H1KR H1KRS H2KR H2KRS H3KR H3KRS H6KR H6KRS H10KR H10KRS

• Adopt DSP digital control, excellent performance indicators, more steady


Capacity VA/W 1KVA \ 0.9KW 2KVA \1.8KW 3KVA \ 2.7KW 6KVA \ 4.8KW 10KVA \ 8KW
and reliable.
• Adopt active power factor correction technology (PFC). Voltage (110~300)VAC (176~276)VAC

• Ultra-wide input voltage range, input voltages available 115V instead of turn Input Frequency (40~70)Hz (46~54 \ 56~64)Hz
to battery power.
Power factor >0.99
• With LCD+LED real-time display, UPS operating available for Detection.
• With self- detection function, can detect hidden faults of UPS. External battery Standard Voltage - 36VDC 72VDC 96VDC 192VDC
• Cold start by battery without grid Input.
Battery Battery Type Maintenance-free lead-acid battery
• Input frequency range 40~70Hz, support various fuel generators.
• Output power factor 0.9, stronger load capacity, efficiency reach 90%, Battery Number 3pcs -

reduce loss of UPS.


Voltage Frequency 220(1±1% )VAC Synchronize with Input (Utility Mode)

50(1±0.2%) Hz ( Battery Mode )

Introduction 105%-125%: Automatically turns off after 1


100%-110%:Only warning sound; minute, or switches to bypass mode when
The EH5110 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product the input is normal;
Overload Capacity
performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as
Output 110%-130%:Automatically turns off after 1 minute, or switches to 125%-135%: 30 seconds or switch to bypass
power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion,
bypass mode when the input is normal; mode when the input is normal;
clutter interference, frequency fluctuation and provide best power for load.
>130%:Turn off immediately, or switch to bypass mode when the >135%: Turn off after 0.5 seconds or switch
input is normal. to bypass mode when the input is normal
Back panel printing description LCD Display Information
Output waveform Pure Sine Wave

7 6 5 4
Socket Universal Socket Terminal Block

1
Transfer Time 0ms
3
2 Others Display LCD Display LED/LCD Display (Optional)
2 5
1
Automatic restart After the battery turns off, the UPS can be automatically restarted when the utility power returns to normal.
6
3
7
Battery discharge One beep every 4 seconds when the input voltage is off; one beep per second when the battery is exhausted
4
Warning Alarm
8 9 10 11 12 8
UPS Error Keep Beeping
(LCD Panel) Intelligent monitoring functions such as Utility abnormal, power outage, battery capacity, and UPS status
13 RS-232
indication.
14 1. Parameters Connection
Option SNMP card, AS400 card, USB connection
2. Bypass indicator
3. Line indicator Temperature 0℃ ~40℃
4. Battery indicator
1. Turn on / Enter 9. Input Surroundings Humidity 20%~90%
5. Parameters type
2. Select Button 10. Intelligent Slot
6. Load information Audible Noise <55dB
3. Turn on / Mute 11. EXT.Battery
7. Battery information Host size (W*D*H)mm 482.6*450*88 482.6*600*130
4. LCD 12. Output
8. Inverter indicator
5. Inverter output 13. USB
Shape parameter Battery size (W*D*H)mm 482.6*450*88 482.6*600*130
6. Standby indicator 14. RS232 Communication Port
7. Fault indicator Host Weight (Net Weight ) kg 16.3 9.1 10.3 11.5 11.2 12.3 18.3 18.5 19.2 19.5

8. Circuit Breaker Push To Reset

- 49 - - 50 -
High Frequency Online UPS 9 (Three Phase Input Single Phase Output) Solar Power System

EH9335 Series (20KVA-80KVA)


Specification

Features Model EH9335-20KS EH9335-30KS EH9335-40KS EH9335-60KS EH9335-80KS

• Parallel Redundancy CAPACITY 20KVA \ 18KW 30KVA \ 27KW 40KVA \ 32KW 60KVA \ 54KW 80KVA \ 64KW

InputPhase 3PH 4W +G
• Output load capacity
Voltage 380
• Adaptive load three-phase unbalance
Voltage range ≥0.99
• Double conversion high frequency online design Frequenct range 45-55Hz at 50Hz \ 54-66Hz at 60Hz (auto adaptation )

• RS232,RS485 communication interface, parallel cover and Power factor 208~478Vac


SNMP card (optional ) INPUT
THDi ≤3% (100% non-linear load )

• Maintenance bypass switch Bypass protection voltage upper limit:


220V: + 25% (optional: +10% \ +15% \ +20%);
230V: + 20% (optional: +10% \ +15%);
240V: + 15% (optional: +10%);
Bypass range
Bypass protection voltage lower limit: -45% (optional:-20% \ -30%)

Bypass frequency protection range: ±10%


Introduction
Output phase (3PH 4W +G) or (1PH + N)
EH9335 Pro series three phase UPS adopts double conversion online design. Having input power factor correction (PFC) to make the input power
factor up to 0.99. Having high energy density ratio to greatly reduces its own volume and room space. Adopting digital control, the system has high Voltage 380 \ 400 \ 415Vac or 220 \ 230 \ 240Vac
stability and self-protection and fault diagnosis capabilities. This UPS series can solve power problems much better, such as voltage instantaneous drop,
amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, and frequency fluctuation. Voltage stabilizing accuracy ±1%

AC mode ±1% \ ±2% \ ±4% \ ±5% \ ±10% setting (50\60±0.2)Hz


Applications OUTPUT Frequency
Battery mode (50\60±0.2%)Hz

Load peak ratio 3:1

≤2% (linear load)
Output voltage distortion
≤5% (non-linear load)
Industry Security LRT Laboratory
Optional:DC±192V \ ±204 \ ±216V \ ±228 \ ±240V
Battery voltage
(±16 \ 17 \ 18 \ 19 \ 20)
BATTERY
Charge current 10A max

Transfer time AC mode tranfer to bypass mode: 0ms ; AC mode transfer to battery mode: 0ms

Telecom Network Hospital IDC Efficiency Normal mode ≥ 94.5%


OTHER
Communication interface USB,RS485,Dry contact, Parallel card(optional ) SNMP card (optional )

Standar YD/T1095-2008
Back panel printing description
Overlond
Normal mode ≤ 110% for 10 mins, ≤ 125% for 1 mins, ≥ 150% shut down
1 2 3 4 5 capacity
PROTECTION
Over temperature Mormal mode :transfer to bypass mode Battery model : shut down
1. SNMP
1 2 3 4 5 EPO Shut down
2. USB
Temperature 0℃~ 40℃
3. RS232
8 Storage temperature -25℃ ~55℃
6 4. EPO WORK
ENVIR
6 5. Power Relative humidity 0~95% (non condensing )
7
6. Parallel 1 Altitude < 1500m, (with derating ≥1500m )
7
7. Parallel 2
8 Machine dimension (D×W×H) 724X250X734mm 805X335X978mm
8. Maintain Switch PHYSICAL
9 9 Net weight (kg) 45 46 48 80.5 82.5
10 9. Output Switch
10
10. Input Switch

(20KVA-40KVA) (60KVA-80KVA)

- 51 - - 52 -