Non-return valves
3
A.R.I. / FIP / Cepex / VDL / GF
1

Non-return valves are frequently used to prevent water running back from
the pipe network into the water tank. They are also used to prevent water
hammer from the pipe network reaching the pump unit, thus protecting the 2
filter and preventing the mixing tank from overflowing. The flow direction is
indicated on the valve by an arrow. The most common types are disc,
Y-model and cone check valves.

Disc check valve (1)


The clapper check valve has a free passage. The valve contains a hinged clapper that in some types may be
equipped with a position indicator. A spring helps to press the disc closed. If equipped with a spring, this type of
non-return valve is not limited in the installation direction.

Y-model valve (2)


The Y-model valve has a free passage and is therefore extremely suitable for use with contaminated water.
Cylindrical weights are used. Because these valves generally do not have a spring, their installation direction is
limited. The valve must be installed so that it closes under the force of gravity.

Cone check valve (3)


The cone check valve is a spring-loaded non-return valve. This valve contains a cone-shaped, spring-loaded
closing plate. This does not have a free passage and is therefore not suitable for heavily contaminated water. As
the valve is fitted with a spring, it can be installed in any direction. The pressure loss through this type of valve is
relatively high due to the interruption of the free passage.

Technical data

Explanation of frequently used terms


Closing pressure The minimum pressure that a non-return valve requires to close completely (“sealing pressure”).
Opening pressure The pressure at which the non-return valve starts to open.
Kv value The capacity in litres/min (or m3/hour) at which 1 bar pressure loss occurs.
Working pressure The recommended maximum pressure of the valve.
Position indicator Some types of non-return valve are equipped with a visual position indicator. It is also possible to
equip these types with a limit switch.
Seal Most valves are equipped as standard with NBR or EPDM seals. Some types are also available
with special seals for acidic liquids: FPM (Viton).
Flow direction Direction in which the water (liquid) flows through the fitting (opposite to the blocking direction).
Installation direction Installation position in combination with the flow direction.

Installation & maintenance

• Check before installation whether a specific installation direction is required.


• If several non-return valves are connected in series, it is possible that not every non-return valve has
sufficient closing pressure to close completely.

10.1
Version 17.1
NR-010 non-return valve (1½” - 2”)
A.R.I.

For the smaller pipe diameters, the successful NR-010 line has a special
version in 1½” and 2”. This is a plastic, spring-loaded clapper check valve
with female screw thread connection. The NR-010 has a maximum pressure
of 10 bar. This non-return valve is easy to open on the upper side by
unscrewing the cover. This type promotes quiet closing and limits water
hammer.

This non-return valve has a completely free passage and hence low pressure loss, a particular benefit in intake
lines. Thanks to its special soft seals and an extra smooth sealing surface, this non-return valve closes even
with extremely low pressures.

Characteristics
• Suitable up to 10 bar
• Easy to open
• Glassfibre-reinforced plastic housing
• Low closing pressure
• Free passage and low susceptibility to clogging
• Resistant to most types of water used in greenhouse horticulture, such as rain, ditch and drain water

Application
NR-010
• In pressure and intake lines, also for protection of filters, in flushing systems for irrigation
(e.g. Kameleon-High).

DIMENSIONS AND WEIGHTS

Technical data
Nominal Dimensions mm Weight
Size A B C Gr.
Diameters : 1½” and 2” (BSPT, female thread)
NR -010 1½” 134 149 34.5 605
Pressure loss : see chart
NR -010 LS 1½” 134 197 34.5 635
Working pressure : up to 10 bar
NR-010 2” 134 157 40 620
Closing pressure : 0.2 mwc
NR-010 LS 2”
Material : see table and drawing 650
134 205 40

Max. temperature : 60°C (with decreasing maximum pressure)


Certification : REACH

Sizes and weights Pressure loss


Size/type Dimensions (mm)* Weight Kv value
A B C (kg) (l/min)

1½” 134 149 34.5 0.605 700


Head loss (mwc)

2” 134 157 34.5 0.620 900

* see drawing

3
Flow (m /h)

2
10.2
3
1 5
4
2 6
Version 17.1
Installation & maintenance

• Ensure that the valve is positioned in the right flow direction.


• The valve can be installed both horizontally and vertically.

Parts list and drawings


No. Description Material
1
1 Spring Stainless steel 302
2 Spring housing Acetal 2

3 Cover Reinforced nylon 3 B


4 O-ring Buna-N
4
5 Shaft housing Acetal
6 Shaft Stainless steel 316 B 5

7 Seal EPDM 6
8 Disc Reinforced nylon
7
9 Body Reinforced nylon
8
C
9

10.3
Version 17.1
NR-010 non-return valve (3” - 10”)
A.R.I.

The existing NR-010 Series with 3” and 4” non-return valves has been
extended to include a 6”, 8” and 10” version and is available in both 10 bar
and 16 bar versions.
The successor to the 2 previous NR-010 and NR-020 types is the new non-
return valve type: NR 010. This valve is a plastic, spring-loaded disc
check valve that is installed between bushes and flanges. The NR 010
is available in both 10 bar (blue arrow) and 16 bar (red arrow) versions.
This type promotes quiet closing and limits water hammer. This non-return valve has a completely free passage
and hence low pressure loss, a particular benefit in intake lines. Thanks to its special soft seals and an extra
smooth sealing surface, this non-return valve closes even with extremely low pressures. This valve is optionally
available with a position switch or suction strainer.

The valve is available both loose and preassembled between PVC flanges and bushes.

Characteristics
• Both 10 bar and 16 bar
• Plastic housing
• Low closing pressure
• Free passage

Application
• In intake lines
• In pressure lines, also for protection of filters
• Resistant to most types of water used in greenhouse horticulture, such as rain, ditch and drain water

NR-010
Technical data
DIMENSIONS AND WEIGHTS
Diameters 10 bar : 3”-90 mm, 4”-110 mm, 4”-125 mm, 6”-160 mm, 8”-200 mm, 10”- 250 mm
Diameters 16 bar : 3”-90 mm, 4”-110 mm, 4”-125 mm, 6”-160 mm, 8”-200 mm
Pressure
Nominal loss Dimensions
: see
mmchart Weight
Working
Size pressure
A B: up to C10 bar (blue
Kg. arrow)

6” 112 :
291 up to 16
220 bar (red
2.6 arrow)
Closing
LS 6”
pressure
175
: 0.2 mwc
380 220 3
Material : see table and drawing
8” 132 323 259 3.4
Max. temperature : 60°C (with decreasing maximum working pressure)
LS 8”
Option 170 413 259 3.8
: integrated stainless steel suction strainer (FV=Foot Valve)
Certification
10” 145 : REACH
376 308 4.8
LS 10” 175 465 308 5.2
Pressure loss

PARTS
3” LIST AND SPECIFICATION
to 4” 6” to 10”
+ spacer
Head loss (mwc)

Head loss (mwc)

3
Flow (m /h) Flow (m3/h)
10.4

Limit Switch Assembly


13
13
Size A B C Gr.
NR -010 3” 75 172 132 571
NR -010 LS 3” 75 219 132 580
NR-010 4” 85 191 151 732
NR-010 LS 4” 85 238 151 740

Drukverliezen (mwk)
Version 17.1
Technical specifications – Limit Switch (LS) 6”- 10”:
Principle : Mechanical limit switch (LS = Limit Switch)
Contact type : dry contact NR-010 3
Capaciteit (m /uur)
Maximum voltage : 400 VAC
Maximum current :3A DIMENSIONS AND WEIGHTS

Protection class : IP 67
13
Nominal Dimensions mm Weight
Size A B C Kg. 14

Cable connection : PG 13 gland 6”


LS 6”
112
175
291
380
220
220
2.6
3
15

16
8” 132 323 259 3.4
LS 8” 170 413 259 3.8

Sizes and weights: 3” - 10” 10”


LS 10”
145
175
376
465
308
308
4.8
5.2

Size/type Dimensions (mm) Weight (kg) Kv value PARTS LIST AND SPECIFICATION

A B C (l/min)

Drukverliezen (mwk)
3” 75 172 132 0.57 3333
4” 85 191 151 0.73 5450 B

6” 112 291 220 2.6 (excl. spacer ring) 10367


Capaciteit (m3/uu

8” 132 323 259 3.4 15033


Limit Switch As

10” 145 376 308 4.8 21283 13

14
C A
15

Sizes and weights: 6” - 10” Limit Switch (LS) 16

Size/type Dimensions (mm) Weight (kg) Kv value


A B C (l/min)

LS 6” 175 380 220 3.0 (excl. spacer ring) 10367 B

LS 8” 170 413 259 3.8 15033


LS 10” 175 465 308 5.2 21283
A
C

Installation & maintenance

• With the 6” version it may be necessary to use a spacer ring so that the disc has sufficient space to open
completely.
• Ensure that the valve is positioned in the right flow direction.
• The valve can be installed both horizontally and vertically.

10.5
NR-010 LS 4” 85 238 151 740

Version 17.1

Head loss (mwc)


Parts list and drawing - 3” and 4”
No. Description Material
1 Body reinforced Nylon
2 Disc reinforced Nylon
3 Seal EPDM
4 Bolt (x2) Stainless steel 304
3
5 Shaft Stainless steel 316 Flow (m /h)

6 Shaft housing Acetal


7 Spring housing Acetal
8 Spring cover Reinforced nylon
9 O-ring BUNA-N 13

10 Spring Stainless steel 302 14


11 Directional arrow Polypropylene
15
12 Flange seals EPDM
16

10 9
6 4

12 12

5
7

1
11

10.6
LS 8” 170 413 259 3.8
10” 145 376 308 4.8
LS 10” 175 465 308 5.2
Version 17.1

Parts
PARTSlist
LISTand
AND drawing - 6” to 10”
SPECIFICATION
No. Description Material + spacer
1 Spring cover Reinforced nylon
2 O-ring Buna-N

Head loss (mwc)


3 Flange seals EPDM
4 Body Reinforced nylon
5 Spring Stainless steel 302
6 Spring housing Acetal
7 Shaft Stainless steel 316
8 Seal EPDM
9 Disc Reinforced nylon
10 Shaft housing Acetal Flow (m3/h)
11 Bolt (x4) Stainless steel 304
12 Directional arrow Polypropylene
Limit Switch Assembly
13 Limit switch assembly Reinforced nylon
13
14 Position indicator stem Stainless steel 316
15 O-ring Buna-N 14
16 Nut Reinforced nylon
15

16

2 10 11
12
3

10.7
Version 17.1
PVC non-return valve Type 67
Cepex

The Cepex Type 67 is a spring-loaded cone check valve with rubber seals.
This valve can be installed in all directions. Thanks to its versatility and
attractive price, this check valve is interesting for a wide range of appli-
cations and with proper use offers a lasting leak-free connection.

Characteristics
• Spring-loaded
• EPDM / FPM version
• Available in a wide range of sizes

Application
• With clean water, e.g. rain water in intake and pressure lines

Technical data

Version : cone with spring L L


Diameters : 16 - 110 mm
Connection : glue with gland
Installation : free installation position

D/G
Max. working pressure : 16 bar (dia. 16 - 63)

E
: 10 bar (dia. 75 - 110)
Material : PVC (housing)
: EPDM / FPM (seals) H
: Stainless steel 302 (spring)
Max. temperature : 45°C (with decreasing max. working pressure)

Sizes and Kv values


Diameter DN L H E Kv value
(mm) (mm)       (mm)     (mm) (mm) (l/min)
16 15 16 84 52 68
20 15 16 84 52 68
25 20 19 108 62 133
32 25 22 119 70 208
40 32 26 142 84 383
50 40 31 162 94 667
63 50 38 192 117 850
75 65 44 232 148 1533
90 80 51 269 179 2100
110 80 61 279 179 2280

Installation & maintenance

• The valve can be installed both horizontally and vertically.


• Install strain-free by using brackets.
• Pay attention to the arrow for the right flow direction during installation.

10.8
Version 17.1

PVC non-return valve Type 561


+GF+

The GF non-return valve Type 561 is spring-loaded with cone or ball and
rubber seals. Thanks to its new design, this high-quality valve now has an
improved performance. The valve can be disassembled and has double
guides. With proper use, this non-return valve offers a lasting leak-free
connection. Type 561 are available in FPM and EPDM versions.

Characteristics
• Low resistance
• For radial installation and removal
• Vibration-free even at high flow velocities
• Compact installation length

Application
• Chemical process industry
• Water treatment
• Cooling

Technical data

Version : cone with spring


Diameters : 20 - 63 mm
Connection : glue with gland
Installation : free installation position
Closing pressure : 0.2 mwc
Max.working pressure : 16 bar
Material : PVC (housing)
: EPDM / FPM (seals)
Maximum temperature : 45°C (with decreasing maximum working pressure)

Kv values
Diameter DN Kv value
(mm) (l/min)
16 10 190
20 15 180
25 20 380
32 25 460
40 32 850
50 40 1080
63 50 1670

Installation & maintenance

• The valve can be installed both horizontally and vertically.


• Install strain-free by using brackets.
• Pay attention to the arrow for the right flow direction during installation.

10.9
Version 17.1
PVC VDL non-return valve
VDL

The VDL PVC non-return valve is spring-loaded with cone and has rubber
seals. The cone has guideways so that the cone is always in the right place;
these guideways also prevent the cone from rotating. As a result, this valve
is very stable during use. The VDL valve can be installed in any direction
and with proper use offers a lasting leak-free connection.

Characteristics
• Low resistance
• Spring-loaded with cone
• EPDM / FPM version
• Available in various sizes

Application
• With clean water, e.g. rain water in intake and pressure lines

Technical data

Version : cone with spring


Diameters : 16 - 110 mm
Connection : glue with gland
Installation : free installation position
Opening pressure : 0.05 bar (dia. 16 - 63)
: 0.1 bar (dia. 75 - 110)
Max. working pressure : 16 bar (dia. 16 - 63)
: 10 bar (dia. 75 - 110)
Material : PVC (housing)
: EPDM / FPM (seals)
Max. temperature : 45°C (with decreasing max. working pressure)

Sizes and Kv values


Diameter DN d2  d3 Z C Kv value
(mm) (mm) (mm)  (mm)  (mm)  (l/min)
16 10 43  10  46  75  61
20 17 59  17  58  91  147
25 22 64  22  62.5  101.5  263
32 27 73  27  75.5  120.5  388
40 33 86  33  90  143  682
50 40 102  40  108  171  1052
63 50 124  50  129  205.5  1658
75 67 151  67  164  252  1933
90 83 178.5  83  188  291  3166
110 99 215.5  99  225  348  4650

Installation & maintenance

• The valve can be installed both horizontally and vertically.


• Install strain-free by using brackets.
• Pay attention to the arrow for the right flow direction during installation.

10.10
Version 17.1

Y-model non-return valve Type 303


+GF+

Type 303 from GF is a high-quality non-return valve. It has a weight and


cannot be disconnected. The valve is available in FPM and EPDM ver-
sions. The innovative design gives a high degree of reliability and with
proper use offers a lasting leak-free connection.

Characteristics
• Low-maintenance
• Large passage
• For horizontal or vertical (up-flowing) installation

Application
• Pressure or intake line for mechanically contaminated water
• Pressure line from the pump
• Chemical process industry
• Cooling
• Water treatment

Technical data

Version : Y-model with weight


Diameters : 16 - 90 mm
Connection : glue
Max. working pressure : 10 bar
Material : PVC (housing)
: FPM / EPDM (seals)
Max. temperature : 45°C (with decreasing max. working pressure)
Dimensions
Sizes and Kv values
Diameter DN D L L1 L2 H Kv value
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (l/min)
16 10 39 114 120 24 58 41
20 15 43 124 130 28 65 95
25 20 47 144 150 37 75 180
32 25 56 154 160 37 90 327
40 32 64 174 180 44 102 484
50 40 82 194 200 48 123 725
63 50 95 224 230 60 144 1130
75 65 92 284 290 74 186 1700
90 80 104 300 310 85 204 2500

Installation & maintenance

• The valve can be installed in vertical and horizontal position, but the weight must always be facing upwards.

10.11
Version 17.1
Y-model non-return valve - adhesive insert VRUIV
FIP

The FIP VRUIV non-return valve is a non-spring-loaded, removable valve


with weight, in smaller diameters. This valve can be installed horizontally
and vertically and can be employed with mechanically contaminated water
in small waste water installations. Available as standard in EPDM version.
FPM O-ring sets are available separately. With proper use, the VRUIV
offers a lasting leak-free connection.

Characteristics
• Disconnectable
• Large passage
• Adaptable to FPM version
• Resistant to mechanical contamination

Application
• Pressure and intake lines with rain water, ditch water, drain water, coarse contamination and liquid fertiliser
installations

Technical data

Version : Y-model with weight


Diameters : 16 - 63 mm
Connection : glue with gland
Max.working pressure : 16 bar
Material : PVC (housing)
: EPDM / FPM (seals)
Max. temperature : 45°C (with decreasing max. working pressure)

Sizes and Cv values


Diameter  DN          A         B  E L Z H Weight Kv value
(mm) (mm) (mm) (mm)      (mm) (mm) (mm) (mm) (gram) (l/min)
16 10 125 72 55 14 107 135 218 47
20 15 125 72 55 16 103 135 226 110
25 20 145 84 66 19 120 158 388 205
32 25 165 95 75 22 132 176 606 375
40 32 190 111 87 26 155 207 923 560
50 40 210 120 100 31 181 243 1335 835
63 50 240 139 120 38.2 221 298 2313 1300

Installation & maintenance

• Install strain-free by using brackets.


• Pay attention to the arrow for the right flow direction during installation.
• The valve can be installed in vertical and horizontal position, but the weight must always be facing upwards.

10.12
Version 17.1

Y-model non-return valve - adhesive insert VRIV


FIP

The FIP VRIV non-return valve is not spring-loaded, but is equipped with a
weight. The valve cannot be disconnected. This valve is available in larger
diameters. It can be installed both horizontally and vertically. Available in
EPDM. FPM O-ring sets are available separately.

Characteristics
• Equipped with a weight
• Large passage
• For larger diameters

Application
• Pressure and intake lines with rain water, ditch water, drain water, coarse contamination
• Pressure line from the pump

Technical data

Version : Y-model with weight


Diameters : 75 - 110 mm
Connection : adhesive insert
Max. working pressure : 10 bar (dia. 75)
: 6 bar (dia. 90 - 110)
Material : PVC (housing)
: EPDM / FPM (seals)
Max. temperature : 45°C (with decreasing max. working pressure)

Sizes and Kv values


Diameter DN Amax B E L Z H Weight Kv value
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (kg) (l/min)
75 65 300 179 104 44 155 243 3.485 1950
90 80 325 192 116 51 160 262 4.530 2600
110 100 385 231 138 61 203 325 7.170 3500

Installation & maintenance

• The valve can be installed in vertical and horizontal position, but the weight must always be facing upwards.

10.13
Version 17.1
Brass non-return valve
York

The York brass non-return valve is an old and reliable player in the field.
This sturdy valve has a screw thread.
The valve can only be used in clean water installations and is not resistant
to fertilisers or to mechanical or chemical contamination. The brass non- 103
return valve is available as an intermediate valve and as a foot valve with
stainless steel strainer. YORK ® CHECK VALVE

Characteristics
• Sturdy design

Application
• Clean water installations with rain water and spring water

Technical data

Diameters : ⅜”- 4”
1
Connection : BSPT
Installation : free installation position 2

Max. working pressure : 10 bar (⅜” - 1”) 3


: 8 bar (1¼” - 2”)
H

: 6 bar (2½” - 4”)


4
Material : brass (housing) 5

Max. temperature : 45 °C
L

Sizes
DN     G          L H Kv value G
(mm)  (”) (mm)       (mm) (m3/h) D

15      ½”       10.3        47 4.5


20      ¾“         11.5        50.4 8 Parts list
25      1”          12.9        52.7 12 No. Description Material
32     ¼”     14.5       65.5 22 1 Body Brass
40      ½”      13.9       68.3 29 2 Pin Polymer
50      2”          14.1        77 51 3 Spring Stainless steel 302
65    2½”      25.3       101 70 4 Washer NBR
80      3”          23.1        103 99 5 Plate Polymer
100     4”        25            113 158 6 End adapter Brass

Installation & maintenance

• The valve can be installed both horizontally and vertically. POS . DESCRIP T ION N. MAT ERIA L

1 Body 1 Brass CW617N


®

2 Pin 1 Polymer

3 Spring 1 Stainless steel AISI 302

4 Washer 1 NBR

5 Plate 1 Polymer

6 End adapter 1 Brass CW617N

10.14
Version 17.1

2-way solenoid valve


FIP

The FIP solenoid valve S12-S22 is a direct-acting solenoid valve with a


lever principle. Thanks to its optimum design, this solenoid valve is suitable
as an EC or pH control or selection valve.

Characteristics
• 2-way, normally closed
• Lever principle
• Operation separate from medium
• LED indicator light
• Manual actuation with 3 different positions (open / closed / automatic)
• Practically maintenance-free electric actuator
• Simple maintenance

Application
Ideal for metering systems. Suitable for EC and/or pH control.

Technical data

Diameter : dia. 16 mm (S12)


: dia. 16 / 20 mm (S22)
Coil : 2-way NC
Liquid viscosity : max 38 mm2/s
Electrical connection : 24 VAC or 24 VDC
Power consumption : S12 - 10W
: S22 - 20W
Closing /opening time : approx. 20 msec
Max. working temp. : 50°C (with decreasing max. working pressure)
Material : PVC-U (housing)
: EPDM / FPM (seal)
Protection class : IP65
Connection : bush with screw gland
Option : 230 VAC (50/60 Hz)

Capacity (l/min) and pressure class (bar)


Diameter type DN Kv value NP
(mm) (mm) (l/min) (bar)
16 S12IV 8 15 2
16 S22IV 10 34 4
20 S22IV 10 34 4
20 S22IV 15 58 2

Installation & maintenance

• Install the solenoid valve in the flow direction indicated.


• The valve can be installed both horizontally and vertically.

10.15
Version 17.1
Solenoid valve Type 160
+GF+

This solenoid valve is a direct-acting valve. It is used as a fertiliser selection


valve in modern greenhouse horticulture.

Application
Fertiliser selection valve

Technical data

Model : 160 A (straight-through flow)


Material : PVC-U (body)
: EPDM (seal)
Operation : automatic with manual override
Voltage : 24 VAC or 24 VDC
Power : 9 W (continuous) 100 W (inrush)
Electrical connection : cable and plug
Protection class : IP 65
Option : Viton seal
: 230 VAC 50 Hz

Sizes and Kv values


Diameter DN L L1 L2 NP Kv value
(mm) (mm) (mm)  (mm)  (mm)  (bar)  (l/min)
20 10 30 17 14 0-3 33
25 15 33 19 16 0-1 75
25 20 37 22 19 0-1 100

Installation & maintenance

• An EPDM overhaul set (02265-690610) is available for maintenance.


• Install the valve in the flow direction indicated.

10.16
Version 17.1

Diaphragm valve 514/515


+GF+

The manually actuated diaphragm valve from GF ensures a safe and


precise setting of the liquid flow and shuts off the passage completely,
if required. A plastic housing gland ensures a corrosion-free connection to
the housing of the valve.

The diaphragm separates the moving parts from the medium to be


transported. A constricted passage ensures an accelerated linear flow.

As standard the GF diaphragm valve is equipped with a lockable handwheel and a two-colour position indicator.
The 514 Series has a gland fitting, the 515 Series a glue fitting.

Characteristics
• Sleek housing
• Resistant to corrosion and chemicals
• Homogeneous flow even with temperature fluctuations
• Uniform surface pressure
• Equipped with two-colour position indicator
• Lockable handwheel
• Short installation length

Application
Chemical industry (fertiliser units), water treatment systems, foodstuffs industry.

Technical data

Type 514 Type 515


Connection : bush with screw gland : glue fitting (wedge end)
Diameter : 20 - 63 mm : 25 - 63mm
Pressure class : PN10 : PN10
Material : PVC-U (housing) PVC-U (housing)
: EPDM (diaphragm) EPDM (diaphragm)

Sizes and Kv values


Diameter DN D D2 D3 H H1 H2 L L2 M z Hx NP Kv
value
(mm) (mm) (mm) (mm)  (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (bar)  (l/min)
20 15 65 65 43 73 14 12 128 25 M6 96 7 10 125
25 20 80 65 51 81 18 12 152 25 M6 114 10 10 271
32 25 88 87 58 107 22 12 166 25 M6 122 13 10 481
40 32 101 87 72 115 26 15 192 45 M8 140 15 10 759
50 40 117 135 83 148 32 15 222 45 M8 160 19 10 1263
63 50 144 135 100 166 39 15 266 45 M8 190 25 10 1728

Installation & maintenance

• The diaphragm valve can be installed in both horizontal and vertical position.

10.17
Version 17.1
Diaphragm valve with glue end VMDV
FIP

The FIP diaphragm valve has an integrated mounting base and is equipped
as standard with a position indicator.

Application
For precise control of flow rates

Technical data

Model : VMDV
Connection : Glue
Diameters : 20-110 mm
Materia l : PVC-U (body)
: EPDM (diaphragm)
Option : FPM or PTFE diaphragm
: gland connection

Sizes and Kv values


Diameter DN B  B1 H h H1 J L Kv value
(mm) (mm) (mm) (mm)  (mm)  (mm)  (mm) (mm) (l/min)
20 15 95 26 124 12 90 M6 16 93
25 20 95 26 144 12 90 M6 16 136
32 25 95 26 154 12 90 M6 23 175
40 32 126 40 174 18 115 M8 27 300
50 40 126 40 194 18 115 M8 32 416
63 50 148 40 224 18 140 M8 39 766
75 65 225 55 284 23 215 M12 44 1300
90 80 225 55 300 23 215 M12 51 2000
110 100 295 69 350 23 250 M12 51 2700

Parts list and drawing


No. Description
1 Handwheel
2 Bonnet
3 Compression bearing
4 Security ring
5 Indicator stem
6 Compressor
7 Pin
8 Sealing diaphragm
9 Valve body
10 Washer
11 Hexagonal screw
12 Protective cap

10.18
Version 17.1

Y-model free-flow valve


FIP

The free-flow valve (45°) is suitable for controlling the flow of clean liquids.

Characteristics
• Maintenance is possible without removal from the line.

Technical data

Models : VVUIV (double gland: adhesive insert)


: VVIV (adhesive insert)
Diameter : 16-110 mm
Max. pressure at 20°C : PN16 (dia. 16-32 mm), PN10 (dia. 40-75 mm), PN6 (dia. 90-110 mm)
Material : PVC-U (housing)
: EPDM (seal), optionally FPM
Connection : bush with screw gland (dia. 16-63 mm), glue fitting (dia. 75-110 mm)

Size (screw thread)
Diameter DN Bmax C E H L Z Amax Kv
value
(mm) (mm) (mm)  (mm)  (mm)  (mm) (mm) (mm) (mm) (l/min)
16 10 124 60 55 135 14 107 170 47
20 15 124 60 55 135 16 103 173 110
25 20 146 60 66 158 19 120 197 205
32 25 173 70 75 176 22 132 223 375
40 32 195 85 87 207 26 155 258 560
50 40 222 105 100 243 31 181 295 835
63 50 269 130 120 298 38 222 359 1300

Parts list and drawing


No. Description No. Description No. Description
1 Handwheel 6 Body 11 Bottom bush
2 Union nut 7 Swivel plug 12 Gland
3 O-ring 8 Stem 13 Socket seal O-ring
4 Gland packing 9 Lock nut 14 End connector
5 Fork 10 Bonnet 15 Union nut

10.19
Version 17.1

Y-Filter
FIP

The FIP Y-Filter screens and collects solid particles from the water flow
by means of a filter screen. The screen is easy to remove for maintenance.

Characteristics
• Filtration from 300 to 900 micron
• Easy to clean
• Transparent or grey PVC housing

Technical data

Models : RVUIT (double gland: adhesive insert, transparent)


: RVUIV (double gland: adhesive insert, grey)
: RVIT (adhesive insert, transparent)
: RVIV (adhesive insert, grey)
Diameter : 16 - 110 mm
Pressure class : PN16
Max. pressure at 20°C : PN16 (dia. 16 - 63 mm), PN10 (dia. 75 mm), PN6 (dia. 90 - 110 mm)
Dirt trap material : PVC or transparent PVC (housing)
: PVC (strainer)
: EPDM (seal), optionally FPM
Connection : bush with screw gland (dia. 16-63 mm), glue fitting (dia. 75 - 110 mm)
PVC screen size : 1.5 mm ~ 500 micron (standard)
Sizes (optional) : 1 mm ~ 300 micron
: 2 mm ~ 600 micron
: 2.5 mm ~ 900 micron
: 0.7 mm ~ 370 micron (stainless steel strainer)

Kv value (l/min)
Diameter (mm) 16 20 25 32 40 50 63 75 90 110
Kv value 22 40 70 103 188 255 410 650 1050 1700

Parts list and drawing


No. Description No. Description
1 Body 7 Lock nut
2 Screen 8 Split ring
3 Bonnet 9 Socket seal O-ring
4 Screen support housing 10 End connector
5 O-Ring seal 11 Union nut
6 Retaining ring

Installation & maintenance

• Install the dirt trap with the arrow in the direction of the liquid flow and the dirt trap facing downwards.

10.20
Version 17.1

Suction strainer Type 050


+GF+

The GF strainer prevents coarse contaminants entering the intake line


and can thus prevent damage occurring to the pump installation.
The strainer is installed by means of a glue joint and has a sturdy
construction.

Characteristics
• Different diameters
• Glue joint

Technical data

Diameter : 20-63 mm
Material : PVC-U
Connection : glue joint
Mesh width : 1.5 - 6 mm

Kv value (l/min)
Diameter (mm) 20 25 32 40 50 63
Kv value 105 228 390 563 813 1590

10.21
Version 17.1
MixRite dosing pump
Tefen

The Tefen MixRite is a proportional dosing pump that enables fertilisers


or chemicals to be easily admixed into a water flow. The pump requires
no external power supply and operates with water pressure. The pump
operates proportionally, i.e. a set percentage of the product to be mixed is
added, independently of the water flow.
MixRites are available with a capacity from 20 litres to 25 m³/h.

Characteristics
• Simple operation and very quick to set up
• With manual ON/OFF button or manual air release
• Various adjustable intake capacities possible
• Metering capacity is proportional to the water flow and independent of the pressure
• Mixes pumped liquid with the water flow (except MixRite by-pass)
• Resistant to common fertilisers and pesticides used in agriculture and horticulture.
• Special MixRites for aggressive chemicals are also available
• Made from high-quality plastic and UV-resistant
• Supplied complete with intake hose and filter
• Simple maintenance, seals are easy to replace

Application
Dosing of fertilisers or pesticides, cleaning agents, animal medicines and metering of chlorine. Various types /
models are available, each model / type with its own specific application.

Technical data

Connection 12500 / 2500 (2.5 m3) : ¾” male thread


TF-5 : 1” male thread
TF-10 : 1½” male thread
TF-25 MixRite
: 63 mm PE TF-10
coupler (adapter 2½”)
Recommended working pressure : 1.5 - 6 bar
Maximum pressure : 8 bar
Maximum suction height : 2.5 metre
Temperature range : 4 - 50°C (with decreasing maximum pressure)
Option : PVDF version for very aggressive chemicals
for the MixRite 12500 / 2500 (2.5 m3)

Working principle

On/off switch

Water motor

Water inlet Water outlet with


additives
Suction with
proportional dosing
(adjustable)
Connection
suction hose

10.22
Version 17.1
Overview of MixRite applications and chemical resistance
Standard Industry Internal Chlorine Livestock
STD C by-pass CL PO

Adding of Hydrogen Sulphuric and Chlorine and acids Medicines,


Indicative application fertilisers peroxide hydrochloric up to 10% vitamins, etc. in
to irrigation water acid up to 10% livestock farming

Type Metering* Specifications Article No.

2502 0.3 - 2% 76420-001000 76420-001042

2505 5% (fixed) 76420-001200

12500 0.2% (fixed) 76420-000950


P = 0.2 - 8 bar
12502 0.3 - 2% Q = 7 - 2500 l/h 76420-001050
DP 10% = 0.2 - 1.8 bar
12504 0.4 - 4% DP 4% = 0.2 - 1.6 bar 76420-001100
DP 2% = 0.2 - 1.6 bar
12512 0.3 - 2% DP 0.2% (fixed) = 0.2 - 1.2 76420-001370 76420-001046
bar
12514 0.4 - 4% 76420-001109

TF5 0.1 - 1%
P = 1 - 8 bar
0.2 - 2% 76420-000290 76420-000292
Q = 0.2 - 5 m3/h
1 - 5% DP = 0.1 - 0.8 bar

TF10 0.1 - 1% 76420-000357


P = 1-8 bar
0.2 - 2% 76420-000365 76420-000294
Q = 0.5 - 10 m3/h
1 - 5% DP = 0.1 - 0.9 bar 76420-000375

TF25 0.3 - 2.5% P = 1 - 8 bar 76420-000480 76420-000435


Q = 2 - 25 m3/h
1 - 5.5% DP = 0.2 - 1.5 bar 76420-000470

Type Concentration Chemical resistance**

Organic acids All concentrations - - o - +


Animal medicines All concentrations - o o - +
Ammonium nitrate All concentrations + + + + +
Sulphuric acid up to 10% - - o + -
above 10% - - - - -
Hydrochloric acid up to 10% - o o + o
above 10% - - - - -
Nitric acid up to 10% - - o + o
above 10% - - - - -
Phosphoric acid up to 10% - - - + -
above 10% - - - - -
Hydrogen peroxide up to 10% - + + + +
above 10% - - - + -
MultiFertilizer NPK All concentrations + + + + +

* A MixRite has a higher accuracy in the upper part of the dosing range ** Meaning: + = YES O = OK - = NO
The TF-5 and TF-10 are supplied with a plastic wall plate, the TF-25 with a stainless steel wall plate and plastic stand.

10.23
Version 17.1

Installation & maintenance

Positioning
• The MixRite can be installed in the main flow or in a by-pass if the available flow is higher than the
maximum permitted capacity.
• Avoid excessive resistance on the intake side (maximum intake height: ± 2.5 mwc).
• If the MixRite is installed in the by-pass, a possibility for reducing must be installed in the main flow such
that the resistance through the MixRite (with the desired capacity) is equal to the resistance through the
reducer in the main flow (note: maximum capacity by means of water meters).

Setting
• The intake capacity of the MixRite can be easily adjusted by turning the gland on the pump unit.
• After turning, the setting can be locked by means of a locking pin.

Maintenance
• If the MixRite is not used for a prolonged period, flush it well using clean water.
• The housing of the MixRite is impact-resistant (glassfibre-reinforced polyamide). Do not use a (chain)
wrench to loosen the cap.
• Proceed as follows to replace the seals: Remove the old seals using pliers, heat the new seals to be
installed in hot water, fit the seals and then apply silicone grease. Allow the drive unit to protrude slightly to
avoid damage to the seals during installation of the cap.

10.24
Omschrijving Revaho
Version 17.1

MixRite 12500 Series (2.5 m3/h) parts Samengestelde Kits Artikel

Tefen Nr. en Losse Onderdelen Nummer Cod

A Kit: Seal 0,2-2% 458350 A


Compiled kits
B Kit: Suction piston 0,2-2% 458352 A
No. Description Art. No.
C A Kit:Kit:Suction
Seal 2% tube 0,2-2% 458354
76420-006050 A
D Kit:Kit:Checkvalve
Seal 4% 0,2-2% 458357
76420-006100 A
Kit: Seal 5% --------
E Kit: Mechanism spring 458360 A
B Kit: Suction piston kit 2% 76420-003010
F Kit:Kit:Suction cylinder 0,2-2%
Suction piston kit 4%
458361
76420-003020
A
G Kit:Kit:U-Latch
Suction piston kit 5% 458363
-------- A
48 C Kit:Kit:O-rings
Suction tube 2% 458367
76420-001610 A
Kit: Suction tube 4% 76420-001620

Kit: Suction tube 5% --------


Losse onderdelen
D Kit: Suction check valve 0.2 - 2% 76420-003500
10 Ejector Pin
Kit: Suction check valve 0.4 - 4%
458370
76420-003240
A
11 E Cylinder Toggle
Kit: Mechanism spring 458371
76420-006150 A
12 F Upper valve
Kit: Suction cylinder 2% 458372
76420-002707 A
Kit: Suction cylinder 4% 76420-002708
18 Cylinder Toggle slide 458373 A
Kit: Suction cylinder 5% --------
23 Cylinder Axle 458374 A
H Kit: Manual on/off --------
24 G Lower valve
Kit: U latch 458375
76420-002500 A
25 Ejector Slide
48 Kit: O-rings 0.2 - 2%
458376
76420-003065
A
Kit: O-rings 0.4 - 4% 76420-003070
26 Pin 458377 B
Water motor --------
28 Lower valve spring 2 458378 A
29 Upper valve spring 3
Loose parts 458379 A
40No.Screw Stainless Steel
Description 458380
Art. No. A
51 Disc Stainless Steel
10 Ejector pin
458381
76420-002420
A
11 Cylinder toggle 76420-002485
63 12
On/Off Bar
Upper valve
458382
76420-007010
A
71 18Peg
Cylinder toggle slide 458383
76420-002487 A
23 Cylinder axle 76420-002495
24 Lower valve 76420-007040
25De Ejector
MixRite slide12502 is voor algemene76420-002430
toepassing zoals
26dosering
Pin van meststoffen en zepen.76420-007110
28 Lower valve spring 2 76420-001845
De MixRite 12502 heeft een aan/uit knop.
29 Upper valve spring 3 76420-001865
40 Screw stainless steel 76420-002470
51
De MixRite wordt geleverd
Disc stainless steel
door:
76420-007150
63 On/Off bar 76420-002220
71 Peg 76420-002450

PvE 9-2008

10.25
KITS FOR: Version 17.1
MixRite 2500 Series (2.5 m /h) parts
3

Tefen
MixRite 2512 - STD Last update:
04/12/2007

Compiled kits
G Loose parts
A SEALNo.
KIT Description
36000000032 Art. No.
No.
A
Description
Kit: Seal 2%
Art. No.
76420-006050
10 Ejector pin 76420-002420
Kit: Seal 4% 76420-006100
11 Cylinder toggle 76420-002485
Kit: Seal 5% --------
B SUCTION
12 PISTON KIT
Upper valve 36000000041 76420-007010
A B
18
Kit: Suction piston kit 2%
Cylinder toggle slide
76420-003010
76420-002487
Kit: Suction piston kit 4% 76420-003020
23 Cylinder axle 76420-002495
24 Kit:
LowerSuction
valvepiston kit 5% --------
76420-007040
F C SUCTION TUBE KIT 36000000024
25
C Ejector
Kit: slidetube 2%
Suction 76420-002430
76420-001610
26 Pin Suction tube 4%
Kit: 76420-007110
76420-001620
28
Lower valve spring 2 76420-001845
G D
Kit: Suction tube 5%
CHECK VALVE KIT 36000000022
--------
29 Upper valve spring 3 76420-001865
D Kit: Suction check valve 0.2 - 2% STD 76420-003500
40 Screw stainless steel 76420-002470
A Kit: Suction check valve 0.2 - 2% CL 76420-003508
51 Disc stainless steel 76420-007150
E MECHANISM Kit:
SPRING
Suction KIT 36000000001
check valve 0.2 - 2% PO 76420-003504

Kit: Suction check valve 0.4 - 4% STD 76420-003240

Kit: Suction check valve 0.4 - 4% 76420-003260


F SUCTION CYLINDER
Bypass KIT 36000000007
E Kit: Mechanism spring 76420-006150

D G U LATCH
F KIT 36030167916
Kit: Suction cylinder 2% 76420-002707
Kit: Suction cylinder 4% 76420-002708

Kit: Suction cylinder 5% --------

H CONICAL
H SEAL KIT on/off
Kit: Manual 36000000056 --------
G Kit: U latch 76420-002500
48 Kit: O-rings 0.2 - 2% STD 76420-003065
Kit: O-rings 0.2 - 2% PO 76420-003060

Kit: O-rings 0.4 - 4% STD 76420-003070

Kit: O-rings 0.4 - 4% Bypass 76420-003075

Water motor --------


E

B
C
H

10.26
F5 TF 5
MixRite TF 5 parts
Version 17.1

Releaser Air Releaser


Tefen

Compiled kits
No. Description STD Art. CL Art.
No. No.
A Kit: Seal 0.1 - 1% T 35200000001 T 35200000001
Kit: Seal 0.2 - 2% 76420-006133 76420-006133

Kit: Seal 1 - 5% T 35200000005 T 35200000005

C Kit: Suction tube 1% & 2% T 36000000021 T 36000000021


Kit: Suction tube 5% T 36000000028 T 36000000028

D Kit: Suction check valve T 35200000004 T 36000000152

TF 5 A
E
F
Kit: Mechanism spring
Kit: Suction cylinder 0.1 - 1%
T 35100000045
T 35200000009
T 35100000045
T 35200000050
A Kit: Suction cylinder 0.2 - 2% T 35200000011 T 35200000051
Air Releaser Kit: Suction cylinder 1 - 5% T 35200000012 T 35200000052
D
D
G Kit: Suction piston kit 0.1 - 1% T 35200000019 T 35200000019
Kit: Suction piston kit 0.2 - 2% T 35200000020 T 35200000020

Kit: Suction piston kit 1 - 5% T 35200000021 T 35200000021

H Kit: Manual on/off T 35200000048 --------


A
Water motor T 35200000006 --------
A

67 69
67 69 68
E 68

A G C 105
G C 105

A
A D

F
A F

TEFEN
67 69

TEFEN
68
E
TEFEN Manufacture & Marketing Plastic Products (1990) LTD. Kibutz Nahsholim 3081500 Israel
FLOW & DOSING TECHNOLOGIES
TEFEN Manufacture & Marketing | Tel.Plastic Products|(1990)
972 4 6395554 LTD.
Fax. 972 Kibutz Nahsholim
4 6390813 3081500 Israel | www.tefentech.com
| export@tefentech.com
& DOSING TECHNOLOGIES | Tel. 972 4 6395554 | Fax. 972 4 6390813 | export@tefentech.com | www.tefentech.com

G C 105

10.27
TEFEN
FLOW & DOSING TECHNOLOGIES
TEFEN Manufacture & Marketing Plastic Products (1990) LTD. Kibutz Nahsholim 3081500 Israel
| Tel. 972 4 6395554 | Fax. 972 4 6390813 | export@tefentech.com | www.tefentech.com
TEFEN
Version 17.1
MixRite TFTEFEN
10 parts
TEFEN Advanced Plastic Solutions.
Tefen
TEFEN Advanced Plastic Solutions.

Compiled kits
82
No. Description STD Art. CL Art. No.
H
82 83 No.
H 88 A Kit: Seal 0.1 - 1% T 35100000001 T 35100000001
83 85
87
89 Kit: seal 0.2 - 2% 76420-006130 76420-006130
88 85
87 84
Kit: seal 1 - 5% 76420-006120 76420-006120
89 86
84 C Kit: Suction tube 1-2-5% T 36000000028 T 36000000028
86 91
D Kit: Suction check valve 76420-003220 T 36000000152
A 90
91 E Kit: Mechanism spring 76420-006170 76420-006170
90
F Kit: Suction cylinder 0.1 - 1% T 35100000009 T 35100000009
Kit: Suction cylinder 0.2 - 2% 76420-006239 76420-006239
TEFEN
Kit: Suction cylinder 1 - 5% 76420-006242 76420-006242
D

Kit: Suction piston kit 0.1 T 35100000019 T 35100000019


TEFEN Advanced Plastic Solutions. D
- 1%
G Kit: Suction piston kit 0.2 76420-006238 76420-006238
- 2%
A
Kit: Suction piston kit 1 - 5% T 35100000021 T 35100000021
A
H Kit: Manual on/off T 35100000016
82
Water motor T 35100000006 T 35100000006
H
83
Water motor overhaul set 76420-006230
88 85
87
89
84
Loose parts
C
86 No. Description Art. No.
E
C 8 Latch nut 76420-006255
91
E 90 10 Cylinder support spacer 76420-006855
A
12 Large exit valve 3 76420-006910
G A
13 Central valve 3 76420-006920
A 14 Toggle frame 76420-006445

F D 15 Toggle 76420-006465
1% TF10
16 Toggle pin 76420-006448
F
17 Bridge pin 76420-006930
21 Toggle bearing 76420-006451
A 22 Piston bar 0.2-2% and 1-5% 76420-006143
14 24 Suction piston 0.2-2% 76420-006470

14 24 Suction piston 1-5% 76420-006458


26 Operation rod 76420-006458
31 O-ring 2-362 76420-006420
32 O-ring 2-334 76420-006092
43 Washer for swivel ¾” --------
C 52 Ejote screw WN1412 76420-006430
E 53 Washer St.St. --------
56 Spring large valve 76420-006940
61 O-ring 2-107 76420-002905

G A 64 O-ring 2-118 --------

66 Inner valve --------


67 Small exit valve --------
F
1% TF10 68 Small exit valve spring V7 engine --------
79 Inner valve spring 76420-006066
81 Inner valve locker 76420-006079

10.28 14
Version 17.1
TEFEN TEFEN
MixRite TF 25 parts
Tefen TEFEN Advanced Plastic Solutions.
TEFEN Advanced Plastic Solutions.

82 82
Compiled kits
83 83
No. Description STD Art. No.
67 67 88 85 88 85
A Kit: Seal 0.1 - 1% T 35000000008
6 6 87 87
89 89 Kit: Seal 0.3 - 2.5% 76420-005900
H 84 H 84
86 Kit: Seal 1 - 5.5% 76420-006000
86
A A C Kit: Suction tube 1% & 2% & 5% T 35000000049
91 91
65 65 D Kit: Suction check valve 1% & 2% 76420-003218
90 90
E Kit: Suction check valve 5% 76420-006010
F Kit: Mechanism spring T 35000000045
Kit: Suction cylinder 0.1 - 1% T 35000000009
Kit: Suction cylinder 0.3 - 2.5% 76420-006241
D D Kit: Suction cylinder 1 - 5.5% 76420-006244
A A TEFEN G Kit: Suction piston kit 0.1 - 1% T 35000000019
Kit: Suction piston kit 0.3 - 2.5% T 35000000020
H Kit: Suction piston kit 1 - 5.5% T 35000000021
TEFEN Advanced Plastic Solutions.
Kit: Manual on/off T 35000000048
Water motor T 35000000049
71-77 Stand stainless steel 76420-005800
82
Stainless steel wall plate 76420-002414
83
Spanner cover nut 76420-006055
67 88 85 Taper 63 mm PE x 2.5" thread 76420-001869
6 87
89
E E H 84 Loose parts
86
No. Description STD Art. No.
A
91 C 8 Latch nut 76420-006055
65 C
90
12 Large exit valve 3 76420-006078
13 Central valve 3 76420-006500
14 Toggle frame 76420-006550
F F
A
15 Toggle 76420-006832
A

G
16 Toggle pin 76420-006830
G D
17 Bridge pin 76420-006840
A
21 Toggle bearing 76420-006236
22 Piston bar 0.3-2.5% and 1-5.5% 76420-006145
15 15 24 Suction piston 0.3-2.5% 76420-006820
26 Operation rod 76420-006459
31 O-ring 2-370 76420-006095
32 O-ring 6x105 76420-006424
43 Seal 1" 76420-005620
44 Record body 25x1" 76420-005650
52 Ejote screw WN1412 76420-006068
E 53 Washer St.St. 76420-006069
55 Suction tube 25mm 2,5 m 76420-006879
56 Spring large exit valve
C
61 O-ring 2-107 76420-002905
64 O-ring 2-118

65 Dalrin ring
F
A
66 Inner valve V7 engine 76420-006560

G
67 Small exit valve V7 engine 76420-006570
68 Small exit valve spring V7 engine 76420-006835
79 Inner valve spring V7 engine 76420-006580
81 Inner valve locker V7 engine 76420-006079
15 10.29
Version 17.1
Venturi injectors
Mazzei

Injectors from Mazzei are high-quality injectors that inject liquid into a
flow on the basis of a pressure difference (venturi principle).
When a continuous liquid steam enters the injector under pressure,
it passes at high speed through a small opening into the injection chamber.
The increase in speed creates a vacuum so that the liquid to be admixed is
drawn in.

Characteristics
• High efficiency (20% pressure loss on starting)
• No electrical power supply required
• Low maintenance: No moving parts
• Made from high-quality thermoplastics (PP and PVDF)
• Significant cost savings compared with other injection methods
• Safe to use for injection of common chemical agents under vacuum

Application
Injection of liquid or gas into irrigation, insecticide, washing and/or swimming pool systems.

Technical data

Connection : ½” - 2” BSPT
Working pressure : 1.4 - 7.0 bar (with ΔP-dependent capacity)
Material : reinforced polypropylene
Option : Stainless steel, PVDF (Kynar®) or ECTFE
Also available : Kit with 3 metre clear hose, manual control valve, filter

Overview of types
Model Art. code Inlet/out- Con- Min Drive Injection Weight Intake Art. code
let nection ΔP* at 3.5 bar capacity** (kg) kit Intake kit
(male Intake (%) (l/min) (l/min) (separately
thread) hose available)
287 02267-455175 ½” 3/16” bush 27 3.2 0.52 0.03 K-184 02267-455210
384X 02267-455177 ½” ¼” bush 25 8.1 2.21 0.09 K-184 02267-455210
484 02267-455180 ½” ¼” bush 18 12.9 1.07 0.11 K-184 02267-455210
484A 02267-455183 ¾” ¼” bush 18 12.9 1.07 0.11 K-184 02267-455210
584 02267-455185 ¾” ¼” bush 18 24.2 1.58 0.11 K-184 02267-455210
878 02267-455190 1” ⅜” bush 16 45.4 3.79 0.25 K-183 02267-455217
885X 02267-455193 1” ⅜” bush 32 46.6 8.83 0.25 K-183 02267-455217
1078 02267-455195 1” ⅜” bush 16 64.7 4.73 0.25 K-183 02267-455217
1583A 02267-455200 1½” ½” bush 18 129.4 11.36 0.42 K-183 02267-455217
2081A 02267-455205 2” 1¼” 18 382.3 31.54 0.64 K-282 02267-455218
2083X 02267-455207 2” 1¼” 67 111.3 71.28 0.64 K-282 02267-455218

*: Minimum pressure difference (inlet/outlet) required before the start of intake


**: Maximum intake capacity at 3.5 bar pressure difference over the injector

10.30
Version 17.1

Installation & maintenance

• The capacity of the injector is regulated by varying the ingoing flow and/or intaken flow.
• The maximum capacity is achieved at +/- 50% ΔP (depending on the type).
• An automatic injection system can be protected against running dry and draining during standstill using an
¾” NC valve (or a Dorot 1½” NC) between the chemicals tank and the injector. As long as there is no
pressure on the main line, the NC valve shuts off the supply to the injector,

Injector positioned parallel to the main flow

Injector positioned around a pressure regulator that creates a pressure


difference

Injector positioned in the main flow Injection starts when


the valve is closed. When the valve is opened, injection
stops due to the drop in pressure.

Injector in combination with a pump so that a pressure


Injector positioned as a “by-pass” over a pump difference is created.
valve from pressure to intake side.

10.31
Version 17.1
Air & Vacuum valve AV-10
A.R.I.
AV-010
The A.R.I. AV-10 is a plastic kinetic air & vacuum valve that can admit or
discharge large quantities of air to/from a system. The air & vacuum valves
are used predominantly where the installation is regularly drained and filled
to prevent implosion (due to vacuum) and water hammer (due to water
columns 'springing
DIMENSIONSback'). Good venting allows the system to be filled faster
AND WEIGHTS
and more safely.
Nominal Dim. mm Weight A
Characteristics
Size A B Kg. mm2 3/4" 1"
• Dynamic design that functions up to very large pressure difference (0.7 bar pressure difference for air
3/4” (20mm) 60 124 0.1 314
release); prevents premature closing
1” (25mm) 60 124
• Body of high-quality plastic material 0.1 314
2” (50mm)
• UV-resistant, 73
hence suitable 122outdoor
for 0.2use 800 1
• Light weight
3” (80mm) 104 165 0.6 2000

Application
Underground drip irrigation installations in, for example, garden or landscape irrigation for the discharge of 2
relatively large quantities of air.

PARTS LIST AND SPECIFICATION 3


B
Technical data
No. Part Material
Diameter 3/4” , 1”: ¾" - 1" BSPT 2” male thread 3”
1. Cover Polypropylene Polypropylenethread
: 2” BSPT female
Polypropylene
Option : one-direction air valve 4
2. Seal BUNA-N E.P.D.M. E.P.D.M.
Passage : ¾” -1”: 314 mm²
3. Float
: 2”: 800 mm² Polypropylene Reinforced Nylon Reinforced Nylon
Working pressure
4. Body : 0.2 - Reinforced
Polypropylene 10 bar Nylon Reinforced Nylon
Maximum peak5. temperature
Disc - : 95 °C (with decreasing
Reinforced maximum
Nylon Reinforced pressure)
Nylon
Material : polypropylene (¾” - 1”)
: glassfibre-reinforced nylon (2”)
Colour : black or grey housing with orange cap
Certification : REACH
A 2"

Pressure loss chart


1
Head loss (mwc)

Air flow (m3/h) 4

10.32

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


Version 17.1
Installation & maintenance

The air & vacuum valve AV-10 is employed in an installation as follows:


• At the highest point in lines (on portals, filters, etc.) to prevent vacuum during emptying
• At the beginning and end of the line to allow air to escape or to admit air during emptying/filling
• With underground drip irrigation, to prevent vacuum and hence the intake of dirt
• Air valves are always installed upright at the highest points and at the beginning and end of the line

Parts list
No. Description Material ¾” - 1” Material 2”
1 Body PP Glassfibre-reinforced nylon
2 Cover PP PP
3 Disc - Glassfibre-reinforced nylon
4 Seal BUNA-N EPDM
5 Float PP Glassfibre-reinforced nylon

Technical drawings

¾” - 1” 2”

A
A

2
2

4
4
B
B B
5
5

3
3

1
1

2” 3/4”, 1”
2”

PARTS LIST AND SPECIFICATION


DIMENSIONS AND WEIGHTS
No. Part Material
3/4” , 1” 2”
Weight Orifice Area (mm2) 1. Body Polypropylene Reinforced Nylon
Kg 2. Cover Polypropylene Polypropylene Nominal Size A B Weight Orifice Area (mm2)
3. Disc - Reinforced Nylon mm mm Kg
0.1 314 4. Seal BUNA-N E.P.D.M
5. Float Polypropylene Reinforced Nylon 20mm 3/4”, 25mm 1” 60 124 0.1 314
0.2 800
50mm 2” 73 122 0.2 800

10.33

AIR DISCHARGE CHART


INFLOW
3
Flow m /h OUTFLOW INFLOW
3
Version 17.1
Automatic air valve S-050 and SG-10
A.R.I.
DIMENSIONS AND WEIGHTS

Dimensions mm
The A.R.I. S-050 is anConnection Weight
industrial plastic air valve suitable for automatically
discharging
A airB trapped in systems
C during
Kg. operation.
mm 2 SG-10 S-050
This100
increases140the capacity
1/8” BSPof the pipe0.3
Female (less resistance),
12 prevents incorrect
measurements and extra wear of i.a. water meters and sprinklers.

The SG 10 has been specially developed for the agricultural sector as a


10 bar version of the S-050.

Characteristics A
• For the discharge of air from pressurised systems
1
• Body of high-quality plastic material
• PARTS
UV-resistant, hence suitable for outdoor use
LIST AND SPECIFICATION
• Light weight 2

No. Part
Application Material 3
C
• Venting of non-drainingReinforced
1. Body installations
Nylon
2. Discharge Outlet Polypropylene 4

3. Rolling Seal E.P.D.M.


Technical data B 5
4. Clamping Stem Reinforced Nylon
5. Float Foamed Polypropylene 6
S-050 (Segev) SG-10
Diameter
6. O-Ring : ½" - 1" BSPT male thread
BUNA-N : ½" - 1" BSPT male thread
Option
7. Base : S-050-B: Brass lower housing
Reinforced Nylon / Brass ASTM B-124
7
: one-direction air valve
8.
Passage Strainer : 12 mm²
Nylon : 12 mm² 8
Working pres. : 0.2 - 16 bar : 0.2 - 10 bar
Bursting pres. : 110 bar (with water hammer) : 70 bar
Max. temp. : 95°C (peak) : 60°C (peak)
Material : Glassfibre-reinforced nylon (50%) : Glassfibre-reinforced nylon (30%)
Colour : black cap : grey cap
Certification : REACH : REACH

Pressure loss chart


S-050

SG-10
Head loss

Air flow h

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make product changes without prior notice. To insure receiving the A.R.I.
10.34
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.
rolling seal into the groove in the body and inserting the float into the two rails on
the sides of the body.
8. While holding the float in this manner, insert the clamping stem(3) into the same Version 17.1
grooveInstallation
as the rolling seal , making sure that the angled extended end of the stem is
& maintenance
inserted first into the groove.
The S-050 automatic air valve is employed in an installation as follows:
9. Push both
• Atthethe float
highestand
pointsstem downward
in pipes (on portals, into
filters,the
etc.)vent body trapped
to discharge until both are sitting
air, particularly if the flow velocity
flush with the body.
drops below the critical value.
• Behind a pump to discharge vapour bubbles formed by the pump.
10. Holding• the clamping
In long stem500
pipes of around (3)- with the thumb, turn the body upside down and
800 metres.
check • to see
Behindthat
anythe float
device that(4)
canand
causeseal (2)bubbles
vapour assembly aretheheld
or allows attached
ingress to as
of air, such thepumps,
body(1).
pressure
reducers, parts that cause turbulence and possible leaking couplings.
11. Screw • theAirbody
valvesback into installed
are always the vent base(6).
upright. In the event of a vacuum, the Segev air valve allow a limited amount
12. Do not forget to open
of air into the service valve after the servicing.
the system.

Parts list S-050


No. Description Material
PARTS SPECIFICATIONS
1 Body Glassfibre-reinforced nylon
NO. DESCRIPTION MATERIALS_____
2 Rolling seal EPDM
1 BODY REINFORCED NYLON
3 Clamping stem Glassfibre-reinforced nylon
2 ROLLING SEAL RUBBER EPDM
4 Float PP foam
3 CLAMPING
5
STEM
O-ring
REINFORCED
BUNA-N
NYLON
4 FLOAT 6 Base FOAMED
Glassfibre-reinforced nylon / brass
7 Filter POLYPROPYLENE
Glassfibre-reinforced nylon
5 O-RING BUNA-N
6 BASE REINFORCED NYLON
/BRASS
7 FILTER REINFORCED NYLON

A.R.I FLOW CONTROL ACCESSORIES


WWW.ARIVALVES.COM

10.35
Version 17.1
Combination air valve D-040, DG-10, DT-040
A.R.I.

The A.R.I. D-040 is a plastic combination air valve suitable for discharging
and admitting both small and large quantities of air. The air valve combines
a large opening (kinetic function) with a small opening (automatic function).
This combination ensures a self-cleaning effect (thus less clogging) and
prevents premature closing.

The DG-10 is the agricultural version of the D-040. It is designed for a lower
pressure and higher capacities. The DT-040 is a combination air valve with integral valve for smaller capacities.

Characteristics
• For the discharge/admission of air from/to irrigation systems
• Body of high-quality plastic material
• UV-resistant, hence suitable for outdoor use

Application
In situations where both a large quantity of air has to be discharged/admitted in a short time or an automatic
function is also necessary.

Technical data

D-040 DG-10 (agricultural) DT-040


Working pressure : 0.2 - 16 bar : 0.1 - 10 bar : 0.2 - 10 bar
Diameter : BSPT male ¾“ - 1” - 2” : BSPT male ¾“ - 1” - 2” : BSPT male ½” - ¾“
Passage large kin. : 100 mm² (¾" - 1") : 100 mm² (¾" - 1”) : 42 mm²
Passage small autom. : 7.8 mm² (¾" - 1") : 7.8 mm² (¾" - 1”) : 5.6 mm²
Passage large kin. : 804 mm² (2”) : 804 mm² (¾" - 1”) : 42 mm²
Passage small autom. : 12 mm² (2”) : 12 mm² (2”) : 5.6 mm²
Discharge connection : ⅜” BSPT fem. (¾“ - 1”) : ⅜” BSPT fem. (¾“ - 1”) : 10 mm
: 1½” BSPT female (2”) : 1½” BSPT female (2”) : -
Temperature : 60°C : 60°C : 60°C
Material : Reinf. nylon (housing) : Reinf. nylon (housing) : Reinf. nylon (housing)
: EPDM (O-ring) : EPDM (O-ring) : EPDM (O-ring)
Colour : black/blue : black/blue : grey/blue/orange
Certification : REACH : REACH : REACH
Option : D-040-B: Brass hous. : - : DT-040-VAC (one-way out)
LP-HT-OUT (6 bar)

10.36
Version 17.1
Air movement chart (kinetic) D-040 / DG-10

Pressure difference
Pressure (bar)
difference (bar)

Air flow
Airflow
Air (m33/3//h)
(m
flow(m h)
h)

Air movement chart (automatic) D-040 / DG-10

Diameters ¾" - 1" Diameter 2"

D-040
D-040
D-040 D-040
D-040
D-040

(bar)
difference (bar)
(bar)
difference (bar)

Pressure difference
Pressure difference

DG-10
DG-10
DG-10 DG-10
DG-10
DG-10
Pressure
Pressure

Air
Air flow
Airflow (m33/3//h)
(m
flow(m h)
h) Air flow
Airflow
Air (m33/3//h)
(m
flow(m h)
h)

Parts list and technical drawing D-040-DG-10


No. Description Material
1 Body Glassfibre-reinforced nylon
2 Drainage elbow PP
3 Seal plug assembly
4 Clamping stem Reinforced nylon
A PARTS LIST AND SPECIFICATION
5 Float Glassfibre-reinforced nylon
1
6 O-ring 2
BUNA-N No. Part Material
7 Base 3 Glassfibre-reinforced nylon
1. Body Reinforced NylonA
4
2. Drainage Elbow Polypropylene 1

3. Seal Plug Assembly 2

C 4. Clamping Stem Reinforced Nylon


3
5
3/4” - 1” 5. Float Foamed Polypropylene
B 4
6. O-Ring BUNA-N
1
7. Base Reinforced Nylon
2
7-01. Base Brass ASTM B124
3 C
5
A.R.I.
A.R.I. FLOW
A.R.I.FLOW CONTROL
FLOWCONTROL
CONTROL
6 ACCESSORIES Ltd.
ACCESSORIESLtd.
ACCESSORIES www.arivalves.com
Ltd. www.arivalves.com ari@ari.co.il
www.arivalves.com ari@ari.co.il Tel:
ari@ari.co.il Tel: 972-4-6761988
Tel:972-4-6761988
972-4-6761988 3/4
Optional Ball valve B Brass ASTM B124
A.R.I. FLOW
A.R.I.FLOW
A.R.I. CONTROL
FLOWCONTROL 7ACCESSORIES
CONTROLACCESSORIES Ltd.
ACCESSORIESLtd. reserves
Ltd.reserves the
reservesthe right
theright totomake
rightto make product
makeproduct changes
product changes without
changeswithout prior
withoutprior notice.
priornotice. To
notice.To insure
Toinsure receiving
insurereceiving
receiving the A.R.I.
theA.R.I.
the A.R.I.
factory. A.R.I.
factory.A.R.I.
factory. FLOW
A.R.I.FLOW CONTROL
FLOWCONTROL ACCESSORIES
CONTROLACCESSORIES
ACCESSORIESLtd.Ltd. shall
Ltd.shall not
shallnot be
notbe held
beheld liable
heldliable for
liablefor any
forany errors.
anyerrors. 4All
errors.All rights
Allrights reserved.
rightsreserved.
reserved.
B 5

2”
6 6
7
7

B
ressure difference (bar)

A 2”

10.37

DIMENSIONS AND WEIGHTS

Nominal Size Dimensions mm Weight Orifice Area (mm2): A


Version 17.1
Air movement chart (kinetic) DT-040 Air movement chart (automatic) DT-040

DT-040
Pressure difference

Pressure difference
Pressure difference

Pressure difference
DIMENSIONS AND WEIGHTS

Mo d e l D i m e n s i o n s mm Weight Area mm 2
A B C Gr. Auto. A/V
1/2” (15 mm) 60 115 11 144 5.6 42
FlowFlow u u FlowFlow u u
3/4” (20 mm) 60 115 11 144 5.6 42

Parts list and technical drawing (DT-040)


1
No. Description Material
1 Cover & shut-off valve Acetal 2

2 Discharge outlet EPDM


3 Flat plug Glassfibre-reinforced
PARTS LIST AND SPECIFICATION PP
3
4 Seat BUNA-N
No. Part Material 4
5 O-ring EPDM
1. Acetal
6 Seal
2. Discharge Outlet PP
E.P.D.M.
5

7 Float
3. Flat Plug Glassfibre-reinforced
Reinforced polypropylene 6
4. Seat PP
BUNA-N
8 Body
5. O-Ring Nylon
E.P.D.M. 7

6. Seal Foamed polypropylene


8
7. Float Reinforced polypropylene
8. Body Nylon

Installation & maintenance

The D-040 combination air valve is employed in an installation as follows:


Pressure difference

Pressure difference

• At the highest points in pipes (on portals, filters, etc.) to discharge trapped air, particularly if the flow velocity
drops below the critical value.
• Behind a pump to discharge vapour bubbles formed by the pump.
• In long pipes of around 500 - 800 metres.
• Behind any device that can cause vapour bubbles or allows the ingress of air, such as pumps, pressure
reducers, parts that cause turbulence and possible leaking couplings.
• Air valves are always installed upright. In the event of a vacuum, the Segev air valves allow a limited
Flow u Flow u
amount of air into the system.

10.38
Version 17.1

Pressure gauges

For the measurement of pressures and vacuums in irrigation systems,


Revaho offers a wide range of pressure gauges with different pressures,
fillings and materials. Pressure gauges are supplied with an air of glycerine
filling (for signal damping) and with ¼” bottom or rear connection.

Application
Measuring of pressures and vacuums at different points in irrigation systems.

Technical data

Diameter : 63 mm
Connection : ¼” bottom or rear connection
Maximum range : -1 to 16 bar
Constant working pres. : 0.75x full range
Cyclic loading : 0.65x full range
Peak load : 1.0x full range
Temperature : -20 °C to 60 °C
Materials : black plastic; glycerine-filled (housing)
: metal; air-filled (housing)
: brass (connection)
: brass (measuring system)
: white plastic (dial face)
: plastic (sight glass)

Installation & maintenance

Installation
• The pressure gauges must be preferably installed upright at points in the system where the pressure is
stable, i.e. not directly before or behind an elbow, T-piece, accessory, etc.
• Use an appropriate wrench for installation.
• After installation, the ‘transport hole’ in the pressure gauge must be pierced or pressed open.
• The pressure gauges are suitable for measuring water and are not intended for applications with aggressive
substances.

10.39
DNL
DURABLE, VERSATILE DRIPPERLINE Version 17.1
NON-LEAKAGE (DNL) VALVES
DNL: Dripline Non Leakage Valve
Netafim
OVERVIEW
Featuring an innovative design, our DNL valves ensure that water always remains in the main dist
The Netafim DNL acts like a spring-loaded non-return valve that closes
intensive pulsed irrigation in greenhouses, nurseries and orchards, as well as sloped irrigation.
when the pressure in the system is relieved. The DNL prevents water from
running back into pipes and draining of pipes that are installed with a slope
FEATURES AND BENEFITS
or at different height, thus preventing differences in delivery.
Automatic shutdown at end of irrigation cycle for
continuous water retention in the main distribution line
Characteristics Automatic shutdown at desired pressure level for
• Faster starting and improved water distribution greater energy savings
• Prevents water flowing back into lower parts Ultrasonic welding of newly improved body for leakage
prevention
Application Dedicated cover for effective subsurface drip irrigation
In pipes installed with a slope (SDI) installations
Innovative design for prevention of drainage into low
areas during sloped irrigation at high inclines

TECHNICAL INFORMATION
Technical data
FLOW RATE MAX. WORKING MIN. OPERATING SHUT-OFF PRESSURE IN
RECOMMENDED RANGE PRESSURE PRESSURE
Closing pressure : see table (L/H) (BAR) (BAR) (BAR)
Working pressure : see table
Maximum capacity : 1400 litres/hour 0-1000 4.0 0.8 0.2 1
0-1000 4.0 1.2 0.4 1
Connection : ½” male thread
0-1000 4.0 1.6 0.6 1
Material : silicone (diaphragm)
0-1000 4.0 2.0 0.8 1

Closing and working pressure Pressure loss


Type Closing Min. working Max. working 0.5
pressure pressure pressure 0.4
(bar) (bar) (bar)
Head loss (bar)

0.3
red 0.2 0.8 4.0
0.2
black 0.4 1.2 4.0
0.1
brown 0.6 1.6 4.0
0
0 200 400 600 800 1000 1200 1400 1600
Flow (l/h)

Installation & maintenance

• In crop sections with a slope where the slope is larger than the closing pressure of the drippers, the DNLs
are installed in the drip irrigation hose so that the remaining slope is not more than the closing pressure of
the drippers (to prevent differences in delivery, only in pressure-compensated and closing drippers).
• If both the distribution pipe and the drip irrigation hose has a slope, position the DNL both behind the
distribution line and in the drip irrigation hose. Not more than 2 DNLs should be installed per drip irrigation
hose.
• When using DNLs, the minimum working pressure must be increased by the resistance of the DNLs.
Ensure that the minimum working pressure is always above the opening pressure of the DNL.
• If the DNL is used in non-pressure-compensated drippers behind the distribution line, this improves the
uniformity of the system. Allowance must be made for a slightly lower delivery behind the DNL
(the resistance over the DNL reduces the working pressure behind the DNL).
• The DNLs can be installed using Tavlit PP socket seals, Tavlit Nutlock couplers or Supreme compression
joints.

10.40
Version 17.1

Pressure regulators
Netafim

The Netafim pressure regulators are simple, fixed pressure regulators for
drip irrigation and sprinkler irrigation installations. If the water withdrawal
does not vary widely (for example in an irrigation set), the Netafim pressure
regulators are very suitable for reducing the working pressure.

Characteristics
• 2 types: In-Line (Low-Flow) and PRV 2000 Series
• Modular design: pressure control units are standard and interchangeable on the different housings (¾” - 3”)
• Different pressure levels, from 0.6 to 4.5 bar (pressure behind the regulator)
• Leak-tight: completely closed units

Application
Control of the pressure in drip irrigation systems and sprinkler irrigation installations and/or irrigation systems

Technical data

Maximum working pressure : 10 bar


Maximum capacity : see table
PRV 2000 control pressure : 0.6 - 0.8 - 1.1 - 1.4 - 1.8 - 2.5 - 3.0 - 3.5 - 4.0 - 4.5 bar
In-Line control pressure (Low-Flow) : 1.1 - 1.4 - 1.8 - 2.5 - 3.0 - 3.5 - 4.0 bar
Material : plastic / brass

PRESSURE REGULATOR
FOR USE IN ALL IRRIGATIONConnection
Type SYSTEMS No. of units Min. capacity Max. capacity Housing
(m³/h) (m³/h) material
In-Line (Low-Flow) ¾” (ID) - 0.05 1.0 Plastic
PRV 2000 ¾”
SpEcIFIcATIONS ¾” x 1” (OD x ID) 1 0.8 4.0 Plastic
PRV
■■ 2000regulating
Sealed 1½” units, field1½” (OD)
replaceable 2
(2000 Series) 1.6 8.0 Plastic
PRV
■■ Built2000
in indicator
2” pops out when proper pressure is4achieved (2000 Series)
2” (ID) 3.2 16.0 Brass
■■ Accurate regulator for Low-Flow application (In-Line Serie)
PRV 2000 2” 2” (ID) 6 4.8 24.0 Brass
■■ For extreme chemical application and lower maximun inlet pressure in mining etc. (In-Line Chemical)
PRV 2000 3” 3” (ID) 10 8.0 40.0 Brass

3⁄4 ” In-Line 3⁄4 ” x 1 (2000) 11⁄2 ” x 2 (2000) 2 ” x 4 (2000) 2 ” x 6 (2000) 3 ” x 10 (2000)

pRESSURE REGULATORS SELEcTION

MAx. FLOw RATE MAx. INLET pRESSURE bOdY MATERIAL


pROdUcT MOdEL MIN. FLOw RATE
M 3/h M 3/h

3/4” In-Line (Low Flow) In-Line 0.05 1.0 10 Plastic, black


3/4” In-Line (Chemical) In-Line 0.05 1.0 4 Plastic, purple
3/4” (1 spring) 2000 0.8 4.5 10 Plastic, black
11⁄2” (2 springs) 2000 1.6 9.0 10 Plastic
2” (4 springs) 2000 3.2 18.0 10 Bronze
10.41
2” (6 springs) 2000 4.8 27.0 10 Bronze
3” (10 springs) 2000 8.0 45.0 10 Bronze

AvAILAbLE REGULATING UNITS FOR 2000 SERIES (OUTLET pRESSURE bAR)


0.2
0.2

H
00 2 4 6 8 10 12
12 14 16
16 18
18 20 22 24 26 28 30 32 34 0 10
10 20
20 30
30 40
40 50
50 60
60

Flowrate
Flow rate (m
3
/h)
(m³/h) Flowrate
Flow rate(m³/h)
(m
3
/h) Version 17.1
Selection and calculation examples

IN-LINE OUTLET PRESSURE VS. FLOW RATE IN-LINE LOW FLOW PRESSURE REGULATOR
Plastic body, corrosion resistant
3.0 barP.R.V. Stainless steel spring
4.5 bar inlet pressure
3.5
3.5
Min. flow rate 50 l/h, max. flow rate 1000 l/h
Inlet and outlet connector 3⁄4 ” female
3.0
3.0
Max. inlet pressure: 10 bar
Outlet pressure (bar)

2.5 barP.R.V.
4.0 bar inlet pressure
2.5
2.5 Spring for drip irrigation: 1.1, 1.4 and 1.8 bar
Outlet pressure (bar)

2.0
2.0 1.8 bar P.R.V. Spring for sprinklers: 2.5 and 3.0 bar
3.5 bar inlet pressure
1.5 1.4 bar P.R.V.
1.5 3.0 bar inlet pressure

1.0
1.0

0.5
0.5 1.1 bar P.R.V.
2.0 bar inlet pressure
0.0
0.0
200
200 400
400 600
600 800
800 1000
1000

Flow rate (l/h)


Flow rate (l/h)
2000 SERIES OUTLET PRESSURE VS. FLOW RATE EXAMPLE: FLOW RATE – OUTPUT PRESSURE
Given flow rate = 14.0 m3/h
45 Required output pressure = 1.4 bar
4.5
4.5
Calculation: Selected product = PRV 2”x 6 springs.
4.0
4.0 40 Headloss across the PRV unit at 14.0 m3/h = 0.12 bar (graph 2).
35 Flow rate per spring = 14:6 = 2.3 m3/h.
3.5
3.5
Selected spring 1.4 = output pressure at 2.3 m3/h is 1.4 bar
Outlet pressure (bar)
Outlet pressure (bar)

30
3.0
3.0 (graph 1).
25 Total minimum required inlet pressure = 1.4 + 0.12 + 0.2 (0.2
2.5
2.5
20 bar is constant addition to move the piston out) = 1.72 bar.
2.0
2.0
18 Spring pressure regulator valve = > head loss + actual output
1.5 14 pressure + 0.2 bar = minimum required inlet pressure.
1.5
11
1.0
1.0 8
6
0.5
0.5

0.0
0.0
10001500
1000 1500 250
25000 3500
3500 4500
4500
Flow rate(l/h)
Flow rate (l/h)

PRESSURE REGULATORS (HEAD LOSS VS. FLOW RATE)

0.8
0.8
3”X10 (HEAD LOSS VS. FLOW RATE)
(bar)

0.6
(bar)

0.6
ts

0.6
loss(bar)

(bar)

0.6
uni
nit

its

its
u

loss
un

n
”- 2

0.4 6u
¾”- 1

0.4
Headloss

Headloss
-4

-
2”

2”
Head

Head

0.2
0.2
0.2
0.2

00 2 4 6 8 10 12
12 14 16
16 18
18 20 22 24 26 28 30 32 34 0 10
10 20
20 30
30 40
40 50
50 60
60

Flowrate
Flow rate (m
/h)
3
(m³/h) Flowrate
Flow rate(m³/h)
(m
3
/h)

Installation & maintenance

Installation IN-LINE LOW FLOW PRESSURE REGULATOR


IN-LINEregulators
• Pressure OUTLET PRESSURE
can beVS. FLOW RATE
installed both horizontally Plastic
and vertically.
body, corrosion resistant
• The control units cannot be opened,
3.0 barP.R.V.
but can be interchanged, also spring
Stainless steel with the older type.
4.5 bar inlet pressure
3.5
3.5
Min. flow rate 50 l/h, max. flow rate 1000 l/h
10.42 Inlet and outlet connector 3⁄4 ” female
3.0
3.0
Max. inlet pressure: 10 bar
t pressure (bar)

2.5 barP.R.V.
4.0 bar inlet pressure
2.5
2.5 Spring for drip irrigation: 1.1, 1.4 and 1.8 bar
ressure (bar)

2.0
2.0 1.8 bar P.R.V. Spring for sprinklers: 2.5 and 3.0 bar
3.5 bar inlet pressure
1.5 1.4 bar P.R.V.
1.5
Version 17.1

Flushing valves
Amiad

The Amiad flushing valve is installed at the end of a drip irrigation hose
to discharge air more quickly and to prevent the possible accumulation
of contaminants at the end of the hose without flushing valves
or automation systems being necessary.

In pressure-free state, the valves are open and the water can drain
from the hose. As soon as the hose is pressurised, the valve closes
and drip irrigation is possible.

Characteristics
• Two types with different closing pressure: Closing at 3 or 5 mwc

Technical data

Connection : 12, 16, 20, 25 mm, ¾” BSP


Closing pressure : 3 mwc (red/black)
: 5 mwc (black/black)

Installation & maintenance

• Install the valves at the lowest point in the hose to prevent the drawing in of contaminants.

10.43
Version 17.1

Quick-Valve

The Quick-Valve is a small ebb and flow valve for fixed and mobile panels
that allows water to be easily supplied and quickly discharged.
The valve is designed with a separate drainage system that operates on
the syphon principle. Feed and discharge flows thus remain separate.

Characteristics
• Automatic oxidation of fertilisers during the filling of the ebb and flow
panels using the venturi effect of the syphon by which air is drawn in
• Possibility of regulating the filling speed by means of different hole sizes (can be bored individually as an
option)
• Reliable operation as there are no freely moving parts

Technical data

Filling capacity : see table


Passage opening : 4 mm (standard), can be bored out to 10 mm (do this in steps)
Discharge capacity : approx. 28 litres/min.
Feed connection : gland fitting 8-12 mm
Discharge connection : 20 mm OD (16 mm ID)
Mounting hole diameter : 27 mm
Feed recommendation : LDPE hose 12x10 mm
Discharge recommendation : Tricoflex or Torsino ¾”

Quick-Valve filling capacity (l/min) with passage opening (mm)*


Pres- 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
sure
(bar)
1.0 9.2 10.5 12.8 15.2 16.7 18.5 19.7 21.2 21.4 22.1 22.4 23.5 26.2
1.5 11.4 12.8 16.2 19.1 21.6 23.2 24.9 26.6 26.8 27.5 29.4 32.2
2.0 12.6 14.2 16.7 21.6 24.7 26.7 28.7 29.5 31.5 32.6 33.3
2.5 14.2 15.7 19.4 23.5 27.4 30.1 32.5 33.7 35.3 36.0
3.0 15.1 17.6 20.6 24.7 29.5 32.4 35.4 36.3 38.8
3.5 16.4 18.4 21.7 26.1 31.2 33.8 38.0 40.0
4.0 16.6 19.1 23.0 27.5 32.5 36.4 39.1

* The supplied gland fitting is sufficient up to a passage opening of 6 mm, for larger passage openings we recommend the
use of a larger feed hose.

Working principle
Irrigation table
(27 mm bore hole)

Quick valve
3/4” Tricoflex / Torsino hose
for drainage

Supply tube

Discharge pipe

Supply pipe
10.44
Version 17.1

HS Valve

The HS valve has been specially developed for the filling and draining of
ebb and flow panels. By contrast with the Quick-Valve, the feed and
discharge flows are combined (see working principle).
During filling, the water flows through a small hole in the internal cone,
reducing the water flow and the water level can gradually rise.
During discharge, the cone drops back into the valve, thus creating a
larger discharge opening.

The passage opening can be reamed to achieve a higher filling capacity. A larger feed/discharge hose should be
used to achieve a higher discharge capacity.

Characteristics
• Reamable to 6 mm bore
• Equipped with a filtration cap
• Equipped with a ball valve so that each panel can be shut off separately
• Various connection possibilities

Technical data

Filling capacity : see table


Passage opening : 3.5 mm (standard), can be bored out to 6 mm (do this in steps)
Discharge capacity : see table
Connection (feed/discharge) : plug connector for LDPE hose 8 x 6 mm / 10 x 8 mm / 12 x 10 mm
Mounting hole diameter : 27 mm
Feed/discharge recommendation : LDPE hose 12x10 mm (for larger capacities Tricoflex or Torsino ¾”)

HS valve filling capacity (l/min) Discharge capacity (l/min)


Passage opening (mm) Inlet/discharge inside diameter (mm)
Pres- 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.0 8.0 9.0 10.0
sure
(bar)
1.5 2.32 4.14 5.80 8.10 10.40 11.75 15.05 17.15 18.75 1.7 3.5 5.0 6.0
2.0 2.40 4.42 6.24 9.00 11.60 14.30 17.15 19.50 21.35 * hose length of 1.5 m
2.5 2.55 4.72 6.68 9.68 12.20 15.95 18.75 21.75 24.15
3.0 2.65 4.85 6.85 10.00 12.90 17.15 19.75 22.70 27.30
3.5 2.85 5.05 7.25 10.50 13.70 18.15 21.00 24.35 28.85
4.0 2.95 5.35 7.65 11.50 14.60 19.35 22.35 25.75 31.25

Working principle

Irrigation table
(27 mm bore hole)

HS-valve

3/4” Tricoflex / Torsino slang


for supply and drainage

Supply and drainage pipe

10.45
Version 17.1

Syphon valve

The syphon valve drains the irrigation water from a roller container.
The drainage torque can be set by adjusting the head
of the syphon valve. If the head is in the highest position, the syphon
effect does not occur and the water remains in the panel.
If the head is completely removed, the water drains directly from the
panel. Filling of the roller container takes place via a separate inlet.

Characteristics
• Possibility of drainage by means of a syphon at 3 levels
• Specially developed for mobile roller container systems and various types of panel
• Several syphon valves can be installed per panel
• Possibility of regulating the drainage rate
• Easy to clean

Technical data

Connections : 1” clamping ring


Discharge capacity : see chart
Mounting hole diameter : 27 mm
Pressure losses : see chart

Discharge capacity
Draining capacity diagram for the Siphon valve (Litres/Min)

Vertical height (cmwc)

17,5

14

12

10

l/min.
1 2 3 4 5.26 6.9 8 8 9.0 9
l/min.

Hole diameter in valve cone (mm)

10.46
Version 17.1

NR-020 non-return valve (no longer available)


A.R.I.

This product has been replaced by the new NR-010 non-return valve line.

The A.R.I. NR-020 is a plastic, spring-loaded disc check valve.


Non-return valves are used to prevent water from flowing back.
This non-return valve is made of high-quality plastic and stainless steel
with the rotating parts mounted in bearings to reduce wear during
continuous operation. The disc leaves a large free passage in the
open position. Together with the stainless steel bearings of the shaft, this ensures minimum pressure losses
(important for installation in intake lines). The NR-020 is spring-loaded: The 3” and 4” valves close without
counterpressure. The plastic construction allows use with corrosive media, such as in irrigation systems.
The Regev is installed between flanges.

Application
• Behind pumps installed in parallel to prevent water flowing back when one or more pumps is not in use.
• Before the pump if several tanks are connected to one intake line, or of several intake lines and/or pumps
are connected together.
• Behind the pump to prevent systems from running dry. Particularly with pipes above ground, this prevents
air from entering the pipe and/or a vacuum being created.
• Behind the pump (e.g. SAF filter) to prevent damage caused by water hammer.
• Finally we find non-return valves also in automatic flushing systems where they replace electric valves.

Technical data

Diameters : 3”, 4”, 6”, 8”


Pressure loss : see pressure loss chart
Max. pressure : 10-16 bar
Min. pressure : 0 bar (3” and 4”, closing without back-pressure)
: 0.2 bar (6” and 8”)
Max. temp. : 95°C (with decreasing pressure)
Material : glassfibre-reinforced nylon (3”, 4” and 6” housing)
: hard-anodised aluminium (8” housing)
: EPDM (seal)
Option : NR-020 with/without position indicator
: NR-020LS with limit switch for open/closed signal
: NR-020FV incl. foot valve with suction strainer

Pressure loss