REVISION LOG
• A - January 2021
MODELS AFFECTED
• Boom Lifts
• Scissor Lifts
• Telehandlers
REQUIRED TOOLS
• Standard Mechanic Tools
REQUIRED PERSONNEL
• Qualified Equipment Mechanic
PROHIBITED OPTIONS/ITEMS
• None
REQUIRED OPTIONS/ITEMS
• PC or Laptop
(Minimum Specifications: Windows 98SE, Pentium II)
• Software Cable Kit (PN 1001137005)
Note: Software cable kit includes USB/RS232 cable. Refer to kit
instruction 3121417_A before connecting USB/RS232 cable to
PC or laptop.
31212166 1
PC Analyzer Installation Instructions
SOFTWARE DOWNLOADING
Sales & Service Welcome JLG User 0
Control Software
Analyzer Software
Equipment Information
KAE6490
KAE6500
Note: The PC Analyzer Software has “.exe” file extension and its
icon looks like the figure shown above.
Online Express
Online Express
KAE6470
Password *
KAE6480
2 31212166
PC Analyzer Installation Instructions
PC Analyzer 0.5
COM3
COM5
Esc Ent
Esc Ent
KAE6520
KAE6510 6. Click the utility’s COM Port drop-down and make the
proper selection for the RS-232 or USB port that is
1. Open the PC Analyzer software in PC or laptop. The connected to the vehicle.
initial screen appearance of PC Analyzer is shown in
figure above. Note: Before connecting the USB/RS232 cable to machine,
check for the available COM port selections. Once USB/RS232
cable is connected, select the COM port which appears. Do Not
select the COM port which was previously available before
A USB/RS232 cable was connected to machine.
Note: Refer to appropriate service manual to locate analyzer 7. The PC analyzer screen should appear similar to the
connection point on the machine. screen on handheld analyzer.
4. For Mobile Elevated Work Platforms (MEWPs): 8. Click on the buttons on the PC analyzer screen or use the
Turn key to “Ground Position” or “Platform Position” and arrow keys, Esc key, Enter key and numeric keys on the
pull out power/emergency stop switch (up) to power the PC or laptop’s keyboard to navigate through the PC
machine control system. analyzer menus.
5. For Telehandlers: Turn the ignition key to position 1 in 9. Enter access level code in PC analyzer using numeric
key switch to power the machine control system. keys on the PC or laptop’s keyboard.
10. After use, disconnect USB/RS232 cable from the analyzer
port on the machine and close the PC analyzer software.
31212166 3
PC Analyzer Installation Instructions
NOTICE Format:
Starting Point:
Text
Operator Root Current Location
P7.34 software. But the standard analyzer function is not 2. Export pop-up window will appear.
affected. This issue is corrected in P7.35 and later releases.
Please update your machine to the latest software to 3. In the “Filename” tab, give the desired file name to the
text file.
correct this issue.
4. In the “Save” tab, browse and select the folder location
to save the file.
PC Analyzer 0.5
5. Select the “Format” as “Text”.
Export 6. Depending upon the requirement, select the “Starting
Point” either as “Operator Root or “Current Location”.
• If “Operator Root” option is selected, the export log
will only retrieve “Operator Access” level parameters.
• Select the “Current Location” option to record menus
below the “Operator Access” or “Level 2” access, such
as “Service” or “Level 1”. For this option enter the
password in “Access Level” menu before clicking on
“Export”.
Esc Ent
7. Once all the options are selected, click on “OK”.
Done!
OK
KAE6570