PC Analyzer Installation Instructions

31212166
An Oshkosh Corporation Company

These instructions describe the downloading and operating MACHINE PREPARATION


procedures for PC Analyzer.
1. Park machine on a firm level surface, fully retract boom if
The main purpose of JLG PC Analyzer is to have an alternative applicable, lower boom and/or platform, and shut the
tool to the JLG Handheld Analyzer. machine OFF.

JLG PC Analyzer also functions as a “LogLifter” which records


all the information which are viewable in the analyzer's
menus into a text file. NOTICE
Read these instructions thoroughly before beginning the There is a known issue with LogLifter functionality on
procedure. 1200SJP and 1350SJP models, where not all of the analyzer
menu is recorded when machine is running P7.25 through
P7.34 software. But the standard analyzer function is not
CAUTION affected. This issue is corrected in P7.35 and later releases.
Please update your machine to the latest software to
Use all applicable safety precautions while working on, correct this issue.
around, or under any machinery.

REVISION LOG
• A - January 2021
MODELS AFFECTED
• Boom Lifts
• Scissor Lifts
• Telehandlers
REQUIRED TOOLS
• Standard Mechanic Tools
REQUIRED PERSONNEL
• Qualified Equipment Mechanic
PROHIBITED OPTIONS/ITEMS
• None
REQUIRED OPTIONS/ITEMS
• PC or Laptop
(Minimum Specifications: Windows 98SE, Pentium II)
• Software Cable Kit (PN 1001137005)
Note: Software cable kit includes USB/RS232 cable. Refer to kit
instruction 3121417_A before connecting USB/RS232 cable to
PC or laptop.

31212166 1
PC Analyzer Installation Instructions

SOFTWARE DOWNLOADING
Sales & Service Welcome JLG User 0

Parts Service Fleet Solutions Warranty / Safety Training My Account Resources

Control Software

Analyzer Software

Equipment Information

Inspection and Forms

Standard Repair Procedures

Search by part number SEARCH

KAE6490

6. Click on “Service” tab and then select “Analyzer Software”


from the drop-down.
7. Save and install the software in the PC or laptop.

KAE6500

Note: The PC Analyzer Software has “.exe” file extension and its
icon looks like the figure shown above.
Online Express
Online Express

KAE6470

1. Open the available Internet browser in the PC or laptop.


2. Go to JLG homepage by entering www.jlg.com in the
search window.
OR
Click on the following link:
https://onlineexpress.jlg.com/service/machine-analyzer-
software
3. Click on “Online Express” to open Online Express page.

Sales & Service Sign In 0

Parts Email Address *


Fleet Solutions Training Resources

Password *

SIGN IN Forgot Password?

REGISTER FOR AN ACCOUNT

Search by part number SEARCH

KAE6480

4. Enter registered “E-mail ID” and “Password”, then click on


“Sign In”.
5. If do not have registered ID and password, click on
“Register for an Account” to create a new ID.

2 31212166
PC Analyzer Installation Instructions

OPERATING PROCEDURE PC Analyzer 0.5

PC Analyzer 0.5
COM3
COM5

Esc Ent
Esc Ent

KAE6520

KAE6510 6. Click the utility’s COM Port drop-down and make the
proper selection for the RS-232 or USB port that is
1. Open the PC Analyzer software in PC or laptop. The connected to the vehicle.
initial screen appearance of PC Analyzer is shown in
figure above. Note: Before connecting the USB/RS232 cable to machine,
check for the available COM port selections. Once USB/RS232
cable is connected, select the COM port which appears. Do Not
select the COM port which was previously available before
A USB/RS232 cable was connected to machine.

PC Analyzer 0.5 PC Analyzer 0.5

MENU: ACCESS LEVEL:


HELP:PRESS ENTER CODE 00000
OR

Esc Ent Esc Ent


KAF22700

2. Connect USB end of USB/RS232 cable (A) to PC or


laptop’s USB port.
3. Connect the other end of USB/RS232 cable (A) to the
analyzer port of ground control box or platform control
box. KAE6530

Note: Refer to appropriate service manual to locate analyzer 7. The PC analyzer screen should appear similar to the
connection point on the machine. screen on handheld analyzer.
4. For Mobile Elevated Work Platforms (MEWPs): 8. Click on the buttons on the PC analyzer screen or use the
Turn key to “Ground Position” or “Platform Position” and arrow keys, Esc key, Enter key and numeric keys on the
pull out power/emergency stop switch (up) to power the PC or laptop’s keyboard to navigate through the PC
machine control system. analyzer menus.
5. For Telehandlers: Turn the ignition key to position 1 in 9. Enter access level code in PC analyzer using numeric
key switch to power the machine control system. keys on the PC or laptop’s keyboard.
10. After use, disconnect USB/RS232 cable from the analyzer
port on the machine and close the PC analyzer software.

31212166 3
PC Analyzer Installation Instructions

PC ANALYZER AS LOGLIFTER Export


PC Analyzer software can also be used as a “LogLifter” which
Filename:
records all of the information viewable in the analyzer's
JLG_2020-10-14_7-53-57AM
menus into a text file.
Save:
H:\CSE\PCAnalyzer Browse

NOTICE Format:
Starting Point:
Text
Operator Root Current Location

There is a known issue with LogLifter functionality on Cancel OK

1200SJP and 1350SJP models, where not all of the analyzer


menu is recorded when machine is running P7.25 through KAE6550

P7.34 software. But the standard analyzer function is not 2. Export pop-up window will appear.
affected. This issue is corrected in P7.35 and later releases.
Please update your machine to the latest software to 3. In the “Filename” tab, give the desired file name to the
text file.
correct this issue.
4. In the “Save” tab, browse and select the folder location
to save the file.
PC Analyzer 0.5
5. Select the “Format” as “Text”.
Export 6. Depending upon the requirement, select the “Starting
Point” either as “Operator Root or “Current Location”.
• If “Operator Root” option is selected, the export log
will only retrieve “Operator Access” level parameters.
• Select the “Current Location” option to record menus
below the “Operator Access” or “Level 2” access, such
as “Service” or “Level 1”. For this option enter the
password in “Access Level” menu before clicking on
“Export”.
Esc Ent
7. Once all the options are selected, click on “OK”.

Writing to: H:\CSE\PCAnalyzer\ADE2_600S_Service.txt


KAE6540

1. Click on the file folder icon drop-down, then select


“Export”. KAE6560

8. Once export is initiated, a pop-up window appears


showing the progress of export. Wait for a couple of
minutes while the log file is being created.

Done!

Done writing to: H:\CSE\PCAnalyzer\ADE2_600S_Service.txt

OK

KAE6570

9. Once log file is created, a pop-up window appears to


indicate that the log file is saved in the folder location.
10. Click on “OK” to close the pop-up window.