You are on page 1of 2

OPERATING

CHANGING THE SETPOINT MANUAL DEFROST CYCLE


THE THERMOGUARD
µP-T 1. Press the On Key to turn the unit on. 1. Press the On Key to turn the unit on.

MICROPROCESSOR 2. Press the Up and Down Arrow keys to


chose the new setpoint.
2. Press the Defrost Key.

3. The Defrost Icon will appear and the unit


3. Press the Enter key. The display will will enter a defrost cycle. The defrost cycle
THERMO KING THERMOGUARD briefly show [Lod], and then the new setpoint will terminate automatically.
will reappear.
ZONE
1234
SELECTING CYCLE SENTRY OR VIEWING PROMPT & DISPLAY
CONTINUOUS MODE SCREENS

1. Press the On Key to turn the unit on. 1. Press the On Key to turn the unit on.
Truck Smart Reefer Units are
o p e ra t e d b y a R e m o t e C o n t ro l 2. Press the Select key to display [CYCLS] 2. Press the Select key to view the prompt
and [YES] or [nO]. and display screens as follows:
Panel. This panel may be located in
the truck cab or mounted on the 3. Press the Up or Down Arrow key to [Alr] Alarm codes if any
truck box. select the desired mode. [YES] = Cycle [CYCLS] Cycle Sentry prompt
Sentry, [nO] = Continuous. [dIS] Discharge air temperature
Used on: [coL] Evap coil temperature
4. Press the Enter key. The display will [tLH] Total unit hours
briefly show [Lod], and then the new mode [EnH] Diesel engine hours
TD-II Smart Reefer Truck Units will reappear. [ELH] Electric hours
[Hr4] Hourmeter 4 if enabled
RD-II Smart Reefer Truck Units STARTING THE ENGINE [Hr5] Hourmeter 5 if enabled
[Hr6] Hourmeter 6 if enabled
1. Press the On key to turn the unit on. If [oIL] Engine oil pressure
KD-II Smart Reefer Truck Units [EnT] Engine coolant temperature
no other key is pressed, the engine will
automatically preheat and start in about 10 [rPn] Engine RPM
MD-II Smart Reefer Truck Units seconds. CAUTION: The engine starts [bAt] Battery voltage
automatically in either Cycle Sentry or [bLIt] Display backlight select
Continuous mode. [dFI] Initial defrost interval
TK 41237 16 April 1997 [ddr] Defrost duration
ELECTRIC MODE OPERATION ALARM CODES RUNNING A UNIT SELF CHECK

1. Units equipped with the Electric Standby 00 No fault 1. Press the On Key to turn the unit on.
option will automatically switch to Electric 02 Evaporator coil sensor
Mode operation any time the unit is 03 Return air sensor 2. Clear any alarm codes that may exist.
connected to a source of Standby Power, 04 Discharge air sensor
the Standby Power source is energized and 06 Engine water temp sensor 3. Press and hold the Thermo King Logo
07 Engine RPM sensor key for at least 3 seconds. The Unit Self
the unit is turned on.
09 High evaporator temp
Check prompt screen will appear.
10 High discharge pressure
2. The unit will operate in either Continuous
11 Unit controlling on discharge air sensor
or Cycle Sentry mode as selected. 12 Sensor shutdown
4. Press the Enter key to start a Unit Self
17 Engine failed to crank Check test. The display will briefly show
18 High engine water temp [Lod] and the test will begin.
VIEWING & CLEARING ALARM 19 Low engine oil pressure
CODES 20 Engine failed to start 5. The test is fully automatic. When
21 Cooling cycle check complete, [PASS], [CHEC] or [FAIL] will
22 Heating cycle check appear on the display. The unit will continue
1. Press the On Key to turn the unit on.
23 Cooling cycle fault to control to setpoint.
24 Heating cycle fault
2. If the Alarm Icon is "on", alarm conditions
25 Alternator check
have been detected
28 Unit Self Check abort ADDITIONAL INFORMATION
31 Oil pressure sensor
3. Press the Select key. The Alarm Screen 32 Refrigeration capacity low
and alarm code will appear. If more than For additional information consult the
33 Check engine RPM
one alarm is present, each will be displayed following Thermo King manuals for your
35 Run Relay circuit
for several seconds. Always record any unit.
36 Electric motor failed to run
alarm codes shown. They are invaluable to 37 Check engine water level
the service technician. 38 Electric phase reversed Operating Manual
40 High speed circuit
4. After the alarm condition has been 52 Heat circuit Maintenance Manual
corrected, press the Select key to display 54 Test Mode timeout
the alarm code. When the alarm code is 61 Battery check Parts Manual
shown in the display, press the Enter key to 63 Engine stopped - reason unknown
clear the alarm. 66 Low engine oil level Diagnosis Manual - TK 41017
70 Hourmeters exceed 99999
71 Hourmeter 4 exceeds set limit
72 Hourmeter 5 exceeds set limit
73 Hourmeter 6 exceeds set limit
74 Micro reverted to default settings
77 Internal fault code, dealer resettable