You are on page 1of 2

DRW170775AA

Specifications Dimensions (unit: mm)


TC4 Series TC4S Series TC4SP Series 6 TC4W Series
72.2
Series
TEMPERATURE CONTROLLER Power AC power
TC4S TC4SP
100-240VACᜠ 50/60Hz
TC4Y TC4M TC4W TC4H TC4L 48 6 64.5 48 58.5 45 96 6 64.5

TC4 Series
supply AC/DC Power 24VACᜠ 50/60Hz, 24-48VDCᜡ
Allowable voltage range 90 to 110% of rated voltage
Power AC power Max. 5VA (100-240VAC 50/60Hz)

44.7
45

48
INSTRUCTION MANUAL consumption AC/DC Power
Display method
Max. 5VA (24VAC 50/60Hz), Max. 3W (24-48VDC)
7Segment (Red), Other display (Green, Yellow, Red LED)
Character size (W×H) 7.0×15.0mm 7.4×15.0mm 9.5×20.0mm 9.5×20.0mm 7.0×14.6mm 11.0×22.0mm
Input RTD DPt100Ω, Cu50Ω (Allowable line resistance max.5Ω per a wire)
TC4Y Series 84
type TC K (CA), J (IC), L (IC)
At room temperature (23℃±5℃): (PV ±0.5% or ±1℃, select the higher one) ±1digit 72 7 77
Display RTD
Out of room temperature range: (PV ±0.5% or ±2℃, select the higher one) ±1digit
accuracy※1
TC ※ For TC4SP, add ±1℃ by accuracy standard.
Control Relay 250VACᜠ 3A 1a TC4H Series TC4L Series

36

30
output SSR 12VDCᜡ ± 2V 20mA Max.
48 6 64.5 96 6 64.5
Alarm output AL1, AL2 Relay: 250VACᜠ 1A 1a (※TC4SP, TC4Y have AL1 only.)
Control method ON/OFF and P, PI, PD, PID control
TC4M Series
Hysteresis 1 to100℃/℉ (0.1 to 50.0℃/℉) variable
72 6 64.5
Proportional band (P) 0.1 to 999.9℃/℉
Integral time (I) 0 to 9999 sec.
Derivative time (D) 0 to 9999 sec.
Control period (T) 0.5 to 120.0 sec.

91.5

91.5
96
Manual reset 0.0 to 100.0%

67.5
Thank you for choosing our Autonics product. Sampling period 100ms
Dielectric AC power 2,000VAC 50/60Hz for 1min. (between input terminal and power terminal)
Please read the following safety considerations before use. strength AC/DC Power 1,000VAC 50/60Hz for 1min. (between input terminal and power terminal)
Vibration 0.75mm amplitude at frequency of 5 to 55Hz in each X, Y, Z direction for 2 hours
Mechanical OUT: Min. 5,000,000 operations, AL1/2: Min. 5,000,000 operations
Relay
Safety Considerations life cycle Electrical
OUT: Min. 200,000 operations (250VAC 3A resistive load),
AL1/2: Min. 300,000 operations (250VAC 1A resistive load) Bracket Panel cut-out Terminal cover (sold separately)
Insulation resistance Min. 100MΩ (at 500VDC megger) TC4S/TC4SP Series TC4Y Series RSA-COVER (48×48mm) RMA-COVER (72×72mm)
※Please observe all safety considerations for safe and proper product operation to avoid hazards.
Noise immunity Square-wave noise by noise simulator (pulse width 1㎲) ± 2KV R-phase and S-phase 30 48.4 70 3
A
※Safety considerations are categorized as follows. Memory retention Approx. 10 years (When using non-volatile semiconductor memory type) 31
Warning Failure to follow these instructions may result in serious injury or death. 48.6 20

12
10
Environ Ambient temp. -10 to 50℃, Storage: -20 to 60℃
45 5

41.5
Caution Failure to follow these instructions may result in personal injury or product damage. -ment Ambient humi. 35 to 85%RH, Storage: 35 to 85%RH 60

68.5

64
※The symbols used on the product and instruction manual represent the following Double insulation or reinforced insulation (mark: , Dielectric strength between the
Insulation type
measuring input part and the power part: AC power 2kV, AC/DC Power 1kV)

B
symbol represents caution due to special circumstances in which hazards may occur.

10
C
Approval

44.9

18
22
36

16

4.4
Approx. 141g Approx. 123g Approx. 174g Approx. 204g Approx. 194g Approx. 194g Approx. 254g
Warning

3.5
※2
Weight 9.8

13
(approx. 94g) (approx. 76g) (approx. 85g) (approx. 133g) (approx. 122g) (approx. 122g) (approx. 155g)
1. F ail-safe device must be installed when using the unit with machinery that may cause serious injury ※1: Thermocouple L (IC) type, RTD Cu50Ω TC4M, TC4W, TC4H, TC4L Series 22.5
or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, At room temperature (23℃ ±5℃): (PV ±0.5% or ±2℃, select the higher one) ±1digit 15 Size
A B C D RHA-COVER RLA-COVER (96×96mm )

3.3
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Out of room temperature range: (PV ±0.5% or ±3℃, select the higher one) ±1digit 55 21 Model
Failure to follow this instruction may result in fire, personal injury, or economic loss. (48×96mm, 96×48mm )
In case of TC4SP Series, ±1℃ will be added. 47.2 4 94 3
2. Install on a device panel to use. TC4S Min. 65 Min. 65 45 +0.6
45 +0.6

※2: The weight includes packaging. The weight in parentheses is for unit only. 0 0

Failure to follow this instruction may result in electric shock or fire. ※Environment resistance is rated at no freezing or condensation. TC4SP Min. 65 Min. 65 45+0.6 45+0.6

4
46 0 0
3. D o not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or fire.
4. C heck 'Connections' before wiring.
Unit Description TC4Y Min. 91 Min. 40 68+0.7
0 31.5+0.5
0

91.5

91.5
TC4M Min. 90 Min. 90 68+0.7 68+0.7

37.5
56

86

86
40.5
0 0
Failure to follow this instruction may result in fire. 1
5. D o not disassemble or modify the unit. TC4H Min. 65 Min. 115 45+0.6
0 92+0.8
0

Failure to follow this instruction may result in electric shock or fire. 1 TC4W Min. 115 Min. 65 92+0.8
0 45+0.6
0

3 2 6 7, 8 12
4 TC4L Min. 115 Min. 115 92+0.8 92+0.8
Caution 2 5
0 0

23.9

13

13
8
1. When
 connecting the power input and relay output, use AWG 20(0.50mm2) cable or over and tighten 6
the terminal screw with a tightening torque of 0.74~0.90N.m. 7
When connecting the sensor input and communication cable without dedicated cable, use AWG 3 5 4
Connections SSR Drive Output Selection Function (SSRP Function)[SSrM]
28~16 cable and tighten the terminal screw with a tightening torque of 0.74~0.90N.m. 1. Present temperature (PV) display 5. Control/alarm output indicator
※TC4 Series has selectable control output; Relay output, and SSR drive output.
Failure to follow this instruction may result in fire or malfunction due to contact failure. RUN mode: Present temperature (PV) display. OUT: It will turn ON when control output (Main Control ● SSRP function is selectable one of standard ON/OFF control, cycle control, phase control by utilizing
2. U
 se the unit within the rated specifications. Parameter setting mode: Parameter or Output) is ON. AC/DC power type does not have SSRP function. standard SSR drive output.
Failure to follow this instruction may result in fire or product damage. parameter setting valuedisplay. ※In case of CYCLE/PHASE control of SSR drive TC4S Series TC4SP Series ● Realizing high accuracy and cost effective temperature control as linear output(cycle control and
3. U
 se dry cloth to clean the unit, and do not use water or organic solvent. output, it will turn ON when MV is over 3.0%. 6 phase control).
2. Deviation indicator, Auto-tuning indicator SSR OUT: 1 AL1 OUT: 7 -
Failure to follow this instruction may result in electric shock or fire. (only for AC power type) 12VDC ±2V 5 7 AL1 OUT:
● Select one of standard ON/OFF control [STND], cycle control [CYCL] , phase control [PHAS] at [SSrM]
It shows current temperature (PV) deviation 20mA Max
250VAC 1A 1a Relay OUT 250VAC 1A 1a
4. D
 o not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, AL1/AL2: It will light up when alarm output Alarm1/ 2 8
based on set temperature (SV) by LED. AL2 OUT: 250VAC 3A 1a
4 8
+ parameter of Parameter group 2. For cycle control, connect zero cross turn-on SSR or random
radiant heat, vibration, impact, or salinity may be present. Alarm2 are on. 250VAC 1A 1a
No. PV deviation temp. Deviation display 3 9 SSR OUT: turn-on SSR. For phase control, connect random turn-on SSR.
Failure to follow this instruction may result in fire or explosion. 6. key Relay OUT: TC RTD B' 12VDC ±2V
3 9
5. K
 eep metal chip, dust, and wire residue from flowing into the unit. 1 Over 2℃ indicator ON 4 250VAC 3A 1a
10
B' RTD TC
- 20mA Max
Used when entering into parameter group, returning - Temperature controller SSR voltage output
Failure to follow this instruction may result in fire or product damage. 2 Below ±2℃ indicator ON + B SSR module
to RUN mode, moving parameter, and saving setting B + 2 10 - (TC4Series) (12VDC)
-
5 11 Load
3 Under -2℃ indicator ON values. A +
+ A 1 11 ※1

Ordering Information 6 12
※1 SENSOR SOURCE
The deviation indicators ( , , ) flash by 7. Adjustment SOURCE SENSOR
100-240VAC 5VA 50/60Hz
100-240VAC 5VA 50/60Hz
every 1 sec. when operating auto tuning. Used when entering into set value change mode, digit 24VAC 5VA 50/60Hz 24VAC 5VA 50/60Hz
24-48VDC 3W 24-48VDC 3W
T C 4 S 1 4 R moving and digit up/down.
3. Set temperature (SV) indicator TC4Y Series TC4H, TC4W, TC4L Series
Press any front key once to check or change 8. FUNCTION key
Control output N Indicator - Without control output current set temperature (SV), the set Press + keys for 3 sec. to operate function (RUN/ AL1 OUT: Relay OUT: 1 13
250VAC 1A 1a 250VAC 3A 1a Power
R Relay output+SSR drive output※1 temperature (SV) indicator is ON and preset set STOP, alarm output cancel, auto-tunning) set in inner
2 14 100-240VAC
value is flashed. parameter [DI-K]. 50/60Hz
Power supply 2 24VAC 50/60Hz, 24-48VDC 1 2 3 4 5 6 7 8 9 10 11
4. Temperature unit (℃/℉) indicator ※Press + keys at the same time in set value 3 15
4 100-240VAC 50/60Hz A B B' -+
It shows current temperature unit. operation to move digit.
RTD SSR OUT: 4 16 ※When selecting cycle or phase control mode, the power supply for a load and a temperature
SENSOR
N No alarm output
Input Sensor and Temperature Range [IN-T] controller must be the same.
12VDC ±2V
SOURCE ※1
Sub output 20mA Max 100-240VAC 5VA 50/60Hz 5 17
※In case of selecting cycle [CYCL] or phase [PHAS] control mode for PID control, control cycle [T] is
1 Alarm1 output TC 24VAC 5VA 50/60Hz
Input sensor Display Temperature range (℃) Temperature range (℉) 24-48VDC 3W
6 18 not allowed to set.
2 Alarm1 + Alarm2 output※2
K (CA) KCA -50 to 1200 -58 to 2192 ※For AC/DC power model (TC4 - 2R), this parameter [SSrM] is not displayed and it is available only
TC4M Series 7 19
S DIN W48 H48mm (terminal block type) Thermocouple J (IC) JIC -30 to 500 -22 to 932 SSR OUT: AL1 OUT: standard control by relay or SSR.
12VDC ±2V 250VAC 1A 1a
SP DIN W48 H48mm (11pin plug type)※3 L (IC) LIC -40 to 800 -40 to 1472 1 10 20mA Max 8 20
AL2 OUT: 1)Standard ON/OFF control [STND]
Y DIN W72 H36mm DPtH -100 to 400 -148 to 752 2 11 250VAC 1A 1a
A mode to control the load in the AC
Size DPt100Ω 9 21
M DIN W72 H72mm DPtL -100.0 to 400.0 -148.0 to 752.0 Relay OUT: same way as Relay output type.
RTD 3 12 250VAC 3A 1a B' RTD TC OUT
H DIN W48 H96mm CUsH -50 to 200 -58 to 392 10 22 - (ON: output level 100%, ON OFF ON OFF
Cu50Ω OFF: output level 0%)
W DIN W96 H48mm CUsL -50.0 to 200.0 -58.0 to 392.0 SSR OUT: 4 AL1 OUT: 13 B +
11 23
12VDC ±2V 250VAC 1A 1a -

Digit
L DIN W96 H96mm
Installation 20mA Max 5 AL2 OUT:
250VAC 1A 1a
14
SOURCE
※1
+
12 24
A
SENSOR
2)Cycle control [CYCL]
A mode to control the load by AC
4 9999 (4 Digit) 6 15 100-240VAC 5VA 50/60Hz
TC4S/SP (48 48mm) Series TC4Y (72 36mm) Series Other Series Relay OUT: 24VAC 5VA 50/60Hz repeating output ON / OFF
Setting type 24-48VDC 3W
C Set by touch switch 7 250VAC 3A 1a
16
B' RTD TC according to the rate of output
- ※1: AC power: 100-240VAC 5VA 50/60Hz within setting cycle. OUT
Item B + AC/DC power: 24VAC 5VA 50/60Hz 50Cycle 50Cycle
T Temperature controller 8 17 Having improved ON / OFF noise
24-48VDC 3W
A feature by Zero Cross type. 50% 80%
※1: In case of the AC voltage model, SSR drive output method (standard ON/OFF control, cycle control, SOURCE 9 18 SENSOR
100-240VAC 5VA 50/60Hz
phase control) is available to select. 24VAC 5VA 50/60Hz 3)Phase control [PHAS]
※2: It is unavailable for TC4SP, TC4Y. 24-48VDC 3W
A mode to control the load by
※3: Sockets for TC4SP (PG-11, PS-11(N)) are sold separately. ※Use crimp terminals or teminals of size specified below. a controlling the phase within
AC half cycle. Serial control is AC
※The above specifications are subject to change and some models may be discontinued a b a b c b
without notice. available.
<Round> <Forked> <Crimp terminal> (unit: mm)
Random turn-on SSR must be OUT
※Be sure to follow cautions written in the instruction manual and the technical descriptions Terminal number a b c
※Mount the product on the panel, fasten bracket by pushing with tools as shown above. a Min. 3.0mm Min. 3.0mm used for this mode. 10% 50%
(catalog, homepage). b Max.5.8mm Max.5.8mm 1 to N 6 Max. 1.9 Max. 4.0
(In case of TC4Y, fasten bolts for bracket.)
Set both alarm operation and alarm option by combining.
Parameter Groups RUN mode
● Parameter Group 2
※1: S : Press any key among , , .
Alarm [AL-1/ AL-2] Each alarm operates individually in two alarm output models. Input Correction [IN-B]
⑤ When the current temperature is out of alarm range, alarm Controller itself does not have errors but there may be error by external input temperature sensor. This function
Press any key among
※2: After checking/changing set value at each parameter, and press AM!A clears automatically. If alarm option is alarm latch or alarm latch is for correcting this error.
① ② 2sec. ③ 4sec. key, set value flashes twice and it moves to next parameter Alarm Alarm and standby sequence 1/2, press digital input key( + 3 sec., E.g.) If actual temperature is 80℃ but controller displays 78℃, set input correction value [IN-B] as '002' and
, , , . Run mode automatically. operation option
digital input key[DI-K] of Parameter group 2 set as AlRE), or controller displays 80℃.
4 sec. ※Press key for 3 sec. to return RUN mode at any parameter. 1)Alarm operation ※As the result of input correction, if current temperature value (PV) is over each temperature range of input
SV setting Parameter group 1[PAR1] Parameter group 2[PAR2] turn OFF the power and turn ON to clear alarm.
3 sec. ※ This parameter might not be displayed depending on other sensor, it displays 'HHHH' or 'LLLL'.
PAR2 Mode Name Alarm operation Description
3sec. 3sec. parameter settings.

④ Input type
AM)_ - - No alarm output Input Digital Filter [MAvF]
※1
AL1 AL1 alarm temperature IN-Tㄴㄴ Input type
IN-T KCA JIC LIC DPtH DPtL CU%H CU%L Deviation
OFF H ON OFF H If deviation between PV and SV
ON If current temperature (PV) is fluctuating repeatedly by rapid change of input signal, it refl ects to MV and stable
as high-limit is higher than set control is impossible. Therefore, digital filter function stabilizes current temperature value.
AL2 AL2 alarm temperature UNITㄴㄴ Temperature unit AM! high-limit SV PV PV SV
※2 ※When changing input type, SV, IN-B, H-SV, L-SV, AL1, AL2, LBaT, value of deviation temperature, For example, set input digital filter value as 0.4 sec, and it applies digital filter to input values during 0.4 sec and
alarm 100℃ 110℃ 90℃ 100℃
High deviation: Set as 10℃ High deviation: Set as -10℃ the alarm output will be ON. displays this values. Current temperature may be different by actual input value.
AT Auto tuning IN-Bㄴㄴ Input correction LBaB, AHYS parameters are initialized.

Pㄴㄴ Proportional band MAvFㄴㄴ Input digital filter


Temperature unit
UNIT ?C ?F
※Front temperature unit indicator will flash when
selecting the unit.
ON H OFF ON H OFF
If deviation between PV and SV Hysteresis [HYS]
Deviation ●● If Hysteresis is too narrow, hunting (oscillation,
※When changing temperature unit, SV, IN-B, H-SV, PV SV SV PV as low-limit is higher than set
AM@ low-limit Heating operation
I Integral time L-SV SV low-limit value
L-SV, AL1, AL2, LBaT, LBaB, AHYS parameters 90℃ 100℃ 100℃ 110℃ value of deviation temperature, chattering) could occur due to external noise.
alarm Lower deviation: Set as Lower deviation: Set as ●● In case of ON / OFF control mode, even if PV reaches Control
Input correction are initialized. the alarm output will be ON.
D Derivative time H-SV SV high-limit value
IN-Bㄴㄴ 000 Setting range: -999 to 999 (DPtL / CUsL: -199.9 to 999.9)
10℃ -10℃ stable status, there still occurs hunting. It could be due output ON OFF
Manual reset (Normal to Hysteresis [HYS] SV, load’s response characteristics
REST deviation correction)
O-FTㄴㄴ Control output operation Deviation ON H OFF H ON If deviation between PV and SV
or sensor’s location. In order to reduce hunting to a
Hysteresis
Input digital filter high/low- as high/low-limit is higher than set [HYS]
HYS ON/OFFcontrol hysteresis C-MD Control type Setting range: 0.1 to 120.0 sec. AM# PV SV PV minimum, it is required to take into following factors Temp.
limit 90℃ 100℃ 110℃
value of deviation temperature,
MAvF )1 ※Set input digital filter time for average input value affected control, consideration when designing temp. controlling; SV
alarm High/Lower deviation: Set as 10℃ the alarm output will be ON.
※1: It is not displayed for AC/DC power model (TC4 - 2R). OUTㄴㄴ Control output and display value. proper Hysteresis [HYS], heater’s capacity, thermal
※If no key entered for 30 sec., it returns to RUN mode SV low-limit value Deviation characteristics, sensor’s response and location.
SSrMㄴㄴ SSR drive output method※1 Setting range: W
 ithin the rated temperature If deviation between PV and SV
※In case of [IN-T] high/low- OFF H ON H OFF

※
automatically and the set value of parameter is not be saved.
This parameter might not be displayed depending on T Control cycle
L-SV -050 range by input sensor [L-SV ≤ ( H-SV-1digit)]
When changing SV low-limit value,
input sensor type, AM$ limit
as high/low-limit is higher than set
value of deviation temperature,
Manual Reset [REST] ●Manual reset [REST] by control result
low/high-limit setting PV SV PV Set below 50.0 as reset value
if SV < L-SV, SV is initialized as L-SV. reserve When selecting P/PD control mode, certain temperature difference
other parameter settings. temperature (SV) is
90℃ 100℃ 110℃ the alarm output will be OFF.
AL-1ㄴㄴ AL1 alarm operation mode SV high-limit value Setting range: W
 ithin the rated temperature
alarm High/Lower deviation: Set as 10℃ exists even after PV reaches stable status because heater's rising
①P  ress any key once in RUN mode, it advances to set value also set as max./min. and falling time is inconsistent due to thermal characteristics of Offset
setting group. AL-2ㄴㄴ AL2 alarm operation mode H-SV 1200 range by input sensor [H-SV ≥ ( L-SV+1digit)] temperature range of OFF H ON OFF H ON controlled objects, such as heat capacity, heater capacity. This
SV
When changing SV high-limit value, Absolute Offset
②P  ress key over 2sec. in RUN mode, it advances to input sensor. If PV is higher than the absolute temperature difference is called offset and manual reset [REST]
AHYSㄴㄴ Alarm output hysteresis Control output operation
if SV > H-SV, SV is initialized as H-SV. AM% value high PV SV SV PV
value, the output will be ON. function is to set/correct offset.
parameter group 1. limit alarm
90℃ 100℃ 100℃ 110℃ Set over 50.0 as reset value
When PV and SV are equal, reset value is 50.0%. After control
③P  ress key over 4sec. in RUN mode, it advances to LBaTㄴㄴ LBA monitoring time O-FT HEAT COOL ※When changing control output operation, ErMU is Absolute-value Alarm:
Set as 90℃
Absolute-value Alarm:
Set as 110℃
initialized. is stable, PV is lower than SV, reset value is over 50.0% or PV is
Parameter group 2.
④F
LBaBㄴㄴ LBA detection range ON H OFF ON H OFF higher than SV, reset value is below 50.0%.
 irst parameter will be displayed on viewer when it
Absolute
advances to the setting group. DI-Kㄴㄴ Digital input key Control type
AM^ value low PV SV SV PV If PV is lower than the absolute
value, the output will be ON.
Digital Input Key ( + 3sec.) [ DI-K]
⑤P ONOF ※When changing control type, ErMU is initialized
 ress key over 3sec. in the setting group, it returns Control output MV in case 90℃ 100℃ 100℃ 110℃
ErMVㄴㄴ C-MD PID limit alarm Parameter Operation
of input break error (control output MV is below 100%) and DI-K turns Absolute-value Alarm: Absolute-value Alarm:
to RUN mode. Set as 90℃ Set as 110℃
OFF automatically. OFF OFF It does not use digital input key function.
※Exception: Press key once in SV setting group it LOCㄴㄴ Parameter lock Sensor It will be ON when it detects
SBa - Pauses control output. Auxiliary output (except loop break alarm, sensor break alarm)
returns to RUN mode. Control output break alarm sensor disconnection.
except Control output operates as setting. Hold the digital input keys for 3 sec. to restart.
※Press key again within a sec after return to RUN mode by press key over 3sec., it OUT RLY SSR ※Operates only selected output between Relay or SSR. Loop break
-
It will be ON when it detects loop Digital input key
LBa
alarm break. RUN/STOP
t t t t (t: over 3 sec.)
advances to the first parameter of previous setting group. STOP
※Parameter setup Parameter group 2 → ※ H: Alarm output hysteresis[AHYS]
Parameter group 1 → SV setting
2)Alarm opetion RUN STOP RUN STOP RUN
• Set parameter as the above considering parameter relation of each setting group. SSR drive ※It is displayed when selecting control
output method Option Name Description
• Check parameter set value after change parameter of Parameter group 2. output [OUT] as SSR. For AC/ Clears alarm output by force.
SSrM STND CYCL PHAS Standard If it is an alarm condition, alarm output is ON. If it is a clear alarm condition, alarm output (only when alarm option is alarm latch, or alarm latch and standby sequence 1/2 .)
※Indicator model (TC4 -N N)displays shaded parameter ( ) of Parameter group 2. DC power type (TC4 - 2R), this ㅁㅆAM .A Clear alarm AlRE
※AL-1, AL-2 parameters of Parameter group 2 is decided whether to display according by alarm output type. parameter [SSrM] is not displayed. alarm is OFF. This function is applied when present value is out of alarm operation range but alarm
※If alarm operation mode[AL-1, AL-2] of Parameter group 2 is set to AM)_/ SBa / LBa , AHYS If it is an alarm condition, alarm output is ON and maintains ON status. output is ON. Alarm operates normally right after clearing alarm.
Setting range:0.5 to 120.0 sec. AM ㅁ.ㅜㅜㅠㅠㅠㄱㅠㅠㅠㅁB Alarm latch
parameter is not displayed. Control cycle (Alarm output HOLD) Starts/Stops auto-tuning. This function is same as auto-tuning[AT] of parameter group 1.
T 02)0 ※If control output [OUT] is set as RLY, factory default is 20.0 sec, or First alarm condition is ignored and from second alarm condition, standard alarm (You can start auto-tuning [AT] of parameter group 1 and stop it by digital input key.)
● Flow Chart For SV Setting Group set as SSR, factory default is 2.0 sec. AM .C
Standby
operates. When power is supplied and it is an alarm condition, this first alarm condition Auto-tuning AT ※This parameter AT appears only when control method [C-MD] Parameter group 2
※In case of changing set temperature from 210℃ to 250℃ ※This T will not be displayed when SSR drive output method [SSrM] sequence 1 is set as PID. When control method [C-MD] Parameter group 2 is set as ONOF, this
is ignored and from the second alarm condition, standard alarm operates.
is set as CYCL, PHAS. Alarm latch If it is an alarm condition, it operates both alarm latch and standby sequence. When parameter is changed as OFF.
①RUN mode (display current temperature)
AL1 alarm operation ※Press key to AM .D and standby power is supplied and it is an alarm condition, this first alarm condition is ignored and
AL-1 AM!A LBaA AM!Aㄴ AM!B convert alarm sequence 1 from the second alarm condition, alarm latch operates. Control Output MV When Input Sensor Line Is Broken [ErMV]
operation mode First alarm condition is ignored and from second alarm condition, standard alarm The function to set control output MV in case of open error. Users are able to set by ON/OFF setting or MV
※Alarm operation mode Standby
※Alarm option into alarm option. AM .E operates. When re-applied standby sequence and if it is alarm condition, alarm output setting. It executes control output by set MV regardless of ON/OFF or PID control output.
Press any key among , , , . ③Finish the setup. sequence 2
AL2 alarm operation does not turn ON. After clearing alarm condition, standard alarm operates.
※Same with the above [AL-1].
②Set value change mode AL-2 AM@A
※When changing alarm operation AL1, AL2, alarm temperature of Alarm latch
Basic operation is same as alarm latch and standby sequence1. It operates not only by
power ON/OFF, but also alarm setting value, or alarm option changing. When re-applied
Parameter Lock [LOC] Display Description
Change set value AL1, AL2 is initialized. AM .F and standby A function to prevent changing SV and parameters of OFF Unlock
standby sequence and if it is alarm condition, alarm output does not turn ON. After
by , , keys. Alarm output hysteresis sequence 2 each setting group. Parameter setting values are still LOC1 Lock parameter group 2
Setting range: 1 to 100℃/℉ (DPtL/ CYsL: 0.1 to 50.0℃) clearing alarm condition, alarm latch operates. LOC2 Lock parameter group 1, 2
possible to check when parameter lock is set.
AHYS 001 ※If alarm operation mode [AL-1, AL-2] is set to AM)_, SBa , Condition of re-applied standby sequence for standby sequence 1, alarm latch and standby sequence 1: Power ON LOC3 Lock parameter group 1, 2, SV setting
※ OFF, LOC1 are available only for indicator (TC4 -N N).
④Check SV LBA , AHYS parameter is not displayed. Condition of re-applied standby sequence for standby sequence 2, alarm latch and standby sequence 2: Power ON,
● Parameter Reset LBA monitoring time Setting range: 0 to 9999sec. (Automatically setting with Auto-tunning)
changing set temperature, alarm temperature [AL1, AL2] or alarm operation [AL-1, AL-2], switching STOP mode
to RUN mode.
Error
Reset all parameters as factory default. Hold the front + + keys for 5 sec., to enter parameter reset [INIT] ※LBaT parameter is displayed when alarm operation mode [AL-1, Display Description Troubleshooting
LBaT 0 AL-2] is set as LBA . 3)Sensor break alarm Flashes if input sensor is disconnected or sensor
parameter. Select 'YES' and all parameters are reset as factory default. Select ‘NO’ and previous settings are OPEN Check input sensor state.
The function that alarm output will be ON when sensor is not connected or when sensor's disconnection is is not connected.
maintained. If setting parameter lock [LOC] or processing auto-tuning, parameter reset is unavailable.
Setting range: 0 to 999℃/℉ (DPtL/ CUs: 0.0 to 999.9℃/℉) detected during temperature controlling. You can check whether the sensor is connected with buzzer or other Flashes if measured sensor input is higher than
LBA detection band HHHH
● Parameter Group 1 ※1: S : Press any key among , , . (Automatically setting with Auto-tunning) units using alarm output contact. It is selectable between standard alarm [SBaA] or alarm latch [SBaB]. temperature range. When input is within the rated temperature
※2: After checking/changing set value at each parameter, and press LBaB 002 ※When alarm operation mode [AL-1, AL-2] is set as loop break Flashes if measured sensor input is lower than range, this display disappears.
3 sec. 4)Loop break alarm (LBA) LLLL
Run mode key, set value flashes twice and it moves to next parameter alarm (LBA) [LBA ], and LBaT parameter does not set as 0, temperature range.
LBaB parameter is displayed. It checks control loop and outputs alarm by temperature change of the subject. For heating control (cooling
automatically.
PAR1
2 sec.
※3: It is displayed when control type parameter [C-MD] of parameter Digital input key
control), when control output MV is 100% (0% for cooling control) and PV is not increased over than LBA
detection band [LBaB] during LBA monitoring time [LBaT], or when control output MV is 0% (100% for cooling
Cautions during Use
group 2 is set PID. DI-K OFF STOP AlRE AT control) and PV is not decreased below than LBA detection band 1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
※Press key for 3 sec. to return RUN mode at any parameter. 2. Check the polarity of the terminals before wiring the temperature sensor.
※AlRE is not displayed for not alarm output model. [LBaB] during LBA monitoring time [LBaT], alarm output turns ON.
AL1 alarm temperature ※1 ※ This parameter might not be displayed depending on other For RTD temperature sensor, wire it as 3-wire type, using cables in same thickness and length.
※AT is not displayed when control type parameter [C-MD] is set ONOF.
AL1 1250 parameter settings. Control output MV in case Setting range: 0.0 to 100.0%
For thermocouple (CT) temperature sensor, use the designated compensation wire for extending wire.
Setting range: Deviation alarm (-[F.S] to [F.S], of input break error 3. Keep away from high voltage lines or power lines to prevent inductive noise.
※2
※0.0/100.0% is displayed when control type parameter [C-MD] is In case installing power line and input signal line closely, use line filter or varistor at power line and shielded
Absolute value alarm (temperature range) ErMV 00)0 set ONOF. wire at input signal line.
AL2 alarm temperature ※In case alarm operation mode [AL-1, AL-2], AM)_/ SBa ※When changing PID control to ON/OFF control, if MV is below Do not use near the equipment which generates strong magnetic force or high frequency noise.
AL2 1250 / LBa of Parameter group 2 is set to [AL-1, AL-2], no 100.0%, it is initialized as 0.0%.
Parameter lock ※For indicator model 4. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
parameters is displayed.
※3 (TC4 -N N), only OFF, 5. Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature controller.
LOC OFF LOC1 LOC2 LOC3
LOC1 are available. 6. When changing the input sensor, turn off the power first before changing.
Auto-tuning ※It starts to operate auto-tuning when it is ON and
After changing the input sensor, modify the value of the corresponding parameter.
set as OFF automatically after finish the operation. 7. 24VAC, 24-48VDC power supply should be insulated and limited voltage/current or Class 2, SELV power
AT OFF ON
※Deviation indicators (▲, , ▼) flash (cycle:1
sec.) during auto tuning function. Factory Default supply device.
8. Make a required space around the unit for radiation of heat.
Time
Proportional band ● SV setting ● Parameter Group 2 For accurate temperature measurement, warm up the unit over 20 min after turning on the power.
01)0 Setting range: 0.1 to 999.9℃/℉ 9. Make sure that power supply voltage reaches to the rated voltage within 2 sec after supplying power.
P Parameter Factory default Parameter Factory default Parameter Factory default 10. Do not wire to terminals which are not used.
- 0 IN-T ㅏKCA T 02)0 Start control When control output MV is 100%, PV is increased over than LBA detection band [LBaB] during
11. This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specifications') ②Altitude max. 2,000m
Integral time UNIT ?C to LBA monitoring time [LBaT].
Setting range: 0 to 9999 sec. ③Pollution degree 2 ④Installation category II
I 0000 ● Parameter Group 1 AL-1 AM!A to The status of changing control output MV (LBA monitoring time is reset.)
※Integral operation will be OFF when set value is "0". IN-B 0000
Parameter Factory default
MAvF 00)1 AL-2 AM@A to
When control output MV is 0% and PV is not decreased below than LBA detection band [LBaB] Major Products
AL1 during LBA monitoring time [LBaT], loop break alarm (LBA) turns ON after LBA monitoring time. Photoelectric Sensors Temperature Controllers
Derivation time 1250 Fiber Optic Sensors Temperature/Humidity Transducers
Setting range: 0 to 9999 sec. L-SV -050 AHYS 0001 to Control output MV is 0% and loop break alarm (LBA) turns and maintains ON.
D 0000 AL2 Door Sensors SSRs/Power Controllers
※Derivative operation will be OFF when set value is "0". H-SV 1200 LBaT 0000 Door Side Sensors Counters
to The status of changing control output MV (LBA monitoring time is reset.)
AT OFF Area Sensors Timers
O-FT HEAT LBaB 002 When control output MV is 100% and PV is not increased over than LBA detection band [LBaB] Proximity Sensors Panel Meters
Manual reset P 01)0 to
during LBA monitoring time [LBaT], loop break alarm (LBA) turns ON after LBA monitoring time.
Pressure Sensors Tachometer/Pulse (Rate) Meters
Setting range: 0.0 to 100.0% C-MD PID DI-K STOP Rotary Encoders Display Units http://www.autonics.com
REST 05)0 I When control output MV is 100% and PV is increased over than LBA detection band [LBaB] Connector/Sockets Sensor Controllers
※It is displayed in P/PD control. 0000 OUT RLY ErMV 00)0 to Switching Mode Power Supplies HEADQUARTERS:
D during LBA monitoring time [LBaT], loop break alarm (LBA) turns OFF after LBA monitoring time. Control Switches/Lamps/Buzzers 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
SSrM STND LOC OFF to The status of changing control output MV (LBA monitoring time is reset.) I/O Terminal Blocks & Cables South Korea, 48002
ON/OFFcontrol
Setting range: 1 to 100℃/℉ (For DPtL/CUsL: 0.1 to 50.0℃/℉)
REST 05)0 Stepper Motors/Drivers/Motion Controllers TEL: 82-51-519-3232
hysteresis ※AC/DC power type has no SSR drive output method [SSrM] and  hen executing auto-tuning, LBA detection band[LBaB] and LBA monitoring time are automatically set based
W Graphic/Logic Panels
E-mail: sales@autonics.com
※It is displayed when control type parameter [C-MD] of Parameter HYS 002 supports only ON/OFF output when selecting SSR in control output on auto tuning value. When alarm operation mode [AL-1, AL-2] is set as loop break alarm (LBA)[LBa ], LBA Field Network Devices
HYS 002 Laser Marking System (Fiber, Co₂, Nd: YAG)
group 2 is set ONOF. [OUT]. detection band [LBaB] and LBA monitoring time [LBaT] parameter is displayed. Laser Welding/Cutting System DRW170775AA