FUEL INJECTION PUMP CALIBRATION REPORT

DATE : 30 DESEMBER 2021

S/N : 2416966FR

REG No : SD-484-21

FIP : HD785-5 RH

TEST unit set value min max actual


SPECIFICATION
Pre stroke (as of BDC) mm - - - -
Rack Travel mm 12,80 12,60 13,20 12,80
Rack Sensor volt 2,550 2,540 2,570 2,550
Setting point
Speed rpm 1050 - - 1050
Rack position mm 12,80 12,40 13,20 12,80
Delivery cm3/1000s 400 - - 400
Spread cm3/1000s - - - -
Speed rpm 300 - - 300
Rack position mm - - - -
Delivery cm3/1000s 40 - - 40
Spread cm3/1000s - - - -
Aneroid pressure hpa - - - -
Full Load Delivery
Speed rpm 1050 - - 1050
Delivery cyl. 1/2/3 cm3/1000s 400 398 405 400/400/400
Delivery cyl. 4/5/6 cm3/1000s 400 398 405 400/400/400
Spread cm3/1000s - - - -
Aneroid pressure hpa - - - -
Full Load Speed Assembly Governoor
Delivery cm3/1000s - - - -
Speed rpm - - - -
Delivery cm3/1000s - - - -
Speed rpm - - - -
Delivery cm3/1000s - - - -
Speed rpm - - - -
Idle Delivery
Speed rpm 300 - - 300
Delivery 1/2/3 cm3/1000s 40 35 45 40/40/40
Delivery 4/5/6 cm3/1000s 40 35 45 40/40/40
Spread cm3/1000s - - - -