You are on page 1of 10

Job Number Sheet

Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

S12
Beam - Column Connection - Ver W2.5.03 - 21 Oct 2010

Title : Default Connection


Code of Practice : AISC - 1999 LRFD
Created : 7/19/2013 4:39:44 AM

Notes and Assumptions


1 All bolt holes are assumed to be normal clearance holes.
2 All bolts are assumed to have threads in their shear planes.
3 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.
4 It is assumed that compressive forces in flanges and stiffeners
are conveyed through welds and not through bearing.
5 Axial force in the column is not considered in the design.

Summary

Summary of Forces and Capacities for Design to AISC - 1999 LRFD

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 1 65.3 203 kN 32.1 O.K.

2 Weld Web 1 13.7 511.1 kN 2.7 O.K.

3 Column Web Tension Yielding 1 65.3 426.2 kN 15.3 O.K.

4 Column Web Compression Crippling 1 64.3 168.5 kN 38.2 O.K.

5 Column Web Compression Buckling 1 64.3 192.4 kN 33.4 O.K.

6 Column Web Shear 1 65.3 194.4 kN 33.6 O.K.

7 Bolts & Flange Tension & Bending 1 33.1 43.2 kN 76.7 O.K.

8 Column Flange Bearing 1 1.7 145.8 kN 1.2 O.K.

9 Bolts & End Plate Tension & Bending 1 33.1 40.2 kN 82.4 O.K.

10 End Plate Bearing 1 1.7 194.4 kN 0.9 O.K.

11 Bolts Shear 1 1.7 24.1 kN 7.1 O.K.

12 Bolts Shear & Tension 1 16.6 45.2 kN 36.7 O.K.

13 Bolts Slip N/A N/A N/A kN N/A N/A

Input
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

General Settings
Bolt Tension Analysis Plastic
Bolt Type Bearing
Bolt Grade 4.6
Member Ultimate Strength 450
Member Yield Strength 240
Weld Ultimate Strength 480

Connection Type Flush End Plate


Column 250x125x29 I1
Beam 250x125x29 I1
Column Extent Above(mm) 30
Beam Angle -8
Haunch Depth (mm) 90
Haunch Length (mm) 200
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Ultimate Limit State Loads in Beam SLS Factor


(Divide to
Load Case Shear Axial Moment
get Loads)
(kN) (kN) (kNm)
1 13.7 1 21.6 1

Width (mm) 165


Extent Above Beam Flange (mm) N/A
End Plate Extent Below Haunch (mm) N/A
Thickness (mm) 12
Stiffeners N/A
Width (mm) None
Top Stiffener Thickness (mm) None
Column Stiffeners Bottom Stiffener Thickness (mm) None
Shear Stiffener Thickness (mm) None
Shear Stiffener Orientation None
Layout None
Web Plates
Thickness (mm) 10
Top Backing Plate Thickness (mm) None
Bottom Backing Plate Thickness (mm) None
Bolts Diameter (mm) 16
Above Top Flange N/A
Below Top Flange 3
Rows of Bolts Above Haunch 1
Below Haunch N/A
Row Spacing (mm) 75
Web (mm) 40
Bolt Offsets Flange (mm) 40
Above Haunch (mm) 50
Beam & Haunch Flanges 6
Beam Web (mm) 6
Welds Top Stiffener (mm) N/A
Bottom Stiffener (mm) N/A
Shear Stiffener (mm) N/A

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 1
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Fw = 65.251 kN

Table J2.5

 . F w. Aw
Rw =
1000
0.75 ×288 ×939.986
=
1000
= 203.037 kN

Beam Flange Weld is safe

Check 2 : Capacity of the Beam Web Welds


The worst load is encountered for Load Case : 1
Fw = 13.706 kN

Table J2.5

 . Fw. Aw
Rw =
1000
0.75 ×288 ×2 366.017
=
1000
= 511.060 kN

Beam Web Weld is safe

Check 3 : Capacity of the Column web in tension


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =65.251 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
6 ×295.975 ×240
=
1000
= 426.204 kN

No tensile forces in the beam bottom flange

Column web is safe in tension

Check 4 : Crippling Capacity of the Column web in Compression


No compressive forces in the beam top flange
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =64.335 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
6 ×117 ×240
=
1000
= 168.480 kN

Column web is safe in compression for crippling

Check 5 : Buckling Capacity of the Column web in Compression


No compressive forces in the top beam flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =64.335 kN

K1-4
3 . N. tw 1.5 . f y. tf
 . 354.5 . tw2 . 1 +
d tf tw
Rn =
1000
3 ×9.088 6 1.5 240 ×9
0.75 ×354.5 ×6 2 × 1 + × ×
250 9 6
=
1000
= 192.387 kN

Column web is safe in compression for buckling

Check 6 : Shear Capacity of the Column Web


The worst load is encountered for Load Case : 1
when Pv =65.251 kN

K1-7
0.9 . 0.6 . f y. tw. dc
Rv =
1000
0.9 ×0.6 ×240 ×6 ×250
=
1000
= 194.400 kN

Column web shear is safe


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Check 7 : Bolt tension and Column Flange Bending


The worst load is encountered for Load Case : 1

Fmax = 33.125 kN
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the flange

4 . Mpl + 2 . Mbp.
R1 = 1000
m
4 ×0.32805 + 2 ×0
= ×1000
30.4
= 43.164 kN

Mode 2 : Bolt Failure with yielding of the flange

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×0.32805 ×1000 + 19.5 ×2 ×47.1
=
30.4 + 19.5
= 49.960 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×47.1
= 94.200 kN

Therefore R = R1 = 43.164

Bolt tension and Column Flange bending is safe

Check 8 : Bearing on the Column Flange


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 1.713 kN

The Bearing Capacity of the flange at any Bolt is :


J3.10
 . 1.5 . Fu. Lc. t
Rn =
1000
0.75 ×1.5 ×450 ×40 ×9
=
1000
= 182.250 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×16 ×9
=
1000
= 145.800 kN

Column flange bearing is safe

Check 9 : Bolt tension and End Plate Bending


The worst load is encountered for Load Case : 1

Fmax = 33.125 kN
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the End Plate

4 . Mpl .
R1 = 1000
m
4 ×0.5832
= ×1000
55.2
= 42.261 kN

Mode 2 : Bolt Failure with yielding of the End Plate

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×0.5832 ×1000 + 19.5 ×2 ×47.1
=
55.2 + 19.5
= 40.205 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×47.1
= 94.200 kN

Therefore R = R2 = 40.205

Bolt tension and End Plate bending is safe

Check 10 : Bearing on the End Plate


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 1.713 kN

The Bearing Capacity of the Plate at any Bolt is :


J3.10
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

 . 1.5 . Fu. Lc. t


Rn =
1000
0.75 ×1.5 ×450 ×40 ×12
=
1000
= 243.000 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×16 ×12
=
1000
= 194.400 kN

End plate bearing is safe

Check 11 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =1.713 kN

J3.6
C-J3-4
Fn = 0.4 . Fu
= 0.4 ×400
= 160.000 MPa

The resistance of any bolt is :

n .  . F n. A b
Rshear =
1000
1 ×0.75 ×160.000 ×201.062
=
1000
= 24.127 kN

Bolt shear is safe

Check 12 : Shear and Tension Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =16.562 kN

C-J3.7
J3.7
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The resistance of any bolt is :

 . Ft . A b
Rn =
1000
0.75 ×299.574 ×201.062
=
1000
= 45.175 kN

Bolt shear and tension is safe


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces

Bolt Forces for Load Case : 1

16.56 kN

16.56 kN

16.56 kN

0.23 kN

Shear force per bolt : 1.71 kN