Cat.6 U/UTP PVC cable for local networks Catalogue number(s) : 0 327 55

1. USE 4. PERFORMANCE AT 250 MHZ (STAND. ANSI/TIA 568.2-D))


Cable for high-speed VDI transmission networks
Reference 0 327 55
Maximum attenuation 32,8
802.3 bt PoE++ applications compatible according to installation
standards ISO/IEC 14763-2 (final draft) and EN 50174-2 : 2018 (dB/100 m)
Minimum NEXT (dB) 38,3
2. DESCRIPTION PS NEXT (dB) 36,3
ACRF (dB / 100 m) 18,8
Insulation: PE PS ACRF (dB / 100 m) 16,8
Pair Return Loss (dB) 17,3
Copper
5. TECHNICAL AND MECHANICAL FEATURES
X-shaped
separator

Protection: Catalogue 0 327 55


PVC sleeve number
Type U/UTP
Type of sleeve PVC
Number of pairs 4
Assembly Pairs
3. MARKING AND PACKAGING
Diameter over 0,95± 0,05
Marking of Legrand cables insulation (mm)
- LEGRAND Average nominal 5,8 ± 0,3
- Catalogue number diameter of the
- Number of pairs cable (mm)
- Gauge Weight of cable 36
- Type (kg/km)
- Impedance Min. bending 25
radius when
- Type of sleeve
laying (mm)
- Category
AWG gauge* 24
- Conformity to standards
* According to UL 444 ed.3 table 4
- EUROCLASS
- Velocity of propagation
- Traceability
- Measurement (remaining length in metres).

Complementary marking (on label)


- Designation
- Made in....

Fiche technique : S000099461EN-02 Mise à jour le : 13/02/2020 Créée le : 19/06/2017

SOMMAIRE 1/2
Cat.6 U/UTP PVC cable for local networks Catalogue number(s) : 0 327 55

6. ELECTRICAL FEATURES AT 20°C

Catalogue number 0 327 55


Type U/UTP
Maximum linear resistance 95 *
(ohm/km)
DC dielectric strength 1 KV / 1 min *
Minimum insulation resis- 5000
tance (Mohm.km)
Minimum propagation speed 66 %
Characteristic impedance at 100 ±5Ω
100 MHz
* According to standard IEC 61156-5

7. ORDERING INFORMATION

Catalogue 0 327 55
number
Type U/UTP
Colour Blue RAL 5015
Pack (m) 305
Packaging Box

8. ENVIRONMENTAL FEATURES
Transport and storage temperature: -20 at + 60 °C
Storage temperature before installation: 10°C during 24h (if stock ≤ 5°C )
Usage temperature: – 20 to + 60 °C

Fire rating : IEC 60332-1-2, EN 60332-1-2

EUROCLASS EN 13501-6 = Class Eca

9. STANDARDS AND APPROVALS


Cat 6, 250 MHz
Electrical performances and characteristics :
- ANSI/TIA 568.2-D
- EN 50173-1
- EN 50288-6-1
- ISO/IEC 11801 (ed. 2.2)
- IEC 61156-5
IEEE 802.3bt : PoE++

Fiche technique : S000099461EN-02 Mise à jour le : 13/02/2020 Créée le : 19/06/2017

SOMMAIRE 2/2
e­catalogue international version   

CAT. N° 0 327 55

LAN CABLE - CATEGORY 6 - U/UTP - 4 PAIRS - L. 305 M -


PVC SLEEVE

Pack (number of metres) 305

Volume (dm³) 38,834

Weight (g) 12 439,00

Product characteristics General characteristics

Cat. 6 cables for local networks Legrand cabling system, LCS³ cat. 6 - cables and
▪ Performance 250 MHz cords
▪ 4 pairs or 2 x 4 twisted pairs, 100 Ω
▪ Blue RAL 5015
▪ ANSI/TIA colour code
▪ Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568 standards
▪ Products conforming to the new CPR regulations
▪ Euroclass Dca for LSZH cables (except Cat No 0 328 86: Euroclass
Cca), Euroclass Eca for PVC cables
U/UTP - 4 pairs
▪ PVC
▪ Length 305 m
▪ Supplied in cardboard box
▪ Weight 13 kg

Documentation

Catalogue pages & additional information Installation & technical data


▪ Description page (p.402) ▪ S000099461EN-02
▪ Technical page (p.403)
▪ Technical page (p.404)
▪ Technical page (p.405)
▪ Description page (p.736)
▪ Technical page (p.775)
▪ Technical page (p.776)

Environmental product profile


▪ Environnemental product sheet n°O E0123A-EN

* All prices given are the manufacturer's list prices for professional customers, and are given for information only. They are not to be considered as a mandatory retail price ­ Basis : before­tax price list,  May 2018
The information given in this e­catalogue (characteristics and dimensions) may be amended, and therefore does not represent an undertaking on our part. The e­catalogue is reserved for professionals only. You are also reminded that all products  
must be installed by a qualified professional in accordance with the installation rules.