You are on page 1of 11

SYSTEM SPECIFICATION

PROPOSAL
Drywall & Ceiling System
UIN SUNAN AMPEL SURABAYA

Proposal Number:
027/TE/E/0919 – UIN

Proposal Issued:
4 September 2019; Rev.00

Prepared For :
PT. Petrojaya Boral Plasterboard Teresa Elika
Palma Tower, 21th Floor System Specification Representative
Mr. Dhenies
Jl. RA. Kartini III-S Kav. 6, Sektor II Teresa.Elika@usgboral.com Patroon Arsindo, PT
Pondok Pinang, Kebayoran Lama m +62 853 6868 6896 Jalan Jambore Raya Blok V2 No 7 RT06/RW11
Jakarta Selatan 12310 – Indonesia www.usgboral.com Kelurahan Cibubur, Kecamatan Ciracas
t +62 21 2753 8000 Jakarta Timur
f +62 21 2753 8199 Jakarta 13720
Indonesia
Jakarta, 4 September 2019
To.
Mr. Dhenies
Patroon Arsindo, PT

Project: UIN Sunan Ampel Surabaya

Following to your enquiry, we propose drywall & ceiling system for UIN Sunan Ampel Surabaya
project with the terms and conditions as follows:

1. The systems only applied to UIN Sunan Ampel Surabaya project.


2. The material of Sealant, and Insulation are non-USG Boral Products.
3. The results of the installation remain the responsibility of the appointed applicator.
4. For the price if any:
a. Only applied to UIN Sunan Ampel Surabaya project.
b. Exclude any tax.
c. Exclude preliminary cost.
d. Exclude accessories such as Corner Bead, External Angle, and Shadow Line.
e. For reference only, the final price will be provided by applicator / sub-contractors.

Should you have any question or other enquiries, please don’t hesitate to let us know.
Thank you for your attention.

Sincerely yours,

Teresa Elika
System Specification Representative

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 2


Date: 4 September 2019 ; Rev.00
General Notes
Structural Consideration Acoustic Consideration
• All drywall systems both interior and exterior are • The acoustic ratings in this document are calculated by
designed as a Non-Load Bearing. INSUL software or laboratory test results unless
• All maximum heights are based on the deflection otherwise noted. INSUL calculations are based on
criteria of L/240 under a static UDL (Uniformly simple theoretical models that make reasonable
Distributed Load) of 0.25kPa unless otherwise noted. estimates of acoustic performance. Comparisons with
• For partitions height at 3.6m or above, JayaBMS test data show that it is generally within +/- 3 STC
Deflection Head Track shall be used. points for simple constructions, however can be as
• Nogging is recommended to gives a structural stability high as +/- 5 STC points for hybrid systems or triple
for partitions height 3.6m or above. panel constructions. Like any calculation tool, INSUL
• Boarding direction: (1) Vertically, will gives you should not be regarded as a substitute for test data or
structural strength from machine direction of boards, an opinion from a suitably quDheniesfied Acoustic
use it when partitions height could be covered-up by its Engineer. For this reason, the supplied INSUL
length. (2) Horizontally, gives a structural strength by calculations should be used as a guide only.
more frames hold the board and uses it when critical • The STC value in this proposal is only vDheniesd when
lighting treatment is required. the system is installed from floor to slab.
• Performance values are for imperforate, jointed • Perimeters treatment shall be supported by acoustic
systems using only USG Boral components and installed sealant as specified, otherwise the acoustic
to the USG Boral Plasterboard Indonesia's specification performance will be reduced.
given. Any alterations may well impair the quoted • To maintain the acoustic performance, sealant
performance criteria. treatment on top and bottom tracks should be applied
in consideration of uneven slab/floor surfaces.
Fire Rating Consideration • Addition of bracing for twin frame system will reduce
• Fire rating levels are based on lab test or the acoustic performance.
expert/internal opinions. • STC values can be affected by other building
• Frames thickness shall use min 0.5mm BMT. component (Window frame, Door frame, etc).
• Perimeters treatment shall be supported by fireproof • For installation detail requirements which not included
sealant as specified. in this document, please contact System Specification
• Deflection Head Track shall be used to prevent cracking Representative
Tiling on this proposal.
on to Plasterboard System
caused by structural deflection. • Tiles or marbles weight up to 32 kg/m 2 (include
• For fire rating purposes the drywall system must be adhesive/mortar/water proofing treatments) may be
installed from floor to slab. directly bonded on USG Boral Wetarea Optimum
13mm plasterboard surface
Steel Specification
• Tiles or marbles weight up to 45 kg/m 2 (include
• Non-load bearing rolled form metal frames made by
adhesive/mortar/water proofing treatments) may be
metal grade G300 with minimum Yield strength 300
directly bonded to USG Boral DUROCK® 12.7mm with
MPa and Coated by protective layer of AZ50 or Z15 for
DUROCK® Baseflex as an adhesive.
interior.
• Tiles or marbles weight up to 73 kg/m2 (include
• Non-load bearing rolled form metal frames made by
adhesive/mortar/water proofing treatments) on to
metal grade G550 with minimum Yield strength 550
USG Boral Fiberock Aqua Tough 12.7mm.
MPa and Coated by protective layer of Z275 for
• Frames thickness shall use min 0.5mm BMT for interior
exterior.
and min 0.9mm BMT for exterior with spacing 400/406
• Thickness as specified and recommended by USG
mm.
Boral.
• For the tiles or natural stone above 73 Kg/m2,
independent framing system shall be applied.

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 3


Date: 4 September 2019 ; Rev.00
General Notes

Exterior System Others


• Framing size and spacing for exterior wall should be • Drawings and details provided are NOT to scale and
calculated with consideration of wind force pressure, shall be read in conjunction with architecture and
building location, main structure type, window size, structural drawings. All dimensions are subject to
opening and placement. actual site condition and shall be verified by the
• All maximum heights are defined based on the contractor.
deflection criteria of L/360. • Contractor to ensure the workability of proposal to
• Frame thickness should be at min 0.9mm (20-ga) or suit to the site condition.
thicker. • The information and drawing in this System Proposal
• All steel studs must be fastened to steel C tracks in each is the Property and Copyright of USG Boral and must
side with TEK screws. not be re-issue, copied or reproduced without written
• Maximum Steel Stud spacing is 406 mm. consent
• Steel Tracks shall be fastening to structure with anchor • Please contact the System Specification
every max 406 mm. Representative on this proposal for further or more
• Board’s edges, exterior corners and window superior detail information.
edges must be protected with PVC bead components
and covered with DUROCK® Basecoat or DUROCK®
Baseflex®.
• To achieve a smooth and more even finish, paint
primer should be applied after DUROCK® Basecoat or
DUROCK® Baseflex® application.

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 4


Date: 4 September 2019 ; Rev.00
Drywall Partition System

SS-9 Partition Standard


Description
(Revit Model Available)
Area Partition (H : 4000)

Drawing

Board 1 layer of 12mm USG Boral Jayaboard Sheetrock each side


JayaBMS Stud & Track (0.5mm BMT)
Frame
76mm Track & 76mm Stud & 76mm DHT
Stud spacing (mm) 600
Wall Thickness (mm) 100
Max. Height (mm) 4000
Fire Rating 30
STC 34 (Without Insulation), 40 (With Insulation)
System Weight ± 15Kg/m²
Estimated Price Material Only (IDR/Sqm) 123.000,- (Exclude Insulation & Sealant)

SS-9 Partition Standard


Description
(Revit Model Available)
Partition (H : 5000)
Area
(Using Structural Divider) *See Attachment

Drawing

Board 1 layer of 12mm USG Boral Jayaboard Sheetrock each side


JayaBMS Stud & Track (0.4mm BMT)
Frame
76mm Track & 76mm Stud
Stud spacing (mm) 600
Wall Thickness (mm) 100
Max. Height (mm) 3800
Fire Rating N/A
STC 34 (Without Insulation), 40 (With Insulation)
System Weight ± 15Kg/m²
Estimated Price Material Only (IDR/Sqm) 209.500,- (Exclude Insulation & Sealant & Structural Divider)

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 5


Date: 4 September 2019 ; Rev.00
Concealed Ceiling System

Description CS-18FC – Furring Channel System

Area Standard Area >100m2

Drawing

System Standard Ceiling Furring System


Board 1 layer of 12mm USG Boral Sheetrock
Frame JayaBMS Furring Channel system
Suspension Spacing (mm) 1200
Top Cross Rail Spacing (mm) 1200
Furring Spacing (mm) 600
Recommended Coverage Area > 100m²
System Weight ± 8 Kg/m²
Estimated Price Material Only (IDR/Sqm) 94.000,-

Description CS-20 – Easy Frame System

Area Standard Area <100m2

Drawing

System Standard Ceiling Easy Frame System


Board 1 layer of 9mm USG Boral Sheetrock
Frame JayaBMS Ceiling Easy Frame system
Suspension Spacing (mm) 1200
Top Cross Rail Spacing (mm) 1000
Furring Spacing (mm) 600
Recommended Coverage Area < 100m2
System Weight ± 6.5 Kg/m²
Estimated Price Material Only (IDR/Sqm) 64.000,-

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 6


Date: 4 September 2019 ; Rev.00
Description CS-20 – Easy Frame System (Wetarea)

Area Toilet

Drawing

System Standard Ceiling Easy Frame System


Board 1 layer of 9mm USG Boral Wetarea Optimum
Frame JayaBMS Ceiling Easy Frame system
Suspension Spacing (mm) 1200
Top Cross Rail Spacing (mm) 1000
Furring Spacing (mm) 600
Recommended Coverage Area < 100m2
System Weight ± 6.5 Kg/m²
Estimated Price Material Only (IDR/Sqm) 70.000,-

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 7


Date: 4 September 2019 ; Rev.00
Exposed Grid Ceiling System

Description ECS-2 EXPOSED GRID CEILING SYSTEM PANEL GYPSUM TILE BYHUA (9x600x600)

Panel Texture

Area General
System Ceiling T24 Grid System
USG Boral Byhua SE
Panel
9x600x600 (mm)
Color White
JayaBMS T-24 GRID (Cross tee) PN-401 & PN-402
Frame JayaBMS T-24 GRID (Main Runner) PN-400
JayaBMS Wall Angle L PN-408
Suspension clip (mm) @1200 (BMS : PN-409, PN-220, PN-410s)
Main Runner (mm) 3600
Cross tee (mm) 1200 (long), 600 (short)
Panel Weight ± 6.2 Kg/m²
Metal Frame Detail

Grid & Panel Detail JayaBMS T24 Frame Details

Estimated Price Material


64.500,-
Only (IDR/Sqm)

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 8


Date: 4 September 2019 ; Rev.00
Acceptance of Proposal

Specifications Approval

Drywall Partition System


1. SS-9 – Single Stud System with 1 layer of USG Boral Sheetrock 12mm. H:4000 □
2. SS-9 – Single Stud System with 1 layer of USG Boral Sheetrock 12mm. H:5000 □
Concealed Ceiling System
1. CS-18FC – Furring Channel System with 1 layer of USG Boral Sheetrock 12mm. □
2. CS-20 – Easy Frame System with 1 layer of USG Boral Sheetrock 9mm. □
3. CS-20WA – Easy Frame System with 1 layer of USG Boral WAO 9mm. □
Exposed Grid Ceiling System
1. ECS-1 – Exposed Grid Ceiling System with USG Boral Gyptile Byhua 9mm (600x600) □

Notes:

Jakarta, 4 September 2019


Client,

_____________________
Mr. Dhenies

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 9


Date: 4 September 2019 ; Rev.00
Attachment

027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 10


Date: 4 September 2019 ; Rev.00
027/TE/E/0919 – UIN – UIN Sunan Ampel Surabaya 11
Date: 4 September 2019 ; Rev.00