STANDARD DATA SHEET

4/20/2018
General Information ( Customer Requirements)
End User PTAR LAs Esclusas Manufacturer TNE Korea Co., Ltd.
Project/ Application WWTP Contractor Estruagua - Floculacion
Site Location Ecuador Place of Installation Indoor ● Outdoor ○ E/F ○
Site Amb. Condition 14.7 PSIA 26.0 deg C 36 % RH Application FLOCULACION
Working Gas R AIR  NITROGEN Number of Units Total 3 Working 3 Standby 0

Standard Specification Performance (Q1:Suction Air Flow, P2:Discharge Pressure, T2, Discharge Temp, Wm : Motor Output Power)
Inlet Conditions 14.70 PSIA 26.0 deg C 36 % RH Model CT-R41M-055
Operating Perf. Q1 = 3230 m3/h P2 = 8.65 PSIG T2 = 74.7 deg C
Wm = 54.6 kW (SBHP = 69.5 HP)
Mode of Operation Local/Remote Number of Impellers 1
Bearing Air Bearing Weight 570 kg
Coupling Direct Noise Under 80 dB (A) Size (W/L/H) 830 mm / 1480 mm / 1420 mm
Type of VFD Integrated ● Separated ○ Service Area (W/L/H) mm / mm / mm

Electrical - Motor and Control system (Total Power : Total Rated Output Power)
Type Permanent Magnet Synchronous Motor Max Output Power 55.0 kW Package Total 55.0 kW
Starting Soft Starting by VFD Rated Output Power 55.0 kW Package Total 55.0 kW
Cooling Air Number of Motors 1
Number of Phase 3 Number of Poles 2 Insulation H Class
Totally Enclosed YES Input Voltage 380 V 440 V 480 V
Service Factor 1.15 FLA (Package Total) 103 A 89 A 81 A
Electric Efficiency > 95% at 50,75 and 100% rated load Design RPM 26533

Installation
RLouver Flange Discharge Type Flange 8 INCH
Suction Inlet Type
if Flange - INCH Outlet Accessories RCheck RFlexible RStop
Foot Type Anchor RLevel Adjuster Electricity 380~480V - 50/60Hz - 3Ph
Size of Cable Cable Inlet RBottom Top
Communication RHard Wiring Modbus ( Serial LAN ) Others ( Ethernet Profibus Profitnet )
Room Ventilation Fan Required Leveling YES/Construction Standard
Process Control RConstant Speed Constant Flow Constant Pressure DO Signal (4-20mA)

Materials
Casing Steel RAluminum Impeller RAluminum Steel Titanium
Magnet Rare Earth Permanent Magnet Shaft Inconel
Air Filter Pre-filter + HEPA type (2 micron) Enclosure RSteel STS

Note:
1. Motor output power exceeding rated motor output power shall be allowed in the limit of service factor and relevant
conditions
2. Tolerances: +/-4% on the flow, +/- 1% on the power, +/-2db(A) for the noise
3. Flow Modulation : Speed Control by VFD
4. No Condensation
5. Performance shall be derated at ambient temperature higher than 40 deg C
6. Blow-off Valve and Silencer shall be supplied as default loose item
7. VFD Efficiency of 97% is to be assumed for the evaluation of wire input power
8. Noise level is a distance of 3 feet from the blower.