This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 1 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 3 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Revision History
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 4 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
TABLE OF CONTENT
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 5 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Test mode:
Mode 1 Working Record
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 6 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
If the minimum performance level (or the permissible performance loss) is not
specified by the manufacturer, then either of these may be deliver from the product
description and documentation, and by what the user may reasonably expect from
the equipment if used as intended.
1.2.3.Performance criterion C
Loss of function is allowed, provided the function is self-recoverable, or can be
restored by the operation of the controls by the user in accordance with the
manufacture’s instructions.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 7 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
2. GENERAL INFORMATION
2.1.Description of Device (EUT)
EUT : 4Bay-UV Sterilizer
CO-4BAY-100W-UV-10W, CO-4BAY-100W-UV-15W,
CO-4BAY-150W-UV-10W, CO-4BAY-150W-UV-15W,
CO-4BAY-200W-UV-10W, CO-4BAY-200W-UV-15W,
Model Lists :
CO-4BAY-240W-UV-10W, CO-4BAY-240W-UV-15W,
CO-4BAY-UV-50W, CO-4BAY-UV-100W ,
CO-4BAY-UV-150W, CO-4BAY-UV-200W
2.2.Test Facility
EMC Lab. : FCC Registration Number is 254912.
Industry Canada Registration Number is 9642A.
ESMD Registration Number is ARCB0108.
UL Registration Number is 100571-492.
TUV SUD Registration Number is SCN1081.
TUV RH Registration Number is UA 50296516-001.
NVLAP Registration Code is 600167-0.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 8 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
2.4.Measurement Uncertainty
Expanded
Expanded
Test Parameters uncertainty
uncertainty (Ulab)
(Ucispr)
Level accuracy
Conducted 2.63 dB 3.8 dB
(9kHz to 150kHz)
Emission 2.35 dB 3.4 dB
(150kHz to 30MHz)
Level accuracy
Power Disturbance 2.90dB 4.5 dB
(30MHz to 300MHz)
Electromagnetic
Level accuracy
Radiated Emission 3.60 dB 3.3 dB
(9kHz to 30MHz)
(3-loop)
Level accuracy
Radiated Emission 3.68 dB N/A
(9kHz to 30MHz)
Level accuracy
Radiated Emission (30MHz to 3.48 dB 5.3 dB
1000MHz)
Level accuracy
Radiated Emission 3.90 dB 5.2 dB
(above 1000MHz)
Voltage
Fluctuations Voltage 0.510% N/A
& Flicker
(1) Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the apparatus.
(2) The reported expanded uncertainty of measurement is stated as the standard
uncertainty of measurement multiplied by the coverage factor of k=2, which for a
normal distribution corresponds to a coverage probability of approximately 95%.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 9 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 10 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
3.9.Voltage Dips
Item Test Equipment Manufacturer Model No. Serial No. Last Cal.
Voltage dips and up 2019-06-11
1 3CTEST VDG-1105G EC0171014
generator
3.10.Voltage Short Interruptions
Item Test Equipment Manufacturer Model No. Serial No. Last Cal.
Voltage dips and up 2019-06-11
1 3CTEST VDG-1105G EC0171014
generator
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 11 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4. TEST RESULTS
4.1.Power Line Conducted Emission Measurement
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 12 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.1.5.Test Procedure
The EUT is put on the plane 0.8m high above the ground by insulating support and
connected to the AC mains through a Line Impedance Stability Network (L.I.S.N).
This provided a 50ohm coupling impedance for the tested equipments. Both sides
of AC line are investigated to find out the maximum conducted emission according
to the EN 55014-1 regulations during conducted emission measurement.
4.1.6.Test Results
PASS.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 13 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Test Receiver
AC Mains EUT
L.I.S.N
(EUT: 4Bay-UV Sterilizer)
4.2.2.Clicks Measurement Standard and limit
4.2.2.1.Test Standard
EN 55014-1: 2017
4.2.2.2.Test Limit
According to standard EN 55014-1, if click rate (N) less 5/min and the time of this
discontinuous disturbances does not exceed 10ms, then the limit value are
omitted.
4.2.6.Test Results
PASS.
Refer to attached Annex B.2
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 14 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Test Receiver
AC Mains Clamp
EUT
4.3.2.Test Standard
EN 55014-1: 2017
Household and
Tools
similar appliances
1 2 3 4 5 6 7 8 9
Rated motor power
Rated motor power
Frequen above 700 W and Rated motor power
not exceeding 700
cy range not exceeding 1000 above 1000 W
W
W
dB dB dB
dB (pW) dB (pW) dB (pW) dB (pW)
dB (pW) (pW) (pW) (pW)
(MHz) Quasi-pea Quasi-pea Quasi-pea Quasi-pe
Average Averag Averag Averag
k k k ak
e e e
Increasing linearly with the frequency from:
200 to 0 to 10
- 0 to 10 dB - 0 to 10 dB - 0 to 10 dB -
300 dB
NOTE 1 This table only applies if specified in 4.1.2.3.2.
NOTE 2 The measured result at a particular frequency shall be less than the relevant limit minus the
corresponding margin (at that frequency).
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 15 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.3.6.Test Procedure
The EUT is placed on the plane 0.8m high above the ground by insulating support
and away from other metallic surface at least 0.4m. It is connected to the power
mains through an extension cord of 6m min. The absorber clamp clamps the cord
and moves from the far end to the EUT to measure the disturbing energy emitted
from the cord.
4.3.7.Test Results
PASS.
Refer to attached Annex B.3
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 16 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.4.2.Test Standard
EN 61000-3-2: 2014, Class A
4.4.4.Test Results
Pass.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 17 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.5.2.Test Standard
EN 61000-3-3: 2013
4.5.4.Test Results
PASS.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 18 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.6.2.Test Standard
EN 55014-2: 2015(EN 61000-4-2: 2009, Severity Level: 3 / Air Discharge: ±8KV;
Level: 2 / Contact Discharge: ±4KV)
4.6.3.2.Performance criterion: B
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 19 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.6.6.Test Procedure
4.6.6.1.Air Discharge
This test is done on a non-conductive surface. The round discharge tip of the
discharge electrode shall be approached as fast as possible to touch the EUT.
After each discharge, the discharge electrode shall be removed from the EUT. The
generator is then re-triggered for a new single discharge and repeated 10 times for
each pre-selected test point. This procedure shall be repeated until all the air
discharge completed.
4.6.6.2.Contact Discharge
All the procedure shall be same as Section 4.6.6.1. except that the tip of the
discharge electrode shall touch the EUT before the discharge switch is operated.
4.6.6.3.Indirect Discharge For Horizontal Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied at the
front edge of each HCP opposite the center point of each unit (if applicable) of the
EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode
shall be in the plane of the HCP and perpendicular to its front edge during the
discharge.
4.6.6.4.Indirect Discharge For Vertical Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied to the
center of one vertical edge of the coupling plane. The coupling plane, of
dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of
0.1m from the EUT. Discharges shall be applied to the coupling plane, with this
plane in sufficient different positions that the four faces of the EUT are completely
illuminated.
4.6.7.Test Results
PASS.
Refer to attached Annex B.6
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 20 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.7.2.Test Standard
EN 55014-2: 2015 (EN 61000-4-4: 2012, Severity Level: Level 2: 1KV)
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 21 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.7.6.Test Procedure
The EUT is put on the table which is 0.8 meter high above the ground. This
reference ground plane shall project beyond the EUT by at least 0.1m on all sides
and the minimum distance between EUT and all other conductive structure, except
the ground plane beneath the EUT, shall be more than 0.5m.
4.7.6.1.For input and output AC power ports:
The EUT is connected to the power mains by using a coupling device which
couples the EFT interference signal to AC power lines. Both polarities of the test
voltage should be applied during compliance test and the duration of the test is 2
mins.
4.7.6.2.For signal lines and control lines ports:
No I/O ports. It’s unnecessary to test.
4.7.6.3.For DC output line ports:
No DC output ports. It’s unnecessary to test.
4.7.7.Test Results
PASS.
Refer to attached Annex B.7
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 22 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.8.2.Test Standard
EN 55014-2: 2015
(EN 61000-4-5: 2014+A1:2017, Severity Level: Level 2, Line to Line: 1.0KV; Level
3: Line to Ground: 2.0KV)
4.8.3.2.Performance criterion: B
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 23 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.8.6.Test Procedure
4.8.6.1.Set up the EUT and test generator as shown on Section 4.8.1.
4.8.6.2.For line to line coupling mode, provide a 1.0 KV 1.2/50us voltage surge
(at open-circuit condition) and 8/20us current surge to EUT selected points.
4.8.6.3. At least 5 positive and 5 negative (polarity) tests with a maximum 1/min
repetition rate are conducted during test
4.8.6.4.Different phase angles are done individually.
4.8.6.5.Record the EUT operating situation during compliance test and decide the
EUT immunity criterion for above each test.
4.8.7.Test Results
PASS.
Refer to attached Annex B.8
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 24 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.9.2.Test Standard
EN 55014-2: 2015(EN 61000-4-6: 2014, Severity Level: 3V (rms), (0.15MHz ~
230MHz))
4.9.3.2.Performance criterion: A
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 25 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.9.6.Test Procedure
4.9.6.1.Set up the EUT, CDN and test generators as shown on Section 4.9.1.
4.9.6.2.Let the EUT work in test mode and measure it.
4.9.6.3.The EUT are placed on an insulating support 0.1m high above a ground
reference plane. CDN (coupling and decoupling device) is placed on the ground
plane about 0.3m from EUT. Cables between CDN and EUT are as short as
possible, and their height above the ground reference plane shall be between 30
and 50 mm (where possible).
4.9.6.4.The disturbance signal described below is injected to EUT through CDN.
4.9.6.5.The EUT operates within its operational mode(s) under intended climatic
conditions after power on.
4.9.6.6.The frequency range is swept from 150kHz to 230MHz using 3V signal
level, and with the disturbance signal 80% amplitude modulated with a 1kHz sine
wave.
4.9.6.7.The rate of sweep shall not exceed 1.5*10-3 decades/s. Where the
frequency is swept incrementally, the step size shall not exceed 1% of the start
and thereafter 1% of the preceding frequency value.
4.9.6.8.Recording the EUT operating situation during compliance testing and
decide the EUT immunity criterion.
4.9.7.Test Results
PASS.
Refer to attached Annex B.9
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 26 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.10.2.Test Standard
EN 55014-2: 2015 (EN 61000-4-11: 2004+A1:2017)
40 60 10 12
70 30 25 60
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 27 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
4.10.6.Test Procedure
4.10.6.1.Set up the EUT and test generator as shown on Section 4.10.1.
4.10.6.2.The interruptions is introduced at selected phase angles with specified
duration.
4.10.6.3.Record any degradation of performance.
4.10.7.Test Results
PASS.
Refer to attached Annex B.10
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 28 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
ANNEX A
(Test photograph)
A.1.Photo of Power Line Conducted Measurement
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 29 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 30 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
A.5. Photo of Electrical Fast Transient/Burst Test & Surge Immunity Test
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 31 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 32 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
ANNEX B
(Emission and Immunity test results)
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 33 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 34 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
The click rate (N=1/2.1=0.48<5) of the EUT is less than 5/min and the time of this
discontinuous disturbances (△ T=4ms<10ms) does not exceed 10ms.According to
EN 55014-1, the limit values are omitted.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 35 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 36 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Pass.
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 37 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 38 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 39 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 40 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 41 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 42 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
PE
L-PE
N-PE
L-N-PE
Signal Line
I/O Cable
Note:
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 43 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
L-N
L-PE
N-PE
Signal Line
Note
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 44 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 45 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 46 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
ANNEX C
(External and internal photos of the EUT)
Fig. 1
Fig. 2
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 47 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Fig. 3
Fig. 4
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 48 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Fig. 5
Fig. 6
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 49 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Fig. 7
Fig. 8
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 50 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Fig. 9
Fig. 10
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 51 of 52
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS200415090AE
Fig. 11
Fig. 12
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 52 of 52