You are on page 1of 6

H117 Stage

4”x3” Travel (114mm x 75mm), Programmable, The newest version of Prior's H117 stage
Motorized Stepper Stage for Leica, Nikon, Olympus and maximizes access to the nosepiece for
correction collar adjustment. Modified
Zeiss Inverted Microscopes drive boxes occupy a fraction of the space
of previous models providing easy access
to the nosepiece area of the microscope.
Features The entire travel range of the nosepiece is
unobstructed allowing for travel through-
out the focus range with more than ade-
quate clearance from the stage. By mount-
ing all of the drive components below the
Minimum step size (resolution) of the Flat top design facilitates the top plate, the H117 provides easy access
stage is 0.01 microns, depending on use of micromanipulators, for micromanipulators, environmental
the controller configuration environmental chambers and chambers and robotic loaders. The stage
robotic loaders allows for scanning using a very broad
range of sample holders, including
microtitre plates, slide holders, petri dishes,
well plates, flasks, haemocytometers and
metallurgical sample holders. The H117
ProScan™ stage series has a completely
flat top for easy access, and includes the
patented Intelligent Scanning Technology
(IST)®. In conjunction with extensive testing,
Intelligent Scanning Technology
allows each stage to be pre-pro-
grammed with a unique set of operating
characteristics particular to that stage to
ensure optimum performance. IST (also
available on H101A and H107 models)
allows the ProScan™III controller to make
any required adjustments to maintain
superior orthogonally and metric accuracy.
The H117 stage features:
• Flat top design facilitates the use of
micromanipulators, environmental
Stage inserts for slides, petri dishes, chambers and robotic loaders
microtitre plates, well plates, flasks, Travel 114 mm x 75 mm • Travel 114 mm x 75 mm (4" x 3")
metallurgical specimens, slides, and • Optional 50nm linear scales provide
haemocytometers the highest precision available
• Minimum step size (resolution) of the
stage is 0.01 microns, depending on
the controller configuration
• Stage inserts for slides, petri dishes,
microtitre plates, well plates, flasks,
metallurgical specimens, slides, and
haemocytometers
(U.S. Patent 7,330,307)
H117 Stage for Leica DMI Microscopes

General Specifications Ordering Information


Travel Range: 114 mm x 75 mm (4" x 3") Stage:
Repeatability*: +/- 0.75µm with linear scales H117P1D4 Flat top stage for Leica DMI with 1mm
ball screws and 400 step motors
Minimum Step Size (Resolution): 0.01µm H117P2DM Flat top stage for Leica DMI with 2mm
ball screws
Load Capacity: 10 kg
Stepper Motor: 4 phase, 1 amp per phase, Encoded Stages:
micro stepping H117E2DM
Flat top stage for Leica DMI with
0.1µm linear scales
Linear Slides: Precision 3 mm bearings Flat top stage for Leica DMI with
H117EID5 0.05µm linear scales
Drive Screws: Zero backlash, recirculating ball
screws; 2 mm pitch, optional 1mm pitch Options:
Limit Switches: X and Y standard KNOBKIT Add manual override knobs
Weight: 3.5 kg (7.7 lbs)
Standard Sample Holders
Finish: Electrophoretic black plate H223XR Microtitre Plate 128 x 86 mm
*Specifications valid only if used with Prior Controller.
H224XRLP Single Slide Holder - Recessed - 1” x 3”
H237XR Single Slide Holder - Recessed - 2” x 3”
P R I O R S C I E N T I F I C I N C .,
80 R E S E R V O I R P A R K D R I V E , H656 Single 1.25” Diameter - Metallurgical Sample
R O C K L A N D , MA 02370-1062 H657 Single 2.0” Diameter - Metallurgical Sample
T E L E P H O N E 781-878-8442
F A X 781-878-8736 H658 Six 1.25” Diameter - Metallurgical Sample
P RIOR S CIENTIFIC I NSTRUMENTS L TD , PRIOR SCIENTIFIC INSTRUMENTS H659 Single 1.5” Diameter - Metallurgical Sample
GMBH
U NIT 4, W ILBRAHAM R O A D ,
W I L D E N B R U C H S T R . 15 H229XR Petri Dish, Specify Diameter
F ULBOURN , C AMBRIDGE CB1 5ET
D-07745 J E N A
T ELEPH ONE 01223 881711 T E L : +49 (0)3641 675 650 H23x Flask, Specify Size
F AX 01223 881710 F A X : +49 (0)3641 675 651 H2xx Custom Sample
H117 Stage for Nikon MA200 Microscopes
Prior stage inserts for metallurgical Optional 50nm linear scales
samples, glass plate, solid aluminum providing the highest
plate, universal adjustable holder and precision available
custom holders upon request.

Easy access for sample placement


and removal
Fits standard Nikon round
holder insert

Minimum step size (resolution) of the


stage is 0.01 microns, depending on
the controller configuration Travel 114 mm x 76 mm (4" x 3")

General Specifications Ordering Information


Travel Range: 114 mm x 76 mm (4" x 3") Stages:
Repeatability*: +/- 0.75µm with linear scales H117N2MA ProScan stage for Nikon MA200
with 2mm ball screws, 200 step motors
Minimum Step Size (Resolution): 0.01µm
H117N1MA ProScan stage for Nikon MA200
Load Capacity: 10 kg with 1mm ball screws, 400 step motors
Stepper Motor: 4 phase, 1 amp per phase,
Encoded Stages:
micro stepping
H117E2MA ProScan stage for Nikon MA200
Linear Slides: Crossed 3 mm roller bearings with 0.1µm linear scales, 2mm ball
screws and 200 step motor
Drive Screws: Zero backlash, recirculating ball
H117EIMA ProScan stage for Nikon MA200
screws; 2 mm pitch, optional 1mm pitch
with 50 nm linear scales, 1mm ball
Limit Switches: X and Y standard screws and 400 step motor

Weight: 17 lbs. Options:


Finish: Electrophoretic black plate KNOBKIT Add manual override knobs

*Specifications valid only if used with Prior Controller.


Standard Sample Holders
H230 Solid Aluminum Plate
P RIOR S CIENTIFIC I NSTRUMENTS L TD , P R I O R S C I E N T I F I C I N C .,
U NIT 4, W ILBRAHAM R O A D , 80 R E S E R V O I R P A R K D R I V E , H220 Glass Plate
F ULBOURN , C AMBRIDGE CB1 5ET R O C K L A N D , MA 02370-1062
T ELEPHONE 01223 881711 T E L E P H O N E 781-878-8442 H656 Single 1.25” Diameter - Metallurgical Sample
F AX 01223 881710 F A X 781-878-8736
H657 Single 2.0” Diameter - Metallurgical Sample
H658 Six 1.25” Diameter - Metallurgical Sample
P R IOR S CIENTIFIC I NSTRUME N T S
G MB H H659 Single 1.5” Diameter - Metallurgical Sample
W ILDENBRUCHSTR . 15
D-07745 J ENA H473 Universal Adjustable Holder
T EL : +49 (0)3641 675 650
F AX : +49 (0)3641 675 651 H2xx Custom Sample

VISIT PRIOR ON THE WEB AT www.prior.com


Specifications subject to change without notice.
H117 Stage for Nikon Ti Microscopes

General Specifications Ordering Information


Travel Range: 114 mm x 75 mm (4" x 3") Stage:
Repeatability*: +/- 0.75µm with linear scales H117P1N4 Flat top stage for Nikon Ti with 1mm
ball screws and 400 step motors
Minimum Step Size (Resolution): 0.01µm H117P2NN Flat top stage for Nikon Ti with 2mm
ball screws
Load Capacity: 10 kg
Stepper Motor: 4 phase, 1 amp per phase, Encoded Stages:
micro stepping H117E2NN
Flat top stage for Nikon Ti with 0.1µm
linear scales
Linear Slides: Precision 3 mm bearings Flat top stage for Nikon Ti with
H117EIN5 0.05µm linear scales
Drive Screws: Zero backlash, recirculating ball
screws; 2 mm pitch, optional 1mm pitch Options:
Limit Switches: X and Y standard KNOBKIT Add manual override knobs
Weight: 3.5 kg (7.7 lbs)
Standard Sample Holders
Finish: Electrophoretic black plate H223XR Microtitre Plate 128 x 86 mm
*Specifications valid only if used with Prior Controller.
H224XRLP Single Slide Holder - Recessed - 1” x 3”
H237XR Single Slide Holder - Recessed - 2” x 3”
P R I O R S C I E N T I F I C I N C .,
80 R E S E R V O I R P A R K D R I V E , H656 Single 1.25” Diameter - Metallurgical Sample
R O C K L A N D , MA 02370-1062 H657 Single 2.0” Diameter - Metallurgical Sample
T E L E P H O N E 781-878-8442
F A X 781-878-8736 H658 Six 1.25” Diameter - Metallurgical Sample
P RIOR S CIENTIFIC I NSTRUMENTS L TD , PRIOR SCIENTIFIC INSTRUMENTS H659 Single 1.5” Diameter - Metallurgical Sample
GMBH
U NIT 4, W ILBRAHAM R O A D ,
W I L D E N B R U C H S T R . 15 H229XR Petri Dish, Specify Diameter
F ULBOURN , C AMBRIDGE CB1 5ET
D-07745 J E N A
T ELEPH ONE 01223 881711 T E L : +49 (0)3641 675 650 H23x Flask, Specify Size
F AX 01223 881710 F A X : +49 (0)3641 675 651 H2xx Custom Sample
H117 Stage for Olympus IX Microscopes

General Specifications Ordering Information


Travel Range: 114 mm x 75 mm (4" x 3") Stage:
Repeatability*: +/- 0.75µm with linear scales Flat top stage for Olympus IX with
H117P1I4 1mm ball screws and 400 step motors
Minimum Step Size (Resolution): 0.01µm Flat top stage for Olympus IX with
H117P2IX 2mm ball screws
Load Capacity: 10 kg
Stepper Motor: 4 phase, 1 amp per phase, Encoded Stages:
micro stepping H117E2IX
Flat top stage for Olympus IX with
0.1µm linear scales
Linear Slides: Precision 3 mm bearings Flat top stage for Olympus IX with
H117EII5 0.05µm linear scales
Drive Screws: Zero backlash, recirculating ball
screws; 2 mm pitch, optional 1mm pitch Options:
Limit Switches: X and Y standard KNOBKIT Add manual override knobs
Weight: 3.5 kg (7.7 lbs)
Standard Sample Holders
Finish: Electrophoretic black plate H223XR Microtitre Plate 128 x 86 mm
*Specifications valid only if used with Prior Controller.
H224XRLP Single Slide Holder - Recessed - 1” x 3”
H237XR Single Slide Holder - Recessed - 2” x 3”
P R I O R S C I E N T I F I C I N C .,
80 R E S E R V O I R P A R K D R I V E , H656 Single 1.25” Diameter - Metallurgical Sample
R O C K L A N D , MA 02370-1062 H657 Single 2.0” Diameter - Metallurgical Sample
T E L E P H O N E 781-878-8442
F A X 781-878-8736 H658 Six 1.25” Diameter - Metallurgical Sample
P RIOR S CIENTIFIC I NSTRUMENTS L TD , PRIOR SCIENTIFIC INSTRUMENTS H659 Single 1.5” Diameter - Metallurgical Sample
GMBH
U NIT 4, W ILBRAHAM R O A D ,
W I L D E N B R U C H S T R . 15 H229XR Petri Dish, Specify Diameter
F ULBOURN , C AMBRIDGE CB1 5ET
D-07745 J E N A
T ELEPH ONE 01223 881711 T E L : +49 (0)3641 675 650 H23x Flask, Specify Size
F AX 01223 881710 F A X : +49 (0)3641 675 651 H2xx Custom Sample
H117 Stage for Zeiss Axio Observer Microscopes

General Specifications Ordering Information


Travel Range: 114 mm x 75 mm (4" x 3") Stage:
Repeatability*: +/- 0.75µm with linear scales H117P1L4 Flat top stage for Zeiss Axio Observer
with 1mm ball screws & 400 step motors
Minimum Step Size (Resolution): 0.01µm H117P2L2 Flat top stage for Zeiss Axio Observer
with 2mm ball screws
Load Capacity: 10 kg
Stepper Motor: 4 phase, 1 amp per phase, Encoded Stages:
micro stepping H117E2L2
Flat top stage for Zeiss Axio Observer
with 0.1µm linear scales
Linear Slides: Precision 3 mm bearings Flat top stage for Zeiss Axio Observer
H117EIL5 with 0.05µm linear scales
Drive Screws: Zero backlash, recirculating ball
screws; 2 mm pitch, optional 1mm pitch Options:
Limit Switches: X and Y standard KNOBKIT Add manual override knobs
Weight: 3.5 kg (7.7 lbs)
Standard Sample Holders
Finish: Electrophoretic black plate H223XR Microtitre Plate 128 x 86 mm
*Specifications valid only if used with Prior Controller.
H224XRLP Single Slide Holder - Recessed - 1” x 3”
H237XR Single Slide Holder - Recessed - 2” x 3”
P R I O R S C I E N T I F I C I N C .,
80 R E S E R V O I R P A R K D R I V E , H656 Single 1.25” Diameter - Metallurgical Sample
R O C K L A N D , MA 02370-1062 H657 Single 2.0” Diameter - Metallurgical Sample
T E L E P H O N E 781-878-8442
F A X 781-878-8736 H658 Six 1.25” Diameter - Metallurgical Sample
P RIOR S CIENTIFIC I NSTRUMENTS L TD , PRIOR SCIENTIFIC INSTRUMENTS H659 Single 1.5” Diameter - Metallurgical Sample
GMBH
U NIT 4, W ILBRAHAM R OA D ,
W I L D E N B R U C H S T R . 15 H229XR Petri Dish, Specify Diameter
F U LBOURN , C AMBRIDGE CB1 5ET
D-07745 J E N A
T ELEPHONE 01223 881711 T E L : +49 (0)3641 675 650 H23x Flask, Specify Size
F AX 01223 881710 F A X : +49 (0)3641 675 651 H2xx Custom Sample