11-3 Alarm List

Alarm List

Error
Attribute
number Detection details and probable
Error detection function
cause Can be Immediate
Main Sub History
cleared stop *1
Control power supply The DC voltage of the main circuit fell
11 0 undervoltage below the specified value while the   
operation command (RUN) input was ON.
Overvoltage The DC voltage in the main circuit is
12 0   
abnormally high.
Main power supply undervoltage The DC voltage of the main circuit is
0 (Insufficient voltage between P low.   
and N)
13
Main power supply A location was detected where the
1 undervoltage main circuit AC power supply is cut off.   
(AC cut-off detection)
0 Overcurrent Overcurrent flowed to the IGBT.   
14
1 IPM error Motor power line ground fault or short circuit.   
Driver overheat The temperature of the driver radiator
15 0   
exceeded the specified value.
Overload Operation was performed with torque
16 0 significantly exceeding the rating for several   
seconds to several tens of seconds.
Regeneration overload The regenerative energy exceeds the
0 processing capacity of the   
18 Regeneration Resistor.
Regeneration Tr error An error was detected in a driver
1   
regeneration drive Tr.
Encoder communications The encoder wiring is disconnected.
0   
disconnection error
21
1
Encoder communications
error
An encoder communications error
was detected.
   11
Encoder communications Communications cannot be performed
23 0   
data error between the encoder and the driver.
Error and Maintenance
Error counter overflow The error counter accumulated pulse
24 0 exceeds the set value for the Error   
Counter Overflow Level (Pn014).
Excessive hybrid error During full closing control, difference
between position of load from external
25 0 scale and position of motor due to encoder   
was larger than the pulse number set by
Excessive Hybrid Error Setting (Pn332).
Overspeed The motor rotation speed exceeded the set
0   
value of the Overspeed Level set (Pn513).
26
Overspeed 2 The motor rotation speed exceeded the set
1   
value of the Overspeed Level set 2 (Pn615).
Command pulse A command pulse frequency error was
27 0   
detected.
Pulse regeneration error The pulse regeneration output
28 0   
frequency exceeded the limit.

Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL 11-7