Error
Attribute
number Detection details and probable
Error detection function
cause Can be Immediate
Main Sub History
cleared stop *1
Control power supply The DC voltage of the main circuit fell
11 0 undervoltage below the specified value while the
operation command (RUN) input was ON.
Overvoltage The DC voltage in the main circuit is
12 0
abnormally high.
Main power supply undervoltage The DC voltage of the main circuit is
0 (Insufficient voltage between P low.
and N)
13
Main power supply A location was detected where the
1 undervoltage main circuit AC power supply is cut off.
(AC cut-off detection)
0 Overcurrent Overcurrent flowed to the IGBT.
14
1 IPM error Motor power line ground fault or short circuit.
Driver overheat The temperature of the driver radiator
15 0
exceeded the specified value.
Overload Operation was performed with torque
16 0 significantly exceeding the rating for several
seconds to several tens of seconds.
Regeneration overload The regenerative energy exceeds the
0 processing capacity of the
18 Regeneration Resistor.
Regeneration Tr error An error was detected in a driver
1
regeneration drive Tr.
Encoder communications The encoder wiring is disconnected.
0
disconnection error
21
1
Encoder communications
error
An encoder communications error
was detected.
11
Encoder communications Communications cannot be performed
23 0
data error between the encoder and the driver.
Error and Maintenance
Error counter overflow The error counter accumulated pulse
24 0 exceeds the set value for the Error
Counter Overflow Level (Pn014).
Excessive hybrid error During full closing control, difference
between position of load from external
25 0 scale and position of motor due to encoder
was larger than the pulse number set by
Excessive Hybrid Error Setting (Pn332).
Overspeed The motor rotation speed exceeded the set
0
value of the Overspeed Level set (Pn513).
26
Overspeed 2 The motor rotation speed exceeded the set
1
value of the Overspeed Level set 2 (Pn615).
Command pulse A command pulse frequency error was
27 0
detected.
Pulse regeneration error The pulse regeneration output
28 0
frequency exceeded the limit.