Rule VII
street
750mm
Projections beyond the exterior wall shall not exceed beyond a point
one-third the distance from an assumed vertical plane located
where the fire-resistive protection of openings is first required to
the location on property whichever is the least restrictive.
Distance shall be measured at right angles from the property line.
Rule VII - Location on Property
i. Absolutely no abutments are allowed at any property line for any R-1 lot
type/location.
ii. Abutments shall be allowed on only one (1) side for any R-2 lot type/location.
There shall be no firewalls/abutments on the front and rear property lines for
any R-2 lot type/location.
iii. Abutments shall be allowed on two (2) sides only or on one (1) side and the
rear
property line/ boundary for any R-3 lot type/location. There shall be no
abutments on the front property line for any R-3 lot type/location.
Rule VII - BUILDING FOOTPRINT AND FIREWALL
REQUIREMENTS
ABUTMENT
Abutments for Basic Uses/Occupancies forming part of new developments shall
be basically similar to the restrictions prescribed for firewalls under Rule VII, to
wit:
iv. Abutments shall be allowed on two (2) sides only for any R-4 lot
type/location. There shall be no firewalls/abutments on the front and rear
property line for any R-4 lot type/location.
v. Abutments shall be allowed on two (2) sides only or on one (1) side and the
rear
property line/boundary for any R-5 lot type/location. There shall be no
abutments on the front property line for any R-5 lot type/location.
vi. Abutments shall be allowed on two (2) sides only or on one (1) side and the
rear
property line/boundary for any C-3 lot type/location. There shall be no
abutments on the front property line for any C-3 lot type/location.
Rule VII: BUILDING FOOTPRINT AND
FIREWALL REQUIREMENTS
R-1
4mtrs.
high-density
residential (R-3) uses
or occupancies, two
(2) types of firewall
construction may be
permitted (85% total
side, 65% perimeter)
or (90% side/rear,
100% side/rear if
4mtrs. wide provided
85% of total 90% of side and 100% of side
side and 65% rear and rear not to side/rear does not
perimeter exceed 50% of exceed 50%
perimeter
perimeter)
Rule VII - BUILDING FOOTPRINT AND
FIREWALL REQUIREMENTS
R-4
85% of total
side and 50%
perimeter
75% of total
side and 50% 65% of side and
perimeter 50% rear
PD 1096
THE NATIONAL BUILDING CODE