DAIKIN Dynamic Duo-Impeller Magnetic Bearing Chiller


sustainable
performance
technology
legacy

from a
expect

CHILLER?
What do you

about
Reduced Maintenance

Low Investment
performance
sustainable

technology

Environmental
legacy

about
Friendly
Reliability

Low energy consumption Sustainability


performance
sustainable

technology
legacy

about
Magnetic Bearing Chiller
might be the solution
performance
sustainable

technology
legacy

about
A Magnetic Bearing is a bearing that supports a load
using Magnetic Levitation,
which supports moving parts without Physical Contact.

Magnetic Bearing Chiller


might be the solution
MAGNETIC BEARING DETAILS
 No Friction Loss between moving parts
 No Oil system in refrigerant circuit
 With VFD control to adjust capacity on demand
 X-Y-Z axis real time positioning of shaft & bearing
performance
sustainable

technology
legacy
DAIKIN Frictionless Magnetic Compressor
performance
sustainable

technology
legacy
performance
sustainable

technology
legacy

about
MESSAGE FROM
Series
WMT CHILLER, DAIKIN
WMT from Daikin Applied is the chiller that defines a new chiller
generation, it is equipped with the latest technology, runs on the most
environmental refrigerant (R1233zd).

A New Definition of Magnetic Bearing Chiller


ASHRAE STANDARD 34 - 2013

LOW HIGH
TOXICITY TOXICITY
 Toxicity – ASHRAE 34
• A (lower toxicity) or
HIGH A3 B3 • B (higher toxicity)
Increasing Flammability
performance
sustainable

FLAMMABILITY
technology

 Flammability - ASHRAE 34

about
• 1 (no flame propagation)
A2 B2 • 2L (lower flammability)
LOW effect of ignition is not so large
R32
FLAMMABILITY R452B & typically difficult to ignite
HFO1234yf
A2L R454B B2L • 2 (lower flammability)
R447A
HFO1234ze ARM-71a
• 3 (higher flammability)
HFO1233zd R123

NO FLAME A1 B1 R514A
R134a R513A
PROPAGATION R410A R513B
R22 R450A

Increasing Toxicity
2003 2009 2020
1 2 3
performance
sustainable

technology

legacy
Own Leading the

about
Early Adopter
Technology Pack
1st Mag Bearing Perfecting the craft More than 10,000
chiller produced of mag chiller to units of mag chiller
and installed in become the 1st installed worldwide.
China since 2003, chiller manufacturer We now offer next-
still going strong! with own mag gen mag chiller
compressor with HFO
performance
sustainable

technology
legacy
about
We bring a new definition to chiller technology
by
• High efficiency
multi-stage
• Fuji VFD
design
• Air-cooled starter to
• Truly lubrication
have better reliability
free Magnetic
at low lift condition
bearing
• Double • Enhanced Patented
independent IGV Cyclone Economizer
performance
sustainable

technology
• Fewer Ref. charge

legacy
• High separation eff.

about
• Liquid carry over
• PCO5+ preventing
controller
• Advanced
OITS

• Updated liquid
level control • Lower pressure drop design
• More reliable • Patented falling fil evaporator
butterfly valve • New sub cooler for condenser
driven by actuator
All-in-one, only
performance
sustainable

technology
legacy
about
Lubrication
Dynamic Low Drag Robust
Free
Multi-stage Impeller Magnetic Bearing Permanent Magnet Dynamic IGV +
Motor Dynamic Speed Drive
Dynamically Not only oil-free but Eliminates rotor Adaptable to
balanced back-to- truly LUBRICATION- excitation loss to various operating
back impellers FREE, unlike others deliver superior condition that keeps
running on HFO that eliminates the motor efficiency the compressor
refrigerant provides oil but still need under high speed running smoothly to
best efficiency other form of operation optimize the energy
reduces size & noise lubrication used
Duo-Impeller by

Dynamically-
Balance Impellers
Sample 2 back-to-back impellers
performance

working seamlessly
sustainable

technology
together and

legacy
complementing each

about
other like 2 opera singer
in a duo

Sample

TECHNOLOGY.
3D Impeller Design by
With latest CFD analysis, the new 3D impeller is
projected to achieve 2% more efficiency over other
HFO chillers’ peak efficiency
performance
sustainable

technology
legacy
about
Double-IGV by

Individually
1st
Modulated IGV
IGV Each impeller is equipped
performance

with an Inlet Guide Vane


sustainable

technology
(IGV) and optimally

legacy
controlled to give the

about
most accurate cooling
and efficiency

2nd
IGV

TECHNOLOGY.
Dynamic Load Control by
Dynamically
Controlled Loading
Combining proven VFD
Dynamic Speed technology used in Daikin’s Dynamic Refrigerant
Controlled by VSD chillers with Dual-IGV control Controlled by 2 IGV
Controlled RPM and Optimized IGV positions enable part
performance
sustainable

technology
legacy
more than 8% load efficiency* and reduce surging

about
10.0%
Improved - IGV (varying
position) Optimized
8.0%
Performance inprovement form

IGV A° position
6.0%
IGV B° position
4.0%
baseline

IGV C° position
2.0%

0.0% IGV D° position


0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
-2.0% IGV E° position

-4.0%
Baseline - IGV (fixed
position) Non-optimized
-6.0%
% Capacity Loading
*Compare to baseline of fix position IGV
TECHNOLOGY. Optimization of IGV position is obtained
from Daikin’s extensive in-house testing
Superior Evaporator, only
01 02 03
Refrigerant spray
performance
sustainable

technology
legacy
about
Evaporator Liquid Distribution Refrigerant Charge
Great Approach Prevent liquid carry over 30% refrigerant reduction
Approach T can decrease Special designed Multi- For 500RT, evaporator
from 1.3℃ to 0.8℃ by using stage distribution to reduce refrigerant charge decrease
FF, help to get 2% efficiency the highest vapor flow from 483kg to 283kg, save
improvement at full load velocity 42% refrigerant cost.
(500RT WMT) Use mesh filter and 18% cost reduction for
equalization plate to evaporator
prevent liquid carry over
Note: 5 times volute flow
rate than R134a
Horizontal Flash Economizer, only
01 02
CD
TD

CO
FV
performance
sustainable

technology
EV

legacy
With eco. Cooling capacity Power

about
No eco. Cooling capacity Power
10%↑

Increased Reliability and Reduced Cost and Footprint


Efficiency
Better flash gas separation Prevent liquid carry over
Proven patented technology used in Less refrigerant charge compares to
Daikin’s HXEV mag bearing chiller. convectional economizer. Also enables the
Provides better liquid and gas reduction in overall footprint
extraction which enhance reliability
and efficiency
High Quality Components, only

Flow Switch Purge Unit


Thermal type water flow switches are An automatic , highly efficient purge
factory mounted and wired as unit is employed as standard to purge
performance
sustainable

technology
standard. the non-condensable gases.

legacy
about
Refrigerant Flow Control Web Design
Reliable butterfly valve is equipped Here you need to add some brief
as standard that moves by about the service that your company is
continuously monitoring the liquid ref. providing currently
level.

Refrigerant Containment Web Design


Optional factory installed isolation Here you need to add some brief
valves can be supplied to store the about the service that your company is
refrigerant in the condenser if providing currently
necessary.
performance
sustainable

technology
legacy
about
We bring a new definition to chiller plantroom performance
Highest efficiency across the board, only
Superior operating 400RT High lift operating condition
efficiency using: with condenser relief
• Multi-stage Centrifugal
compressor
• Truly Lubrication-Free

performance
sustainable

technology
Magnetic Bearing

legacy
about
Technology
• Dynamic Inlet Guide Vane
(DIGV)
• Dynamic Speed Drive (DSD)
Operating Condition:
• CHW in/out: 5/12Deg C
• CDW in/out: 29.5/35°C

Daikin WMT chiller saves an average 7% efficiency (up to 11%) @ high


lift condition versus competitors’ Multi-stage ceramic bearing centrifugal
chiller with R1233zd refrigerant
Highest efficiency across the board, only
Superior operating 400RT Low lift operating condition at
efficiency using: constant entering condenser water
• Multi-stage Centrifugal condition
compressor
• Truly Lubrication-Free

performance
sustainable

technology
Magnetic Bearing

legacy
about
Technology
• Dynamic Inlet Guide Vane
(DIGV)
• Dynamic Speed Drive (DSD)
Operating Condition:
• CHW in/out: 8/13.5Deg C
• CDW in/out: 29.5/34.6°C

Daikin WMT chiller saves an average 4% efficiency (up to 6%) @ low lift
condition versus competitors’ Single-stage magnetic bearing centrifugal
chiller with R1233zd refrigerant
performance
sustainable

technology
legacy
about
We bring a new definition to sustainability
Truly Lubrication Free Duo-Impeller, only
Not lubrication free!
Truly lubrication free! No
need for lubrication circuit Complex
lubrication
circuit!

performance
sustainable

technology
legacy
about
Not lubrication free!

Complex
lubrication
circuit!
Reduced service maintenance cost, only
All centrifugal chillers
require some amount of
scheduled maintenance
• Cleaning tubes

performance
sustainable

technology
• Checking refrigerant levels

legacy
• The lubrication-free Daikin

about
WMT chiller sets itself apart
with lifetime savings on
driveline maintenance
NO Motor bearing
teardowns
NO Filter changes Sample
NO Lubrication system
maintenance
Compact Footprint, from
Competitor 1

performance
sustainable

technology
legacy
about
Competitor 1
Lowest carbon footprint, only
• Multi stage Mag • Proven Fuji Air-
Bearing with 2 Cooled Dynamic
IGV Speed Drive

• Daikin
Patented

performance
sustainable

technology
Cyclone
Economizer

legacy
about
• Daikin X Carel
PCO5+
Controller

• Daikin • Daikin
Dynamic Patented
Refrigerant
Falling Film
Control
Evaporator
Technical Features-Smart Control Center
User-friendly Operation Easy Troubleshooting BAS

1.Key operating 1.Alarm History 1.Protocols:


parameters on the 2.Monitor operating Lonworks, Modbus
screen conditions or BACnet
2.Change the set 3.Troubleshooting 2.Easy to integrate
points easily and fault analysis into BAS, for data
4.Download the exchange , alarm
chiller operating notification and
Safety manual via USB
Stable equipment monitor.
Efficient
Message from Our WMT :
 Environment friendly HFO R-1233zd Refrigerant, A1 Safety classification (No flame & Low
Toxicity).
 All low pressure refrigerant are inherently high efficiency. low pressure chiller KW/TR is
always lower than medium pressure chiller.
 The best-in -class efficiency of Magnetic centrifugal chiller than conventional centrifugal
VFD Chiller. Better efficiency in full load & part load
 Multi stage compressors is always lower Kw/TR VS single stage
 The standard WMTC includes : VFD driven multi-stage semi-hermetic magnetic bearing
centrifugal compressor, shell and tube hybrid falling film type evaporator, shell and tube
type condenser, flash tank economizer, electronic refrigerant flow control device, purge
device, control system, interconnecting wiring.
DAIKIN 24/7 CUSTOMER CARE SERVICE

Call us at anytime...
….We ensure our
customer comfort and
peace of mind ☺